Home > Toshiba > Communications System > Toshiba Strata Xiie, Strata Xxe Electronic Key Telephone Systems Installation And Maintenance Manual

Toshiba Strata Xiie, Strata Xxe Electronic Key Telephone Systems Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Xiie, Strata Xxe Electronic Key Telephone Systems Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHART NO. 1 
    FAULT CLASSIFICATION 
    From 
    FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    (cont.) 
    t NO 
    MOH. BGM, Page 
    or Relay Servvx 
    t NO  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 2 
    POWER FAULTS 
    here from the NO 4 Go to Page 4 
    to classify 
    fault. 
    YES YES 
    NOTES: 
    1. Check HPSU voltages per Figure 2. 
    2. If HPSlJ voltages are not 
    correct, reset with circuit breakers per 
    Fiaure 2. 
    3. Vkfy that power is present in 
    at least one EKT connected to 
    each HSTlJ. 
    Call the Service 
    > 
    Center for 
    assistance. 
    -6-  
    						
    							CHART NO. 3 
    STATION FAULTS FAULT FINDING 
    SECTION 3QO-020~500 
    DECEMBER 1986 
    / -1 line cord. 
    I 
    NO 
    YES 
    END 
    YES 
    stations cn the 
    To 
    -7-  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 3 
    STATION FAULTS 
    (cont.1 
    Replace the 
    appropriate 
    HSTU. From 
    statIons served 
    NO Replace the 
    appropriate 
    i-----J HCBU. 
    YES 
    YES 
    I 
    I NO 
    Tag the 
    defective unit(s) 
    and return 
    for repalr. 
    L1 END Replace the 
    HCAU 
    (refer to 
    Paragraph 05.01) NOTE: 
    STRATA XX, only. 
    (STRATA XII, uses 
    only one HCBU.) 
    HCBlJ #I supports 
    stations 10~42, 
    HCBU #2 supports 
    stations 43&65. 
    1. Perform the 
    initialization 
    SequenCe before proceeding. 
    2. Reprogram as 
    YES 
    4 
    I 
    NO 
    To 
    NO 
    stat8044 access 
    YES 
    To 
    b 
    co3 
    Page 11  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 4 
    HKSU FAULTS 
    From 
    KSU 
    0 
    Page 4 
    From 
    Kl 
    This 
    Page 
    P  here from the NO 
    5 Go to Page 7 
    to classify 
    fault. 
    From 
    Replace all PCBs 
    in above list with 
    a known good set 
    (refer to 
    Paragraph 05.011. t NOTES: 
    1. Perform the 
    initializa bon 
    1 YES 
    Call the Serwce NO 
    Center for r 
    assistance.  Remove all PC& 
    from the HKSU 
    except: 
    HCAUICAAU 
    HCBU #l 
    HINU 
    HSTU #l 
    l--r---- 
    time. 
    -If trouble occurs, 
    reolace suspected 
    I.22 
    one at a time 
    in the order listed 
    above, until the 
    fault is cleared  1. Perform the 
    initialization 
    - 
    2. Reprogram as 
    l Reinstall all PCBs, 
    YES one at a time. 
    be accessed by 41 
    * If trouble occurs, 
    replace suspected 
    PCB. 
    Tag the 
    defective unit(s) 
    and return 
    for repair. 
    I- 
    ‘& 
    -9-  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    here from the 
    CHART NO. 5 
    CO LINE FAULTS 
    Go to Page 4 
    to classify 
    fault. 
    as required. END 
    t NO 
    t NO t 
    Replace 
    STAU associated 
    with affected 
    / Is  .-- I Tao the I 
    defective unit(s) 
    and return 
    for repatr. Verify continuity 
    of wiring between 
    that HCOU and 
    the connecting 
    -1 o-  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 5 
    CO LINE FAULTS (cont.) 
    Replace the 
    YES 
    Replace the 
    HCAUICAAU 
    (refer to 
    Paragraph 05.01 I.’ 
    NOTES: 
    1. Perform the initialization 
    1 YES sequence before proceeding. 
    2. Reprogram as required. 
    Remove all PCBs 
    from the HKSU 
    except: 
    l HCAU/CAAU l HINU 
    - HCBU #l 
    . HSTU #1 
    l HCOU 
    NO 
    l Reinstall PCBs, 
    one at a time. 
    l If troubles occurs. 
    replace suspected 
    PCB. Tag the 
    defective unit(s) 
    v 
    and return 
    for repair. 
    t 
    EN0 
    -ll-  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 5 
    CO LINE FAULTS (cont.) 
    1 
    Page 11 
    Y 
    Replace all PCBs. 
    one at a time 
    in the order listed 
    above, until the 
    fault is cleared 
    (refer to 
    Paragraph 05.01). 
    1 --- 
    NOTES: 
    1. Perform initialization 
    l Reinstall remaining 
    PCBs, one at a Tag the 
    YES 
    ~ time. defective unit(s) 
    l If trouble occurs. and return 
    replace suspected for repair. 
    PCB. 
    Call the Servlce 
    assistance. 
    -12-  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 6 
    INTERCOM FAULTS 
    From 
    INT 
    Page 5 
    c  ziizicL}-------- 
    NO 
    fransmlss8on 
    HSTU and STAU s. 
    Replace the 
    HINU. 
    Y NO 
    ICl 
    u Page 14 
    t t 
    Tag the 
    defective unit(s) 
    and return 
    for repair. 
    END  
    						
    							FAULT FINDING 
    SECTION 300-020-500 
    DECEMBER 1986 
    CHART NO. 6 
    INTERCOM FAULTS (cont.) 
    Replace the 
    HCAUICAAU 
    (refer to 
    Paragraph 05.01). 
    1. Perform the 
    initialization 
    2. Reprogram 
    YES 
    NO 
    Replace the. 
    HCBU #l. Replace the 
    HCBU #2, if 
    equipped (STRATA 
    xx, only). 
    e3 EN0 
    -14-  
    						
    All Toshiba manuals Comments (0)

    Related Manuals for Toshiba Strata Xiie, Strata Xxe Electronic Key Telephone Systems Installation And Maintenance Manual