    							FAULT FINDING 
    SECTION 100-020-500 
    JANUARY 1984 
    CHART NO. 12 
    OPL FAULTS 
    here from the NO Go to Page 7 
    w 
    to classify 
    fault. 
    OPL function 
    Verify the external 
    equipment and 
    Treat as a CO 
    < the fault line fault. Substitute 
    cleared? MPLU when MCOU 
    is called for. 
    -28-  
    						
    							TB 020-8401 
    April 1, 1984 
    FCC REGISTRATION INFORMATION 
    The STRATA XII & XX systems are FCC registered for connection to the public 
    telephone network and off premise station (OPS) lines. The detailed information is: 
    General 
    . 
    Registration Number 
    BF287N-11115-KF-E 
    Public Telephone Network 
    Ringer Equivalence 
    Connector Type 
    STRATA PCB Type 0.5B 
    RJ 25C 
    MCOU 
    Off Premise Station Line 
    Facility Interface Code 
    Service Code 
    Connector Type 
    STRATA PCB Type OL13C” 
    9.OF 
    RJ 25C 
    MOPU 
    *NOTE: 
    To be compatible with OL 73C, the OPS interface (MOPU PCB) must be equipped 
    with a -48 V power supply. 
    Division of Toshiba America. Inc. 
    2441 Michelle Drive. Turin. C.4 92tiRO I iI4l i.io-5000 
    I I1 Business Park Drive. ,
    monk. N Y. 10504 19141 273- IiS
    						
    							TB-O20-8402 
    April 15, 1984 
    PROPER MSTU/MXPU INSTALLATION REQUIRED 
    In its power-up sequence, the StrataXII&XXsoftware checks to verify that the primary 
    matrix(MXPU) exists for each station interface (MSTU). If an MSTU is present without that matrix, 
    a// 
    stations will be inoperative. To bring the system into operation it is necessary to: 
    l Power down 
    l Remove the excess MSTU or add the missing MXPU 
    l Power up 
    It is possible to add and remove MSTUs and MXPUsfreely while the power is on; however, if the 
    power is switched off and on while a mismatch is present, the system will not function. 
    The expanded matrix (MXPUs 2,4,6 &. 8) in 
    StrataXXis also checked during thee pow_er-up 
    sequence. This expanded matrix is not required for the system to function, but CO lines 13-21 
    and intercoms 5 & 6 will not function unless these PCBs are present during power-up. It is 
    permissible, however, to have some stations with the expanded matrix and others without it. If a 
    new MXPU is added to an existing system, its presence will not be recognized until the power is 
    cycled OFF/ON. 
    Refer to the table below’for the proper MXPU locations. 
    Strata X/I&XX 
    CROSSPOINT MATRIX LOCATIONS 
    Division of Toshiba Amerii‘a. Inc. 
    244 I Xchellc Drive. Turin. CA 92680 t i 141 730-5000 
    1 I1 Business Park Drive. Armonk. N.Y. 10504 1914) 273- 1750  
    						