Have a look at the manual Toshiba Strata S Electronic Key Telephone System Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SYSTEM PROGRAMMI#G SECTION 100-003-390 JULY 1994 e.. . - TABLE 9 PROGRAM 20-TOLL RESTRICTION DISABLE 1. Lock in SET switch. 2. Depress the (SPKRI key on station 17. 3. Dial q q on dial pad. 4. Refer to the System Record Sheet. Using the m keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself-that is, if the CO 1 LED is on, Toll Restriction will not function on CO 1. If CO 1 LED is off, Toll Restriction will function on CO 1 _ etc. 5. Depress the l=I key to place new data in memory. 6A. Go to Step 2 in another program table . . . or. . . 66. Transfer data into working memory per Paragraph 02.06. SET LED on. Station 17 MW/FL LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steadv on. SPKR LED flashes continuously. CO LEDs are on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the associated key will turn it off and vice- versa. LEDs may be turned off and on until the desired pattern is set. : All station 17 LEDs (except MW/FL) go off.. SET LED goes off. Station 17 MW/FL LED goes off. New data is stored. previous data is erased.
SYSTEM PROGRAMMING SECTION 199-993-399 JUCY 1994 TABLE 10 PROGRAM 2X-TOLL RESTRICTION EXCEPTION CODES 1. Lock in SET switch. 2. Depress the /SPKRl key on station 17. 3. Dial q a on the dial pad. X = 1,2,3, ztc.-the system will store a maximum of five ties. Dial 0111 (X = 1) to program first exception code, q @ (X = 2) to program second exception code, etc. 4. Refer to the System Record Sheet. Using :he dial pad, enter the required 4-digit excep- :ion code (four digits must be entered). l ff less than four digits are used, enter q for remaining digits. 1 I I I SET LED on. Station 17 MW/FL LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. AD 2 LED will flash. INT, CO 1,2 & 3 LEDs will light to display data in Binary format. 2nd Digit AD 2. 3 & 4 LEDs will light steadily to indi- cate which digit is being displayed. * I I Steady 3rd Digit Steady Steady 4th Dieii steady Kev/LED Start AD4 L AD3 AD2 Flash 1st Digit steady , co3 Binatv Data Binary Data Binary Data Binary Data I co2 Binary Data Binary Data Binary Data Binary Data . co1 8inary Data Binary Data Binary Data Binary Data INT Binary Data Binary Data Binary Data Binarv Data NOTES: 1. Depressing the q key displays the data wtihout changing it The first q the second q will displa y the first dig&- will display the second dig& etc. data without ente X=LEDon AllLEDsoff=nodata I memorv. Return to Step 2 in order to continue th this program . ..or... Go to Step 2 in another program table . . . or... Tran3er data into working memory per lgraph 02.06. ,. - SET LED goes off. Station 17 MW/FL LED goes off.
SYSTEM PROGfIAMYlNG SECTION lW4G3400 JULY 1984 . - TABLE 11 PROGRAM SXX-STATION CO LINE ACCESS 1. Lock in SET switch. 2. Depress the 1 SPKR [ key on station 17. 3. Dial mm @ on the dial pad. XX = the number of the station(s) to be programmed. l Enter q n if all stations are to be programmed simultaneously. l Enter q m if four lower numbered stations (10 - 13) are to be programmed simultaneously. SET LED on. Station 17 MW/FL LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs will be on according to present data. l Enter j?jj (?l if four higher numbered stations (14 - 17) are to be programmed simultaneously. I 4. Refer to the System Record Sheet. Using the CO keys, turn their associated LEDs on or off, as required. 0 LED on = Access allowed l Each CO key/LED represents itself-that is, if the CO 1 LED is on, then the station being programmed (XX) is allowed access to CO 1, etc. 5. Depress the 1-1 key to place new data in memory. An X on the record sheet means the LED should be on. If the LED is already on, depressing its as- sociated key will turn it off and vice-versa. LEDs may be turned off and on until the desired pattern is set. All station 17 LEDs (except MW/FL) go off. 6A. Return to Step 2 in order to continue with this program 66. Go to Step 2 in’&%& program table . . . 6C. Transfer data intoOCwwking memory per Paragraph 02.06. , . SET LED goes off: Station 17 MW/FL LED goes off. New data is stored, previous data is erased. ,.-- -2o-
SYSTEM PROGRAMMING - SECTION 100-003-300 JULY 1984 TABLE 12 . PROGRAM 4XX-STATION TYPE and FLEXIBLE KEY ASSIGNMENT SET LED on. 1. Lock in SET switch. Station 17 MW/FL LED on. System is in program mode. 2. Depress the 1 SPKR 1 key on station 17. 3. Dial 1’ rrrl Kl on the dial pad. XX = the number of the station(s) to be programmed. l Enter Dm if all stations are to be pro- grammed simultaneously. l Enter q I if four lower numbered sta- tions (10 - 13) are to be programmed simultaneously. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. INT & CO LEDs will be on according to present data. e Enter q q if four higher numbered sta- tions (14 - 17) are to be programmed simultaneously. 4. Refer to the System Record Sheet. Using An X on the record sheet means the LED the INT and CO keys, turn their associated should be on. LEDs on or off, as required. If the LED is already on, depressing its as- The detailed meaning of each key is shown sociated key will turn it off and vice-versa. - below. LEDs may be turned off and on until the desired pattern is set. Key/LED. EKT TYPE” 1 O-key 20-key co2 #2 #3 ,COl - #2 “See Figure 1 INT #1 #l 5. Depress the mj key to place new data All station 17 LEDs (except MW/FL) go off. in memory. 6A. Return to Step 2 in order to continue with this program 6B. Go to Step 2 in.ar%er program table . . . or. . . 6C. Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 MW/FL LED goes off. New data is stored, previous data is erased. ..- -21-
SYSTEM PROGRAMMING ‘.. SECTION 199-093-390 JULY 1994 e.. TABLE 13 PROGRAM SXX-STATION CLASS OF SERVICE 1. Lock in SET switch. all stations are to be pro- if four lower numbered sta- - 13) are to be programmed simultaneously. l Enter q m if four higher numbered sta- tions (14 - 17) are to be programmed and AD keys, turn their asso- ciated LEDs on or off, as required. The detailed meaning of each key is shown below. should be on. If the LED is already on, depressing its as- sociated key will turn it off and vice-versa. LEDs may be turned off and on until the or. . . 6B. Go to Step 2 in’another program table . . . or . . . 6C. Transfer data into working memory per Paragraph 02.06. /FL LED goes off. red, previous data is erased. ,. - -22-
‘. SYSTEM PROGRAMMI#G SECTlON100-003-300 JULY 1994 TABLE 14 PROGRAM GXX-TOLL RESTRICTION CLASSIFICATION 1. Lock in SET switch. W/FL LED on. number of the station(s) to be programmed. l Enter q j?jJ if all stations are to be pro- grammed simultaneously. l Enter a/-i-J if four lower numbered sta- tions (10 - 13) are to be programmed simultaneously. . . l Enter ]a p) if four higher numbered sta- D keys, turn their asso- IS already on, depressing its as- with this program 66. Go to Step 2 in’ar$her program table 6C. Transfer data into working memory per Paragraph 02.06. -23-
SYSTEM PROGRAMMING SECTION 199-993-399 JULY 1994 v.. TABLE 15 PROGRAM 7XX-STATION OUTGOING CALL RESTRICTION SET LED on. 1. Lock in SET switch. 2. Depress the ISPKR] key on station 17. 3. Dial 17 fl Kl on the dial pad. XX = the number of the station(s) to be programmed. l Enter /?jJa if all stations are to be programmed simultaneously. l Enter q j-iJ if four lower numbered stations (10 - 13) are to be programmed simultaneously. Station 17 MW/FL LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs will be on according to present data. l Enter m m if four higher numbered stations (14 - 17) are to be programmed simultaneously. 4. Refer to the System Record Sheet. Using the CO keys, turn their associated LEDs on or off, as required. * LED on = Restricted outgoing calls. l Each CO key/LED represents itself-that is, if the CO 1 LED is on, then the station being programmed (XX) is restricted from outgoing calls on CO 1, etc. ’ . An X on the record sheet means the LED should be on. If the LED is already on, depressing its as- sociated key will turn it off and vice-versa. LEDs may be turned off and on until the desired pattern is set. 5. Depress the [‘I key to place new data in memory. All station 17 LEDs (except MW/FL) go off. 6A. Return to Step 2 in order to continue with this program 68. Go to Step 2 in’igthei program table . . . or. . . 6C. Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 MW/FL LED goes off. New data is stored, previous data is erased. . . - -24-
w.. SYSTEM PROGRAMMING SECTION 100-003-300 JULY 1994 TABLE 16 PROGRAM 8xX-CO RINGING ASSIGNMENTS-DAY SET LED on. 1. Lock in SET switch. Station 17 MW/FL LED on. System is in program mode. 2. Depress the ISPKR 1 key on station 17. 3. Dial mm m on the dial pad.* XX = the number of the station(s) to be programmed. 0 Enter q a if all stations are to be programmed simultaneously. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs will be on according to present data. l Enter q m if four lower numbered stations (10 - 13) are to be programmed simultaneously. l Enter m m if four higher numbered stations (14 - 17) are to be programmed simultaneously. 4. Refer to the System Record Sheet. Using the CO keys, turn their associated LEDs on or off, as required. l LED on = Ring in DAY mode. 0 Each CO key/LED represents itself-that is, if the CO 1 LED is on, then the station being programmed (XX) will ring when a call comes in on CO 1 in DAY mode. 5. Depress the m) key to place new data in memory. An X on the record sheet means the LED should be on. If the LED is already on, depressing its as- sociated key will turn it off and vice-versa. LEDs may be turned off and on until the desired pattern is set. All station 17 LEDs (except MW/FL) go off. 6A. Return to Step 2 in order to continue with this program 6B. Go to Step 2 in.ar%her program table . . . or... 6C. Transfer data into working memory per Paragraph 02.06 SET LED goes off. Station 17 MW/FL LED goes off. New data is stored, previous data is erased. NOTE: Station(s) being designated to ring must be allowed access by Program 3XX. ,.- -25-
SYSTEM PROGRAMMING SECTION 100-003-300 JULY 1994 TABLE 17 PROGRAM 9xX-CO RINGING ASSIGiVMENTS-NITE 1. Lock in SET switch. 2. Depress the m key on station 17. 3. Dial jq rjil rjil on the dial pad.* XX = the number of the station(s) to be programmed. l Enter q m if all stations are to be programmed simultaneously. l Enter q a if four lower numbered stations (10 - 13) are to be programmed simultaneously. SET LED on. Station 17 MW/FL LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs will be on according to present data. l Enter m Tz] if four higher numbered stations (14 - 17) are to be programmed simultaneously. 4. Refer to the System Record Sheet. Using the CO keys, turn their associated LEDs on or off, as required. l LED on = Ring in NITE mode. l Each CO key/LED represents itself-that is, if the CO 1 LED is on, then the station being programmed (XX) will ring when a call comes in on CO 1 in NITE mode. 5. Depress the [mj key to place new data in memory. An X on the record sheet means the LED should be on. If the LED is already on, depressing its as- sociated key will turn it off and vice-versa. LEDs may be turned off and on until the desired pattern is set. All station 17 LEDs (except MW/FL) go off. 6A. Return to Step 2 in order to continue with this program 6B. Go to Step 2 in’ar%er program table . ..or... 6C. Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 MW/FL LED goes off. New data is stored, previous data is erased. NOTE: Station&) being designated to ring must be al/owed access by Program 3XX. -26-
SYSTEM PROGRAMMING JULY 1984 . M.. Strata s” SYSTEM RECORD SHEET PROGRAM 01 -SYSTEM ASSIGNMENTS X = Select (LED on) Initialized Data: AD 4 LED on; all other LEDsoff NOTE: Only one Message Center is permitter2 if both stations 10 and ? 1 are chosen as Message Centers, station 10 will have priority. PROGRAM 05 AUTOMATIC RECALL FROM HOLD TIMING KEY/LED X TIME AD4 ’ 18oseconds AD3 128 Seconds AD2 98 Seconds AD1 84 !%cm& co3 48 Seconds co2 32 !Seconds co i 18 Seconds INT No Recall X = Select (LED on) Initialized Data: 32 Seconds CO LINE OPTIONS PROGRAM 06 PROGRAM 07 AUTOMATIC RELEASE AUTOMATIC RELEASE ON HOLD ENABLE ON HOLD TIMING X = Enable (LED on) initialized Data: All LEDs off X =X6 (LED on) ,.. Initialized Data: All LEDs off -l- SAS-lW-OD3 lOM-l-85