Capacities CTX100 Maximum Capacity Configuration Examples Strata CTX General Description 06/0317 Table 11 CTX100 Base and Expansion Digital Telephones and with T1 and/or PRI lines Ta b l e 1 2CTX100 Base Cabinet Only with Analog Tie, DID and /or Ground Start Lines Table 13 CTX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start Lines 8 Universal Slots 72 Stations (Max.) 64 lines (Max.) 112 Stations + T1 and/or PRI lines combined (Max.) StationsT1 and/or PRI lines1 1. PRI lines are limited to 48B channels. 7240/40 6448/48 5656/48 4864/48 4 Universal Slots 40 Stations (Max.) 16 CO lines (Max.) 40 Stations + Analog Tie, DID, Ground Start Lines combined (Max.) StationsAnalog Tie, DID, and/or Ground Start Lines 404 line (Ground Start only) 328 lines (4 Tie/DID max.). 248 line any type 1612 line any type 016 line any type 8 Universal Slots 72 Stations (Max.) 32 CO lines (Max.) 80 Stations + Analog Tie, DID and/or Ground Start Lines combined (Max.) StationsAnalog Tie, DID, and/or Ground Start Lines 7212 lines (4 Tie/DID max.) 6416 lines (8 Tie/DID max.) 5616 lines (12 Tie/DID max.) 4816 lines any type 4820 lines (16 Tie/DID max.) 3224 lines any type 1628 lines any type
Capacities CTX100 Maximum Capacity Configuration Examples 18Strata CTX General Description 06/03
Strata CTX General Description 06/0319 Universal Slot PCBs4 Universal Printed Circuit Boards (PCBs) installed in the Strata CTX100 or CTX670 cabinets provide interfaces for stations, lines, and peripherals. Each PCB measures 7.5 x 5.5 inches (190 x 140 mm) and mounts in the slot with a 44-pin backplane connector. PCB external connections to station equipment are made to the Main Distribution Frame (MDF) using industry-standard connectors. Station, Line and Option PCBs The PCBs are categorized as station, CO line or option PCBs (see Ta b l e s 1 4~16). Feature subassemblies that plug onto a universal slot PCB, such as the Standard Telephone Interface Subassembly (RSTS), are listed below the associated PCB. For further details, refer to the Strata CTX I&M Manual. Table 14 Station PCBs Digital Telephone Interface Unit (ADKU) (CTX100 only) Provides eight circuits for 3000 and/or 2000-series digital telephones. Interface Options: Provides the same interface options as the BDKU (see below), but does not support BDKS. Compatible only with CTX100. Standard Telephone Interface Unit (ASTU) (CTX100 only) Provides two standard telephone circuits. Maximum number of ringers per circuit is threeInterface Options: Standard telephones (no message waiting) Other single-line devices Alternate BGM source Fax machines Vo ic e ma i l d ev i ce s Digital Telephone Interface Unit (BDKU) Provides eight circuits for 3000 and/or 2000-series digital telephones (BDKU) + eight more with BDKS (optional). Interface Options: Digital telephones (with or without BHEU, BPCI, BVSU, DADMs, or digital cordless telephone). Supports BDKS. Stand-alone digital cordless telephone DDSS console BATI DDCB Supports large LCD (DKT3014) features. Digital Telephone Interface Subassembly (BDKS)Interface Options: Same as BDKU. Not compatible with ADKU or PDKU. Provides eight additional circuits for 3000 and/or 2000- series digital telephones. Attaches to BDKU. One per BDKU. Do not use BDKS for Speaker OCA telephones, except in slot 103 of the CTX100.
Universal Slot PCBs Station, Line and Option PCBs 20Strata CTX General Description 06/03 Digital Telephone Interface Unit (PDKU2) Provides eight digital telephone circuits. (2000-series phones only. Do not use the PDKU for 3000-series digital telephones. With 3000-series DKTs, the LCD display is only 16 characters wide and the button will not work. Interface Options: Digital telephones (with or without BHEU or HHEU, DVSU, DADMs, or digital cordless telephone) Stand-alone digital cordless telephone DDSS console DDCB Does not support DKT3014-SDL features. Internet Protocol Telephone (IPT) Interface Unit (BIPU-M1A, BIPU-M2A) Provides 16 IPT telephone circuits One 100Base-TX RJ45 port Built-in Digital Signal Processor (DSP) (BIPS1A-16) One RS-232 maintenance port Network Address Translation (NAT) compatible for remote IP telephones (BIPU-M2A) Enhanced version of MEGACO+ for Voice over IP MEGACO+ mobility for Mobility Communications System (MCS) Roaming (BIPU-M2A) Interface Options: LAN, Virtual Private Network (VPN) Internet, VPN WAN, Intranet. Digital/Standard Telephone Interface Unit (RDSU) Without RSTS, provides: Two standard telephone/ Four digital telephone circuits (2000-series phones only). With RSTS, provides: Four standard telephone/ Four digital telephone circuits (2000-series phones only). Interface Options: Digital – same as PDKU. Standard – same as RSTU (standard Message Waiting not available) Standard Telephone Interface Unit (RSTU3) Provides eight standard telephone circuits. Stutter dial tone is provided for Message Waiting audible indication.Interface Options: Standard telephones Vo ic e ma i l p or t s Off-premises stations Other similar devices Alternate BGM source Auto Attendant digital announcer Message Waiting lamp Fax machines ACD announcer Standard Telephone Subassembly (RSTS) Attaches to RDSU. Provides two additional standard telephone circuits. One maximum per RDSU. Interface Options: Same as RSTU, except no Message Waiting lamp. -48 Volt Supply Internal Option (R48S) Attaches to RSTU and RDSU 48VDC circuit for up to eight standard telephone circuits. Interface Options: Optionally interfaces to the RSTU and RDSU to extend loop length of standard telephones from 600 ohms to 1200 ohms. Required for OPS operation. Stratagy DK Provides two, four, six, or eight VM ports. All of the above Stratagy DK systems use eight station ports of Strata CTX capacity. Table 14 Station PCBs (continued)
Universal Slot PCBs Station, Line and Option PCBs Strata CTX General Description 06/0321 Table 15 CO Line PCBs Strata Net Over VoIP Interface Unit (BIPU-Q1A) Provides 16 IP QSIG channels One 100Base-TX RJ45 port One RS-232 maintenance port QSIG over IP standard protocol (ECMA-336) Voice coding G.711/G.729A Built-in Digital Signal Processor (DSP) (BIPS1A-16) NAT compatible Interface Options: LAN, Virtual Private Network (VPN) Internet, VPN WAN, Intranet. Internet Protocol (IP) Interface Unit (BVPU) Provides four VoIP Circuits as E&M Tie lines One 10Base-T port One RS-232 maintenance port H.323 standard for Voice over Internet Protocol (VoIP) Interface Options: LAN, Internet, WAN. Caller ID Interface Unit (RCIU2) Provides four Caller ID circuits. With RCIS: eight circuits. Interface Options: Provides Caller ID LCD display for analog loop or ground start lines with Caller ID. Requires: RCOU, RCOS, RGLU2, RGLU3 or PCOU. Not compatible with T1. Caller ID Interface Subassembly (RCIS) Attaches to the RCIU2. Same as RCIU2. Direct Inward Dialing Interface Unit (RDDU) Provides four DID circuits.Interface Options: DID analog lines. Enhanced 911 CAMA Trunk Interface Unit (RMCU/RCMS) E911 CAMA circuits. Provides up to four CAMA trunk circuits. The RMCU/RCMS eliminates the need for connection of adjunct terminal adapter equipment to E911 CAMA trunks. Requires one or two RCMS PCBs for two or four CAMA lines respectively. E911 analog CAMA trunks. CAMA Trunk Subassembly (RCMS) RCMS attaches to RMCU. Provides two E911 CAMA circuits. Up to two RCMSs per RMCU for four CAMA lines max. (One RCMS comes packaged with the RMCU.) Same as RMCU. Ground/Loop Start Interface CO Line Interface Unit (RGLU2, RGLU3) Provides four ground or loop start line circuits. Each can be individually set for ground or loop start operation.Interface Options: Analog loop or ground start analog lines. ISDN S/T-type Basic Rate Interface Unit (RBSU) Two ISDN BRI S/T point circuits (NT or TE). Each circuit is 2B+1D. (Host for the RBSS.)Interface Options: Network and/or station side. Basic Rate Interface Subassembly (RBSS) Attaches to RBSU. One RBSS subassembly per RBSU. Two ISDN BRI, S point circuits (2B+D each). Interface Options: Station side only.
Universal Slot PCBs Station, Line and Option PCBs 22Strata CTX General Description 06/03 ISDN U-type Basic Rate Interface Unit (RBUU) Provides two ISDN BRI, U point circuits (2B+D each). Host for the RBUS.Interface Options: Network and/or station side. Network side requires a dealer-supplied NT1 interface. Basic Rate Interface Subassembly (RBUS) Attaches to RBUU. One RBUS subassembly per RBUU. Two ISDN BRI, U point circuits (2B+D each) subassembly for the RBUU. Interface Options: Network and/or station side. ISDN Primary Rate Interface Unit (RPTU) Provides (1~8B + D), (1~16B + D), or (1~23B + D) channels (lines), depends on system programming. RPTU2 is required for QSIG Networking. Interface Options: ISDN PRI POTS FX Tie (senderized) Tie (cut through) OUTWATS (intra-LATA) OUTWATS (inter-LATA) InWATS QSIG Loop Start CO Line Interface Unit (RCOU) Provides four CO analog loop start line circuits. With RCOS, provides eight CO analog loop start line circuits. Interface Options: CO analog loop start lines Loop Start CO Line Interface Subassembly (RCOS) Provides four additional Loop Start CO lines. One RCOS subassembly per RCOU. Same as RCOU. T1/DS-1 Interface Unit (RDTU) Provides T1 (DS1) Interface: 1~8, 1~16, or 1~24 channels (lines), depends on system programming.Interface Options: T1 Loop start lines Ground start lines Tie lines (wink or immediate) DID/DOD lines (wink or immediate) Remote Expansion Cabinet Unit (RRCU) Supports two CTX670 Remote Cabinets. 62.5 mµ, multi-mode fiber.Remote Cabinet not supported by main system reserve power. Tie Line Unit (REMU2) Provides four analog Tie line circuits.Interface Options: E&M Tie lines Two- or four-wire transmission Type I signaling Type II signaling Immediate start Wink start Table 16 Option PCBs Option Interface Unit (BIOU)Interface Options: Provides Paging output (600 ohm and three-watt amp), four zone paging relays, three MOH interfaces and four control relays (Night Transfer and BGM mute). Table 15 CO Line PCBs (continued)
Universal Slot PCBs Functional Block Diagrams Strata CTX General Description 06/0323 Functional Block Diagrams The Functional Block Diagrams show the PCBs and interface connectors used for connecting the stations and peripherals (see Figures 6~9). Figure 6 CTX100 System Processor and Option Interface PCBs Data and Speech Highway 6752 ACTUProcessor PCB (one or two per system) Relay ContactsVirtual slot 09 ASTU Relay Contact (Programmable) RCA Jack (600 ohm Page Output) MOH/BGM RCA Jacks Battery Charger ABCS12V Battery 12V Battery (2 or 4 Batteries) ABTC - 3m Cable MOH/BGM Jack +Volume Control APSU112Cabinet Power Supply MOH/BGM Volume Controls Up to Four Programmable Serial (RS-232) Port Modular Jacks Available ACD (CSTA)SMDR Call Accounting Remote CTX WinAdmin PC Local CTX WinAdmin Notes 1. Optional. 2. License Control. Music Source 1: Background Music and/or Music-on-hold Music Source 2: Background Music and/or Music-on-hold Music Source 3: Background Music and/or Music-on-hold BSIS 2 (Optional) Conference SW with PAD Interface PCBBIOU1 1 1 AMDS Remote Maintenance Modem 1 1 Ethernet Interface DTMF/ABR Receivers RJ45 Smart Media Maintenance and Customer Database License Internet Music Source: External Zone Page Background Music Door Lock Control Relay External Zone Page Relays (4 Zones) External Page Amplifier (600 ohm Output) Main Distribution Frame (MDF) Night Bell Control Relay Amplified Page Output (3 Watts) BGM Mute Control Relay Night Control Relay 25 Pair Hub or LAN SMDI or Toshiba Proprietary Integration Toshiba Proprietary Soft Key LCD Link Stratagy ES Voice Mail On this page, all equipment, except Stratagy ES, connected to the system processor PCBs and BIOU PCB is customer-supplied. For ASTU port connection, see Figure 9. For iES32/IVP8 VM port connection, see Figure 9.
Universal Slot PCBs Functional Block Diagrams 24Strata CTX General Description 06/03 Figure 7 CTX670 System Processor and Optional Interface PCBs Data and Speech Highway 5413 BECUProcessor PCB BBCUProcessor PCB Interface PCB Relay Contacts, Page Output Music Source: External Zone Page Background Music Door Lock Control Relay External Zone Page Relays (4 Zones) External Page Amplifier (600 ohm Output) Main Distribution Frame (MDF) Night Bell Control RelayBattery Charger12V Battery 12V Battery (2 or 4 Batteries) MOH/BGM Jack +Volume Control BPSU672Cabinet Power Supply MOH/BGM Volume Controls Up to Four Programmable Serial (RS-232) Port Modular Jacks Available ACD (CSTA)SMDR Call Accounting Amplified Page Output (3 Watts) Remote CTX WinAdmin PC Local CTX WinAdmin BGM Mute Control Relay Night Control Relay Notes 1. Not required for one to two cabinets. Required for three or more cabinets. 2. Optional. See description of License Control earlier in this chapter. 3. Optional one or two per system. 25 Pair Music Source 1: Background Music and/or Music-on-hold Music Source 2: Background Music and/or Music-on-hold Music Source 3: Background Music and/or Music-on-hold 2 BEXS1 Expansion Module BBMS1 Expansion Memory Remote Maintenance Modem (Built-In) BSIS(Optional) Conference SW with PAD Ethernet Interface DTMF/ABR Receivers ( Built-In ) DTMF/ABR Receivers( Built-In ) BIOU3 RJ45 Smart Media Maintenance and Customer Database License Internet MOH/BGM RCA Jacks Hub or LAN SMDI and Stratagy ES Integration Toshiba Proprietary Soft Key LCD Link Stratagy ES Voice Mail On this page, all equipment, except Stratagy ES, connected to the system processor PCBs and BIOU PCB is customer-supplied. For iES32/IVP8 VM port connection, see Figure 9. Attendant Console (see Figure 9 for BATI connection)
Universal Slot PCBs Functional Block Diagrams Strata CTX General Description 06/0325 Figure 8 CTX100 and CTX670 CO Line Side Functional Block Diagram RDTU2 or RDTU3 • 2T1 / DS1(24 Channels / Lines) Loop Start, Ground Start, Tie, DID Digital Voice Lines Channel Service Unit (CSU) 25-pair Amphenol TOSHIBA NDTU Cable DB15 PLL Synchronization Circuits 2 RCOU34 Loop Start Co Lines (Analog) RGLU2, RGLU34 Loop or Ground Start CO Lines (Analog) RCOS (Optional PCB on RCOU Only):4 Loop Start CO Lines (Analog) RCIU2 RCIS4 Caller ID Circuits 4 Caller ID Circuits (Two 4-Wire Modular Jacks) MDF(Two 4-Wire Modular Jacks) (Two 4-Wire Modular Jacks)(Two 4-Wire Modular Jacks) (Two 4-Wire Modular Jacks) 1 RDDU4 DID CO Lines (Analog) REMU4 E&M Tie Lines (Analog) (REMU, Four 8-Wire Modular Jacks)(Two 4-Wire Modular Jacks) Secondary Protectors 2 BPTU1 or RPTU1 or 2ISDN PRI (23B+1D channels) Digital Voice/Data Toshiba RPRI-CBL-KIT Channel Service Unit (CSU) 8-wire Modular Jacks2 ISDN BRI (U) 2 Circuits (NT-1 ) Voice/Data (2B+D)RBUU RBUS ISDN BRI (U) 2 Circuits (NT-1) Voice/Data (2B+D) U 3 U38-wire Modular Jacks 8-wire Modular Jacks ISDN BRI (S/T) 2 Circuits (TE) Voice/Data (2B+D)RBSUNT1 per circuit2 U3T38-wire Modular Jacks RMCUTrunk Circuits for E911 RCMS 2 Trunk Circuits RCMS 2 Trunk CircuitsCAMA Line (2-wire Modular Jacks) CAMA Line (2-wire Modular Jacks) Network Demarcation PointRemote Location(s) Remote Location(s)BVPUVoice Over IP Unit (4 Circuits) BDKU/BDKS or PDKU (CTX100 & CTX670) or RRCURemote Cabinet Interface Card Optical Fiber Cable 3 km/(1.86 mi.) 10Base-T pCabinets Digital Telephone MCK EXTenderMCK Gateway IP Network IP Network 6739 4 Central Office Centrex PBX Common Carrier Other Telephone System E911 Public Safety Answer Point (PSAP) Priviate Networking Lines Data and Speech Highway QSIG networks (RPTU2)4 PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol 1. RCIU2/RCIS tip/ring cross connected to RCOU, RCOS, or RGLU tip/ring at MDF. 2. Customer-supplied equipment. 3. U, S, T, R, are ISDN reference model termination points. 4. RPTU2 is required for QSIG Networking. CTX / DK BVPU Remote Node(s)BIPU-Q2A Strata Net QSIG Over IP Unit 100Base-TXCTX BIPU-Q1A (CTX100 only)ADKU Remote Location(s) BIPU-M2A IP Telephone With or without VPN Router or ServerWith or without VPN Router or ServerIP Network IP Network
Universal Slot PCBs Functional Block Diagrams 26Strata CTX General Description 06/03 Figure 9 CTX100 and CTX670 Station Side Functional Block Diagram S3R3 S3 U3 U3 RBSU 2B+1D/Circuit (2-NT Circuits) RBUU2B+1D/Circuit (2-LT Circuits) 1 11 1 1 2 1 1 RDSU4 4 Digital Telephone Circuits 2 Standard Telephone Circuits ADKU8 Digital Telephone Circuits (max). (CTX100 only) BDKU 8 Digital Telephone Circuits and BDKU/BDKS 16 Digital Telephone Circuits RSTS(Option PCB) 2 Standard Telephone CircuitsR48S(Option PCB, RDSU/RSTU3 Only) -48 Volt Loop Supply R48S(Option PCB, RDSU/RSTU3 Only) -48 Volt Loop Supply RBSS2B+1D/Circuit (2-NT Circuits) RBUS2B+1D/Circuit (2-LT Circuits)Digital Telephone (DKT) and Add-on Module Digital Telephone with BPCI-DI 4 DDCB Cordless DKT MDFB Door Phones and Lock Controls TAPI PC Music on-hold source (up to 8) 1 Pair Modular Cord RS-232 Cable PC 1-pair Modular Cords DPFTModemRS-232 Cables Connects audio path to Attd Console Handset 4 Modular Jacks Main Distribution Frame (MDF) Power Failure Transfer UnitPower Failure Standard Telephone (8 max.) Off-premises Station Secondary Protector 1. Customer-supplied equipment. 2. RSTU2 or above is required for standard telephone message waiting lamp. 3. U, S, T, R are ISDN reference model termination points. 4. PDKU and RDSU should only be used for 2000-series digital telephones. They do not support all of the 3000-series digital telephone features, including LCD. The PDKU also does not support BPCI, BATI and the CTX Attendant Console.Fax6743 RSTU3/BSTU 8 Standard Telephone Circuits PC ISDN Telephone (TE-1, S-Type) COM Port ISDN Telephone (TE-1, U-Type)PC with Video Card (TE-1, U-Type)Digital Single Line Telephone (DKT) Standard Telephone Digital Telephone PDKU24 8 Digital Telephone Circuits iES324~32 Voice Mail Circuits (Programmable) IVP82~8 Voice Mail Circuits (Programmable)Data and Speech Highway ASTU (CTX100 only)2 Standard Telephone Circuits TA BATI Transformer Auto Attendant (Dealer supplied) Stratagy ES Voice Mail VM Ports Digital Telephone with DSS Console PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol PageScroll ModeFeature MsgMicRedialSpdialSpkrCnf/TrnHoldVol