Home > Toshiba > Communications System > Toshiba Strata Ctx100, Ctx670 General Description Manual

Toshiba Strata Ctx100, Ctx670 General Description Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Ctx100, Ctx670 General Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Capacities
    CTX100 Maximum Capacity Configuration Examples
    Strata CTX General Description    06/0317
    Table 11 CTX100 Base and Expansion Digital Telephones and with T1 and/or PRI lines
    Ta b l e  1 2CTX100 Base Cabinet Only with Analog Tie, DID and /or Ground Start Lines 
    Table 13 CTX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start Lines
    8 Universal Slots
    72 Stations (Max.)
    64 lines (Max.)
    112 Stations + T1 and/or PRI lines
    combined (Max.)
    StationsT1 and/or PRI lines1 
    1. PRI lines are limited to 48B channels.
    7240/40
    6448/48
    5656/48 
    4864/48
    4 Universal Slots
    40 Stations (Max.)
    16 CO lines (Max.)
    40 Stations + Analog Tie, DID, Ground Start Lines 
    combined (Max.)
    StationsAnalog Tie, DID, and/or Ground Start Lines 
    404 line (Ground Start only)
    328 lines (4 Tie/DID max.).
    248 line any type
    1612 line any type
    016 line any type
    8 Universal Slots
    72 Stations (Max.)
    32 CO lines (Max.)
    80 Stations + Analog Tie, DID and/or Ground Start Lines 
    combined (Max.)
    StationsAnalog Tie, DID, and/or Ground Start Lines
    7212 lines (4 Tie/DID max.)
    6416 lines (8 Tie/DID max.)
    5616 lines (12 Tie/DID max.)
    4816 lines any type
    4820 lines (16 Tie/DID max.)
    3224 lines any type
    1628 lines any type 
    						
    							Capacities
    CTX100 Maximum Capacity Configuration Examples
    18Strata CTX General Description    06/03 
    						
    							Strata CTX General Description    06/0319
    Universal Slot PCBs4
    Universal Printed Circuit Boards (PCBs) installed in the Strata CTX100 or CTX670 cabinets 
    provide interfaces for stations, lines, and peripherals. Each PCB measures 7.5 x 5.5 inches (190 x 
    140 mm) and mounts in the slot with a 44-pin backplane connector. PCB external connections to 
    station equipment are made to the Main Distribution Frame (MDF) using industry-standard 
    connectors.
    Station, Line and Option PCBs
    The PCBs are categorized as station, CO line or option PCBs (see Ta b l e s  1 4~16). Feature 
    subassemblies that plug onto a universal slot PCB, such as the Standard Telephone Interface 
    Subassembly (RSTS), are listed below the associated PCB. For further details, refer to the Strata 
    CTX I&M Manual.
    Table 14 Station PCBs   
    Digital Telephone Interface Unit (ADKU) (CTX100 only)
    Provides eight circuits for 3000 and/or 2000-series 
    digital telephones.
    Interface Options: Provides the same interface options 
    as the BDKU (see below), but does not support BDKS. 
    Compatible only with CTX100.
    Standard Telephone Interface Unit (ASTU) (CTX100 only)
    Provides two standard telephone circuits. Maximum 
    number of ringers per circuit is threeInterface Options: 
    Standard telephones (no message waiting)
    Other single-line devices
    Alternate BGM source
    Fax machines
    Vo ic e ma i l d ev i ce s
    Digital Telephone Interface Unit (BDKU)
    Provides eight circuits for 3000 and/or 2000-series 
    digital telephones (BDKU) + eight more with BDKS 
    (optional).
    Interface Options: Digital telephones (with or without 
    BHEU, BPCI, BVSU, DADMs, or digital cordless 
    telephone). Supports BDKS.
    Stand-alone digital cordless telephone
    DDSS console
    BATI
    DDCB
    Supports large LCD (DKT3014) features.
    Digital Telephone Interface Subassembly (BDKS)Interface Options: Same as BDKU. Not compatible 
    with ADKU or PDKU.
    Provides eight additional circuits for 3000 and/or 2000-
    series digital telephones. Attaches to BDKU. One per 
    BDKU. Do not use BDKS for Speaker OCA 
    telephones, except in slot 103 of the CTX100. 
    						
    							Universal Slot PCBs
    Station, Line and Option PCBs
    20Strata CTX General Description    06/03
    Digital Telephone Interface Unit (PDKU2)
    Provides eight digital telephone circuits. (2000-series 
    phones only. Do not use the PDKU for 3000-series 
    digital telephones. With 3000-series DKTs, the LCD 
    display is only 16 characters wide and the 
     
    button will not work.
    Interface Options: Digital telephones (with or without 
    BHEU or HHEU, DVSU, DADMs, or digital cordless 
    telephone)
    Stand-alone digital cordless telephone
    DDSS console
    DDCB
    Does not support DKT3014-SDL features.
    Internet Protocol Telephone (IPT) Interface Unit (BIPU-M1A, BIPU-M2A)
    Provides 16 IPT telephone circuits
    One 100Base-TX RJ45 port
    Built-in Digital Signal Processor (DSP) (BIPS1A-16)
    One RS-232 maintenance port
    Network Address Translation (NAT) compatible for 
    remote IP telephones (BIPU-M2A)
    Enhanced version of MEGACO+ for Voice over IP
    MEGACO+ mobility for Mobility Communications 
    System (MCS) Roaming (BIPU-M2A)
    Interface Options: LAN, Virtual Private Network (VPN) 
    Internet, VPN WAN, Intranet.
    Digital/Standard Telephone Interface Unit (RDSU)
    Without RSTS, provides:
    Two standard telephone/
    Four digital telephone circuits (2000-series phones 
    only).
    With RSTS, provides:
    Four standard telephone/
    Four digital telephone circuits (2000-series phones 
    only).
    Interface Options: 
    Digital – same as PDKU.
    Standard – same as RSTU (standard Message Waiting 
    not available)
    Standard Telephone Interface Unit (RSTU3)
    Provides eight standard telephone circuits. Stutter dial 
    tone is provided for Message Waiting audible 
    indication.Interface Options: 
    Standard telephones
    Vo ic e ma i l p or t s
    Off-premises stations
    Other similar devices
    Alternate BGM source
    Auto Attendant digital announcer
    Message Waiting lamp
    Fax machines
    ACD announcer
    Standard Telephone Subassembly (RSTS)
    Attaches to RDSU. Provides two additional standard 
    telephone circuits. One maximum per RDSU.
    Interface Options: Same as RSTU, except no Message 
    Waiting lamp.
    -48 Volt Supply Internal Option (R48S) 
    Attaches to RSTU and RDSU
    48VDC circuit for up to eight standard telephone 
    circuits.
    Interface Options: Optionally interfaces to the RSTU 
    and RDSU to extend loop length of standard telephones 
    from 600 ohms to 1200 ohms. Required for OPS 
    operation.
    Stratagy DK
    Provides two, four, six, or eight VM ports.
    All of the above Stratagy DK systems use eight station 
    ports of Strata CTX capacity.
    Table 14 Station PCBs (continued)  
    						
    							Universal Slot PCBs
    Station, Line and Option PCBs
    Strata CTX General Description    06/0321
     
    Table 15 CO Line PCBs   
    Strata Net Over VoIP Interface Unit (BIPU-Q1A)
    Provides 16 IP QSIG channels
    One 100Base-TX RJ45 port
    One RS-232 maintenance port
    QSIG over IP standard protocol (ECMA-336)
    Voice coding G.711/G.729A
    Built-in Digital Signal Processor (DSP) (BIPS1A-16)
    NAT compatible
    Interface Options: LAN, Virtual Private Network (VPN) 
    Internet, VPN WAN, Intranet.
    Internet Protocol (IP) Interface Unit (BVPU)
    Provides four VoIP Circuits as E&M Tie lines
    One 10Base-T port
    One RS-232 maintenance port
    H.323 standard for Voice over Internet Protocol (VoIP)
    Interface Options: LAN, Internet, WAN.
    Caller ID Interface Unit (RCIU2)
    Provides four Caller ID circuits.
    With RCIS: eight circuits.
    Interface Options: 
    Provides Caller ID LCD display for analog loop or ground 
    start lines with Caller ID. Requires: RCOU, RCOS, 
    RGLU2, RGLU3 or PCOU. Not compatible with T1.
    Caller ID Interface Subassembly (RCIS)
    Attaches to the RCIU2.
    Same as RCIU2.
    Direct Inward Dialing Interface Unit (RDDU)
    Provides four DID circuits.Interface Options: 
    DID analog lines.
    Enhanced 911 CAMA Trunk Interface Unit (RMCU/RCMS)
    E911 CAMA circuits. Provides up to four CAMA trunk 
    circuits. The RMCU/RCMS eliminates the need for 
    connection of adjunct terminal adapter equipment to 
    E911 CAMA trunks. 
    Requires one or two RCMS PCBs for two or four 
    CAMA lines respectively.
    E911 analog CAMA trunks.
    CAMA Trunk Subassembly (RCMS) 
    RCMS attaches to RMCU. Provides two E911 CAMA 
    circuits.
    Up to two RCMSs per RMCU for four CAMA lines max. 
    (One RCMS comes packaged with the RMCU.)
    Same as RMCU.
    Ground/Loop Start Interface CO Line Interface Unit (RGLU2, RGLU3)
    Provides four ground or loop start line circuits. Each 
    can be individually set for ground or loop start 
    operation.Interface Options: 
    Analog loop or ground start analog lines.
    ISDN S/T-type Basic Rate Interface Unit (RBSU)
    Two ISDN BRI S/T point circuits (NT or TE). Each 
    circuit is 2B+1D. (Host for the RBSS.)Interface Options: Network and/or station side.
    Basic Rate Interface Subassembly (RBSS) 
    Attaches to RBSU. One RBSS subassembly per 
    RBSU.
    Two ISDN BRI, S point circuits (2B+D each).
    Interface Options: Station side only. 
    						
    							Universal Slot PCBs
    Station, Line and Option PCBs
    22Strata CTX General Description    06/03
    ISDN U-type Basic Rate Interface Unit (RBUU)
    Provides two ISDN BRI, U point circuits (2B+D each). 
    Host for the RBUS.Interface Options: Network and/or station side. Network 
    side requires a dealer-supplied NT1 interface.
    Basic Rate Interface Subassembly (RBUS)
    Attaches to RBUU. One RBUS subassembly per 
    RBUU.
    Two ISDN BRI, U point circuits (2B+D each) 
    subassembly for the RBUU.
    Interface Options: Network and/or station side.
    ISDN Primary Rate Interface Unit (RPTU)
    Provides (1~8B + D), (1~16B + D), or (1~23B + D) 
    channels (lines), depends on system programming. 
    RPTU2 is required for QSIG Networking.
    Interface Options: 
    ISDN PRI
    POTS
    FX
    Tie (senderized)
    Tie (cut through)
    OUTWATS (intra-LATA)
    OUTWATS (inter-LATA)
    InWATS
    QSIG
    Loop Start CO Line Interface Unit (RCOU)
    Provides four CO analog loop start line circuits.
    With RCOS, provides eight CO analog loop start line 
    circuits.
    Interface Options: 
    CO analog loop start lines
    Loop Start CO Line Interface Subassembly (RCOS)
    Provides four additional Loop Start CO lines. One 
    RCOS subassembly per RCOU.
    Same as RCOU.
    T1/DS-1 Interface Unit (RDTU)
    Provides T1 (DS1) Interface: 1~8, 1~16, or 1~24 
    channels (lines), depends on system programming.Interface Options: 
    T1
    Loop start lines
    Ground start lines
    Tie lines (wink or immediate)
    DID/DOD lines (wink or immediate)
    Remote Expansion Cabinet Unit (RRCU)
    Supports two CTX670 Remote Cabinets. 62.5 mµ, 
    multi-mode fiber.Remote Cabinet not supported by main system reserve 
    power.
    Tie Line Unit (REMU2)
    Provides four analog Tie line circuits.Interface Options: 
    E&M Tie lines
    Two- or four-wire transmission
    Type I signaling
    Type II signaling
    Immediate start
    Wink start 
    Table 16 Option PCBs   
    Option Interface Unit (BIOU)Interface Options: Provides Paging output (600 ohm 
    and three-watt amp), four zone paging relays, three 
    MOH interfaces and four control relays (Night Transfer 
    and BGM mute).
    Table 15 CO Line PCBs (continued)  
    						
    							Universal Slot PCBs
    Functional Block Diagrams
    Strata CTX General Description    06/0323
    Functional Block Diagrams
    The Functional Block Diagrams show the PCBs and interface connectors used for connecting the 
    stations and peripherals (see Figures 6~9).
    Figure 6 CTX100 System Processor and Option Interface PCBs
    Data and Speech Highway
    6752
    ACTUProcessor PCB
    (one or two per system)
    Relay ContactsVirtual slot 09
    ASTU
    Relay Contact (Programmable)
    RCA Jack (600 ohm Page Output)
    MOH/BGM
    RCA Jacks
    Battery Charger ABCS12V
    Battery
    12V
    Battery
    (2 or 4 Batteries)
    ABTC - 3m Cable
    MOH/BGM Jack 
    +Volume Control
    APSU112Cabinet 
    Power Supply MOH/BGM
    Volume Controls Up to Four Programmable Serial (RS-232) 
    Port Modular Jacks Available 
    ACD 
    (CSTA)SMDR
    Call Accounting 
    Remote CTX 
    WinAdmin PC
    Local CTX 
    WinAdmin
    Notes 
    1.  Optional.
    2.  License Control.
    Music Source 1: Background Music 
    and/or Music-on-hold
    Music Source 2: Background Music 
    and/or Music-on-hold
    Music Source 3: Background Music 
    and/or Music-on-hold
    BSIS
    2
    (Optional)
      Conference
    SW with PAD
    Interface PCBBIOU1
    1
    1
    AMDS
    Remote Maintenance
    Modem
    1 1
    Ethernet 
    Interface
    DTMF/ABR
    Receivers RJ45
    Smart Media
    Maintenance
           and 
      Customer
      Database
    License
    Internet
    Music Source: External Zone Page
    Background Music
    Door Lock Control Relay
    External Zone Page Relays (4 Zones)
    External Page Amplifier (600 ohm Output)
    Main Distribution
    Frame (MDF) Night Bell Control Relay Amplified Page Output (3 Watts)
    BGM Mute Control Relay
    Night Control Relay
    25 Pair
    Hub
    or
    LAN
    SMDI or Toshiba Proprietary 
    Integration  
    Toshiba Proprietary Soft Key LCD Link   Stratagy ES
    Voice Mail
    On this page, all equipment, except Stratagy ES, 
    connected to the system processor PCBs and 
    BIOU PCB is customer-supplied.
    For ASTU port 
    connection, 
    see Figure 9. For iES32/IVP8 VM port 
    connection, see Figure 9. 
    						
    							Universal Slot PCBs
    Functional Block Diagrams
    24Strata CTX General Description    06/03
    Figure 7 CTX670 System Processor and Optional Interface PCBs
    Data and Speech Highway
    5413
    BECUProcessor PCB
    BBCUProcessor PCB
    Interface PCB
    Relay Contacts, Page Output
    Music Source: External Zone Page
    Background Music
    Door Lock Control Relay
    External Zone Page Relays (4 Zones)
    External Page Amplifier (600 ohm Output)
    Main Distribution
    Frame (MDF) Night Bell Control RelayBattery Charger12V
    Battery
    12V
    Battery
    (2 or 4 Batteries)
    MOH/BGM Jack 
    +Volume Control
    BPSU672Cabinet 
    Power Supply MOH/BGM
    Volume Controls Up to Four Programmable Serial (RS-232) 
    Port Modular Jacks Available 
    ACD 
    (CSTA)SMDR
    Call Accounting 
    Amplified Page Output (3 Watts) Remote CTX 
    WinAdmin PC
    Local CTX 
    WinAdmin
    BGM Mute Control Relay
    Night Control Relay
    Notes 
    1.  Not required for one to two cabinets. 
         Required for three or more cabinets.
    2.  Optional. See description of License Control
         earlier in this chapter.
    3.  Optional one or two per system.
    25 Pair
    Music Source 1: Background Music 
    and/or Music-on-hold
    Music Source 2: Background Music 
    and/or Music-on-hold
    Music Source 3: Background Music 
    and/or Music-on-hold
    2
    BEXS1
    Expansion
    Module
    BBMS1
    Expansion
    Memory
    Remote Maintenance
    Modem (Built-In)
    BSIS(Optional)  Conference
    SW with PAD
    Ethernet 
    Interface
    DTMF/ABR
    Receivers
    ( Built-In )
    DTMF/ABR
    Receivers( Built-In )
    BIOU3
    RJ45
    Smart Media
    Maintenance
           and 
      Customer
      Database
    License
    Internet
    MOH/BGM
    RCA Jacks
    Hub
    or
    LAN
    SMDI and Stratagy ES Integration  
    Toshiba Proprietary Soft Key LCD Link   Stratagy ES
    Voice Mail
    On this page, all equipment, except Stratagy ES, 
    connected to the system processor PCBs and 
    BIOU PCB is customer-supplied.
    For iES32/IVP8 VM port 
    connection, see Figure 9.
    Attendant
    Console (see
    Figure 9 for 
    BATI connection) 
    						
    							Universal Slot PCBs
    Functional Block Diagrams
    Strata CTX General Description    06/0325
    Figure 8 CTX100 and CTX670 CO Line Side Functional Block Diagram
    RDTU2 or RDTU3 •  2T1 / DS1(24 Channels / Lines)
      Loop Start, Ground Start, Tie, DID
     Digital Voice Lines Channel
    Service
    Unit (CSU) 25-pair Amphenol
    TOSHIBA NDTU Cable
    DB15
    PLL Synchronization Circuits
    2
    RCOU34 Loop Start Co Lines (Analog)
    RGLU2, RGLU34 Loop or Ground Start CO Lines (Analog)
    RCOS (Optional PCB on RCOU Only):4 Loop Start CO Lines (Analog)
    RCIU2
    RCIS4 Caller ID Circuits
    4 Caller ID Circuits
    (Two 4-Wire Modular Jacks)
    MDF(Two 4-Wire Modular Jacks)
    (Two 4-Wire Modular Jacks)(Two 4-Wire Modular Jacks)
    (Two 4-Wire Modular Jacks)
    1
    RDDU4 DID CO Lines (Analog)
    REMU4 E&M Tie Lines (Analog)  (REMU, Four 8-Wire Modular Jacks)(Two 4-Wire Modular Jacks)
    Secondary Protectors
    2
    BPTU1 or RPTU1 or 2ISDN PRI (23B+1D channels)
    Digital Voice/Data Toshiba RPRI-CBL-KIT
    Channel
    Service
    Unit (CSU)
    8-wire Modular Jacks2
    ISDN BRI (U)
    2 Circuits (NT-1  )
    Voice/Data  (2B+D)RBUU
    RBUS ISDN BRI (U)
     2 Circuits (NT-1)
     Voice/Data  (2B+D) U
    3
    U38-wire Modular Jacks
    8-wire Modular Jacks
    ISDN BRI (S/T)
    2 Circuits (TE)
    Voice/Data  (2B+D)RBSUNT1 per circuit2
    U3T38-wire Modular Jacks
    RMCUTrunk Circuits for E911
    RCMS    2 Trunk Circuits
    RCMS    2 Trunk CircuitsCAMA Line (2-wire Modular Jacks)
    CAMA Line (2-wire Modular Jacks) Network 
    Demarcation 
    PointRemote Location(s)
    Remote  
    Location(s)BVPUVoice Over IP Unit (4 Circuits)
    BDKU/BDKS or PDKU   (CTX100 & CTX670) or
    RRCURemote Cabinet Interface Card
    Optical Fiber Cable  
    3 km/(1.86 mi.)
    10Base-T
    pCabinets
    Digital 
    Telephone
    MCK 
    EXTenderMCK 
    Gateway
    IP Network
    IP Network
    6739
    4
    Central Office 
    Centrex
    PBX
    Common Carrier
    Other Telephone System
    E911 Public Safety Answer
    Point (PSAP)
    Priviate Networking Lines 
    
    
    
    
     
    
    
    
    
    
    Data and Speech Highway
    QSIG networks (RPTU2)4
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol
    1. RCIU2/RCIS tip/ring cross
        connected to RCOU, RCOS, or
        RGLU tip/ring at MDF.
    2. Customer-supplied equipment.
    3. U, S, T, R, are ISDN reference
        model termination points.
    4. RPTU2 is required for QSIG
        Networking.
    CTX / DK
    BVPU
    Remote  
    Node(s)BIPU-Q2A Strata Net QSIG Over IP Unit 100Base-TXCTX
    BIPU-Q1A
    (CTX100 only)ADKU
    Remote Location(s)
    BIPU-M2A
    IP Telephone
    With or without  
    VPN Router
    or ServerWith or without  
    VPN Router
    or ServerIP Network
    IP Network 
    						
    							Universal Slot PCBs
    Functional Block Diagrams
    26Strata CTX General Description    06/03
    Figure 9 CTX100 and CTX670 Station Side Functional Block Diagram
    S3R3
    S3
    U3
    U3
    RBSU 
    2B+1D/Circuit
    (2-NT Circuits)
    RBUU2B+1D/Circuit
    (2-LT Circuits)
    1 11 1
    1
    2
    1
    1
    RDSU4
    4 Digital Telephone Circuits
    2 Standard Telephone Circuits
    ADKU8 Digital Telephone Circuits (max).
    (CTX100 only)
    BDKU 8 Digital Telephone Circuits and
    BDKU/BDKS 16 Digital Telephone Circuits
    RSTS(Option PCB)
    2 Standard 
    Telephone 
    CircuitsR48S(Option PCB,
    RDSU/RSTU3
    Only) -48 Volt
    Loop Supply
    R48S(Option PCB,
    RDSU/RSTU3
    Only) -48 Volt
    Loop Supply
    RBSS2B+1D/Circuit
    (2-NT Circuits)
    RBUS2B+1D/Circuit
    (2-LT Circuits)Digital Telephone (DKT)
    and Add-on Module
    Digital Telephone
    with BPCI-DI 
    4
    DDCB Cordless DKT
    MDFB
    Door Phones and
    Lock Controls TAPI PC
    Music 
    on-hold
    source
    (up to 8) 1 Pair Modular Cord
    RS-232 Cable
    PC
    1-pair Modular Cords
    DPFTModemRS-232 Cables Connects audio path to Attd Console 
    Handset 
    4 
    Modular Jacks
    Main Distribution Frame (MDF) Power Failure
    Transfer UnitPower Failure
    Standard Telephone (8 max.)
    Off-premises Station Secondary
    Protector
    1. Customer-supplied equipment.
    2.  RSTU2 or above is required for standard telephone message 
    waiting lamp.
    3.  U, S, T, R are ISDN reference model termination points.
    4.   PDKU and RDSU should only be used for 2000-series digital 
    telephones. They do not support all of the 3000-series digital telephone 
    features, including LCD. The PDKU also does not support BPCI, BATI 
    and the CTX Attendant Console.Fax6743
    RSTU3/BSTU 8 Standard
    Telephone Circuits
    PC
    ISDN
    Telephone
    (TE-1, S-Type) COM Port 
    ISDN
    Telephone
    (TE-1, U-Type)PC with
    Video Card
    (TE-1, U-Type)Digital Single Line
    Telephone (DKT)
    Standard
    Telephone Digital
    Telephone
    PDKU24
    8 Digital Telephone Circuits
    iES324~32 Voice Mail Circuits (Programmable)
    IVP82~8 Voice Mail Circuits (Programmable)Data and Speech Highway
    ASTU (CTX100 only)2 Standard Telephone Circuits
    TA
    BATI
    Transformer
    Auto Attendant  
    (Dealer supplied) 
    Stratagy ES
    Voice Mail
    VM Ports
    Digital Telephone
    with DSS Console
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol
    PageScroll ModeFeature
    MsgMicRedialSpdialSpkrCnf/TrnHoldVol 
    						
    All Toshiba manuals Comments (0)

    Related Manuals for Toshiba Strata Ctx100, Ctx670 General Description Manual