Home > Tone Commander > Telephone > Tone Commander 40d120 Installation Instructions

Tone Commander 40d120 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Tone Commander 40d120 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 24 Tone Commander manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Console Assembly
    40d
    120d
    13-102633 Rev. HPage 31
    Tone Commander 40d120 Installation Instructions
    Figure 1
    1. Install the handset cradle on the 40d console
    using the screws provided. The cradle is
    usually installed on the left side, near the
    handset jack, but may be installed on either
    side of the console.
    2. Plug the handset’s cord into the jack beneath
    the front left edge of the console.
    3. Use the supplied printed keycap labels or type
    feature names on blank labels. Place the labels
    beneath the clear plastic keycaps, then snap
    the keycaps onto the keys.
    (bottom view)
    handset
    jack
    Figure 2
    1. Fasten the console tie bracket beneath the left
    edge of the 120d console using the supplied
    mounting screws.
    2. Fasten the other end of the tie bracket beneath
    the right edge of the 40d console using the
    supplied mounting screws.
    3. If the attendant position has two 120d
    consoles, attach the second 120d console to
    the first in the same manner.
    4. Fill out the keycap labels with station names or
    numbers (refer to the configuration sheets).
    Place the labels beneath the clear plastic key
    caps, then snap the keycaps onto the DSS
    keys.(bottom view)
    120d
    40d 
    						
    							Console Connections
    120d Data Connection
    In addition to the power and telco connection explained below, each 120d console requires one data
    connection to the 40d or adjacent 120d console.
    Refer to Figure on page 34.
    1. 120d #1
    – plug the supplied 4 conductor modular cord into the nearest “DSS” jack on the 40d
    console.
    If installing a second, third, or fourth 120d console, plug the supplied modular cord into the unused
    “DSS” jack on the preceding 120d.
    2. Plug the other end into either “DSS” jack on the 120d console (second 120d if applicable).
    Page 3213-102633 Rev. H
    Tone Commander 40d120 Installation Instructions
    MONRUN
    DSS
    Line/Power
    (U)RS-232
    Serial
    PortProgramming
    SwitchOption
    Switches for
    testing
    onlyDSS
    1
    (DH )2
    (DL)3
    (DL)4
    (DH)
    DSS
    1
    (PS+)2
    (PS-)3
    (N/C)4
    (TIP)5
    (RING)6
    (N/C)7
    (PS-)8
    (PS+)
    Line/Power
    (U)
    Figure 3– 40d and 120d Console Rear Panel 
    						
    							Power and Telco Connection (one per 40d or 120d console)
    Each power supply can power three 40d and/or 120d consoles. Use an additional power supply if the
    attendant position has three or four 120d DSS consoles.
    Power supplies may be installed at the console location or in a remote equipment room.
    Refer to Figure on page 34.
    1. Plug a supplied 8 conductor modular cord into the telco ISDN U-interface jack.
    2. Plug the other end into a “LINE” jack on the power supply.
    3. Plug the second supplied 8 conductor modular cord into the matching “CONSOLE” jack on the
    power supply.
    4. Plug the other end into the “LINE/POWER” jack on the console rear panel.
    5. When ready to test the system, plug the power supply into a standard 120 VAC, 60 Hz outlet.
    13-102633 Rev. HPage 33
    Tone Commander 40d120 Installation Instructions
    Use only the Tone Commander 40d120 Power Supply (model #102612)
    with the following ratings:
    120 VAC @60 Hz
    POWER 
    						
    							Page 3413-102633 Rev. H
    Tone Commander 40d120 Installation Instructions
    Figure 4–Typical Installation 
    						
    							System Programming
    Several network interface and operation parameters are programmable by the installer, allowing
    compatibility with a wide variety of central office features. The system is pre-programmed at the factory;
    many installations will require few changes to these values. Programming is retained in the 40d’s memory
    when power is disconnected. A parameter or feature may be altered at any time without reprogramming the
    entire system.
    The PC-based Setup Utility provided with the 40d120 offers a user interface that simplifies setup and
    name/number entry. Please refer to the 40d120 Setup Utility User’s Guide
    , doc. #14-280177, that
    accompanies the utility diskette.
    All setup information may also be entered using only the console keys, by placing the console in
    Maintenance Mode as explained in this section. The following features may be accessed from Maintenance
    Mode:
    1.System Setup Parameters: SPID numbers, Key assignments, Call queues, Recall timers, Call
    processing loop modes
    2.Name/Autodial Database
    3.Time of Day Clock Setting
    4.System Usage Statistics
    5.System Diagnostics
    Using Maintenance Mode
    The Maintenance Mode must be entered prior to attempting any of the following programming procedures.
    Enter this mode only when the console is idle, i.e., no calls are in progress or on hold.
    ToenterMaintenance Mode:
    Press the MAINT key.
    The display will indicate that Maintenance Mode has been entered. Name programming, time
    setting, system statistics, system setup, or Maintenance Mode exit may be selected with the Hold
    Loop keys.
    Normal key and display operations are suspended. The console will continue to ring and place
    incoming calls in queue.
    In maintenance mode, the six hold loop keys directly below the display act as “soft” function keys.
    Key functions are identified in the bottom line of the display.
    ToexitMaintenance Mode and store all programming:
    
    Press the Hold Loop key associated with EXIT or DONE from any programming screen until the main
    menu is displayed, then select EXIT from the main menu.
    Normal key and display operations will resume. The main menu will be displayed the next time
    the MAINT key is pressed.
    or
    
    Press the MAINT key.
    Normal key and display operations will resume. The last-used menu will be displayed the next
    time the MAINT key is pressed. This allows you to answer a call, then resume programming
    where you left off.
    13-102633 Rev. HPage 35
    Tone Commander 40d120 Installation Instructions
    MAINTENANCE MAIN MENU
    NAMES TIME STATS SETUP DIAG EXIT 
    						
    							Password Protection
    To prevent inadvertent or unauthorized changes to console programming, you can enable password
    protection. Passwords consist of four digits entered with the dial pad or the Setup Utility. Three separate
    passwords are provided:
    Mode Default Password
    Console Setup 7743 (SPID)
    Name/Autodial 6263 (NAME)
    Statistics Reset 7828 (STAT)
    When passwords are enabled, the console will prompt for a password whenever a user attempts to access
    one of the above programming modes.
    Enter the password digits with the dial pad when the Enter Password prompt appears.
    Asterisks are displayed to hide the entered password.
    Select DONE.
    Enabling/Disabling Passwords
    To enable passwords, set option switch 2 ON, then power up the console. If the console is already powered
    up, disconnect power for a few seconds.
    Setting option switch 2 OFF, then cycling console power, disables passwords.
    Changing Passwords
    You can change any of the passwords. All passwords must consist of four digits.
    
    Passwords must be enabled.
    
    Enter Console Setup (page 43), Name/Autodial Programming (page 62), or Statistics Reset (page 67)
    mode.
    The Enter Password prompt for the selected mode is displayed.
    
    At the Enter Password prompt, enter the current password with the dial pad.
    If you don’t know the password, restore the defaults - see Default Passwords below.
    
    Select CHANGE to change the password for the mode shown in the upper right of the display.
    Page 3613-102633 Rev. H
    Tone Commander 40d120 Installation Instructions
    [SETUP]
    Enter Password: ****
    CHANGEABORT DONE
    [SETUP]
    Enter Password: ****
    CHANGE ABORTDONE 
    						
    							Enter the new password with the dial pad.
    Select NEXT, then enter the new password again for confirmation.
    Select DONE to enable the new password.
    Default Passwords
    The default passwords listed in the table above are reloaded whenever the password mode is changed
    from disabled to enabled.
    Use this procedure if you forget a custom password.
    Set option switch 2 OFF.
    Cycle power to disable all passwords.
    Set option switch 2 ON.
    Cycle power again to enable default passwords.
    13-102633 Rev. HPage 37
    Tone Commander 40d120 Installation Instructions
    [SETUP]
    Enter New Password: ****
    ReEnter New Password: ****
    NEXT DELETE ABORTDONE 
    						
    							Page 3813-102633 Rev. H
    Tone Commander 40d120 Installation Instructions
    Lucent
    National ISDN
    ®
    123456
    Figure 5– 40d Console Default Key Assignments, Lucent National ISDN 
    						
    							13-102633 Rev. HPage 39
    Tone Commander 40d120 Installation Instructions
    ®
    Figure 6– 40d Console Default Key Assignments, Lucent Custom ISDN
    Lucent
    Custom ISDN 
    						
    							Page 4013-102633 Rev. H
    Tone Commander 40d120 Installation Instructions
    ®
    CALL FWD57
    Figure 7– 40d Console Default Key Assignments, Nortel National ISDN
    Nortel
    National ISDN 
    						
    All Tone Commander manuals Comments (0)

    Related Manuals for Tone Commander 40d120 Installation Instructions