Page 31
1. Install a 6 position, 6 contact modular telephone jack within 6 feet of the console. 2. Label the jack 120 power. 3. Connect a 3 pair cable to the jack and run it to the equipment room. IMPORTANT– Whenever nonkey adapters are used in conjunction with existing multipair cable, verify that the adapters conform to Table 12 above. 4.Only if the colors of your cables differ from the typical colors: fill out Table 12 with the actual wire colors of the cable for each connection. 5. Punch down the cable to...
Page 32
Console Installation Perform the steps in this section for each console position. 30e 120 Page 3213-102499 Rev. G Tone Commander 30e120 Installation Instructions Figure 10 1. Install the handset cradle on the 30e console using the screws provided. The cradle may be installed on either side of the console. 2. Plug the handsets cable into the jack beneath the front left edge of the console. 3. Fill out the keycap labels with line names or numbers (refer to the configuration sheets). Place the labels...
Page 33
Console Line Cords 1. Plug one end of each supplied 6 conductor modular line cord into the “voice/data” and “power” jacks at the back of the 30e console. 2. Plug the line cords into their associated wall jacks, or into the test jacks located on the 30e CPU main circuit board (refer to Figure 1). CAUTION–Do not interchange these two line cords! 3. Plug the supplied short modular line cord into the “data out” jack on the 30e console, and into the “data in” jack on the first 120 console. Do not use a...
Page 34
Preliminary Testing At this time, you should have completed the following: Mounted the CPU and blocks Mounted the power supplies and blocks for console positions #3 and #4 (optional) Installed line and console expansion cards (optional) Installed the cables from the CPU to the blocks Installed the data link cable between 30e and 120 CPUs Connected telco reference ground to 30e and 120 blocks Connected Tip and Ring from each line to the 30e block Connected Tip and Ring from each monitored station...
Page 35
5. Press the RELEASE key. IMPORTANT– Upon the detection of any failure during the foregoing testing, disconnect the affected equipment from the telephone line to determine if such equipment is the cause of failure. Any equipment determined to be malfunctioning must remain disconnected, and use discontinued until the malfunction has been corrected. Hold and Autohold Testing 1. Access the line to be tested and establish call to another station. 2. Place the call on hold by depressing the red HOLD key. The...
Page 36
30e CPU Option Switches SWITCH FUNCTION 1OFF – Autodial Program unlocked ON – Autodial Program locked 2OFF – Configuration Program unlocked ON – Configuration Program locked 3OFF – Name Program unlocked ON – Name Program locked 4OFF – night transfer ON – night ringing 5must be OFF! 6, 7not used 8OFF – retain new programming ON – restore defaults (when power is cycled off & on) Table 14 – CPU Option Switches Switches on the CPU control system programming and Night Service options. The switches are ON...
Page 37
Night Ringing Night ringing is switched on and off during ringing of either lines only, or lines and stations. One of these options must be selected during configuration programming. Tone Commanders PA-24 Paging/Chime Module provides a chime tone that can announce ringing calls over a paging system. This unit is powered from the 30e or 120 CPU. Refer to the PA-24 Paging/Chime Module Installation Instructions, doc. #13-102595. An external bell may be used in place of ringing over a paging system, as shown...
Page 38
Music On Hold An external music source is required for Music On Hold. It will be assigned to the lines during configuration programming. The music input may be connected to any type of compatible music source (refer to the Specifications section). The music source can be connected to the jack provided on the 30e CPU, or punched down to the block. Jack Connections Block Connections Page 3813-102499 Rev. G Tone Commander 30e120 Installation Instructions 1. Connect an RCA-type phono plug to one end of a...
Page 39
Paging Tone Commanders PA-24 Paging/Chime module interfaces the 30e console to a paging system. The module includes a night ringing chime and switching for background music control. Power is derived from the 30e or 120 CPU. Paging can be connected to any spare line key on the 30e. Refer to the PA-24 Paging/Chime Module Installation Instructions, doc. #13-102595. Voice Mail Each station with an associated voice mail box should be call forwarded on no answer to the voice mail system. The DSS dial string...
Page 40
Configuration Programming Various network interface and operation parameters are programmable by the installer, allowing compatibility with a wide variety of central offices and PABXs. The system is pre-programmed at the factory; many installations will require few changes to these values. Programming is retained in the CPUs memory when power is disconnected. When option switch #8 on the 30e CPU isOFF, programming is retained in the 30e CPUs memory when power is disconnected. The programmable parameters...