11 – Machine Control/Location—DTRS devices TASCAM DM-24 Reference Manual 91 DA-78HR This is very similar to the DA-98HR settings dis- played above, except that the eight tracks are always available (since the DA-78HR always has eight tracks available). The main other difference is the inability of the DA-78HR to provide individual input monitoring selection on a per-track basis, and so this feature is not present in the control screen.The digital input selection is between the TDIF1 inputs and the...
Page 92
11 – Machine Control/Location—DTRS devices 92 TASCAM DM-24 Reference Manual DA-38 The DA-38 does not include quite so many options as the DA-98.Input monitoring is not possible, but track copying is available in the same way as for the DA-98. Since the DA-38 does not include a timecode genera- tor, the range of options available in the TC/SYNC sec- tion is more limited, being restricted only to setting the machine offset value. The clock sources are restricted to internal and word. DA-88 This...
Page 93
11 – Machine Control/Location—MIDI controllers TASCAM DM-24 Reference Manual 93 MIDI controllers The PODs of the DM-24 can be used to send MIDI Control Change messages as described here.The most common controllers are listed here, and the cursor keys and PODs are used to set the values of these controllers on the selected channel. The selected channel is shown at the top of the screen, and is the same as the ID selected on the setup page. Control Functions available in this screen are: MIDI faders...
Page 94
11 – Machine Control/Location—MIDI faders 94 TASCAM DM-24 Reference Manual The MIDI faders may be used to control the follow- ing settings: No. Control Function No. Control Function 00 Bank Select 50 GP Controller 3 (LSB) 01 Modulation 51 GP Controller 4 (LSB) 02 Breath Control 52 - 63 Undefined 03 Undefined 64 Damper Pedal (sustain) 04 Foot Controller 65 Portamento On / Off 05 Portamento Time 66 Sostenuto 06 Data entry MSB 67 Soft Pedal 07 Channel Volume 68 Legato Footswitch 08 Balance 69 Hold 2 09...
Page 95
TASCAM DM-24 Reference Manual 95 12 – MIDI The DM-24 can be used for control of MIDI devices, as well as being controlled by them. In the section on machine control, it is explained how the DM-24 can be used to control MIDI devices, using the PODs to transmit different common Con- trol Change messages on a single channel (“MIDI controllers” on page 93) or using the faders to send the same Control Change message on up to 16 differ- ent MIDI channels (“MIDI faders” on page 93).In the section on...
Page 96
12 – MIDI—Updating the system software 96 TASCAM DM-24 Reference Manual At the end of the dump, the popup display shows Done! and then disappears from the screen. Bulk transfer of data to the DM-24 When the appropriate set of data to be dumped to the MIDI device has been selected, move the cursor to the on-screen BULK LOAD button, and press ENTER. A popup message appears, saying that the DM-24 is now ready to receive the selected data. At this point, a cursor key can be pressed to cancel the...
Page 97
12 – MIDI—Control Change messages to and from the DM-24 TASCAM DM-24 Reference Manual 97 To access this facility, use the CTRL. CHANGE (Control Change) screen of the MIDI/MC group, with the fourth soft key providing access to this screen: Use POD 4 to choose the option that will be affected by the selected Control Change numbers. Since there are 32 channels and only 16 MIDI chan- nels, there must be some mapping performed. It is not possible, for example, to use the MIDI volume Control Change (07)...
Page 98
12 – MIDI—MIDI Implementation Chart 98 TASCAM DM-24 Reference Manual MIDI Implementation Chart TEAC [Digital Mixer]DATE : 25 June, :2001 Model:DM-24 MIDI Implementation Chart Version : 1.0 Function Transmitted Recognized Remarks Basic ChannelDefault Changed1-16 1-161-16 1-16Memorized Mode Default Messages Alteredx x ************x x x Note Number True Voicex ************x x Velocity Note On Note Offx xx x After To u c hKey’s Ch’sx xx x Pitch Bend x x Control Change1-5, 7-31, 64-95 0, 6, 32-63-96-119O...
Page 99
TASCAM DM-24 Reference Manual 99 13 – Library functions The DM-24 allows storage of commonly-used set- tings in libraries. The settings that can be stored are: Snapshots EQ settings Internal effector settings (separate groups for effec- tors 1 and 2) Internal dynamics processor settings (both com- pressor and gate/expander) Automation data The procedure for working with all of these libraries is very similar (except for the automation library, which has various different features and is...
Page 100
13 – Library functions—Managing library entries 100 TASCAM DM-24 Reference Manual If the currently-selected entry is read-only (the inverse R is shown), an appropriate error message is displayed and the data is not stored.If data already exists in the library entry, a popup message appears to show that data is already there and will be overwritten. 3In the case of overwriting an existing entry, press ENTER to overwrite the entry, or any of the cursor keys to cancel the operation. Storing entries...