Page 121
16 – Options—TDIF-1 card TASCAM DM-24 Reference Manual 121 High sampling frequency considerations NOTE When cascading, all units must either be in high sam- pling frequency mode or all units must be in normal sampling frequency mode. Because of the reduced number of aux sends, the cas- cade screen changes when the high-frequency mode is selected, as shown here: TDIF-1 card The optional TDIF-1 card provides an additional eight channels of I/O (four in high sampling fre- quency mode).As with the...
Page 122
16 – Options—AES3 card 122 TASCAM DM-24 Reference Manual AES3 card This card allows for the connection of up to four AES input and four output lines.In normal sampling frequency mode, this provides eight audio channels in each direction, and in high sampling frequency mode, it provides four channels in each direction. Input options The inputs may be selected as return sources for channels (“Assigning inputs to channels” on page 38) and the outputs of the cards may be selected as either buss or aux...
Page 123
16 – Options—AD/DA card TASCAM DM-24 Reference Manual 123 The NORMAL option is not available for either input or output in this mode.AES/EBU is the only available output format. AD/DA card This card provides eight balanced channels of analog input and eight balanced channels of analog output, converted at up to 24-bit resolution (the resolution is displayed here, but cannot be changed).The eight output tracks associated with this card can be selected (1-8, 9-16, 17-24). Remember that if this card...
Page 124
124 TASCAM DM-24 Reference Manual 17 – Specifications This section provides technical information about the DM-24. Analog audio I/O All specifications are given with the factory reference level of –16 dBFS. MIC inputs (channels 1 through 16) Balanced XLR-type female connectorsa Adjustable input level (–56 dBu (TRIM max) to –2 dBu (TRIM min)) Input impedance 2.2k Ω PHANTOM (+48V)+48 V phantom power. Switchable in blocks of 4 channels (1–4, 5–8, 9–12, 13–16) LINE IN (BAL) inputs (channels 1 through 16)...
Page 125
17 – Specifications—Digital audio I/O TASCAM DM-24 Reference Manual 125 Digital audio I/O Miscellaneous I/O connections DIGITAL INPUTS (1, 2)2 x XLR-type female connectors (input impedance 110Ω) 2 x RCA pin jacks (input impedance 75 Ω) AES3-1992 or IEC60958 data format (automatically detected) 24-bit word length Switchable sampling frequency conversion available DIGITAL OUTPUTS (1, 2)2 x XLR-type male connectors (output impedance 110Ω 2 x RCA pin jacks (output impedance 75Ω) AES3-1992 or IEC60958 data...
Page 126
17 – Specifications—Equalization 126 TASCAM DM-24 Reference Manual Equalization All filters are fitted with “gain flat” switches System performance Physical characteristics EQ switchOn/Off HIGH filterGain: ±18dB, 0.5dB resolution Frequency: 31 Hz to 19 kHz Q: 0.27 to 8.65 Type: Hi-shelving, Peak, LPF HI MID filterGain: ±18 dB, 0.5 dB resolution Frequency: 31 Hz to 19 kHz Q: 0.27 to 8.65 Type: Peak, Notch LO MID filterGain: ±18 dB, 0.5 dB resolution Frequency: 31 Hz to 19 kHz Q: 0.27 to 8.65 Type: Peak,...
Page 127
17 – Specifications—Dimensional drawing TASCAM DM-24 Reference Manual 127 Dimensional drawing Messages and troubleshooting This provides a list of the messages that you may see on the DM-24, which provide information on the operation that you are performing. Not all of these messages are error messages. “Information” messages, i.e. those which pop up briefly and provide information about a change in status, etc., are marked with a ●.“Confirm” messages, where a response may be nec- essary (usually...
Page 128
17 – Specifications—Messages and troubleshooting 128 TASCAM DM-24 Reference Manual ✖95% of automation memory has been used. Please back up automation data now. Press ENTER to continue.Shown if the automation memory area is too full for future use. Back up unwanted automation banks using MIDI Bulk Dump (“Bulk transfer of data from the DM-24” on page 95), and delete them. ●Already assigned.Shown when an attempt is made to add a device already in the Machine Con- trol List to the list. ✔Assignable...
Page 129
17 – Specifications—Messages and troubleshooting TASCAM DM-24 Reference Manual 129 ✖Can’t do MIDI Bulk Load with timecode runningShown if an attempt is made to load Bulk Data with timecode running (“Bulk transfer of data to the DM-24” on page 96) ✔Can’t assign fader grouping layer.Shown when an invalid fader grouping is attempted (“Grouping layers” on page 71). ✔Can’t assign mute grouping layer.Shown when an invalid mute grouping is attempted (“Grouping layers” on page 71). ✔Can’t Dump MIDI Sys Ex...
Page 130
17 – Specifications—Messages and troubleshooting 130 TASCAM DM-24 Reference Manual ✔Clear all current automation data? Press ENTER to confirm, or a cursor key to cancel.Shown when attempting to clear all current automation memory. ✔Clear this fader grouping? Press ENTER to confirm, or a cursor key to cancel.Shown when the SEL key of a group master is pressed. Pressing ENTER will clear the group (“Grouping” on page 69). ✔Clear this fader grouping? Press ENTER to confirm, or a cursor key to cancel.Shown...