Page 541
Program Mode Entry (Key Station) E-5 Appendix E - Customer Database Programming Program Mode Entry (Key Station) Programming is performed at any 24-button Digital Display Terminal. Programming is always done at this type of station regardless of the class of service or which station has been assigned the attendant(s). To enter the Program Mode: 1. Press the ON/OFF button (optional). LED lights and intercom dial tone sounds. 2. On the dial pad, press [ ][][3][2][2][6] (default password). A...
Page 542
E-6 Database Programming Worksheets Appendix E - Customer Database Programming Database Programming Worksheets Before attempting programming, it is strongly recommended that customer database worksheets be prepared (Refer to “Programming Tables” on page E-11). These worksheets should become part of the permanent record of customer programming. Refer to the following sections when preparing the worksheets. Database Upload/Download Routine The Database Upload/Download Routine (FLASH 86) provides a...
Page 543
Database Upload/Download Routine E-7 Appendix E - Customer Database Programming HYPERTERMINAL -- Uploading a Database File After opening HyperTerminal, and the New Connection screen displays, complete the following steps: 1. Type a connection name and select the appropriate icon, then click . 2. When the Phone Number screen displays, change the setting in the Connect Using box to: Direct to COM1, and then click . 3. Once the COM1 Properties screen displays, change the settings as shown, and then click...
Page 544
E-8 Database Upload/Download Routine Appendix E - Customer Database Programming HYPERTERMINAL -- Downloading a Database File After opening HyperTerminal, and the New Connection screen displays, complete the following steps: 1. Type connection name and select appropriate icon, then click . 2. When the Phone Number screen displays, change the setting in the Connect Using box to: Direct to COM1, and then click . 3. Once the COM1 Properties screen displays, change the settings as shown, and then click ....
Page 545
Database Upload/Download Routine E-9 Appendix E - Customer Database Programming ECOM -- Uploading a Database File After opening ECOM: 1. Press< Alt> + to open COM Port Options. 2. Change COM port settings as follows, and click . Baud Rate = 19.2K Parity = None Data Bits = 8 Stop Bits = 1 Flow Control = no boxes checked, Xon=17, Xoff=19 3. Press and complete the following fields: 4. Press on keyboard or locate file and select Upload. 5. Highlight XMODEM and click . 6. Type or select upload...
Page 546
E-10 Database Upload/Download Routine Appendix E - Customer Database Programming ECOM -- Downloading a Database File After opening ECOM: 1. Press< Alt> + to open COM Port Options. 2. Change COM port settings as follows, and click . Baud Rate = 19.2 Parity = None Data Bits = 8 Stop Bits = 1 Flow Control = no boxes checked, Xon=17, Xoff=19 3. Press and complete the following fields: 4. Press on keyboard or locate file and select Download. 5. Highlight XMODEM and click . 6. Type or select download...
Page 547
Programming TablesE-11 Appendix E - Customer Database Programming Programming Tables Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data FLASH 01System Timers 1 System Hold Recall Timer 000-300 060 sec 2 Exclusive Hold Recall Timer 000-300 180 sec 3 Attendant Recall Timer 00-60 01 min 4 Transfer Recall Timer 000-300045 sec 7 Pause Timer 1-9 2 sec 8 Call Park Recall Timer 000-600 180 sec 9 Conference/DISA Timer 00-99 10 min 10 Paging Time-out Timer 00-60 15 sec...
Page 548
E-12Programming Tables Appendix E - Customer Database Programming FLASH 05System Features 1 Programming 1 Attendant Override Disabled/Enabled Disabled 2 Hold Preference System/Exclusive System 3 External Night Ring Disabled/Enabled Disabled 4 Executive Override Warning Tone Disabled/Enabled Enabled 5 Page Warning Tone Disabled/Enabled Enabled 6 Background Music Channel Disabled/Enabled Enabled 7 Least Cost Routing Disabled/Enabled Disabled 8 Account Codes - Forced Disabled/Enabled Disabled 9 Group...
Page 549
Programming TablesE-13 Appendix E - Customer Database Programming FLASH 06System Features 2 Programming 1 Privacy Release Tone Option Disabled/Enabled Enabled 2 Distinctive CO Ringing Disabled/Enabled Enabled 3 Verified Account Code Disabled/Enabled Disabled 4 Call Forward Display Disabled/Enabled Enabled 5 External Day Ring Disabled/Enabled Disabled 6 Overflow Station Forward Disabled/Enabled Disabled 7 Direct Transfer Mode Disabled/Enabled Enabled 8 Station ID Lock Disabled/Enabled Disabled 9 LCR Call...
Page 550
E-14Programming Tables Appendix E - Customer Database Programming FLASH 07Flash Rates (Programmable) 1 Incoming CO Line Ringing 00-28 Red 480ipm flutter (08) 2 Incoming Intercom Ringing 00-28 Red 120ipm flutter (11) 3 Call Forward Button 00-28 Red Steady On (01) 4 Message Wait/VM Button 00-28 Red Steady On (01) 5 Message CallBack DSS/BLF 00-28 Red 120ipm flutter (11) 6 Do Not Disturb DSS/BLF 00-28 Red 60ipm dbl wink off (04) 7 Auto CallBack DSS/BLF 00-28 Red 120ipm flash (10) 8 ACD/UCD...