Page 51
51 Using the Menus BlankingThis feature allows you to adjust the displayable region within the four directions of the screen. Select each screen edge “left / right / top / bottom” on the Blanking adjustment screen with M / m buttons. Adjust the desired Blanking value with < / , button. When both the “Blanking” and the “V Keystone” are adjusted at the same time, the “Blanking” cannot be adjusted correctly. When using the “Blanking”, make sure that you set the “V Keystone” to “0”. Panel AlignmentThis...
Page 52
52 Information Menu The Information menu displays the model name, serial number, the horizontal and vertical frequencies of the input signal and the cumulated hours of usage of the lamp. fH (horizontal frequency) and fV(vertical frequency) may not be displayed depending on the input signal used on the projector. You cannot change the displays listed above. This projector has 38 types of preset data for input signals (the preset memory). When the preset signal is input, the projector automatically...
Page 53
53 Others This section describes about the other functions, how to solve the problems, how to replace the lamp and air filter, etc. About the HDMI Control What is the HDMI Control? HDMI Control is an HDMI standard mutual control function which uses the HDMI CEC (Consumer Electronics Control) specification. By connecting a variety of HDMI control compatible equipment such as a DVD recorder, an AV amplifier, etc., with an HDMI cable, you can operate your equipment synchronizing with the HDMI...
Page 54
54 D:\job\3218492111\3218492111VPLVW60UC\010GB_VPLVW60UC\0 8OTH.fmmasterpage:Left VPL-VW60 3-218-492- 11 (1) Troubleshooting If the projector appears to be operating erratically, try to diagnose and correct the problem using the following instructions. If the problem persists, consult with qualified Sony personnel. Power Picture Symptom Cause and Remedy The power is not turned on. cAfter about one minute, turn the power on. c Close the lamp cover securely, then tighten the screws securely. (1...
Page 55
55 Others On-screen display Remote control Others Symptom Cause and Remedy The picture flickers.cActivate “APA”, then adjust the current input signal. cAdjust “Phase” for “Adjust Signal” in the Screen menu properly. (1 page 45) The color of characters or the picture is not appropriate.cSelect the desired color registration in “Panel Alignment” of Installation menu (1 page 51). Symptom Cause and Remedy On-screen display does not appear.cSet “Status” in the Setup menu to “On.” (1 page 46)...
Page 56
56 The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any trouble with your projector. When a warning indicator other than the above starts flashing, and the symptom persists even after carrying out the above methods, consult with qualified Sony personnel. Warning Indicators Symptom Cause and Remedy LAMP/COVER flashes in red. (A repetition rate of 2 flashes)cClose the lamp cover securely, then tighten the screws securely. (1 page 58) cClose the filter holder securely. (1 page...
Page 57
57 Others Warning messages Caution messages Message Lists Message Cause and Remedy High temp.! Lamp off in 1 min.cTurn off the power. cCheck to ensure that nothing is blocking the ventilation holes. (1 page 13) Frequency is out of range!cFrequency is out of range. Input a signal that is within the acceptable frequency range of the projector. Please check Input-A Signal Sel.cSet “Input-A Signal Sel.” in the Setup menu to “Computer” when an RGB signal is input from a computer. (1 page 47) Please...
Page 58
58 Replacing the Lamp and the Air Filter and cleaning the Ventilation holes (intake) Tools you need to get started: Standard Phillips screwdriver Cloth (for scratch protection) The lamp used for the light source has a certain lifespan. When the lamp dims, the color balance of the picture becomes strange, or “Please replace the Lamp/Filter.” appears on the screen, the lamp may be exhausted. Replace the lamp with a new one (not supplied) without delay. Use an LMP-H200 Projector Lamp as the...
Page 59
59 Others 4Loosen the three screws on the lamp with the Phillips screwdriver. Hold up the cover release lever, then pull the lamp straight out. 5Ensure you push the new lamp all the way, then securely tighten those three screws on the lamp. Lock the cover release lever and put it back. Be careful not to touch the optical block inside the unit. 6Close the lamp cover, then tighten the screws. 7Remove the filter holder. 8Remove the air filter. NoteClaws
Page 60
60 9Attach the new air filter so that it fits into the each claws (10 positions) on the filter holder. Attach the Air Filter aligning it with the shape of the filter holder. Also, do not touch the fan after removing the air filter that is set deep inside the projector. 10 Attach the filter holder. The projector will not turn on unless the filter holder is securely closed. 11Wipe dust off the Ventilation holes (intake) with a soft cloth. 12Place the project back on its original position. 13Turn...