Sony F65 Manual
Here you can view all the pages of manual Sony F65 Manual. The Sony manuals for Camera are available online for free. You can easily download all the documents as PDF.
Page 61
61VF Menu List Chapter 4 Menu Configuration and Detailed Settings 4-2-7 Diagnosis Menu Remote control settingsAccess Password Disabled Enabled, Disabled Sets access permissions for remote control over a network. sonyf65 (Blank), String of up to 32 characters Sets the password for access via a network. Network settings reset Network Settings -- Execute by Enter. Resets the network settings. PageConfiguration itemDefaultSettingsRemarks Ve r s i o n information display System -- V X.xx...
Page 62
62Metadata Appendix Appendix Metadata The camera and lens metadata is output on the master output, and is recorded on the SR-R4. The output metadata is comprised by metadata in format based on SMPTE RDD18 and non-realtime metadata in proprietary format. Slate information entered using the F65Remote Look Plus application on a tablet device is output in non-realtime metadata. The following metadata items are output. RDD 18 format metadata set Lens unit metadata set Camera unit metadata set Item...
Page 63
63Metadata Appendix Sony F65 camera metadata set Shutter Speed (Angle)UInt32 4 81.08 Shutter angle expressed in minutes (1/60 of a degree). ISO Sensitivity UInt16 2 81.0B ISO sensitivity of the camera. White Balance UInt16 2 81.0E White Balance value defined by the temperature in Kelvin. Capture Gamma Equation Label 16 32.10 Gamma characteristic applied to the main video signal expressed by the label value registered in SMPTE RP 224. Gamma for CDL UInt8 1 81.16 Label value of gamma...
Page 64
64Metadata Appendix Cooke Protocol Lens metadata set Non-realtime metadata Monitoring Base CurveLabel 16 E1.0B Label value, registered in SMPTE RP 224, indicating the base curve when ASC CDL adjustment is added for the monitor video on SDI-OUT1. Monitoring Descriptions UTF8 String 12 E1.09 String indicating the combined SDI-OUT1 monitor characteristic. Example for each SDI1 Look Select setting: ACES-Proxy10: “ACES-Proxy10” Graded ACES: “Graded ACES” Look Profile: “SonyProf1: LC_709”...
Page 65
65Metadata Appendix Length 4-byte length 4 Data length of second packet, excluding the Key and Length attributes. Reel UTF8 String Variable (8 max.)02.01 Reel number. Scene UTF8 String Variable (8 max.)02.02 Scene number. Cut UTF8 String Variable (8 max.)02.03 Cut number. Take UTF8 String Variable (8 max.)02.04 Take number. Shot UTF8 String Variable (8 max.)02.05 Shot number. Camera Index UTF8 String Variable (8 max.)02.06 Index used to indentify the camera used for shooting. Item nameData...
Page 66
66Warning/Error Messages Appendix Warning/Error Messages If the battery voltage drops or an error is detected when power is applied or during operation, the corresponding indicator lights up/flashes and a message appears on the subdisplay. The error details are displayed in the self- diagnostics on settings page 3 on the subdisplay and in the viewfinder. Warnings and error messages occurring on the SR-R4 are also displayed in the self-diagnostics field. For details about SR-R4 messages, refer to...
Page 67
67Warning/Error Messages Appendix DIAGNOSIS: Lit red DOCK: Not litWarning Optical Level No Input No signal is input on the Recorder connector. DIAGNOSIS: Lit red Warning CRCC Error occurred A Cyclic Redundancy Check Code (CRCC) error occurred with the Recorder connector. Clean the recorder connector. If the error continues, even after cleaning, consult your local Sony representative. DIAGNOSIS: Lit red Displays same message as self diagnostics field in a dialog.SR-R4 version mismatch SR-R4...
Page 68
68Precautions Appendix Precautions Use and storage Do not subject the unit to severe shocks The internal mechanism may be damaged or the body warped. Do not block the ventilation holes If the ventilation holes are blocked, not only are the characteristics not guaranteed, but also extreme degradation of the internal parts will likely result, causing defects of the camera. For the locations of the ventilation holes, see the figures in “1-3 Locations and Functions of Parts” (page 12). After use...
Page 69
69Cleaning the Recorder Connector / About “Memory Stick Duo” Appendix Cleaning the Recorder Connector Before cleaning the recorder connector, always check that the power supply is disconnected before proceeding. If the recorder connector is dirty, there is increased risk of errors in the data transmission between the camera and the SR-R4. The recorder connector should be cleaned if any of the following conditions occurs. DOCK indicator is lit yellow or red. DIAGNOSIS indicator is lit red and...
Page 70
70About “Memory Stick Duo” Appendix inserting the “Memory Stick Duo,” and then try inserting it again. To remove a “Memory Stick Duo” Confirm that the access lamp is not flashing red, then lightly push in the “Memory Stick Duo” to release the lock. If the access lamp is flashing red, data is being read from or written to the “Memory Stick Duo” At this time, do not shake the product or subject it to shock. Do not turn off the power to the product or remove the “Memory Stick Duo.” Doing so may...