Page 11

11Example of System Configuration
  Chapter 1   Overview
1-2-1 SR-R4 Docking System
An SR-R4 recorder can be docked on the rear of the camera head.
The SR-R4 power source is supplied via the camera’s DC IN connector. 
HDVF-C30WR or DVF-EL100
12 V DC powerSR-R4 

Page 12

12Locations and Functions of Parts
  Chapter 1   Overview
1-3 Locations and Functions of Parts
Front panel
a (Network) connector (RJ-45 type, 10BASE-T/
100BASE-TX) 
Connects to a network cable when configuring the camera 
from a web browser on a computer. 
For a network cable connection, the IP address must be 
configured in the Network menu in the VF menu. 
For details, see “4-2-6 Network Menu” (page 60). 
 For safety, do not connect the connector for peripheral  device wiring that might have excessive...

Page 13

13Locations and Functions of Parts
  Chapter 1   Overview
Left panel
aUSB connectors
USB 2.0 standard connector. Connect a CBK-WA01 Wi-Fi 
Adapter (optional) to enable communication with wireless 
LAN devices. 
b Accessory receptacles
For mounting accessories using M3 screws. The depth of 
the screws is 5 mm (
7/32 inch). 
c CAM POWER switch
Turns the camera power supply ON/OFF. 
d DC OUT 12V 4A (12 V DC supply output) 
connector
Supplies 12 V DC power source to accessories, when the 
CAM POWER switch...

Page 14

14Locations and Functions of Parts
  Chapter 1   Overview
Right panel
aASSIGN (assignable) buttons
You can assign various functions to these buttons, using 
the subdisplay or the menu displayed in the viewfinder or 
on a monitor.
ASSIGN button 1 is on the far left, and ASSIGN button 4 
is on the far right. 
For details, see “3-3-14 Assigning Functions to the 
ASSIGN Buttons” (page 33).
b DIAGNOSIS indicator
Indicates the diagnostics status. 
Lit green:  Normal
Lit red:  Error
Flashing red:  Fatal error...

Page 15

15Locations and Functions of Parts
  Chapter 1   Overview
Yellow: Caution level 
Sensitivity has decreased, but signal can be transferred 
without error. Clean the recorder connector or replace 
the connector optical module as soon as practicable.
Red:  Light detection error
A light reception problem occurred, and signal cannot 
be transferred correctly. Promptly clean the recorder 
connector or replace the connector optical module.
Off:  No signal 
For details about cleaning the connectors, see...

Page 16

16Locations and Functions of Parts
  Chapter 1   Overview
Rear panel
aRecorder connector
Connects signal and power with the SR-R4 docked on the 
camera. 
Attach the connector cap on the optical connector when 
not connected to an SR-R4 to protect the connector. 
b REC (record) indicator
The indicator is lit red while the recorder is recording. 
You can slide the cover to hide the indicator. 
c GENLOCK IN (external sync signal input) 
connector (BNC type) 
Connects to an external sync signal (HD 3-level...

Page 17

17
  Chapter 2   Installation and Preparations
Chapter
Mounting the SR-R4
2
Installation and 
Preparations
2-1 Mounting the SR-R4
The SR-R4 docks on the rear of the camera head.
For details about mounting the SR-R4, refer to the 
Operation Manual of the SR-R4.
 SR-R4/SRK-CP1 software V3.00 or later is required in order to use the various functions described in this 
manual.
 Always turn off the camera power supply when  mounting the SR-R4.   The recorder connector for connecting the SR-R4 is an 
optical...

Page 18

18Attaching a Filter
  Chapter 2   Installation and Preparations
2-2 Attaching a Filter
You can mount commercially available gel filters in the 
supplied filter holder and then attach them to the camera if 
you wish to use an ND filter in F65RAW-HFR mode or 
wish to use a filter other than those built into the camera.
Recommended filter: Fujifilm neutral density filters
1Place the filter template (metallic disc) on the gel filter, 
then trim the filter around the edge of the filter 
template.
2Remove...

Page 19

19Attaching a Lens
  Chapter 2   Installation and Preparations
2-3 Attaching a Lens
Attach a lens that conforms to the PL lens mount.
Always use a lens whose projection from the flange (A in 
the figure) is less than 31.5 mm (1 
1/4 inch). Use of any lens 
that protrudes more than 31.5 mm (1 1/4 inch) will damage 
the internal filter. 
For information on handling lenses, refer to the operation 
manual for the lens.
1Rotate the lens fixing lever counterclockwise and 
remove the lens mount cap from the...

Page 20

20Attaching a Lens
  Chapter 2   Installation and Preparations
To change a shim
Exercise care not to damage the internal wiring of the 
camera when changing the shim. Modifying a shim, 
scratching a surface, or introducing dust can change the 
flange back distance and damage the camera such that it 
cannot be restored to original condition, just as for a film 
camera. 
1Remove the lens mount screws (6). 
2Pull the lens mount out by about 10 mm (13/32 inch) 
and remove the shim carefully. 
Pass the shim...
Start reading Sony F65 Manual

Related Manuals for Sony F65 Manual

All Sony manuals