Page 11
11Example of System Configuration Chapter 1 Overview 1-2-1 SR-R4 Docking System An SR-R4 recorder can be docked on the rear of the camera head. The SR-R4 power source is supplied via the camera’s DC IN connector. HDVF-C30WR or DVF-EL100 12 V DC powerSR-R4
Page 12
12Locations and Functions of Parts Chapter 1 Overview 1-3 Locations and Functions of Parts Front panel a (Network) connector (RJ-45 type, 10BASE-T/ 100BASE-TX) Connects to a network cable when configuring the camera from a web browser on a computer. For a network cable connection, the IP address must be configured in the Network menu in the VF menu. For details, see “4-2-6 Network Menu” (page 60). For safety, do not connect the connector for peripheral device wiring that might have excessive...
Page 13
13Locations and Functions of Parts Chapter 1 Overview Left panel aUSB connectors USB 2.0 standard connector. Connect a CBK-WA01 Wi-Fi Adapter (optional) to enable communication with wireless LAN devices. b Accessory receptacles For mounting accessories using M3 screws. The depth of the screws is 5 mm ( 7/32 inch). c CAM POWER switch Turns the camera power supply ON/OFF. d DC OUT 12V 4A (12 V DC supply output) connector Supplies 12 V DC power source to accessories, when the CAM POWER switch...
Page 14
14Locations and Functions of Parts Chapter 1 Overview Right panel aASSIGN (assignable) buttons You can assign various functions to these buttons, using the subdisplay or the menu displayed in the viewfinder or on a monitor. ASSIGN button 1 is on the far left, and ASSIGN button 4 is on the far right. For details, see “3-3-14 Assigning Functions to the ASSIGN Buttons” (page 33). b DIAGNOSIS indicator Indicates the diagnostics status. Lit green: Normal Lit red: Error Flashing red: Fatal error...
Page 15
15Locations and Functions of Parts Chapter 1 Overview Yellow: Caution level Sensitivity has decreased, but signal can be transferred without error. Clean the recorder connector or replace the connector optical module as soon as practicable. Red: Light detection error A light reception problem occurred, and signal cannot be transferred correctly. Promptly clean the recorder connector or replace the connector optical module. Off: No signal For details about cleaning the connectors, see...
Page 16
16Locations and Functions of Parts Chapter 1 Overview Rear panel aRecorder connector Connects signal and power with the SR-R4 docked on the camera. Attach the connector cap on the optical connector when not connected to an SR-R4 to protect the connector. b REC (record) indicator The indicator is lit red while the recorder is recording. You can slide the cover to hide the indicator. c GENLOCK IN (external sync signal input) connector (BNC type) Connects to an external sync signal (HD 3-level...
Page 17
17 Chapter 2 Installation and Preparations Chapter Mounting the SR-R4 2 Installation and Preparations 2-1 Mounting the SR-R4 The SR-R4 docks on the rear of the camera head. For details about mounting the SR-R4, refer to the Operation Manual of the SR-R4. SR-R4/SRK-CP1 software V3.00 or later is required in order to use the various functions described in this manual. Always turn off the camera power supply when mounting the SR-R4. The recorder connector for connecting the SR-R4 is an optical...
Page 18
18Attaching a Filter Chapter 2 Installation and Preparations 2-2 Attaching a Filter You can mount commercially available gel filters in the supplied filter holder and then attach them to the camera if you wish to use an ND filter in F65RAW-HFR mode or wish to use a filter other than those built into the camera. Recommended filter: Fujifilm neutral density filters 1Place the filter template (metallic disc) on the gel filter, then trim the filter around the edge of the filter template. 2Remove...
Page 19
19Attaching a Lens Chapter 2 Installation and Preparations 2-3 Attaching a Lens Attach a lens that conforms to the PL lens mount. Always use a lens whose projection from the flange (A in the figure) is less than 31.5 mm (1 1/4 inch). Use of any lens that protrudes more than 31.5 mm (1 1/4 inch) will damage the internal filter. For information on handling lenses, refer to the operation manual for the lens. 1Rotate the lens fixing lever counterclockwise and remove the lens mount cap from the...
Page 20
20Attaching a Lens Chapter 2 Installation and Preparations To change a shim Exercise care not to damage the internal wiring of the camera when changing the shim. Modifying a shim, scratching a surface, or introducing dust can change the flange back distance and damage the camera such that it cannot be restored to original condition, just as for a film camera. 1Remove the lens mount screws (6). 2Pull the lens mount out by about 10 mm (13/32 inch) and remove the shim carefully. Pass the shim...