5-48 Address 16 17 63 84 C5 55 75 07 D3 D6 59 01 FF D0 Data Address 41 42 Data 26 A1 Address 16 17 86 35 33 AA 90 B6 Data Address 41 42 Data 69 73 3-5-2. BIST Check 1. Playback System Check 1-1. Preparation for Playback 1) Set the POWER switch to VTR (or PLAYER) position. 2) Connect the adjusting remote commander and set the HOLD switch to ON (SERVICE) position. 3) Playback the BIST check tape. (XH5-6(NTSC), XH5-6P(PAL)) Note: Perform the following checks in the playback mode. 1-2. IC1814(TRF) BIST(PB) Check 1) Select page: 3, address: 12, set data: 04, and press the PAUSE button. 2) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 3) Select page: 3, address: 13, set data: 02, and press the PAUSE button. 4) When the playback system of IC1814(TRF) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model1-3. IC1601(TFD) BIST(PB) Check 1) Select page: 3, address: 40, set data: 0F, and press the PAUSE button. 2) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 3) When all playback system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 4) Select page: 3, address: 40, set data: 03, and press the PAUSE button. 5) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 6) When the video playback system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 7) Select page: 3, address: 40, set data: 05, and press the PAUSE button. 8) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 9) When the audio playback system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 10) Select page: 3, address: 40, set data: 09, and press the PAUSE button. 11) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 12) When the subcode playback system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model Address 41 42 Data 7C 01 Address 41 42 Data A6 E1 Address 41 42 Data 88 A9 Address 41 42 Data 43 C8 Address 41 42 Data 72 CD Address 41 42 Data 76 A9
![](/img/blank.gif)
5-49 Address 16 17 Data 9A 13 Address 14 15 Data 12 43 Address 16 17 Data FB F4 1-4. IC1600(SFD) BIST(PB) Check 1) Select page: 0, address: 01, and set data: 01. 2) Select page: C, address: AC, set data: 21, and press the PAUSE button. 3) Select page: C, address: AD, set data: 01, and press the PAUSE button. 4) Select page: 3, address: 11, set data: 04, and press the PAUSE button. 5) Select page: 3, address: 12, set data: 08, and press the PAUSE button. 6) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 7) Select page: 3, address: 13, set data: 03, and press the PAUSE button. 8) When the playback system from IC1600(SFD) to IC2002(ADC&DAC) is normal, the display data (combination data) of page: 3, address: 14 and 15 agrees with any combination as shown below. NTSC model PAL model 9) When the playback system from IC1600(SFD) to IC1602(LIP) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model 10) When the playback system from IC1600(SFD) to IC1601(TDF) is normal, the display data (combination data) of page: 3, address: 18 and 19 agrees with any combination as shown below. NTSC model PAL model 11) When the playback system from IC1600(SFD) to IC1501(VFD) is normal, the display data (combination data) of page: 3, address: 1A and 1B agrees with any combination as shown below. NTSC model PAL model 12) Select page: C, address: AC, set data: 20, and press the PAUSE button. 13) Select page: C, address: AD, set data: 00, and press the PAUSE button. 14) Select page: 0, address: 01, and set data: 00. Address 14 15 Data 41 81 1E B4 F0 31 DataAddress 16 17 72 F8 16 5C DataAddress 18 19 Address 1A 1B Data 12 43 Address 14 15 Data 2D 7C Address 16 17 Data 1C A6 Address 18 19 Data A7 CC Address 1A 1B Data 90 CE 1-5. IC1501(VFD) BIST(PB) Check 1) Select page: 0, address: 01, and set data: 01. 2) Select page: C, address: 60, set data: 06, and press the PAUSE button. ¥ VBUS/EX BIST(PB) Check 3) Select page: 3, address: 10, set data: 00, and press the PAUSE button. 4) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 5) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 6) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 7) When the playback system from IC1600(SFD) to IC1501(VFD) is normal, the display data (combination data) of page: 3, address: 14 and 15 agrees with any combination as shown below. NTSC model PAL model 8) When the playback system from IC1501(VFD) to IC756(HONEY) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model ¥ UPY Y BIST(PB) Check 9) Select page: 3, address: 10, set data: 88, and press the PAUSE button. 10) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 11) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 12) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 13) When the playback system from IC1501(VFD) to IC5001,5502 (LCD DRIVER) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model Address 14 15 Data 90 CE Address 16 17 Data 54 ED Address 16 17 Data 03 C9
![](/img/blank.gif)
5-50 ¥ UPY Cr BIST(PB) Check 14) Select page: 3, address: 10, set data: 89, and press the PAUSE button. 15) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 16) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 17) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 18) When the playback system from IC1501(VFD) to IC5001,5502 (LCD DRIVER) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model ¥ UPY Cb BIST(PB) Check 19) Select page: 3, address: 10, set data: 8A, and press the PAUSE button. 20) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 21) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 22) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 23) When the playback system from IC1501(VFD) to IC5001,5502 (LCD DRIVER) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model ¥ Preparation of ENC BIST(PB) Check 24) Select page: C, address: 51, set data: 0F, and press the PAUSE button. ¥ ENC Ya BIST(PB) Check 25) Select page: 3, address: 10, set data: 8B, and press the PAUSE button. 26) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 27) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 28) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 29) When the playback system from IC1501(VFD) to IC1402 (AOI) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model¥ ENC Yb BIST(PB) Check 30) Select page: 3, address: 10, set data: 8C, and press the PAUSE button. 31) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 32) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 33) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 34) When the playback system from IC1501(VFD) to IC1402 (AOI) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model ¥ ENC Ca BIST(PB) Check 35) Select page: 3, address: 10, set data: 8D, and press the PAUSE button. 36) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 37) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 38) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 39) When the playback system from IC1501(VFD) to IC1402 (AOI) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model ¥ ENC Cb BIST(PB) Check 40) Select page: 3, address: 10, set data: 8E, and press the PAUSE button. 41) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 42) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 43) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 44) When the playback system from IC1501(VFD) to IC1402 (AOI) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model 45) Select page: C, address: 51, set data: 03, and press the PAUSE button. 46) Select page: C, address: 60, set data: 0E, and press the PAUSE button. 47) Select page: 0, address: 01, and set data: 00. Address 16 17 Data 1C 60 Address 16 17 Data 92 5A Address 16 17 Data 3C D2 Address 16 17 Data 14 A7 Address 16 17 Data B8 67 Address 16 17 Data 69 21 B2 E7 DE EE DataAddress 16 17 Address 16 17 Data 83 9E FE 68 22 CA DataAddress 16 17 70 D5 43 E4 DataAddress 16 17 ED CB 9A 1E DataAddress 16 17 Address 16 17 Data CC ED
![](/img/blank.gif)
5-51 Address 1A 1B Data D5 0B C2 42 A7 DD DataAddress 41 42 Address 1A 1B Data 34 8A 55 B5 1A 04 DataAddress 41 42 2D F5 A2 7B DataAddress 16 17 6C C7 23 76 DataAddress 18 19 2. Recording System Check 2-1. Preparations for recording 1) Playback the BIST check tape.(XH5-6(NTSC), XH5-6P(PAL)) 2) Select page: 3, address: 10, set data: C0, and press the PAUSE button. 3) Select page: 3, address: 11, set data: 07, and press the PAUSE button. 4) Enter the stop mode. 5) While keep the HOLD switch of the adjusting remote commander at ON(SERVICE) position, eject the BIST check tape and insert a tape for recording in place of the tape. 6) Enter the camera recording mode. Note:Perform the following checks in the camera recording mode. 2-2. IC1501(VFD) BIST(REC) Check 1) Select page: 3, address: 12, set data: 10, and press the PAUSE button. 2) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 3) Select page: 3, address: 13, set data: 04, and press the PAUSE button. 4) When the recording system from IC1501(VFD) to IC1600(SFD) is normal, the display data (combination data) of page: 3, address: 14 and 15 agrees with any combination as shown below. NTSC model PAL model 2-3. IC1600(SFD) BIST(REC) Check 1) Select page: 0, address: 01, and set data: 01. 2) Select page: C, address: AC, set data: 21, and press the PAUSE button. 3) Select page: C, address: AD, set data: 01, and press the PAUSE button. 4) Select page: 3, address: 11, set data: 04, and press the PAUSE button. 5) Select page: 3, address: 12, set data: 08, and press the PAUSE button. 6) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 7) Select page: 3, address: 13, set data: 03, and press the PAUSE button. 8) When the recording system from IC1600(SFD) to IC1602(LIP) is normal, the display data (combination data) of page: 3, address: 16 and 17 agrees with any combination as shown below. NTSC model PAL model 9) When the recording system from IC1600(SFD) to IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 18 and 19 agrees with any combination as shown below. NTSC model PAL model Address 14 15 Data D5 0B 00 15 BC CE DataAddress 16 17 F7 F6 4F 69 DataAddress 18 19 Address 14 15 Data 34 8A 10) When the recording system from IC1501(VFD) to IC1600(SFD) is normal, the display data (combination data) of page: 3, address: 1A and 1B agrees with any combination as shown below. NTSC model PAL model 11) Select page: C, address: AC, set data: 20, and press the PAUSE button. 12) Select page: C, address: AD, set data: 00, and press the PAUSE button. 13) Select page: 0, address: 01, and set data: 00. 2-4. IC1601(TFD) BIST(REC) Check 1) Select page: 3, address: 40, set data: 0F, and press the PAUSE button. 2) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 3) When all recording system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 4) Select page: 3, address: 40, set data: 03, and press the PAUSE button. 5) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 6) When the video recording system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 7) Select page: 3, address: 40, set data: 05, and press the PAUSE button. 8) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 9) When the audio recording system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model 10) Select page: 3, address: 40, set data: 09, and press the PAUSE button. 11) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 12) When the subcode recording system of IC1601(TFD) is normal, the display data (combination data) of page: 3, address: 41 and 42 agrees with any combination as shown below. NTSC model PAL model Address 41 42 Data BB 4E Address 41 42 Data DC ED Address 41 42 Data D7 23 Address 41 42 Data E4 38 Address 41 42 Data D9 3C Address 41 42 Data 47 27
![](/img/blank.gif)
5-52 13) Select page: 3, address: 40, set data: 01, and press the PAUSE button. 14) Select page: 3, address: 40, set data: 00, and press the PAUSE button. 15) When the recording system from IC1601 (TFD) to IC1900 (TRX) is normal, the display data (combination data) of page: 3, address: 43 and 44 agrees with any combination as shown below. NTSC model PAL model 2-5. IC1900(TRX) BIST(REC) Check 1) Select page: 3, address: 12, set data: 04, and press the PAUSE button. 2) Select page: 3, address: 12, set data: 00, and press the PAUSE button. 3) Select page: 3, address: 13, set data: 02, and press the PAUSE button. 4) When all recording system of IC1900 (TRX) is normal, the display data (combination data) of page: 3, address: 14 and 15 agrees with any combination as shown below. NTSC model PAL model 18 F0 C8 FB DataAddress 43 44 96 D1 BC 0E DataAddress 14 15 F6 2A A2 E3 DataAddress 43 44 27 8D B5 61 DataAddress 14 15
![](/img/blank.gif)
5-53 3-6. IR TRANSMITTER ADJUSTMENTS Adjust using a IR receiver jig (J-6082-383-A). Switch setting: LASER LINK ................................... ON (Red LED is lit) 1. IR Video Carrier Frequency Adjustment (VI-151 board) Mode VTR stop Signal Arbitrary Measurement PointPin 5 of CN003 of IR receiver jig (RF) (Or Pin !¤ of IC1403) Measuring Instrument Frequency counter Adjustment Page C Adjustment Address 28 Specified Value f = 11.85 ± 0.05 MHz Connection of Equipment Connect the measuring device as shown in the following figure, and adjust. Fig. 5-3-9. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 08, and press the PAUSE button of the adjustment remote commander. 3) Select page: C, address: 28, change the data, and set the video carrier frequency (f) to the specified value. 4) Press the PAUSE button of the adjustment remote commander. 5) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 6) Select page: 0, address: 01, and set data: 00. 2. IR Video Deviation Adjustment (VI-151 board) Mode VTR stop Signal Arbitrary Measurement PointVIDEO OUT terminal of IR receiver jig (Terminated at 75 W) Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 29 Specified Value A = 1.00 ± 0.05 V Connection of Equipment: Connect the measuring device as shown in the following figure, and adjust. Fig. 5-3-10. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 02, and press the PAUSE button of the adjustment remote commander. 2) Select page: C, address: 29, and change the data, set the video signal amplitude (A) to the specified value. 4) Press the PAUSE button of the adjustment remote commander. 5) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 6) Select page: 0, address: 01, and set data: 00. Main unitIR receiver jig CN003 pin 5Frequency counter Main unit IR receiver jig VIDEO OUT75 ½ 75 ½ (1-247-804-11)Oscilloscope HA Fig. 5-3-11
![](/img/blank.gif)
5-54 3. IR Audio Deviation Adjustment (VI-151 board) Mode VTR stop Signal Video : No signal Audio : Ð400Hz, Ð7.5dBs, Audio left and right terminal of AUDIO/VIDEO jack Measurement Point AUDIO L terminal and AUDIO R terminal of IR receiver jig (Terminated at 47kW) Measuring Instrument Audio level meter Adjustment Page C Adjustment Address 2A Specified Value Signal level: Ð7.5 ± 1.0 dBs Level difference of L and R: Below 2dB Connection of Equipment: Connect the measuring device as shown in the following figure, and adjust. Fig. 5-3-12. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Connect the audio level meter to the AUDIO L terminal of the IR receiver jig. 3) Select page: C, address: 2A, change the data and set the 400Hz audio signal level to the specified value. 4) Press the PAUSE button of the adjustment remote commander. 5) Connect the audio level meter to the AUDIO R terminal of the IR receiver jig. 6) Check that the 400Hz audio signal level is within the specified value. If outside, repeat from step 2). 7) Select page: 0, address: 01, and set data: 00. Main unit Audio oscillator Audio Left (White) Video (Yellow) Audio Right (Red) AttenuatorAUDIO/ VIDEOIR receiver jig AUDIO OUT LR Audio level meter 47k ½ 600 ½ 600 ½: 270 ½ (1-249-410-11) + 330 ½ (1-249-411-11) 47k ½ (1-249-437-11)
![](/img/blank.gif)
5-55 3-7. AUDIO SYSTEM ADJUSTMENTS [Connection of Audio System Measuring Devices] Connect the audio system measuring devices as shown in Fig. 5-3-13. Fig. 5-3-13 Recording (Camera mode) Audio oscillator Attenuator600 ½Left RightMain unit MIC 600 ½: 270 ½ (1-249-410-11) + 330 ½ (1-249-411-11) Main unit AUDIO/ VIDEO OUTLeft (White) Right 47k ½ 47k ½ Video (Yellow)TV monitor Audio level meter or Distortion meter 47k ½ (1-249-437-11) Playback (Red)
![](/img/blank.gif)
5-56 1. Playback Level Check Mode VTR playback Signal Alignment tape: For audio operation check (XH5-3 (NTSC)) (XH5-3P (PAL)) Measurement Point Audio left or right terminal of AUDIO VIDEO jack Measuring Instrument Audio level meter and frequency counter Specified Value 32 kHz mode: 1 kHz, +3.0 ± 2.0dBs 48 kHz mode: 1 kHz, +3.0 ± 2.0dBs 44.1 kHz mode: The 7.35kHz signal level during EMP OFF is +2.0 ± 2.0dBs. The 7.35kHz signal level during EMP ON is Ð6 ± 2 dB from the signal level during EMP OFF. Checking Method: 1) Check that the playback signal level is the specified value. 2. Overall Level Characteristics Check Mode Camera recording and playback Signal 400Hz, Ð66 dBs signal: MIC jack left and right Measurement Point Audio left or right terminal of AUDIO VIDEO jack Measuring Instrument Audio level meter Specified Value Ð7.5 ± 3.0dBs Checking Method: 1) Input the 400Hz, Ð66dBs signal in the MIC jack. 2) Record in the camera mode. 3) Playback the recorded section. 4) Check that the 400Hz signal level is the specified value. 3. Overall Distortion Check Mode Camera recording and playback Signal 400Hz, Ð66dBs signal: MIC jack left and right Measurement Point Audio left or right terminal of AUDIO VIDEO jack Measuring Instrument Audio distortion meter Specified Value Below 0.4% (200Hz to 6kHz BPF ON) Checking Method: 1) Input the 400Hz, Ð66dBs signal in the MIC jack. 2) Record in the camera mode. 3) Playback the recorded section. 4) Check that the distortion is the specified value. 4. Overall Noise Level Check Mode Camera recording and playback Signal No signal: Insert a shorting plug in the MIC jack Measurement Point Audio left or right terminal of AUDIO VIDEO jack Measuring Instrument Audio level meter Specified Value Below Ð45dBs (IHF-A filter ON, 20kHz LPF ON) Checking Method: 1) Insert a shorting plug in the MIC jack. 2) Record in the camera mode. 3) Playback the recorded section. 4) Check that the noise level is the specified value. 5. Overall Separation Check Mode Camera recording and playback Signal 400Hz, Ð66dBs signal: MIC jack [left] (Connect the MIC jack [right] to GND) Measurement Point Audio [right] terminal of AUDIO VIDEO jack Measuring Instrument Audio level meter Specified Value Below Ð40dBs (IHF-A filter ON) < > : Left channel check [ ] : Right channel check Checking Method: 1) Input the 400Hz, Ð66dBs signal in the [left] terminal of the MIC jack only. 2) Record in the camera mode. 3) Playback the recorded section. 4) Check that the signal level of the audio [right] terminal is the specified value.
![](/img/blank.gif)
5-57 5-4. SERVICE MODE 4-1. ADJUSTMENT REMOTE COMMANDER The adjustment remote commander is used for changing the calculation coefficient in signal processing, EVR data, etc. The adjustment remote commander performs bi-directional communication with the unit using the remote commander signal line (LANC). The resultant data of this bi-directional communication is written in the non-volatile memory. 1. Using the adjustment remote commander 1) Connect the adjustment remote commander to the LANC terminal. 2) Set the HOLD switch of the adjustment remote commander to ÒHOLDÓ (SERVICE position). If it has been properly connected, the LCD on the adjustment remote commander will display as shown in Fig. 5-4-1. Fig. 5-4-1 3) Operate the adjustment remote commander as follows. ¥ Changing the page The page increases when the EDIT SEARCH+ button is pressed, and decreases when the EDIT SEARCHÐ button is pressed. There are altogether 16 pages, from 0 to F. ¥ Changing the address The address increases when the FF ()) button is pressed, and decreases when the REW (0) button is pressed. There are altogether 256 addresses, from 00 to FF. ¥ Changing the data (Data setting) The data increases when the PLAY (() button is pressed, and decreases when the STOP (p) button is pressed. There are altogether 256 data, from 00 to FF. ¥ Writing the adjustment data The PAUSE button must be pressed to write the adjustment data (B, C, D, F page) in the nonvolatile memory. (The new adjusting data will not be recorded in the nonvolatile memory if this step is not performed.) 4) After completing all adjustments, turn off the main power supply (8.4V) once. PageDataAddress Hexadecimal notation LCD Display Decimal notation conversion value 0123456789ABCDEF 0123456789AbcdEF 0123456789101112131415 2. Precautions upon using the adjustment remote commander Mishandling of the adjustment remote commander may erase the correct adjustment data at times. To prevent this, it is recommended that all adjustment data be noted down before beginning adjustments and new adjustment data after each adjustment.