    							5-48
    Address
    16
    17
    63
    84
    C5
    55
    75
    07
    D3
    D6
    59
    01
    FF
    D0
    Data
    Address
    41
    42
    Data
    26
    A1
    Address
    16
    17
    86
    35
    33
    AA
    90
    B6
    Data
    Address
    41
    42
    Data
    69
    73
    3-5-2. BIST Check
    1. Playback System Check
    1-1. Preparation for Playback
    1) Set the POWER switch to VTR (or PLAYER) position.
    2) Connect the adjusting remote commander and set the HOLD
    switch to ON (SERVICE) position.
    3) Playback the BIST check tape. (XH5-6(NTSC), XH5-6P(PAL))
    Note: Perform the following checks in the playback mode.
    1-2. IC1814(TRF) BIST(PB) Check
    1) Select page: 3, address: 12, set data: 04, and press the PAUSE
    button.
    2) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    3) Select page: 3, address: 13, set data: 02, and press the PAUSE
    button.
    4) When the playback system of IC1814(TRF) is normal, the
    display data (combination data) of page: 3, address: 16 and 17
    agrees with any combination as shown below.
    NTSC model
    PAL model1-3. IC1601(TFD) BIST(PB) Check
    1) Select page: 3, address: 40, set data: 0F, and press the PAUSE
    button.
    2) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    3) When all playback system of IC1601(TFD) is normal, the
    display data (combination data) of page: 3, address: 41 and 42
    agrees with any combination as shown below.
    NTSC  model PAL model
    4) Select page: 3, address: 40, set data: 03, and press the PAUSE
    button.
    5) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    6) When the video playback system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    7) Select page: 3, address: 40, set data: 05, and press the PAUSE
    button.
    8) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    9) When the audio playback system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    10) Select page: 3, address: 40, set data: 09, and press the PAUSE
    button.
    11) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    12) When the subcode playback system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    Address
    41
    42
    Data
    7C
    01
    Address
    41
    42
    Data
    A6
    E1
    Address
    41
    42
    Data
    88
    A9
    Address
    41
    42
    Data
    43
    C8
    Address
    41
    42
    Data
    72
    CD
    Address
    41
    42
    Data
    76
    A9 
    						
    							5-49
    Address
    16
    17
    Data
    9A
    13
    Address
    14
    15
    Data
    12
    43
    Address
    16
    17
    Data
    FB
    F4
    1-4. IC1600(SFD) BIST(PB) Check
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: C, address: AC, set data: 21, and press the PAUSE
    button.
    3) Select page: C, address: AD, set data: 01, and press the PAUSE
    button.
    4) Select page: 3, address: 11, set data: 04, and press the PAUSE
    button.
    5) Select page: 3, address: 12, set data: 08, and press the PAUSE
    button.
    6) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    7) Select page: 3, address: 13, set data: 03, and press the PAUSE
    button.
    8) When the playback system from IC1600(SFD) to
    IC2002(ADC&DAC) is normal, the display data (combination
    data) of page: 3, address: 14 and 15 agrees with any combination
    as shown below.
    NTSC  model PAL model
    9) When the playback system from IC1600(SFD) to IC1602(LIP)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model
    10) When the playback system from IC1600(SFD) to IC1601(TDF)
    is normal, the display data (combination data) of page: 3,
    address: 18 and 19 agrees with any combination as shown
    below.
    NTSC  model PAL model
    11) When the playback system from IC1600(SFD) to IC1501(VFD)
    is normal, the display data (combination data) of page: 3,
    address: 1A and 1B agrees with any combination as shown
    below.
    NTSC  model PAL model
    12) Select page: C, address: AC, set data: 20, and press the PAUSE
    button.
    13) Select page: C, address: AD, set data: 00, and press the PAUSE
    button.
    14) Select page: 0, address: 01, and set data: 00.
    Address
    14
    15
    Data
    41
    81
    1E
    B4
    F0
    31
    DataAddress
    16
    17
    72
    F8
    16
    5C
    DataAddress
    18
    19
    Address
    1A
    1B
    Data
    12
    43
    Address
    14
    15
    Data
    2D
    7C
    Address
    16
    17
    Data
    1C
    A6
    Address
    18
    19
    Data
    A7
    CC
    Address
    1A
    1B
    Data
    90
    CE
    1-5. IC1501(VFD) BIST(PB) Check
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: C, address: 60, set data: 06, and press the PAUSE
    button.
    ¥ VBUS/EX BIST(PB) Check
    3) Select page: 3, address: 10, set data: 00, and press the PAUSE
    button.
    4) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    5) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    6) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    7) When the playback system from IC1600(SFD) to IC1501(VFD)
    is normal, the display data (combination data) of page: 3,
    address: 14 and 15 agrees with any combination as shown
    below.
    NTSC  model PAL model
    8) When the playback system from IC1501(VFD) to
    IC756(HONEY) is normal, the display data (combination data)
    of page: 3, address: 16 and 17 agrees with any combination as
    shown below.
    NTSC  model PAL model
    ¥ UPY Y BIST(PB) Check
    9) Select page: 3, address: 10, set data: 88, and press the PAUSE
    button.
    10) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    11) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    12) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    13) When the playback system from IC1501(VFD) to IC5001,5502
    (LCD DRIVER) is normal, the display data (combination data)
    of page: 3, address: 16 and 17 agrees with any combination as
    shown below.
    NTSC  model PAL model
    Address
    14
    15
    Data
    90
    CE
    Address
    16
    17
    Data
    54
    ED
    Address
    16
    17
    Data
    03
    C9 
    						
    							5-50
    ¥ UPY Cr BIST(PB) Check
    14) Select page: 3, address: 10, set data: 89, and press the PAUSE
    button.
    15) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    16) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    17) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    18) When the playback system from IC1501(VFD) to IC5001,5502
    (LCD DRIVER) is normal, the display data (combination data)
    of page: 3, address: 16 and 17 agrees with any combination as
    shown below.
    NTSC  model PAL model
    ¥ UPY Cb BIST(PB) Check
    19) Select page: 3, address: 10, set data: 8A, and press the PAUSE
    button.
    20) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    21) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    22) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    23) When the playback system from IC1501(VFD) to IC5001,5502
    (LCD DRIVER) is normal, the display data (combination data)
    of page: 3, address: 16 and 17 agrees with any combination as
    shown below.
    NTSC  model PAL model
    ¥ Preparation of ENC BIST(PB) Check
    24) Select page: C, address: 51, set data: 0F, and press the PAUSE
    button.
    ¥ ENC Ya BIST(PB) Check
    25) Select page: 3, address: 10, set data: 8B, and press the PAUSE
    button.
    26) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    27) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    28) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    29) When the playback system from IC1501(VFD) to IC1402 (AOI)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model¥ ENC Yb BIST(PB) Check
    30) Select page: 3, address: 10, set data: 8C, and press the PAUSE
    button.
    31) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    32) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    33) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    34) When the playback system from IC1501(VFD) to IC1402 (AOI)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model
    ¥ ENC Ca BIST(PB) Check
    35) Select page: 3, address: 10, set data: 8D, and press the PAUSE
    button.
    36) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    37) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    38) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    39) When the playback system from IC1501(VFD) to IC1402 (AOI)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model
    ¥ ENC Cb BIST(PB) Check
    40) Select page: 3, address: 10, set data: 8E, and press the PAUSE
    button.
    41) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    42) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    43) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    44) When the playback system from IC1501(VFD) to IC1402 (AOI)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model
    45) Select page: C, address: 51, set data: 03, and press the PAUSE
    button.
    46) Select page: C, address: 60, set data: 0E, and press the PAUSE
    button.
    47) Select page: 0, address: 01, and set data: 00.
    Address
    16
    17
    Data
    1C
    60
    Address
    16
    17
    Data
    92
    5A
    Address
    16
    17
    Data
    3C
    D2
    Address
    16
    17
    Data
    14
    A7
    Address
    16
    17
    Data
    B8
    67
    Address
    16
    17
    Data
    69
    21
    B2
    E7
    DE
    EE
    DataAddress
    16
    17
    Address
    16
    17
    Data
    83
    9E
    FE
    68
    22
    CA
    DataAddress
    16
    17
    70
    D5
    43
    E4
    DataAddress
    16
    17
    ED
    CB
    9A
    1E
    DataAddress
    16
    17
    Address
    16
    17
    Data
    CC
    ED 
    						
    							5-51
    Address
    1A
    1B
    Data
    D5
    0B
    C2
    42
    A7
    DD
    DataAddress
    41
    42
    Address
    1A
    1B
    Data
    34
    8A
    55
    B5
    1A
    04
    DataAddress
    41
    42
    2D
    F5
    A2
    7B
    DataAddress
    16
    17
    6C
    C7
    23
    76
    DataAddress
    18
    19 2. Recording System Check
    2-1. Preparations for recording
    1) Playback the BIST check tape.(XH5-6(NTSC), XH5-6P(PAL))
    2) Select page: 3, address: 10, set data: C0, and press the PAUSE
    button.
    3) Select page: 3, address: 11, set data: 07, and press the PAUSE
    button.
    4) Enter the stop mode.
    5) While keep the HOLD switch of the adjusting remote
    commander at ON(SERVICE) position, eject the BIST check
    tape and insert a tape for recording in place of the tape.
    6) Enter the camera recording mode.
    Note:Perform the following checks in the camera recording
    mode.
    2-2. IC1501(VFD) BIST(REC) Check
    1) Select page: 3, address: 12, set data: 10, and press the PAUSE
    button.
    2) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    3) Select page: 3, address: 13, set data: 04, and press the PAUSE
    button.
    4) When the recording system from IC1501(VFD) to
    IC1600(SFD) is normal, the display data (combination data)
    of page: 3, address: 14 and 15 agrees with any combination as
    shown below.
    NTSC  model PAL model
    2-3. IC1600(SFD) BIST(REC) Check
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: C, address: AC, set data: 21, and press the PAUSE
    button.
    3) Select page: C, address: AD, set data: 01, and press the PAUSE
    button.
    4) Select page: 3, address: 11, set data: 04, and press the PAUSE
    button.
    5) Select page: 3, address: 12, set data: 08, and press the PAUSE
    button.
    6) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    7) Select page: 3, address: 13, set data: 03, and press the PAUSE
    button.
    8) When the recording system from IC1600(SFD) to IC1602(LIP)
    is normal, the display data (combination data) of page: 3,
    address: 16 and 17 agrees with any combination as shown
    below.
    NTSC  model PAL model
    9) When the recording system from IC1600(SFD) to
    IC1601(TFD) is normal, the display data (combination data)
    of page: 3, address: 18 and 19 agrees with any combination as
    shown below.
    NTSC  model PAL model
    Address
    14
    15
    Data
    D5
    0B
    00
    15
    BC
    CE
    DataAddress
    16
    17
    F7
    F6
    4F
    69
    DataAddress
    18
    19
    Address
    14
    15
    Data
    34
    8A
    10) When the recording system from IC1501(VFD) to
    IC1600(SFD) is normal, the display data (combination data)
    of page: 3, address: 1A and 1B agrees with any combination as
    shown below.
    NTSC  model PAL model
    11) Select page: C, address: AC, set data: 20, and press the PAUSE
    button.
    12) Select page: C, address: AD, set data: 00, and press the PAUSE
    button.
    13) Select page: 0, address: 01, and set data: 00.
    2-4. IC1601(TFD) BIST(REC) Check
    1) Select page: 3, address: 40, set data: 0F, and press the PAUSE
    button.
    2) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    3) When all recording system of IC1601(TFD) is normal, the
    display data (combination data) of page: 3, address: 41 and 42
    agrees with any combination as shown below.
    NTSC  model PAL model
    4) Select page: 3, address: 40, set data: 03, and press the PAUSE
    button.
    5) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    6) When the video recording system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    7) Select page: 3, address: 40, set data: 05, and press the PAUSE
    button.
    8) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    9) When the audio recording system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    10) Select page: 3, address: 40, set data: 09, and press the PAUSE
    button.
    11) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    12) When the subcode recording system of IC1601(TFD) is normal,
    the display data (combination data) of page: 3, address: 41 and
    42 agrees with any combination as shown below.
    NTSC  model PAL model
    Address
    41
    42
    Data
    BB
    4E
    Address
    41
    42
    Data
    DC
    ED
    Address
    41
    42
    Data
    D7
    23
    Address
    41
    42
    Data
    E4
    38
    Address
    41
    42
    Data
    D9
    3C
    Address
    41
    42
    Data
    47
    27 
    						
    							5-52
    13) Select page: 3, address: 40, set data: 01, and press the PAUSE
    button.
    14) Select page: 3, address: 40, set data: 00, and press the PAUSE
    button.
    15) When the recording system from IC1601 (TFD) to IC1900
    (TRX) is normal, the display data (combination data) of page:
    3, address: 43 and 44 agrees with any combination as shown
    below.
    NTSC  model PAL model
    2-5. IC1900(TRX) BIST(REC) Check
    1) Select page: 3, address: 12, set data: 04, and press the PAUSE
    button.
    2) Select page: 3, address: 12, set data: 00, and press the PAUSE
    button.
    3) Select page: 3, address: 13, set data: 02, and press the PAUSE
    button.
    4) When all recording system of IC1900 (TRX) is normal, the
    display data (combination data) of page: 3, address: 14 and 15
    agrees with any combination as shown below.
    NTSC  model PAL model
    18
    F0
    C8
    FB
    DataAddress
    43
    44
    96
    D1
    BC
    0E
    DataAddress
    14
    15
    F6
    2A
    A2
    E3
    DataAddress
    43
    44
    27
    8D
    B5
    61
    DataAddress
    14
    15 
    						
    							5-53 3-6. IR TRANSMITTER ADJUSTMENTS
    Adjust using a IR receiver jig (J-6082-383-A).
    Switch setting:
    LASER LINK ................................... ON (Red LED is lit)
    1. IR Video Carrier Frequency Adjustment
        (VI-151 board)
    Mode VTR stop
    Signal Arbitrary
    Measurement PointPin 5 of CN003 of IR receiver jig (RF)
    (Or Pin !¤ of IC1403)
    Measuring Instrument Frequency counter
    Adjustment Page C
    Adjustment Address 28
    Specified Value f = 11.85 ± 0.05 MHz
    Connection of Equipment
    Connect the measuring device as shown in the following figure,
    and adjust.
    Fig. 5-3-9.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 08, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: C, address: 28, change the data, and set the video
    carrier frequency (f) to the specified value.
    4) Press the PAUSE button of the adjustment remote commander.
    5) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    6) Select page: 0, address: 01, and set data: 00.
    2. IR Video Deviation Adjustment (VI-151 board)
    Mode VTR stop
    Signal Arbitrary
    Measurement PointVIDEO OUT terminal of IR receiver jig
    (Terminated at 75 W)
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 29
    Specified Value A = 1.00 ± 0.05 V
    Connection of Equipment:
    Connect the measuring device as shown in the following figure,
    and adjust.
    Fig. 5-3-10.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    2) Select page: C, address: 29, and change the data, set the video
    signal amplitude (A) to the specified value.
    4) Press the PAUSE button of the adjustment remote commander.
    5) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    6) Select page: 0, address: 01, and set data: 00.
    Main unitIR receiver jig
    CN003
    pin 
    5Frequency counter
    Main unit IR receiver jig
    VIDEO 
    OUT75 ½ 
    75 
    ½ (1-247-804-11)Oscilloscope
    HA
    Fig. 5-3-11 
    						
    							5-54
    3. IR Audio Deviation Adjustment (VI-151 board)
    Mode VTR stop
    Signal Video : No signal
    Audio : Ð400Hz, Ð7.5dBs, Audio left
    and right terminal of AUDIO/VIDEO
    jack
    Measurement Point AUDIO L terminal and AUDIO R
    terminal of IR receiver jig
    (Terminated at 47kW)
    Measuring Instrument Audio level meter
    Adjustment Page C
    Adjustment Address 2A
    Specified Value Signal level: Ð7.5 ± 1.0 dBs
    Level difference of L and R: Below
    2dB
    Connection of Equipment:
    Connect the measuring device as shown in the following figure,
    and adjust.
    Fig. 5-3-12.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Connect the audio level meter to the AUDIO L terminal of the
    IR receiver jig.
    3) Select page: C, address: 2A, change the data and set the 400Hz
    audio signal level to the specified value.
    4) Press the PAUSE button of the adjustment remote commander.
    5) Connect the audio level meter to the AUDIO R terminal of the
    IR receiver jig.
    6) Check that the 400Hz audio signal level is within the specified
    value. If outside, repeat from step 2).
    7) Select page: 0, address: 01, and set data: 00.
    Main unit
    Audio oscillator
    Audio Left
    (White) Video
    (Yellow)
    Audio Right
    (Red) AttenuatorAUDIO/
    VIDEOIR receiver jig
    AUDIO OUT
    LR
    Audio level meter
    47k 
    ½
    600 ½
    600 ½: 270 ½ (1-249-410-11) + 330 ½ (1-249-411-11)
    47k 
    ½ (1-249-437-11) 
    						
    							5-55 3-7. AUDIO SYSTEM ADJUSTMENTS
    [Connection of Audio System Measuring Devices]
    Connect the audio system measuring devices as shown in Fig. 5-3-13.
    Fig. 5-3-13
    Recording (Camera mode)
    Audio oscillator
    Attenuator600 ½Left
    RightMain unit
    MIC
    600 
    ½: 270 ½ (1-249-410-11) + 330 ½ (1-249-411-11)
    Main unit
    AUDIO/
    VIDEO
    OUTLeft (White)
    Right 47k 
    ½
    47k ½
    Video (Yellow)TV monitor
    Audio level meter
    or Distortion meter
    47k 
    ½ (1-249-437-11)
    Playback
    (Red) 
    						
    							5-56
    1. Playback Level Check
    Mode VTR playback
    Signal Alignment tape:
    For audio operation check
    (XH5-3 (NTSC))
    (XH5-3P (PAL))
    Measurement Point Audio left or right terminal of AUDIO
    VIDEO jack
    Measuring Instrument Audio level meter and frequency
    counter
    Specified Value 32 kHz mode: 1 kHz, +3.0 ± 2.0dBs
    48 kHz mode: 1 kHz, +3.0 ± 2.0dBs
    44.1 kHz mode:
    The 7.35kHz signal level during EMP
    OFF is +2.0 ± 2.0dBs.
    The 7.35kHz signal level during EMP
    ON is Ð6 ± 2 dB from the signal level
    during EMP OFF.
    Checking Method:
    1) Check that the playback signal level is the specified value.
    2. Overall Level Characteristics Check
    Mode Camera recording and playback
    Signal 400Hz, Ð66 dBs signal: MIC jack left
    and right
    Measurement Point Audio left or right terminal of AUDIO
    VIDEO jack
    Measuring Instrument Audio level meter
    Specified Value Ð7.5 ± 3.0dBs
    Checking Method:
    1) Input the 400Hz, Ð66dBs signal in the MIC jack.
    2) Record in the camera mode.
    3) Playback the recorded section.
    4) Check that the 400Hz signal level is the specified value.
    3. Overall Distortion Check
    Mode Camera recording and playback
    Signal 400Hz, Ð66dBs signal: MIC jack left
    and right
    Measurement Point Audio left or right terminal of AUDIO
    VIDEO jack
    Measuring Instrument Audio distortion meter
    Specified Value Below 0.4%
    (200Hz to 6kHz BPF ON)
    Checking Method:
    1) Input the 400Hz, Ð66dBs signal in the MIC jack.
    2) Record in the camera mode.
    3) Playback the recorded section.
    4) Check that the distortion is the specified value.
    4. Overall Noise Level Check
    Mode Camera recording and playback
    Signal No signal: Insert a shorting plug in the
    MIC jack
    Measurement Point Audio left or right terminal of AUDIO
    VIDEO jack
    Measuring Instrument Audio level meter
    Specified Value Below Ð45dBs
    (IHF-A filter ON, 20kHz LPF ON)
    Checking Method:
    1) Insert a shorting plug in the MIC jack.
    2) Record in the camera mode.
    3) Playback the recorded section.
    4) Check that the noise level is the specified value.
    5. Overall Separation Check
    Mode Camera recording and playback
    Signal 400Hz, Ð66dBs signal: MIC jack
     [left]
    (Connect the MIC jack  [right]
    to GND)
    Measurement Point Audio  [right] terminal of
    AUDIO VIDEO jack
    Measuring Instrument Audio level meter
    Specified Value Below Ð40dBs (IHF-A filter ON)
    < > : Left channel check
    [   ] : Right channel check
    Checking Method:
    1) Input the 400Hz, Ð66dBs signal in the  [left] terminal
    of the MIC jack only.
    2) Record in the camera mode.
    3) Playback the recorded section.
    4) Check that the signal level of the audio  [right] terminal
    is the specified value. 
    						
    							5-57
    5-4. SERVICE MODE
    4-1. ADJUSTMENT REMOTE COMMANDER
    The adjustment remote commander is used for changing the
    calculation coefficient in signal processing, EVR data, etc. The
    adjustment remote commander performs bi-directional
    communication with the unit using the remote commander signal
    line (LANC). The resultant data of this bi-directional communication
    is written in the non-volatile memory.
    1. Using the adjustment remote commander
    1) Connect the adjustment remote commander to the LANC
    terminal.
    2) Set the HOLD switch of the adjustment remote commander to
    ÒHOLDÓ (SERVICE position). If it has been properly
    connected, the LCD on the adjustment remote commander will
    display as shown in Fig. 5-4-1.
    Fig. 5-4-1
    3) Operate the adjustment remote commander as follows.
    ¥ Changing the page
    The page increases when the EDIT SEARCH+ button is
    pressed, and decreases when the EDIT SEARCHÐ button is
    pressed. There are altogether 16 pages, from 0 to F.
    ¥ Changing the address
    The address increases when the FF ()) button is pressed,
    and decreases when the REW (0) button is pressed. There
    are altogether 256 addresses, from 00 to FF.
    ¥ Changing the data (Data setting)
    The data increases when the PLAY (() button is pressed,
    and decreases when the STOP (p) button is pressed. There
    are altogether 256 data, from 00 to FF.
    ¥ Writing the adjustment data
    The PAUSE button must be pressed to write the adjustment
    data (B, C, D, F page) in the nonvolatile memory. (The new
    adjusting data will not be recorded in the nonvolatile memory
    if this step is not performed.)
    4) After completing all adjustments, turn off the main power
    supply (8.4V) once.
    PageDataAddress
    Hexadecimal
    notation
    LCD Display
    Decimal notation
    conversion value
    0123456789ABCDEF
    0123456789AbcdEF
    0123456789101112131415
    2. Precautions upon using
        the adjustment remote commander
    Mishandling of the adjustment remote commander may erase the
    correct adjustment data at times. To prevent this, it is recommended
    that all adjustment data be noted down before beginning adjustments
    and new adjustment data after each adjustment. 
    						
    All Sony manuals Comments (0)