Home > Sony > Digital Camcorder > Sony Dcrtrv890e Manual

Sony Dcrtrv890e Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sony Dcrtrv890e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							5-38
    Table. 5-3-3
    Address
    89
    8A
    8B
    8C
    8D
    8E
    8F
    90 to FF
    Initial value
    NTSC
    58
    62
    PA L
    58
    62
    Remark
    Fixed data-1
    Bright adj.(LCD)
    Fixed data-2
    Contrast adj.(LCD)
    Fixed data-2
    Fixed data-1
    7. Initializing the B Page DataNote:If the B page data is initialized, the following adjustments must be
    performed again.
    1) Modification of B page data
    Adjusting page B
    Adjusting Address 00 to DF
    Initializing Method:
    1) Set the power switch to the MEMORY position.
    2) Select page: 0, address: 01, and set data: 01.
    3) Select page: 2, address: 8F, set data: 03, and press the PAUSE
    button.
    4) Select page: 2, address: 8F, set data: 00, and press the PAUSE
    button.
    5) Select page: 5, address: 01, set data: F3, and press the PAUSE
    button.
    6) Select page: 5, address: 00, set data: 01, and press the PAUSE
    button.
    7) Select page: 5, address: 02, and check that the data is Ò00Ó.
    8) Perform ÒModification of B Page DataÓ.
    8. Modification of B Page Data
    If the B Page data has been initialized, change the data of the ÒFixed
    data-2Ó address shown in the following tables by manual input.
    Processing before Modification of B Page data
    1) Select page: 2, address: 8F, set data: 03, and press the PAUSE
    button.
    2) Select page: 2, address: 8F, set data: 00, and press the PAUSE
    button .
    Modifying Method:
    1) Before changing the data, select page: 0, address: 01, and set
    data: 01.
    2) New data for changing are not shown in the tables because
    they are different in destination. When changing the data, copy
    the data built in the same model.
    Note:If copy the data built in the different model, the camcorder may
    not operate.
    3) When changing the data, press the PAUSE button of the
    adjustment remote commander each time when setting new
    data to write the data in the non-volatile memory.
    Processing after Completing Modification of B Page data
    1) Select page: 2, address: 00, and set data: 29.
    2) Select page: 2, address: 01, and set data: 29, and press the
    PAUSE button of the adjustment remote commander.9. B Page Table
    Note 1:Fixed data-1 : Initialized data. ( Refer to Ò7. Initializing the B
    Page DataÓ.)
    Fixed data-2 : Modified data. (Refer to Ò8. Modification of B PAGE
    DataÓ).
    Address
    00
    01
    02
    03
    04
    05
    06
    07
    08
    09
    0A
    0B
    0C
    0D
    0E
    0F
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    1A
    1B
    1C
    1D
    1E
    1F
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    2A
    2B
    2C
    2D
    2E
    2F
    30
    31
    32
    Remark
    Fixed data-1
    (Initialized data) 
    						
    							5-39
    Address
    33
    34
    35
    36
    37
    38
    39
    3A
    3B
    3C
    3D
    3E
    3F
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    4A
    4B
    4C
    4D
    4E
    4F
    50
    51
    52
    53
    54
    55
    56
    57
    58
    59
    5A
    5B
    5C
    5D
    5E
    5F
    60
    61
    62
    63
    64
    65
    66
    67
    68
    69
    6A
    Remark
    Fixed data-1
    (Initialized data)
    Fixed data-2
    Fixed data-1
    Fixed data-2
    Fixed data-1
    Fixed data-2
    Fixed data-1
    (Initialized data)
    Fixed data-2
    Fixed data-1
    (Initialized data)
    Address
    6B
    6C
    6D
    6E
    6F
    70
    71
    72
    73
    74
    75
    76
    77
    78
    79
    7A
    7B
    7C
    7D
    7E
    7F
    80
    81
    82
    83
    84
    85
    86
    87
    88
    89
    8A
    8B
    8C
    8D
    8E
    8F
    90
    91
    92
    93
    94
    95
    96
    97
    98
    99
    9A
    9B
    9C
    9D
    9E
    9F
    A0
    A1
    A2
    Remark
    Fixed data-1
    (Initialized data)
    Fixed data-2
    Fixed data-1
    Fixed data-2
    (Modified data, copy the data built in the same
    model.)
    Fixed data-1
    (Initialized data) 
    						
    							5-40
    Address
    A3
    A4
    A5
    A6
    A7
    A8
    A9
    AA
    AB
    AC
    AD
    AE
    AF
    B0
    B1
    B2
    B3
    B4
    B5
    B6
    B7
    B8
    B9
    BA
    BB
    BC
    BD
    BE
    BF
    C0
    C1
    C2
    C3
    C4
    C5
    C6
    C7
    C8
    C9
    CA
    CB
    CC
    CD
    CE
    CF
    D0
    D1
    D2
    D3
    D4
    D5
    D6
    D7
    D8
    D9
    DA
    Remark
    Fixed data-1
    (Initialized data)
    Address
    DB
    DC
    DD
    DE
    DF
    E0 to FF
    Remark
    Fixed data-1
    (Initialized data)
    Table. 5-3-4 
    						
    							5-41 3-3. SYSTEM CONTROL SYSTEM ADJUSTMENT
    1. Battery End Adjustment (VI-151 board)
    Set the battery end voltage.
    If the voltage is incorrect, the life of the battery will shorten. The
    image at the battery end will also lose synchronization.
    Mode Camera recordings
    Subject Arbitrary
    Measurement Point Display data of page: 2, address: 5D
    Measuring Instrument Adjustment remote commander
    Adjustment Page D
    Adjustment Address 30 to 34
    Switch setting:
    1) AUTO FOCUS ................................................................. OFF
    2) LCD display ................................................................. Closed
    Connection:
    1) Connect the regulated power supply and the digital voltmeter
    to the battery terminal as shown in Fig. 5-3-3.
    Adjusting method:
    1) Adjust the output voltage of the regulated power supply so that
    the digital voltmeter reading is 6.1 ± 0.1 V dc.
    2) Turn off the power supply.
    3) Turn on the HOLD switch of the adjustment remote
    commander.
    4) Turn on the power supply.
    5) Load a cassette, and set the recording mode.
    6) Select page: 0, address: 01, and set data: 01.
    7) Decrease the output voltage of the regulated power supply so
    that the digital voltmeter reading is 5.30 ± 0.01 V dc.
    8) Select page: 2, address: 5D, read the data, and this data is named
    Dref.
    9) Set the read-out data (Dref) to page: D. address: 30 and press
    the PAUSE button.
    10) Convert Dref to decimal notation, and obtain Dref. (Refer to
    Table 5-4-1 ÒHexadecimal-decimal Conversion TableÓ of Ò5-
    4. Service ModeÓ.)
    11) Calculate D
    31, D32, D33, D34 and D49 using following equations
    (decimal calculation), convert it to a hexadecimal number, and
    input each adjustment address.
    Address: 31  D
    31 = Dref + 7
    Address: 32  D
    32 = Dref + 25
    Address: 33  D
    33 = Dref + 29
    Address: 34  D
    34 = Dref + 37Note:After setting each data, be sure to press the PAUSE button of
    the adjustment remote commander.
    12) Select page: 0, address: 01, and set data: 00.
    Regulated power supply
    5.30 
    ± 0.01 VdcBattery terminal
    Digital voltmeter
    Fig. 5-3-3 
    						
    							5-42 3-4. SERVO AND RF SYSTEM ADJUSTMENT
    Before performing the servo and RF system adjustments, check that
    the specified value of Ò27 MHz Master Oscillator AdjustmentÓ of
    ÒCAMERA SYSTEM ADJUSTMENTÓ is satisfied.
    Adjusting Procedure:
    1. Cap FG duty adjustment
    2. T-reel FG duty adjustment
    3. PLL f
    0 & LPF f0 adjustment
    4. Switching position adjustment
    5. AGC center level adjustment
    6. APC & AEQ adjustment
    7. PLL f
    0 & LPF f0 final adjustment
    1. Cap FG Duty Adjustment (VI-151 board)
    Set the Cap FG signal duty cycle to 50% to establish an appropriate
    capstan servo.  If deviated, the uneven rotation of capstan and noise
    can occur.
    Measurement Point Display data of page: 3, address: 03
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address 16
    Specified Value 00
    Adjusting Method:
    1) Close the cassette compartment without inserting a cassette.
    2) Select page: 0, address: 01, and set data: 01.
    3) Select page: 3, address: 01, set data: 1B, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: 3, address: 02, and check that the data changes
    starting from Ò1BÓ to Ò2BÓ to Ò00Ó in this order.
    5) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If the data of page: 3, address: 03 is Ò02Ó, adjustment has errors
    or the mechanism deck is defective.
    6) Select page: 0, address: 01, and set data: 00.
    2. T-reel FG Duty Adjustment (VI-151 board)
    Adjust the take-up reel FG signal duty cycle to an appropriate value
    so that the correct T-reel FG signal is obtained.
    Measurement Point Display data of page: 3, address: 03
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address 17
    Specified Value 00
    Adjusting Method:
    1) Close the cassette compartment without inserting a cassette.
    2) Select page: 0, address: 01, and set data: 01.
    3) Select page: 3, address: 01, set data: 1C, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: 3, address: 02, and check that the data changes
    starting from Ò1CÓ to 2C to Ò00Ó in this order.
    5) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If the data of page: 3, address: 03 is Ò02Ó, adjustment has errors
    or the mechanism deck is defective.
    6) Select page: 0, address: 01, and set data: 00.
    3. PLL f0 & LPF f0 Adjustment (VI-151 board)
    Mode VTR stop
    Measurement Point Display data of page: 3, address: 03
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address 1F, 20, 22, 47
    Specified Value 00
    Adjusting Method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 01, set data: 30, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 02, and check that the data is changed
    to Ò00Ó.
    4) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If the data of page: 3, address: 03 is other than Ò00Ó, there are
    errors.  (For the error contents, see the following table.  For the
    bit values, refer to Ò5-4. SERVICE MODEÓ, Ò4-3. 3. Bit value
    discriminationÓ.
    5) Select page: 0, address: 01, and set data: 00.
    Bit value of page: 3,
    address: 03
    bit 4 = 1
    bit 5 = 1
    bit 6 = 1
    bit 3 = 1
    Error contents
    PLL f0, even channel is defective
    PLL f0, odd channel is defective
    LPF f0 is defective
    PLL f0 final adjustment is defective 
    						
    							5-43
    4. Switching Position Adjustment (VI-151 board)
    Mode VTR playback
    Signal SW/OL reference tape (XH2-3)
    Measurement Point Display data of page: 3, address: 03
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address 10, 11, 12, 13
    Specified Value 00
    Adjusting Method:
    1) Insert the SW/OL reference tape and enter the VTR STOP
    mode.
    2) Select page: 0, address: 01, and set data: 01.
    3) Select page: 3, address: 21, and check that the data is Ò02Ó.
    Note:If the data of page: 3, address: 21 is Ò72Ó, the tape top is being
    played.  After playing the tape for 1 to 2 seconds, perform step
    4 and higher.
    4) Select page: 3, address: 01, set data: 0D, and press the PAUSE
    button of the adjustment remote commander.
    5) Select page: 3, address: 02, and check the data is changed to
    00.
    6) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If bit 0 of page: 3, address: 03 data is Ò1Ó, the even channel is
    defective.  If bit 1 is Ò1Ó, the odd channel is defective.  Contents
    of the defect is written into page: C, addresses: 10 and 12.  See
    the following table.  (For the bit value, refer to Ò5-4. SERVICE
    MODEÓ, Ò4-3. 3. Bit value discriminationÓ.)
    7) Select page: 0, address: 01, and set data: 00.
    When the even channel is defective
    When the odd channel is defective5. AGC Center Level Adjustment (VI-151 board)
    Mode Camera record and playback
    Subject Arbitrary
    Measurement Point Pin @¼ of CN2904 (RF MON) (Note 1)
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 1E
    Specified Value The display data of page: 3, address:
    03 is Ò00Ó
    Note 1:Connect a 75 W resistor between Pin @¼ and Pin !» (GND) of
    CN2904.
    75 W resistor (Parts code: 1-247-804-11)
    Adjusting Method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 2, address: 30, and set data: 40.
    3) Record the camera signal for a minute.
    4) Playback the recorded segment.
    5) Select page: 3, address: 33, and set data: 08.
    6) Confirm that the playback RF signal is stable.
    7) Select page: 3, address: 01, set data: 23, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 3, address: 02, and check that the data is  Ò00Ó.
    9) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If data of page: 3, address: 03 is other than Ò00Ó, adjustment
    has errors.  (Take an appropriate remedial measures according
    to the errors referring to the following table.)
    10) Select page: 3, address: 33, and set data: 00.
    11) Select page: 2, address: 30, and set data: 00.
    12) Select page: 0, address: 01, and set data: 00.
    Note 2:If this data is displayed twice successively, the machine is defective.
    Data of page: C,
    address: 10
    EE
    E8
    E7
    Contents of defect
    Writing into EEPROM (IC2404) is defective
    Adjustment data is out of range
    No data is returned from IC1900 (TRX)
    Data of page: C,
    address: 12
    EE
    E8
    E7
    Contents of defect
    Writing into EEPROM (IC2404) is defective
    Adjustment data is out of range
    No data is returned from IC1900 (TRX)
    Data of page: 3,
    address: 03
    20
    30
    40
    50
    Remedial measures
    Perform re-adjustment. (Note 2)
    The machine is defective
    Perform re-adjustment. (Note 2)
    The machine is defective 
    						
    							5-44
    6. APC & AEQ Adjustment (VI-151 board)
    Mode Camera record and playback
    Subject Arbitrary
    Measurement Point Pin @¼ of CN2904 (RF MON) (Note 1)
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 18, 19, 1B, 1C, 21, 73
    Specified Value The display data of page: 3, address:
    03 is Ò00Ó
    Note 1:Connect a 75 W resistor between Pin @¼ and Pin !» (GND) of
    CN2904.
    75 W resistor (Parts code: 1-247-804-11)
    Note 2:The Ò5. AGC Center Level AdjustmentÓ must have already been
    completed before starting this adjustment.
    Adjusting Method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 2, address: 30, and set data: 40.
    3) Record the camera signal for a minute.
    4) Playback the recorded segment.
    5) Select page: 3, address: 33, and set data: 08.
    6) Check that the playback RF signal is stable.
    7) Select page: 3, address: 01, set data: 07, and press the PAUSE
    button of the adjustment remote commander.
    8) Check that the data of page: 3, address: 02 changes from Ò07Ó
    to Ò00Ó in about 15 seconds after pressing the PAUSE button.
    9) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If data of page: 3, address: 03 is other than Ò00Ó, adjustment
    has errors.  (Take an appropriate remedial measures according
    to the errors referring to the following table.)
    10) Select page: 3, address: 33, and set data: 00.
    11) Select page: 2, address: 30, and set data: 00.
    12) Select page: 0, address: 01, and set data: 00.
    Note 3:If this data is displayed twice successively, the machine is defective.
    7. PLL f0 & LPF f0 Final Adjustment (VI-151 board)
    Mode VTR playback
    Signal Arbitrary
    Measurement Point Display data of page: 3, address: 03
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address 1F, 20, 22, 47
    Specified Value 00
    Adjusting Method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 01, set data: 30, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 02, and check that the data changes to
    00.
    4) Select page: 3, address: 03, and check that the data is Ò00Ó.
    Note:If the data of page: 3, address: 03 is other than 00, there are
    errors.  (For the error contents, see the following table.  For the
    bit values, refer to Ò5-4. SERVICE MODEÓ, Ò4-3. 3. Bit value
    discriminationÓ.
    5) Select page: 0, address: 01, and set data: 00.
    Data of page: 3,
    address: 03
    20
    30
    50
    60
    80
    Remedial measures
    Perform re-adjustment. (Note 3)
    The machine is defective
    Perform re-adjustment. (Note 3)
    The machine is defective
    The machine is defective
    Bit value of page: 3,
    address: 03
    bit 4 = 1
    bit 5 = 1
    bit 6 = 1
    bit 3 = 1
    Error contents
    PLL f0, even channel is defective
    PLL f0, odd channel is defective
    LPF f0 is defective
    PLL f0 final adjustment is defective
    CN29041 19
    2
    20
    25 363748 1 12
    13
    24
    IC1403
    VI-151 board (SIDE A) 
    						
    							5-45
    CH1
    CH2A
    H
    H CH1 B
    3-5.  VIDEO SYSTEM ADJUSTMENTS
    Before perform the video system adjustments, check that the
    specified value of Ò27 MHz Origin Oscillation AdjustmentÓ of
    ÒCAMERA SYSTEM ADJUSTMENTÓ is satisfied.
    3-5-1. Base Band Block Adjustments
    1. Chroma BPF fo Adjustment (VI-151 Board)
    Set the center frequency of IC1402 chroma band-pass filter.
    Mode VTR stop
    Signal No signal
    Measurement Point CH1: Chroma signal terminal of
    S VIDEO jack (75 W terminated)
    CH2: Y signal terminal of S VIDEO
    jack (75 W terminated)
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 2B
    Specified Value A = 100mVp-p or less
    B = 200mVp-p or more
    Switch setting:
    DISPLAY (Menu display) ............................ V-OUT/LCD
    DISPLAY (CK-80 board) ............................................ ON
    Adjusting method:
    1) Check that the burst signal (B) is output to the chroma signal
    terminal of S VIDEO jack.
    2) Select page: 0, address: 01, and set data: 01.
    3) Select page: 3, address: 0C, set data: 04, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: C, address: 2B, and change the data for minimum
    amplitude of the burst signal level (A).
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    6) Check that the burst signal level (B) is satisfied the specified
    value.
    7) Select page: 0, address: 01, and set data: 00.
    When the data of page: 3, address: 0C, is 04:
    Fig. 5-3-4
    When the data of page: 3, address: 0C, is 00.
    Fig. 5-3-5
    2. S VIDEO OUT Y Level Adjustment (VI-151 Board)
    Mode Camera
    Subject Arbitrary
    Measurement Point Y signal terminal of S VIDEO jack
    (75 W terminated)
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 25
    Specified Value A = 1000 ± 14mV
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 2, address: 35. After note down the data of this
    address, set data: 01 to the address.
    3) Select page: 3, address: 0C, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: C, address: 25, change the data and set the Y signal
    level (A) to the specified value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 2, address: 35. and set the data that is noted down
    at step 2).
    8) Select page: 0, address: 01, and set data: 00.
    HA
    Fig. 5-3-6 
    						
    							5-46
    3. S VIDEO OUT Chroma Level Adjustment
        (VI-151 Board)
     Mode Camera
    Subject Arbitrary
    Measurement Point Chroma signal terminal of S VIDEO
    jack (75 W terminated)
    External trigger: Y signal terminal of
    S VIDEO jack
    Measuring Instrument Oscilloscope
    Adjustment Page C
    Adjustment Address 26, 27
    Specified Value Cr level: A = 714 ± 14mV(NTSC)
    A = 700 ± 14mV(PAL)
    Cb level: B = 714 ± 14mV(NTSC)
    B = 700 ± 14mV(PAL)
    Burst level: C = 286 ± 6mV(NTSC)
    C = 300 ± 6mV(PAL)
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 2, address: 35. After note down the data of this
    address, set data: 01 to the address.
    3) Select page: 3, address: 0C, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: C, address: 26, change the data and set the Cr
    signal level (A) to the specified value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: C, address: 27, change the data and set the Cb
    signal level (B) to the specified value.
    7) Press the PAUSE button of the adjustment remote commander.
    8) Check that the burst signal level (C) is satisfied the specified
    value.
    9) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    10) Select page: 2, address: 35. and set the data that is noted down
    at step 2).
    11) Select page: 0, address: 01, and set data: 00.4. AV OUT Y, Chroma Level Check (VI-151 Board)
    Mode Camera
    Subject Arbitrary
    Measurement Point Video terminal of AUDIO/VIDEO
    jack (75 W terminated)
    Measuring Instrument Oscilloscope
    Specified Value Sync level: A = 286 ± 18mV(NTSC)
    A = 300 ± 18mV(PAL)
    Burst level: B = 286 ± 18mV(NTSC)
    B = 300 ± 18mV(PAL)
    Adjusting method:
    1) Select page: 2, address: 35. After note down the data of this
    address, set data: 01 to the address.
    2) Select page: 3, address: 0C, set data: 02, and press the PAUSE
    button of the adjusting remote commander.
    3) Check that the sync signal level (A) satisfies the specified value.
    4) Check that the burst signal level (B) satisfies the specified value.
    5) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    6) Select page: 2, address: 35. and set the data that is noted down
    at step 1).
    2H
    C
    A
    0.28 µsec (NTSC)
    0.23 µsec (PAL)
    B
    0.28 µsec (NTSC) 
    0.23 µsec (PAL)
    2HB
    A
    Fig. 5-3-7Fig. 5-3-8 
    						
    							5-47
    5. PLL Adjustment (VC-208 Board)
        (Except DCR-TRV890E)
    Set the VCO center level of the video input circuit (IC1200).
    Mode VTR stop
    Signal Color bar (Video terminal of AUDIO/
    VIDEO jack input)
    Measurement Point Display data of page: 3, address: 04
    Measuring Instrument Adjustment remote commander
    Adjustment Page C
    Adjustment Address AA
    Specified Value 08 or 09
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 80, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: C, address: AA, and set data: 00, and press the
    PAUSE button.
    4) Select page: 3, address: 04, and check. If the data is Ò08Ó or
    Ò09Ó, proceed to step 7).
    5) Select page: C, address: AA, add Ò10Ó(hexadecimal) to the data
    and press the PAUSE button.
    6) Select page: 3, address: 04, and check the data is Ò08Ó or Ò09Ó.
    If not repeat steps 5) to 6).
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00. 
    						
    All Sony manuals Comments (0)