Sony Dcrtrv890e Manual
Have a look at the manual Sony Dcrtrv890e Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
5-38 Table. 5-3-3 Address 89 8A 8B 8C 8D 8E 8F 90 to FF Initial value NTSC 58 62 PA L 58 62 Remark Fixed data-1 Bright adj.(LCD) Fixed data-2 Contrast adj.(LCD) Fixed data-2 Fixed data-1 7. Initializing the B Page DataNote:If the B page data is initialized, the following adjustments must be performed again. 1) Modification of B page data Adjusting page B Adjusting Address 00 to DF Initializing Method: 1) Set the power switch to the MEMORY position. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 2, address: 8F, set data: 03, and press the PAUSE button. 4) Select page: 2, address: 8F, set data: 00, and press the PAUSE button. 5) Select page: 5, address: 01, set data: F3, and press the PAUSE button. 6) Select page: 5, address: 00, set data: 01, and press the PAUSE button. 7) Select page: 5, address: 02, and check that the data is Ò00Ó. 8) Perform ÒModification of B Page DataÓ. 8. Modification of B Page Data If the B Page data has been initialized, change the data of the ÒFixed data-2Ó address shown in the following tables by manual input. Processing before Modification of B Page data 1) Select page: 2, address: 8F, set data: 03, and press the PAUSE button. 2) Select page: 2, address: 8F, set data: 00, and press the PAUSE button . Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note:If copy the data built in the different model, the camcorder may not operate. 3) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. Processing after Completing Modification of B Page data 1) Select page: 2, address: 00, and set data: 29. 2) Select page: 2, address: 01, and set data: 29, and press the PAUSE button of the adjustment remote commander.9. B Page Table Note 1:Fixed data-1 : Initialized data. ( Refer to Ò7. Initializing the B Page DataÓ.) Fixed data-2 : Modified data. (Refer to Ò8. Modification of B PAGE DataÓ). Address 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 Remark Fixed data-1 (Initialized data)
![](/img/blank.gif)
5-39 Address 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Address 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 Fixed data-2 (Modified data, copy the data built in the same model.) Fixed data-1 (Initialized data)
![](/img/blank.gif)
5-40 Address A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA Remark Fixed data-1 (Initialized data) Address DB DC DD DE DF E0 to FF Remark Fixed data-1 (Initialized data) Table. 5-3-4
![](/img/blank.gif)
5-41 3-3. SYSTEM CONTROL SYSTEM ADJUSTMENT 1. Battery End Adjustment (VI-151 board) Set the battery end voltage. If the voltage is incorrect, the life of the battery will shorten. The image at the battery end will also lose synchronization. Mode Camera recordings Subject Arbitrary Measurement Point Display data of page: 2, address: 5D Measuring Instrument Adjustment remote commander Adjustment Page D Adjustment Address 30 to 34 Switch setting: 1) AUTO FOCUS ................................................................. OFF 2) LCD display ................................................................. Closed Connection: 1) Connect the regulated power supply and the digital voltmeter to the battery terminal as shown in Fig. 5-3-3. Adjusting method: 1) Adjust the output voltage of the regulated power supply so that the digital voltmeter reading is 6.1 ± 0.1 V dc. 2) Turn off the power supply. 3) Turn on the HOLD switch of the adjustment remote commander. 4) Turn on the power supply. 5) Load a cassette, and set the recording mode. 6) Select page: 0, address: 01, and set data: 01. 7) Decrease the output voltage of the regulated power supply so that the digital voltmeter reading is 5.30 ± 0.01 V dc. 8) Select page: 2, address: 5D, read the data, and this data is named Dref. 9) Set the read-out data (Dref) to page: D. address: 30 and press the PAUSE button. 10) Convert Dref to decimal notation, and obtain Dref. (Refer to Table 5-4-1 ÒHexadecimal-decimal Conversion TableÓ of Ò5- 4. Service ModeÓ.) 11) Calculate D 31, D32, D33, D34 and D49 using following equations (decimal calculation), convert it to a hexadecimal number, and input each adjustment address. Address: 31 D 31 = Dref + 7 Address: 32 D 32 = Dref + 25 Address: 33 D 33 = Dref + 29 Address: 34 D 34 = Dref + 37Note:After setting each data, be sure to press the PAUSE button of the adjustment remote commander. 12) Select page: 0, address: 01, and set data: 00. Regulated power supply 5.30 ± 0.01 VdcBattery terminal Digital voltmeter Fig. 5-3-3
![](/img/blank.gif)
5-42 3-4. SERVO AND RF SYSTEM ADJUSTMENT Before performing the servo and RF system adjustments, check that the specified value of Ò27 MHz Master Oscillator AdjustmentÓ of ÒCAMERA SYSTEM ADJUSTMENTÓ is satisfied. Adjusting Procedure: 1. Cap FG duty adjustment 2. T-reel FG duty adjustment 3. PLL f 0 & LPF f0 adjustment 4. Switching position adjustment 5. AGC center level adjustment 6. APC & AEQ adjustment 7. PLL f 0 & LPF f0 final adjustment 1. Cap FG Duty Adjustment (VI-151 board) Set the Cap FG signal duty cycle to 50% to establish an appropriate capstan servo. If deviated, the uneven rotation of capstan and noise can occur. Measurement Point Display data of page: 3, address: 03 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address 16 Specified Value 00 Adjusting Method: 1) Close the cassette compartment without inserting a cassette. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 3, address: 01, set data: 1B, and press the PAUSE button of the adjustment remote commander. 4) Select page: 3, address: 02, and check that the data changes starting from Ò1BÓ to Ò2BÓ to Ò00Ó in this order. 5) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If the data of page: 3, address: 03 is Ò02Ó, adjustment has errors or the mechanism deck is defective. 6) Select page: 0, address: 01, and set data: 00. 2. T-reel FG Duty Adjustment (VI-151 board) Adjust the take-up reel FG signal duty cycle to an appropriate value so that the correct T-reel FG signal is obtained. Measurement Point Display data of page: 3, address: 03 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address 17 Specified Value 00 Adjusting Method: 1) Close the cassette compartment without inserting a cassette. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 3, address: 01, set data: 1C, and press the PAUSE button of the adjustment remote commander. 4) Select page: 3, address: 02, and check that the data changes starting from Ò1CÓ to 2C to Ò00Ó in this order. 5) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If the data of page: 3, address: 03 is Ò02Ó, adjustment has errors or the mechanism deck is defective. 6) Select page: 0, address: 01, and set data: 00. 3. PLL f0 & LPF f0 Adjustment (VI-151 board) Mode VTR stop Measurement Point Display data of page: 3, address: 03 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address 1F, 20, 22, 47 Specified Value 00 Adjusting Method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 01, set data: 30, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 02, and check that the data is changed to Ò00Ó. 4) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If the data of page: 3, address: 03 is other than Ò00Ó, there are errors. (For the error contents, see the following table. For the bit values, refer to Ò5-4. SERVICE MODEÓ, Ò4-3. 3. Bit value discriminationÓ. 5) Select page: 0, address: 01, and set data: 00. Bit value of page: 3, address: 03 bit 4 = 1 bit 5 = 1 bit 6 = 1 bit 3 = 1 Error contents PLL f0, even channel is defective PLL f0, odd channel is defective LPF f0 is defective PLL f0 final adjustment is defective
![](/img/blank.gif)
5-43 4. Switching Position Adjustment (VI-151 board) Mode VTR playback Signal SW/OL reference tape (XH2-3) Measurement Point Display data of page: 3, address: 03 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address 10, 11, 12, 13 Specified Value 00 Adjusting Method: 1) Insert the SW/OL reference tape and enter the VTR STOP mode. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 3, address: 21, and check that the data is Ò02Ó. Note:If the data of page: 3, address: 21 is Ò72Ó, the tape top is being played. After playing the tape for 1 to 2 seconds, perform step 4 and higher. 4) Select page: 3, address: 01, set data: 0D, and press the PAUSE button of the adjustment remote commander. 5) Select page: 3, address: 02, and check the data is changed to 00. 6) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If bit 0 of page: 3, address: 03 data is Ò1Ó, the even channel is defective. If bit 1 is Ò1Ó, the odd channel is defective. Contents of the defect is written into page: C, addresses: 10 and 12. See the following table. (For the bit value, refer to Ò5-4. SERVICE MODEÓ, Ò4-3. 3. Bit value discriminationÓ.) 7) Select page: 0, address: 01, and set data: 00. When the even channel is defective When the odd channel is defective5. AGC Center Level Adjustment (VI-151 board) Mode Camera record and playback Subject Arbitrary Measurement Point Pin @¼ of CN2904 (RF MON) (Note 1) Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 1E Specified Value The display data of page: 3, address: 03 is Ò00Ó Note 1:Connect a 75 W resistor between Pin @¼ and Pin !» (GND) of CN2904. 75 W resistor (Parts code: 1-247-804-11) Adjusting Method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 2, address: 30, and set data: 40. 3) Record the camera signal for a minute. 4) Playback the recorded segment. 5) Select page: 3, address: 33, and set data: 08. 6) Confirm that the playback RF signal is stable. 7) Select page: 3, address: 01, set data: 23, and press the PAUSE button of the adjustment remote commander. 8) Select page: 3, address: 02, and check that the data is Ò00Ó. 9) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If data of page: 3, address: 03 is other than Ò00Ó, adjustment has errors. (Take an appropriate remedial measures according to the errors referring to the following table.) 10) Select page: 3, address: 33, and set data: 00. 11) Select page: 2, address: 30, and set data: 00. 12) Select page: 0, address: 01, and set data: 00. Note 2:If this data is displayed twice successively, the machine is defective. Data of page: C, address: 10 EE E8 E7 Contents of defect Writing into EEPROM (IC2404) is defective Adjustment data is out of range No data is returned from IC1900 (TRX) Data of page: C, address: 12 EE E8 E7 Contents of defect Writing into EEPROM (IC2404) is defective Adjustment data is out of range No data is returned from IC1900 (TRX) Data of page: 3, address: 03 20 30 40 50 Remedial measures Perform re-adjustment. (Note 2) The machine is defective Perform re-adjustment. (Note 2) The machine is defective
![](/img/blank.gif)
5-44 6. APC & AEQ Adjustment (VI-151 board) Mode Camera record and playback Subject Arbitrary Measurement Point Pin @¼ of CN2904 (RF MON) (Note 1) Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 18, 19, 1B, 1C, 21, 73 Specified Value The display data of page: 3, address: 03 is Ò00Ó Note 1:Connect a 75 W resistor between Pin @¼ and Pin !» (GND) of CN2904. 75 W resistor (Parts code: 1-247-804-11) Note 2:The Ò5. AGC Center Level AdjustmentÓ must have already been completed before starting this adjustment. Adjusting Method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 2, address: 30, and set data: 40. 3) Record the camera signal for a minute. 4) Playback the recorded segment. 5) Select page: 3, address: 33, and set data: 08. 6) Check that the playback RF signal is stable. 7) Select page: 3, address: 01, set data: 07, and press the PAUSE button of the adjustment remote commander. 8) Check that the data of page: 3, address: 02 changes from Ò07Ó to Ò00Ó in about 15 seconds after pressing the PAUSE button. 9) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If data of page: 3, address: 03 is other than Ò00Ó, adjustment has errors. (Take an appropriate remedial measures according to the errors referring to the following table.) 10) Select page: 3, address: 33, and set data: 00. 11) Select page: 2, address: 30, and set data: 00. 12) Select page: 0, address: 01, and set data: 00. Note 3:If this data is displayed twice successively, the machine is defective. 7. PLL f0 & LPF f0 Final Adjustment (VI-151 board) Mode VTR playback Signal Arbitrary Measurement Point Display data of page: 3, address: 03 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address 1F, 20, 22, 47 Specified Value 00 Adjusting Method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 01, set data: 30, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 02, and check that the data changes to 00. 4) Select page: 3, address: 03, and check that the data is Ò00Ó. Note:If the data of page: 3, address: 03 is other than 00, there are errors. (For the error contents, see the following table. For the bit values, refer to Ò5-4. SERVICE MODEÓ, Ò4-3. 3. Bit value discriminationÓ. 5) Select page: 0, address: 01, and set data: 00. Data of page: 3, address: 03 20 30 50 60 80 Remedial measures Perform re-adjustment. (Note 3) The machine is defective Perform re-adjustment. (Note 3) The machine is defective The machine is defective Bit value of page: 3, address: 03 bit 4 = 1 bit 5 = 1 bit 6 = 1 bit 3 = 1 Error contents PLL f0, even channel is defective PLL f0, odd channel is defective LPF f0 is defective PLL f0 final adjustment is defective CN29041 19 2 20 25 363748 1 12 13 24 IC1403 VI-151 board (SIDE A)
![](/img/blank.gif)
5-45 CH1 CH2A H H CH1 B 3-5. VIDEO SYSTEM ADJUSTMENTS Before perform the video system adjustments, check that the specified value of Ò27 MHz Origin Oscillation AdjustmentÓ of ÒCAMERA SYSTEM ADJUSTMENTÓ is satisfied. 3-5-1. Base Band Block Adjustments 1. Chroma BPF fo Adjustment (VI-151 Board) Set the center frequency of IC1402 chroma band-pass filter. Mode VTR stop Signal No signal Measurement Point CH1: Chroma signal terminal of S VIDEO jack (75 W terminated) CH2: Y signal terminal of S VIDEO jack (75 W terminated) Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 2B Specified Value A = 100mVp-p or less B = 200mVp-p or more Switch setting: DISPLAY (Menu display) ............................ V-OUT/LCD DISPLAY (CK-80 board) ............................................ ON Adjusting method: 1) Check that the burst signal (B) is output to the chroma signal terminal of S VIDEO jack. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 3, address: 0C, set data: 04, and press the PAUSE button of the adjustment remote commander. 4) Select page: C, address: 2B, and change the data for minimum amplitude of the burst signal level (A). 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 6) Check that the burst signal level (B) is satisfied the specified value. 7) Select page: 0, address: 01, and set data: 00. When the data of page: 3, address: 0C, is 04: Fig. 5-3-4 When the data of page: 3, address: 0C, is 00. Fig. 5-3-5 2. S VIDEO OUT Y Level Adjustment (VI-151 Board) Mode Camera Subject Arbitrary Measurement Point Y signal terminal of S VIDEO jack (75 W terminated) Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 25 Specified Value A = 1000 ± 14mV Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 2, address: 35. After note down the data of this address, set data: 01 to the address. 3) Select page: 3, address: 0C, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: C, address: 25, change the data and set the Y signal level (A) to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 2, address: 35. and set the data that is noted down at step 2). 8) Select page: 0, address: 01, and set data: 00. HA Fig. 5-3-6
![](/img/blank.gif)
5-46 3. S VIDEO OUT Chroma Level Adjustment (VI-151 Board) Mode Camera Subject Arbitrary Measurement Point Chroma signal terminal of S VIDEO jack (75 W terminated) External trigger: Y signal terminal of S VIDEO jack Measuring Instrument Oscilloscope Adjustment Page C Adjustment Address 26, 27 Specified Value Cr level: A = 714 ± 14mV(NTSC) A = 700 ± 14mV(PAL) Cb level: B = 714 ± 14mV(NTSC) B = 700 ± 14mV(PAL) Burst level: C = 286 ± 6mV(NTSC) C = 300 ± 6mV(PAL) Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 2, address: 35. After note down the data of this address, set data: 01 to the address. 3) Select page: 3, address: 0C, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: C, address: 26, change the data and set the Cr signal level (A) to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: C, address: 27, change the data and set the Cb signal level (B) to the specified value. 7) Press the PAUSE button of the adjustment remote commander. 8) Check that the burst signal level (C) is satisfied the specified value. 9) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 10) Select page: 2, address: 35. and set the data that is noted down at step 2). 11) Select page: 0, address: 01, and set data: 00.4. AV OUT Y, Chroma Level Check (VI-151 Board) Mode Camera Subject Arbitrary Measurement Point Video terminal of AUDIO/VIDEO jack (75 W terminated) Measuring Instrument Oscilloscope Specified Value Sync level: A = 286 ± 18mV(NTSC) A = 300 ± 18mV(PAL) Burst level: B = 286 ± 18mV(NTSC) B = 300 ± 18mV(PAL) Adjusting method: 1) Select page: 2, address: 35. After note down the data of this address, set data: 01 to the address. 2) Select page: 3, address: 0C, set data: 02, and press the PAUSE button of the adjusting remote commander. 3) Check that the sync signal level (A) satisfies the specified value. 4) Check that the burst signal level (B) satisfies the specified value. 5) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 6) Select page: 2, address: 35. and set the data that is noted down at step 1). 2H C A 0.28 µsec (NTSC) 0.23 µsec (PAL) B 0.28 µsec (NTSC) 0.23 µsec (PAL) 2HB A Fig. 5-3-7Fig. 5-3-8
![](/img/blank.gif)
5-47 5. PLL Adjustment (VC-208 Board) (Except DCR-TRV890E) Set the VCO center level of the video input circuit (IC1200). Mode VTR stop Signal Color bar (Video terminal of AUDIO/ VIDEO jack input) Measurement Point Display data of page: 3, address: 04 Measuring Instrument Adjustment remote commander Adjustment Page C Adjustment Address AA Specified Value 08 or 09 Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 80, and press the PAUSE button of the adjustment remote commander. 3) Select page: C, address: AA, and set data: 00, and press the PAUSE button. 4) Select page: 3, address: 04, and check. If the data is Ò08Ó or Ò09Ó, proceed to step 7). 5) Select page: C, address: AA, add Ò10Ó(hexadecimal) to the data and press the PAUSE button. 6) Select page: 3, address: 04, and check the data is Ò08Ó or Ò09Ó. If not repeat steps 5) to 6). 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00.