5-18 15. White Balance Check Subject Clear chart (Color bar standard picture frame) Filter Filter C14 for color temperature correction ND filter 1.0 and 0.3 Measurement Point Video output terminal Measuring Instrument Vectorscope Specified Value Fig. 5-1-11. A to C Checking method: 1) Check that the lens is not covered with either filter. 2) Select page: 6, address: 01, set data: 0F, and press the PAUSE button of the adjustment remote commander. 3) Check that the center of the white luminance point is within the circle shown Fig. 5-1-11. A. 4) Select page: 6, address: 01, set data: 23, and press the PAUSE button of the adjustment remote commander. 5) Place the C14 filter on the lens. 6) Check that the center of the white luminance point settles in the circle shown Fig. 5-1-11.B. 7) Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3) on the lens. 8) Check that the white luminance point stopped moving, and then remove the ND filter 1.3. 9) Check that the center of the white luminance point settles within the circle shown Fig. 5-1-11.C. Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. R-Y 2mm B-Y 2mm R-Y B- Y 1.0mm1.0mm 3mm 3mm R-Y B- Y 3mm 3mm 2.0mm 1.0mm Fig. 5-1-11 (A) Fig. 5-1-11 (B) Fig. 5-1-11 (C)
5-19 16. PSD Sensor Gain Adjustment Adjust the gain of the PSD sensor for steady shot operation. 16-1. PSD Sensor Gain Adjustment (1) Subject Pattern A (1.5m from the front of the lens) Measurement Point Video output terminal Measuring Instrument Oscilloscope (V period) Adjustment Page E Adjustment Address 48 Fig.5-1-12. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: E, address: 48, set data: 80, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 01, set data: 8F, and press the PAUSE button of the adjustment remote commander. 4) Expose pattern A with the zoom TELE end. 5) Adjust the focus. 6) Measure the vertical position SV1 (msec) of the falling edge of the waveform. (Oscilloscope is V period) 7) Select page: 6, address: 01, set data: 91, and press the PAUSE button. 8) Measure the vertical position SV2 (msec) of the falling edge of the waveform. (Oscilloscope is V period) 9) Obtain D48 using the following equation (decimal calculation). NTSC model D 48 = 128 ´ (2.88/(SV2ÐSV1)) PAL model D 48 = 128 ´ (3.40/(SV2ÐSV1)) 10) Convert D 48 to hexadecimal notation, and obtain D48. (Round off to one decimal place) (Refer to Table 5-4-1. ÒHexadecimal notation-Decimal notation conversion tableÓ of Ò5-4. Service ModeÓ. ) 11) Select page: E, address: 48, set data: D 48, and press the PAUSE button of the adjustment remote commander. Processing after Completing Adjustments 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 0, address: 01, and set data: 00. 3) Check that the steady shot operation is performed normally. Fig. 5-1-13. White White Pattern A A4 size (297mm ´ 210mm) Black V SV1 (msec)SV2 (msec)SV2–SV1 Falling edge of waveform when data is “91” Falling edge of waveform when data is “8F”
5-20 16-2. PSD Sensor Gain Adjustment (2) Subject Pattern B (1.5m from the front of the lens) Measurement Point Video output terminal Measuring Instrument Oscilloscope (H period) Adjustment Page E Adjustment Address 49 Fig.5-1-14. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: E, address: 49, set data: 80, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 01, set data: 8F, and press the PAUSE button of the adjustment remote commander. 4) Expose pattern B with the zoom TELE end. 5) Adjust the focus. 6) Measure the horizontal position SH1 (msec) of the falling edge of the waveform. (Oscilloscope is H period) 7) Select page: 6, address: 01, set data: 91, and press the PAUSE button. 8) Measure the horizontal position SH2 (msec) of the falling edge of the waveform. (Oscilloscope is H period) 9) Obtain D49 using the following equation (decimal calculation). D 49 = 128 ´ (7.4/(SH2ÐSH1)) 10) Convert D 49 to hexadecimal notation, and obtain D49. (Round off to one decimal place) (Refer to Table 5-4-1. ÒHexadecimal notation-Decimal notation conversion tableÓ of Ò5-4. Service ModeÓ. ) 11) Select page: E, address: 49, set data: D 49, and press the PAUSE button of the adjustment remote commander. Processing after Completing Adjustments 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 0, address: 01, and set data: 00. 3) Check that the steady shot operation is performed normally. Fig. 5-1-15. White WhiteBlack Pattern B A4 size (297mm ´ 210mm) H SH1 (msec)SH2 (msec)SH2–SH1 Falling edge of waveform when data is “91” Falling edge of waveform when data is “8F”
5-21 17. Angular Velocity Sensor Sensitivity Adjustment ¥ This adjustment is performed only when replacing the angular velocity sensor. Although this adjustment need not be performed when the circuit is damaged, etc., check the operations. ¥ Note down the sensitivity displayed on the angular velocity sensor of the repair parts. At this time, note down also to which board it was attached to. Be sure to check because if attached incorrectly, the screen will vibrate up and down or left and right during hand-shake correction operations. Precautions on the Parts Replacement There are two types of repair parts. Type A ENC03JA Type B ENC03JB Replace the broken sensor with a same type sensor. If replace with other type parts, the image will vibrate up and down or left and right during hand-shake correction operations. After replacing, re- adjust according to the adjusting method after replacement. Precautions on Angular Velocity Sensor The sensor incorporates a precision oscillator. Handle it with care as if it dropped, the balance of the oscillator will be disrupted and operations will not be performed properly. Adjustment Page F Adjustment Address 41, 42 Note:The sensor sensitivity of SE450 and SE451 of the SE-75 board is written only on the repair parts. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Read the sensor sensitivity written on SE450 of the SE-75 board, and take this as S 450. 3) Read the sensor sensitivity written on SE451 of the SE-75 board, and take this as S 451. 4) Calculate D 41 and D42 using the following equation (decimal calculation). D 41 = 80 ´ (0.60/S451) D 42 = 80 ´ (0.60/S450) 5) Convert D 41 and D42 into hexadecimal digits, to obtain D41 and D42. (Round off decimal points) 6) Select page: F, address: 41, set data: D 41, and press the PAUSE button of the adjustment remote commander. 7) Select page: F, address: 42, set data: D 42, and press the PAUSE button of the adjustment remote commander. Processing after Completing Adjustments 1) Select page: 0, address: 01, and set data: 00. 2) Check that the steady shot operations have been performed normally.
5-22 H A GND level (0Vdc) Pin No. 1 3 5 7 9 11 13 15 17 19 Signal Name LANC SIG EVF BL Ð EVF VCO PD VG H START PANEL COM TCK TDO SWP GND Pin No. 2 4 6 8 10 12 14 16 18 20 Signal Name EVF BL + EVF VG GND PD VCO XHD/PSIG TMS TDI GND RF IN/LANC JACK IN RF MON 1-4. COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT Note 1:The back light (fluorescent tube) is driven by a high voltage AC power supply. Therefore, do not touch the back light holder to avoid electrical shock. Note 2:When replacing the LCD unit, be careful to prevent damages caused by static electricity. Note 3:Set the VF BRIGHT (Menu display) to the center. [Adjusting connector] Most of the measuring points for adjusting the viewfinder system are concentrated in CN2904 of the VI-151 board. Connect the Measuring Instruments via the CPC-8 jig (J-6082-388- A). The following table shows the Pin No. and signal name of CN2904. Table 5-1-3. 1. VCO Adjustment (VF-121 board) Set the VCO free-run frequency. If deviated, the EVF screen will be blurred. Mode VTR stop Signal Arbitrary Measurement Point Pin 5 of CN2904 (EVF VCO) on VI-151 board Measuring Instrument Oscilloscope (DC range) Adjustment Page D Adjustment Address 75 Specified Value A = 1.7 ± 0.2V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Check the GND level of the oscilloscope. 3) Select page: D, address: 75, change the data and set the VCO output voltage (A) to the specified value. 4) Press the PAUSE button of the adjustment remote commander. 5) Select page: 0, address: 01, and set data: 00. Fig. 5-1-16Fig. 5-1-17 CN2904 1 192 20 Remove the CPC cover
5-23 2. Bright Adjustment (VF-121 board) Set the level of the VIDEO signal for driving the LCD to the specified value. If deviated, the screen image will be blackish or saturated (whitish). Mode Camera Subject Arbitrary Measurement Point Pin 4 of CN2904 (EVF VG) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 7A Specified Value A = 7.25 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 7A, change the data and set the voltage (A) between the reversed waveform pedestal and non-reversed waveform pedestal to the specified value. (The data of address: 7A should be Ò54Ó to ÒD7Ó.) 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00.3. Contrast Adjustment (VF-121 board) Set the level of the VIDEO signal for driving the LCD to the specified value. If deviated, the screen image will be blackish or saturated (whitish). Mode Camera Subject Arbitrary Measurement Point Pin 4 of CN2904 (EVF VG) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 7B Specified Value A = 1.81 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 7B, change the data and set the voltage (A) between the 100 IRE and 0 IRE (pedestal) to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00. Pedestal Pedestal A 2H100 IRE 0 IRE (Pedestal) A 2H Fig. 5-1-18 Fig. 5-1-19
5-24 4. Backlight Consumption Current Adjustment (VF-121 board) Set the backlight luminance and color temperature. If deviated, the image may become dark or bright. Mode Camera Subject Arbitrary Measurement Point + Probe: Pin 2 of CN2904 (EVF BL +) on VI-151 board Ð Probe: Pin 3 of CN2904 (EVF BL Ð) on VI-151 board Measuring Instrument Digital voltmeter Adjustment Page D Adjustment Address 76 Specified Value A = 17.0 ± 1.0mVdc Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 76, change the data and set the voltage difference (A) between Pin 2 of CN2904 (EVF BL +) and Pin 3 of CN2904 (EVF BL Ð) to the specified value. 3) Press the PAUSE button of the adjustment remote commander. 4) Select page: 0, address: 01, and set data: 00.5. White Balance Adjustment (VF-121 board) Correct the white balance. If deviated, the reproduction of the EVF screen may degenerate. Mode Camera Subject Arbitrary Measurement Point Check on EVF screen Measuring Instrument Adjustment Page D Adjustment Address 71, 72 Specified Value The EVF screen should not be colored. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 0B, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 71 and 72, set the data to the initial value. Note:Press the PAUSE button of the adjustment remote commander each time to set the data. 5) Check that the EVF screen is not colored. If colored, change the data of page: D, address: 71 and 72 so that the EVF screen is not colored. Note:To write in the non-volatile memory (EEPROM), press the PAUSE button of the adjustment remote commander each time to set the data. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00. Address Data 71 80 72 80
5-25 1-5. LCD SYSTEM ADJUSTMENT Note 1:The back light (fluorescent tube) is driven by a high voltage AC power supply. Therefore, do not touch the back light holder to avoid electrical shock. Note 2:When replacing the LCD unit, be careful to prevent damages caused by static electricity. Note 3:Set the LCD BRIGHT to the center. Set the LCD COLOR (Menu display) to the center. [Adjusting connector] Most of the measuring points for adjusting the LCD system are concentrated in CN2904 of the VI-151 board. Connect the Measuring Instruments via the CPC-8 jig (J-6082-388- A). The following table shows the Pin No. and signal name of CN2904. Pin No. 1 3 5 7 9 11 13 15 17 19 Signal Name LANC SIG EVF BL Ð EVF VCO PD VG H START PANEL COM TCK TDO SWP GND Pin No. 2 4 6 8 10 12 14 16 18 20 Signal Name EVF BL + EVF VG GND PD VCO XHD/PSIG TMS TDI GND RF IN/LANC JACK IN RF MON Table 5-1-4. 1. VCO Adjustment (PD-101 board) Set the VCO free-run frequency. If deviated, the LCD screen will be blurred. Mode VTR stop Signal arbitrary Measurement Point Pin 9 of CN2904 (H START) on VI-151 board Measuring Instrument Frequency counter Adjustment Page D Adjustment Address 84 Specified Value f = 15734 ± 30Hz (NTSC) f = 15625 ± 30Hz (PAL) Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 03, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 84, change the data and set the frequency (f) to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00. Fig. 5-1-20 CN2904 1 192 20 Remove the CPC cover
5-26 2. D range Adjustment (PD-101 board) Set the D range of the RGB decoder used to drive the LCD to the specified value. If deviated, the LCD screen will become blackish or saturated (whitish). Mode Camera Subject Arbitrary Measurement Point Pin 7 of CN2904 (PD VG) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 82 Specified Value A = 3.56 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 82, change the data and set the voltage (A) between the reversed waveform pedestal and non-reversed waveform pedestal to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00.3. Bright Adjustment (PD-101 board) Set the level of the VIDEO signal for driving the LCD to the specified value. If deviated, the screen image will be blackish or saturated (whitish). Mode Camera Subject Arbitrary Measurement Point Pin 7 of CN2904 (PD VG) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 8A Specified Value A = 1.94 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: 2, address: 0E, and set data: 40. 5) Select page: D, address: 8A, change the data and set the voltage (A) between the pedestal and GAMMA1 limiter level to the specified value. (The data of address: 8A should be Ò1EÓ to ÒA0Ó.) 6) Press the PAUSE button of the adjustment remote commander. 7) Select page: 2, address: 0E, and set data: 00. 8) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 9) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 10) Select page: 0, address: 01, and set data: 00. Pedestal A 2H Pedestal Pedestal A 2H GAMMA 1 limiter level Fig. 5-1-21 Fig. 5-1-22
5-27 4. Contrast Adjustment (PD-101 board) Set the level of the VIDEO signal for driving the LCD to the specified value. If deviated, the screen image will be blackish or saturated (whitish). Mode Camera Subject Arbitrary Measurement Point Pin 7 of CN2904 (PD VG) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 8C Specified Value A = 3.04 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 8C, change the data and set the voltage (A) between the 0 IRE (pedestal) and 100 IRE to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00. 5. V-COM Level Adjustment (PD-101 board) Set the common electrode drive signal level of LCD to the specified value. Mode Camera Subject Arbitrary Measurement Point Pin !Á of CN2904 (PANEL COM) on VI-151 board Measuring Instrument Oscilloscope Adjustment Page D Adjustment Address 83 Specified Value A = 6.85 ± 0.05V Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 3, address: 0C, set data: 20, and press the PAUSE button of the adjustment remote commander. 3) Select page: 3, address: 22, set data: 02, and press the PAUSE button of the adjustment remote commander. 4) Select page: D, address: 83, change the data and set the PANEL COM signal level (A) to the specified value. 5) Press the PAUSE button of the adjustment remote commander. 6) Select page: 3, address: 22, set data: 00, and press the PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 0C, set data: 00, and press the PAUSE button of the adjustment remote commander. 8) Select page: 0, address: 01, and set data: 00. 0 IRE100 IRE A 2H A 2H Fig. 5-1-23 Fig. 5-1-24