    							5-18
    15. White Balance Check
    Subject Clear chart
    (Color bar standard picture frame)
    Filter Filter C14 for color temperature
    correction
    ND filter 1.0 and 0.3
    Measurement Point Video output terminal
    Measuring Instrument Vectorscope
    Specified Value Fig. 5-1-11. A to C
    Checking method:
    1) Check that the lens is not covered with either filter.
    2) Select page: 6, address: 01, set data: 0F, and press the PAUSE
    button of the adjustment remote commander.
    3) Check that the center of the white luminance point is within
    the circle shown Fig. 5-1-11. A.
    4) Select page: 6, address: 01, set data: 23, and press the PAUSE
    button of the adjustment remote commander.
    5) Place the C14 filter on the lens.
    6) Check that the center of the white luminance point settles in
    the circle shown Fig. 5-1-11.B.
    7) Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3)
    on the lens.
    8) Check that the white luminance point stopped moving, and then
    remove the ND filter 1.3.
    9) Check that the center of the white luminance point settles within
    the circle shown Fig. 5-1-11.C.
    Processing after Completing Adjustments
    1) Select page: 6, address: 01, and set data: 00, and press the
    PAUSE button of the adjustment remote commander.
    R-Y 2mm
    B-Y
    2mm
    R-Y
    B-
    Y
    1.0mm1.0mm
    3mm
    3mm
    R-Y
    B-
    Y
    3mm
    3mm
    2.0mm
    1.0mm
    Fig. 5-1-11 (A)
    Fig. 5-1-11 (B)
    Fig. 5-1-11 (C) 
    						
    							5-19
    16. PSD Sensor Gain Adjustment
    Adjust the gain of the PSD sensor for steady shot operation.
    16-1. PSD Sensor Gain Adjustment (1)
    Subject Pattern A
    (1.5m from the front of the lens)
    Measurement Point Video output terminal
    Measuring Instrument Oscilloscope
    (V period)
    Adjustment Page E
    Adjustment Address 48
    Fig.5-1-12.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: E, address: 48, set data: 80, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 6, address: 01, set data: 8F, and press the PAUSE
    button of the adjustment remote commander.
    4) Expose pattern A with the zoom TELE end.
    5) Adjust the focus.
    6) Measure the vertical position SV1 (msec) of the falling edge
    of the waveform. (Oscilloscope is V period)
    7) Select page: 6, address: 01, set data: 91, and press the PAUSE
    button.
    8) Measure the vertical position SV2 (msec) of the falling edge
    of the waveform. (Oscilloscope is V period)
    9) Obtain D48 using the following equation (decimal calculation).
    NTSC model
    D
    48 = 128 ´ (2.88/(SV2ÐSV1))
    PAL model
    D
    48 = 128 ´ (3.40/(SV2ÐSV1))
    10) Convert D
    48 to hexadecimal notation, and obtain D48.    (Round
    off to one decimal place)
    (Refer to Table 5-4-1. ÒHexadecimal notation-Decimal notation
    conversion tableÓ of Ò5-4. Service ModeÓ. )
    11) Select page: E, address: 48, set data: D
    48, and press the PAUSE
    button of the adjustment remote commander.
    Processing after Completing Adjustments
    1) Select page: 6, address: 01, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    2) Select page: 0, address: 01, and set data: 00.
    3) Check that the steady shot operation is performed normally.
    Fig. 5-1-13.
    White White Pattern A
    A4 size (297mm 
    ´ 210mm) Black
    V
    SV1 (msec)SV2 (msec)SV2–SV1 Falling edge of 
    waveform when 
    data is “91” Falling edge of 
    waveform when 
    data is “8F” 
    						
    							5-20
    16-2. PSD Sensor Gain Adjustment (2)
    Subject Pattern B
    (1.5m from the front of the lens)
    Measurement Point Video output terminal
    Measuring Instrument Oscilloscope
    (H period)
    Adjustment Page E
    Adjustment Address 49
    Fig.5-1-14.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: E, address: 49, set data: 80, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 6, address: 01, set data: 8F, and press the PAUSE
    button of the adjustment remote commander.
    4) Expose pattern B with the zoom TELE end.
    5) Adjust the focus.
    6) Measure the horizontal position SH1 (msec) of the falling edge
    of the waveform. (Oscilloscope is H period)
    7) Select page: 6, address: 01, set data: 91, and press the PAUSE
    button.
    8) Measure the horizontal position SH2 (msec) of the falling edge
    of the waveform. (Oscilloscope is H period)
    9) Obtain D49 using the following equation (decimal calculation).
    D
    49 = 128 ´ (7.4/(SH2ÐSH1))
    10) Convert D
    49 to hexadecimal notation, and obtain D49.    (Round
    off to one decimal place)
    (Refer to Table 5-4-1. ÒHexadecimal notation-Decimal notation
    conversion tableÓ of Ò5-4. Service ModeÓ. )
    11) Select page: E, address: 49, set data: D
    49, and press the PAUSE
    button of the adjustment remote commander.
    Processing after Completing Adjustments
    1) Select page: 6, address: 01, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    2) Select page: 0, address: 01, and set data: 00.
    3) Check that the steady shot operation is performed normally.
    Fig. 5-1-15.
    White WhiteBlack
    Pattern B
    A4 size (297mm 
    ´ 210mm)
    H
    SH1 (msec)SH2 (msec)SH2–SH1 Falling edge of 
    waveform when 
    data is “91” Falling edge of 
    waveform when 
    data is “8F” 
    						
    							5-21
    17. Angular Velocity Sensor Sensitivity Adjustment
    ¥ This adjustment is performed only when replacing the angular
    velocity sensor.
    Although this adjustment need not be performed when the circuit
    is damaged, etc., check the operations.
    ¥ Note down the sensitivity displayed on the angular velocity sensor
    of the repair parts. At this time, note down also to which board it
    was attached to.
    Be sure to check because if attached incorrectly, the screen will
    vibrate up and down or left and right during hand-shake correction
    operations.
    Precautions on the Parts Replacement
    There are two types of repair parts.
    Type A ENC03JA
    Type B ENC03JB
    Replace the broken sensor with a same type sensor. If replace with
    other type parts, the image will vibrate up and down or left and
    right during hand-shake correction operations. After replacing, re-
    adjust according to the adjusting method after replacement.
    Precautions on Angular Velocity Sensor
    The sensor incorporates a precision oscillator. Handle it with care
    as if it dropped, the balance of the oscillator will be disrupted and
    operations will not be performed properly.
    Adjustment Page F
    Adjustment Address 41,  42
    Note:The sensor sensitivity of SE450 and SE451 of  the SE-75 board is
    written only on the repair parts.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Read the sensor sensitivity written on SE450 of the SE-75
    board, and take this as S
    450.
    3) Read the sensor sensitivity written on SE451 of the SE-75
    board, and take this as S
    451.
    4) Calculate D
    41 and D42 using the following equation (decimal
    calculation).
    D
    41 = 80 ´ (0.60/S451)
    D
    42 = 80 ´ (0.60/S450)
    5) Convert D
    41 and D42 into hexadecimal digits, to obtain D41
    and D42. (Round off decimal points)
    6) Select page: F, address: 41, set data: D
    41, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: F, address: 42, set data: D
    42, and press the PAUSE
    button of the adjustment remote commander.
    Processing after Completing Adjustments
    1) Select page: 0, address: 01, and set data: 00.
    2) Check that the steady shot operations have been performed
    normally. 
    						
    							5-22
    H
    A
    GND level
    (0Vdc)
    Pin No.
    1
    3
    5
    7
    9
    11
    13
    15
    17
    19
    Signal Name
    LANC SIG
    EVF BL Ð
    EVF VCO
    PD VG
    H START
    PANEL COM
    TCK
    TDO
    SWP
    GND
    Pin No.
    2
    4
    6
    8
    10
    12
    14
    16
    18
    20
    Signal Name
    EVF BL +
    EVF VG
    GND
    PD VCO
    XHD/PSIG
    TMS
    TDI
    GND
    RF IN/LANC JACK IN
    RF MON
    1-4. COLOR ELECTRONIC VIEWFINDER
    SYSTEM ADJUSTMENT
    Note 1:The back light (fluorescent tube) is driven by a high voltage AC
    power supply. Therefore, do not touch the back light holder to
    avoid electrical shock.
    Note 2:When replacing the LCD unit, be careful to prevent damages
    caused by static electricity.
    Note 3:Set the VF BRIGHT (Menu display) to the center.
    [Adjusting connector]
    Most of the measuring points for adjusting the viewfinder system
    are concentrated in CN2904 of the VI-151 board.
    Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
    A).
    The following table shows the Pin No. and signal name of CN2904.
    Table 5-1-3.
    1. VCO Adjustment (VF-121 board)
    Set the VCO free-run frequency. If deviated, the EVF screen will be
    blurred.
    Mode VTR stop
    Signal Arbitrary
    Measurement Point Pin 5 of CN2904 (EVF VCO) on
    VI-151 board
    Measuring Instrument Oscilloscope (DC range)
    Adjustment Page D
    Adjustment Address 75
    Specified Value A = 1.7 ± 0.2V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Check the GND level of the oscilloscope.
    3) Select page: D, address: 75, change the data and set the VCO
    output voltage (A) to the specified value.
    4) Press the PAUSE button of the adjustment remote commander.
    5) Select page: 0, address: 01, and set data: 00.
    Fig. 5-1-16Fig. 5-1-17
    CN2904
    1
    192
    20
    Remove the CPC cover 
    						
    							5-23
    2. Bright Adjustment (VF-121 board)
    Set the level of the VIDEO signal for driving the LCD to the specified
    value. If deviated, the screen image will be blackish or saturated
    (whitish).
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin 4 of CN2904 (EVF VG) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 7A
    Specified Value A = 7.25 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 7A, change the data and set the voltage
    (A) between the reversed waveform pedestal and non-reversed
    waveform pedestal to the specified value.
    (The data of address: 7A should be Ò54Ó to ÒD7Ó.)
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.3. Contrast Adjustment (VF-121 board)
    Set the level of the VIDEO signal for driving the LCD to the specified
    value. If deviated, the screen image will be blackish or saturated
    (whitish).
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin 4 of CN2904 (EVF VG) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 7B
    Specified Value A = 1.81 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 7B, change the data and set the voltage
    (A) between the 100 IRE and 0 IRE (pedestal) to the specified
    value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.
    Pedestal
    Pedestal
    A
    2H100 IRE
    0 IRE (Pedestal)
    A
    2H
    Fig. 5-1-18 Fig. 5-1-19 
    						
    							5-24
    4. Backlight Consumption Current Adjustment
        (VF-121 board)
    Set the backlight luminance and color temperature.
    If deviated, the image may become dark or bright.
    Mode Camera
    Subject Arbitrary
    Measurement Point + Probe: Pin 2 of CN2904 (EVF BL +)
    on VI-151  board
    Ð Probe: Pin 3 of CN2904 (EVF BL Ð)
    on VI-151  board
    Measuring Instrument Digital voltmeter
    Adjustment Page D
    Adjustment Address 76
    Specified Value A = 17.0 ± 1.0mVdc
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: D, address: 76, change the data and set the voltage
    difference (A) between Pin 2 of CN2904 (EVF BL +) and
    Pin 3 of CN2904 (EVF BL Ð) to the specified value.
    3) Press the PAUSE button of the adjustment remote commander.
    4) Select page: 0, address: 01, and set data: 00.5. White Balance Adjustment (VF-121 board)
    Correct the white balance.
    If deviated, the reproduction of the EVF screen may degenerate.
    Mode Camera
    Subject Arbitrary
    Measurement Point Check on EVF screen
    Measuring Instrument
    Adjustment Page D
    Adjustment Address 71, 72
    Specified Value The EVF screen should not be
    colored.
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 0B, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 71 and 72, set the data to the initial
    value.
    Note:Press the PAUSE button of the adjustment remote commander
    each time to set the data.
    5) Check that the EVF screen is not colored. If colored, change
    the data of page: D, address: 71 and 72 so that the EVF screen
    is not colored.
    Note:To write in the non-volatile memory (EEPROM), press the
    PAUSE button of the adjustment remote commander each time
    to set the data.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.
    Address
    Data
    71
    80
    72
    80 
    						
    							5-25 1-5. LCD SYSTEM ADJUSTMENT
    Note 1:The back light (fluorescent tube) is driven by a high voltage AC
    power supply. Therefore, do not touch the back light holder to
    avoid electrical shock.
    Note 2:When replacing the LCD unit, be careful to prevent damages
    caused by static electricity.
    Note 3:Set the LCD BRIGHT to the center.
    Set the LCD COLOR (Menu display) to the center.
    [Adjusting connector]
    Most of the measuring points for adjusting the LCD system are
    concentrated in CN2904 of the VI-151 board.
    Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
    A).
    The following table shows the Pin No. and signal name of CN2904.
    Pin No.
    1
    3
    5
    7
    9
    11
    13
    15
    17
    19
    Signal Name
    LANC SIG
    EVF BL Ð
    EVF VCO
    PD VG
    H START
    PANEL COM
    TCK
    TDO
    SWP
    GND
    Pin No.
    2
    4
    6
    8
    10
    12
    14
    16
    18
    20
    Signal Name
    EVF BL +
    EVF VG
    GND
    PD VCO
    XHD/PSIG
    TMS
    TDI
    GND
    RF IN/LANC JACK IN
    RF MON
    Table 5-1-4.
    1. VCO Adjustment (PD-101 board)
    Set the VCO free-run frequency. If deviated, the LCD screen will
    be blurred.
    Mode VTR stop
    Signal arbitrary
    Measurement Point Pin 9 of CN2904 (H START) on
    VI-151 board
    Measuring Instrument Frequency counter
    Adjustment Page D
    Adjustment Address 84
    Specified Value f = 15734 ± 30Hz (NTSC)
    f = 15625 ± 30Hz (PAL)
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 03, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 84, change the data and set the
    frequency (f) to the specified value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.
    Fig. 5-1-20
    CN2904
    1
    192
    20
    Remove the CPC cover 
    						
    							5-26
    2. D range Adjustment (PD-101 board)
    Set the D range of the RGB decoder used to drive the LCD to the
    specified value. If deviated, the LCD screen will become blackish
    or saturated (whitish).
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin 7 of CN2904 (PD VG) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 82
    Specified Value A = 3.56 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 82, change the data and set the voltage
    (A) between the reversed waveform pedestal and non-reversed
    waveform pedestal to the specified value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.3. Bright Adjustment (PD-101 board)
    Set the level of the VIDEO signal for driving the LCD to the specified
    value. If deviated, the screen image will be blackish or saturated
    (whitish).
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin 7 of CN2904 (PD VG) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 8A
    Specified Value A = 1.94 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: 2, address: 0E, and set data: 40.
    5) Select page: D, address: 8A, change the data and set the voltage
    (A) between the pedestal and GAMMA1 limiter level to the
    specified value. (The data of address: 8A should be Ò1EÓ to
    ÒA0Ó.)
    6) Press the PAUSE button of the adjustment remote commander.
    7) Select page: 2, address: 0E, and set data: 00.
    8) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    9) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    10) Select page: 0, address: 01, and set data: 00.
    Pedestal
    A
    2H Pedestal 
    Pedestal
    A
    2H GAMMA 1 limiter level
    Fig. 5-1-21 Fig. 5-1-22 
    						
    							5-27
    4. Contrast Adjustment (PD-101 board)
    Set the level of the VIDEO signal for driving the LCD to the specified
    value. If deviated, the screen image will be blackish or saturated
    (whitish).
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin 7 of CN2904 (PD VG) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 8C
    Specified Value A = 3.04 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 8C, change the data and set the voltage
    (A) between the 0 IRE (pedestal) and 100 IRE to the specified
    value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.
    5. V-COM Level Adjustment (PD-101 board)
    Set the common electrode drive signal level of LCD to the specified
    value.
    Mode Camera
    Subject Arbitrary
    Measurement Point Pin !Á of CN2904 (PANEL COM) on
    VI-151 board
    Measuring Instrument Oscilloscope
    Adjustment Page D
    Adjustment Address 83
    Specified Value A = 6.85 ± 0.05V
    Adjusting method:
    1) Select page: 0, address: 01, and set data: 01.
    2) Select page: 3, address: 0C, set data: 20, and press the PAUSE
    button of the adjustment remote commander.
    3) Select page: 3, address: 22, set data: 02, and press the PAUSE
    button of the adjustment remote commander.
    4) Select page: D, address: 83, change the data and set the PANEL
    COM signal level (A) to the specified value.
    5) Press the PAUSE button of the adjustment remote commander.
    6) Select page: 3, address: 22, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
    button of the adjustment remote commander.
    8) Select page: 0, address: 01, and set data: 00.
    0 IRE100 IRE
    A
    2H
    A
    2H
    Fig. 5-1-23 Fig. 5-1-24 
    						