5-8 Address 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B Initial value NTSC 80 80 D5 EC 20 20 PA L 80 80 D5 EC 20 20 Remark Fixed data-1 (Initialized data) PSD sensor gain adj. Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Color reproduction adj. (2) (ND filter ON) Fixed data-1 Fixed data-2 Fixed data-1 (Initialized data) 4. E Page tableNote 1:Fixed data-1 : Initialized data. (Refer to Ò1. Initializing the F, E Page DataÓ.) Fixed data-2 : Modified data. (Refer to Ò2. Modification of F, E PAGE DataÓ). Address 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 Initial value NTSC 40 40 80 80 80 PA L 40 40 80 80 80 Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Pre white balance data input Fixed data-1 OFFSET adj. Fixed data-1 (Initialized data)
5-9 Address 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C to FF Initial value NTSCPA LRemark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 (Initialized data) Table. 5-1-2
5-10 1-3. CAMERA SYSTEM ADJUSTMENTS Before perform the camera system adjustments, check that the specified value of ÒComposite Output Y Level AdjustmentÓ and ÒComposite Output Chroma Level AdjustmentÓ of ÒBase band Block AdjustmentÓ of ÒVIDEO SYSTEM ADJUSTMENTÓ are satisfied. 1. 27 MHz Origin Oscillation Adjustment (VC-208 board) Set the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Not required Measurement Point Pin $¦ of IC204 or Pin @ª of IC207 or Pin &¦ of IC300 Measuring Instrument Frequency counter Adjustment Page F Adjustment Address 1C Specified Value f=13500000 ± 68Hz Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: F, address: 1C, change the data and set the clock frequency(f) to the specified value. 3) Press the PAUSE button of the adjustment remote commander. 4) Select page: 0, address: 01, and set data: 00. 2. IRIS & ND HALL Auto Adjustment For detecting the position of the lens iris and ND filter, adjust the hall AMP gain and offset. Subject Not required Measurement Point DDS display data of LCD or TV monitor (Note 5) Measuring Instrument Adjustment Page F Adjustment Address 1E, 1F, 48, 49, 4C, 70 Specified Value IRIS display data : 88 to 8A during IRIS OPEN (Note 1) 14 to 18 during IRIS CLOSE (Note 2) ND display data : 14 to 18 during ND filter OFF (Note 3) 88 to 8A during ND filter ON (Note 4) Note 1:Select page: 6, address: 01, set data: 01, and press the PAUSE button of the adjustment remote commander. Note 2:Select page: 6, address: 01, set data: 03, and press the PAUSE button of the adjustment remote commander. Note 3:Select page: 6, address: 1C, and set data: 02. Note 4:Select page: 6, address: 1C, and set data: 03. Note 5:DDS display data of LCD or TV monitor. CA 00 0000 CA 00 YY XX IRIS display data ND display data Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 94, and set data: 89. 3) Select page: 6, address: 95, and set data: 16. 4) Select page: 6, address: 01, set data: 6D, and press the PAUSE button of the adjustment remote commander. (The HALL adjustment is performed and the adjustment data is stored in page: F, address: 1E, 1F, 48, 49, 4C and 70.) 5) Select page: 6, address: 02, and check that the data is Ò01Ó.Processing after Completing Adjustments 1) Select page: 6, address: 94, and set data: 00. 2) Select page: 6, address: 95, and set data: 00. 3) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 4) Select page: 0, address: 01, and set data: 00. Checking method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 11, set data: 02, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 04, and set data: 03. 4) Select page: 6, address: 01, set data: 01, and press the PAUSE button. 5) Check the IRIS display data lies within the Ò88Ó to Ò8AÓ range. 6) Select page: 6, address: 01, set data: 03, and press the PAUSE button. 7) Check the IRIS display data lies within the Ò14Ó to Ò18Ó range. 8) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 9) Select page: 6, address: 1C, and set data: 02. 10) Check the ND display data lies within the Ò14Ó to Ò18Ó range. 11) Select page: 6, address: 1C, and set data: 03. 12) Check the ND display data lies within the Ò88Ó to Ò8AÓ range. Processing after Completing Check 1) Select page: D, address: 11, and set data: 00, and press the PAUSE button. 2) Select page: 0, address: 01, and set data: 00. 3) Select page: 6, address: 01, and set data: 00, and press the PAUSE button. 4) Select page: 6, address: 1C, and set data: 00. 1121324 25 36 37 48 IC 207 26 505175 76 100 1 25 IC300 1121324 25 36 37 48 IC 204 VC-208 board (SIDE A) VC-208 board (SIDE B)
5-11 3. Offset Adjustment Adjust so that the AGC OUT potential lies within the specified value of the digital clamp. Subject Not required Measurement Point DDS display data of LCD or TV monitor (Note 1) Measuring Instrument Adjustment Page E Adjustment Address 2D, 2E, 2F Specified Value 50 to B0 Note 1: DDS display data of LCD or TV monitor. CA 00 0000 CA 00 00 XX Object data Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 11, set data: 02, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 01, set data: 07 and press the PAUSE button. 4) Select page: 6, address: 04, and set data: 1F. 5) Check the DDS display data (Rch OPB) satisfies the specified value. If not perform the Rch offset adjustment. 6) Select page: 6, address: 04, and set data: 20. 7) Check the DDS display data (Gch OPB) satisfies the specified value. If not perform the Gch offset adjustment. 8) Select page: 6, address: 04, and set data: 21. 9) Check the DDS display data (Bch OPB) satisfies the specified value. If not perform the Bch offset adjustment. 10) Select page: 6, address: 01, and set data: 05 and press the PAUSE button. 11) Select page: 6, address: 04, and set data: 1F. 12) Check the DDS display data (Rch OPB) satisfies the specified value. If not perform the Rch offset adjustment. 13) Select page: 6, address: 04, and set data: 20. 14) Check the DDS display data (Gch OPB) satisfies the specified value. If not perform the Gch offset adjustment. 15) Select page: 6, address: 04, and set data: 21. 16) Check the DDS display data (Bch OPB) satisfies the specified value. If not perform the Gch offset adjustment. ¥ Rch offset adjustment 1) Select page: E, address: 0C, set data: 02, and press the PAUSE button. 2) Select page: E, address: 2D, change the data and adjust the DDS display data to the specified value. ¥ Gch offset adjustment 1) Select page: E, address: 0C, set data: 02, and press the PAUSE button. 2) Select page: E, address: 2E, change the data and adjust the DDS display data to the specified value. ¥ Bch offset adjustment 1) Select page: E, address: 0C, set data: 02, and press the PAUSE button. 2) Select page: E, address: 2F, change the data and adjust the DDS display data to the specified value.Processing after Completing Adjustments 1) Select page: D, address: 11, set data: 00, and press the PAUSE button. 2) Select page: E, address: 0C, set data: 00, and press the PAUSE button. 3) Select page: 0, address: 01, and set data: 00. 4) Select page: 6, address: 01, and set data: 00, and press the PAUSE button. 5) Select page: 6, address: 04, and set data: 00.
5-12 Address 24 25 26 27 28 29 36 PA L 2C 17 78 1D FB 12 D6 Address 37 38 39 3A 3B 3C 3D PA L E6 23 00 19 00 27 A8 4. Flange Back Adjustment The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 4-1. Flange Back Adjustment(1) Subject Flange back adjustment chart (2.0 m from the front of the lens) (Luminance: 230 ± 30 lux) Measurement Point Check operation on TV monitor Measuring Instrument Adjustment Page F Adjustment Address 24 to 29, 36 to 3D Adjusting method: 1) Check that at both the zoom lens TELE end and WIDE end, the center of the chart for the flange back adjustment and center of the exposure screen coincide. 2) Select page: 0, address: 01, and set data: 01. 3) Check that the data of page: F, address: 24 to 29, 36 to 3D is the initial value (See table below). 4) Select page: 6, address: 02, and check that the data is Ò00Ó. 5) Select page: 6, address: 01, set data: 13, and press the PAUSE button of the adjustment remote commander. 6) Select page: 6, address: 01, set data: 15, and press the PAUSE button of the adjustment remote commander. ( The adjustment data will be automatically input to page: F, addresses: 24 to 29, 36 to 3D.) 7) Select page: 6, address: 02, and check that the data is Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Perform ÒFlange Adjustment (2)Ó. NTSC 8E 1A 80 24 65 11 D6 NTSC E6 15 45 3F 3F 16 A8 Data Data 4-2. Flange Back Adjustment (2) Perform this adjustment after performing ÒFlange Back Adjustment (1)Ó. Subject Subject more than 500m away (Subjects with clear contrast such as buildings, etc.) Measurement Point Check operation on TV monitor Measuring Instrument Adjustment Page F Adjustment Address 24 to 29, 36 to 3D Adjusting method: 1) Set the zoom lens to the TELE end and expose a subject that is more than 500 m away (subject with clear contrast such as building, etc.). (Nearby subjects less than 500 m away should not be in the screen.) 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 6, address: 02, and check that the data is Ò00Ó. 4) Select page: 6, address: 01, set data: 13, and press the PAUSE button of the adjustment remote commander. 5) Place a ND filter on the lens so that the optimum image is obtain. 6) Select page: 6, address: 01, set data: 29, and press the PAUSE button of the adjustment remote commander. (The adjustment data will be automatically input to page: F, addresses: 24 to 29, 36 to 3D.) 7) Select page: 6, address: 02, and check that the data is Ò01Ó. Processing after Completing Adjustments 1) Select page: 0, address: 01, and set data: 00. 2) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 3) Perform ÒFlange Back CheckÓ.
5-13 A=B C=D ABC D t=0 ± 0.1msec V Color bar chart picture frame TV monitor picture frame 5. Flange Back Check Subject Siemens star (2.0 m from the front of the lens) (Luminance: 300 ± 50 lux) Measurement Point Check operation on TV monitor Measuring Instrument Specified Value Focused at the TELE end and WIDE end. Switch setting: 1) DIGITAL ZOOM (Menu display) ................................... OFF Checking method: 1) Place the Siemens star 2.0m from the front of the lens. 3) Shoot the Siemens star with the zoom TELE end. 4) Turn on the auto focus. 5) Check that the lens is focused (Note). 6) Turn off the auto focus. 7) While observe the TV monitor, change the zoom to the WIDE end and check that the lens is focused. Note :When the auto focus is ON, the lens can be checked if it is focused or not by observing the data on the page 1 of the adjustment remote commander. 1) Select page: 6, address: 04, and set data: 0F. 2) Page 1 shows the state of the focus. 1 : 00 : XX Odd: Focused Even: Unfocused Processing after Completing Adjustments 1) Select page: 6, address: 04, and set data: 00.6. Picture Frame Setting Subject Color bar chart standard picture frame (95cm from the front of the lens) Measurement Point Video output terminal Measuring Instrument Oscilloscope and TV monitor Specified Value A=B, C=D, t=0 ± 0.1msec Setting method: 1) Adjust the zoom and the camera direction, and set to the specified position. 2) Mark the position of the picture frame on the monitor display, and adjust the picture frame to this position in following adjustments using ÒColor bar chart standard picture frameÓ. Check on the oscilloscope 1. Horizontal period Fig. 5-1-6 2. Vertical period Fig. 5-1-7 Color on the TV monitor Fig. 5-1-8
5-14 7. Pre White Balance Data Input At 3200k, input the pre white balance standard data. Subject Clear chart (Color bar standard picture frame) Adjustment Page E Adjustment Address 2A, 2B Switch setting: 1) ND filter ........................................................................... OFF Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 1C, and set data: 02. 3) Select page: F, address: 20, and set data: 00, and press the PAUSE button of the adjustment remote commander. 4) Select page: F, address: 21, set data: 28, and press the PAUSE button. 5) Select page: F, address: 22, set data: 00, and press the PAUSE button. 6) Select page: F, address: 23, set data: 50, and press the PAUSE button. 7) Select page: 6, address: 01, set data: 7F, and press the PAUSE button. 8) Select page: 6, address: 01, and set data: 7D, press the PAUSE button. (When the standard data is take in, the data will be automatically input to page: E, address: 2A and 2B.) 9) Select page: 6, address: 02, and check that the data is Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 6, address: 1C, and set data: 00. 3) Select page: 0, address: 01, and set data: 00. 4) Perform ÒAuto White Balance Standard Data InputÓ.8. Auto White Balance Standard Data Input At 3200K, input the white balance standard data. Subject Clear chart (Color bar standard picture frame) Adjustment Page F Adjustment Address 20 to 23 Note 1: Perform ÒPre White Balance Data InputÓ before this adjustment. Note 2:Check that the data of page: 6, address: 02 is 00. If not, turn the power of the unit OFF/ON. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 01, and set data: 11, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 01, and set data: 0B, and press the PAUSE button. (When the standard data is take in, the data will be automatically input to page: F, address: 20 to 23.) 4) Select page: 6, address: 02, and check that the data is Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 0, address: 01, and set data: 00.
5-15 9. MAX GAIN Adjustment Setting the minimum illumination. If it is not consistent, the image level required for taking subjects in low illuminance will not be produced (dark). Subject Clear chart (Color bar standard picture frame) (95cm from the front of the lens) Adjustment Page F Adjustment Address 2C Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 96, and set data: 00. 3) Select page: 6, address: 97, and set data: 2C. 4) Select page: 6, address: 01, set data: 6F and press the PAUSE button of the adjustment remote commander. (When the adjustment data is take in, the data will be automatically input to page: F, address: 2C.) 5) Select page: 6, address: 02, and check that the data is changed to Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 96, and set data: 00. 2) Select page: 6, address: 97, and set data: 00. 3) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 4) Select page: 0, address: 01, and set data: 00.10. LV Standard Data Input Adjust the normal coefficient of the light value. Subject Clear chart (Color bar standard picture frame) Adjustment Page F Adjustment Address 3E, 3F Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 01, and set data: 0D, and press the PAUSE button of the adjustment remote commander. (When the adjustment data is take in, the data will be automatically input to page: F, address: 3E and 3F.) Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 0, address: 01, and set data: 00.
5-16 11. White Balance ND Filter Compensation Adjustment Compensate the white balance deviation when ND filter is ON. Subject Clear chart (Color bar standard picture frame) Adjustment Page F Adjustment Address 4A, 4B Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 1C, and set data: 03. 3) Wait for 2 seconds. 4) Select page: 6, address: 01, and set data: 11, and press the PAUSE button of the adjustment remote commander. 5) Select page: 6, address: 01, and set data: 09, and press the PAUSE button. (When the adjustment data is take in, the data will be automatically input to page: F, address: 4A and 4B.) 6) Select page: 6, address: 02, and check that the data is changed to Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 6, address: 1C, and set data: 00. 3) Select page: 0, address: 01, and set data: 00.12. Auto White Balance Adjustment Adjust to the proper auto white balance output data. If it is not correct, auto white balance and color reproducibility will be poor. Subject Clear chart (Color bar standard picture frame) Filter Filter C14 for color temperature correction Adjustment Page F Adjustment Address 34, 35 Adjusting method: 1) Place the C14 filter for color temperature correction on the lens. 2) Select page: 0, address: 01, and set data: 01. 3) Select page: 6, address: 01, set data: 83, and press the PAUSE button of the adjustment remote commander. 4) Select page: 6, address: 01, set data: 81, and press the PAUSE button. (When the adjustment data is take in, the data will be automatically input to page: F, address: 34 and 35.) 5) Select page: 6, address: 02, and check that the data is changed to Ò01Ó. Processing after Completing Adjustments 1) Select page: 6, address: 01, and set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 0, address: 01, and set data: 00.
5-17 13. Color Reproduction Adjustment (ND Filter OFF) When the ND filter is off, adjust the color difference matrix coefficient so that proper color reproduction is produced. Subject Color bar chart standard picture frame Measurement Point Video output terminal Measuring Instrument Vectorscope Adjustment Page F Adjustment Address 44, 45, 46, 47 Specified Value All color luminance points should settle within each color reproduction frame. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: F, address: 5E, set data: 1C, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 01, set data: 61, and press the PAUSE button of the adjustment remote commander. 4) Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. 5) Change the data of page: F, address: 44, 45, 46 and 47, and settle each color luminance point in each color reproduction frame. Note :Be sure to press the PAUSE button of the adjustment remote commander before changing the addresses. If not, the new data will not be written to the memory. Processing after Completing Adjustments 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: F, address: 5E, set data: 25, and press the PAUSE button. 3) Select page: 0, address: 01, and set data: 00.14. Color Reproduction Adjustment (ND Filter ON) When the ND filter is on, adjust the color difference matrix coefficient so that proper color reproduction is produced. Subject Color bar chart standard picture frame Measurement Point Video output terminal Measuring Instrument Vectorscope Adjustment Page E Adjustment Address 62, 63, 64, 65 Specified Value All color luminance points should settle within each color reproduction frame. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: F, address: 5E, set data: 1C, and press the PAUSE button of the adjustment remote commander. 3) Select page: 6, address: 1C, set data: 03. 4) Wait for 2 seconds. 5) Select page: 6, address: 01, set data: 85, and press the PAUSE button of the adjustment remote commander. 6) Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. 7) Change the data of page: E, address: 62, 63, 64 and 65, and settle each color luminance point in each color reproduction frame. Note :Be sure to press the PAUSE button of the adjustment remote commander before changing the addresses. If not, the new data will not be written to the memory. Processing after Completing Adjustments 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. 2) Select page: 6, address: 1C, set data: 00. 3) Select page: F, address: 5E, set data: 25, and press the PAUSE button. 4) Select page: 0, address: 01, and set data: 00. NTSC burst position PAL burst position NTSC burst position PAL burst position Fig. 5-1-9 Fig. 5-1-10