. . SET-30 INSTAUAZION AND PROGRAMMING The following informgtion is a SylnOpSiS df the installation and programming proceduresoutlined in the SET-30 Documentation Package. It is intended to provide the craftsperson with a quick over- view of the steps- which have to be taken to install and program a SET-30. For more detailed information,referto the Documentation Package. i.-.,” -2-
SET-30 SPECIFICATIONS AUTOCOM Number of Loops PBX Loop Resistance Loop TypePower Loop Resistance Power Loop Distance Voltage Hold Frequence Response Tones Keys Display Speakerphones Handset Data Retention FCC Specification2 + Intercom 1200 Ohm maximum Loop Start 120 Ohm maximum 2200 FT @ 24 GA 24 to 56 VDC Non-polarity Sensitive Hard hold on all lines 300 -.3,400 Hz ;kandard 12 DTMF 32 5x7 matrix,alphanumeric character, LCD technology Integral - Half Duplex Standard K-type with modular connection 6 Years without power Meets or exceed parts: 15 subpart J- Class A (EMI) 68 (network connection) MULTIPLEXER PBX Loop Type PBX Lines Secretary Stations Power ConnectionLoop Start 8 (32 with 4 multiplexers) 1 (2 on Multiplex II version) 42-56 VDC, 200 MA plus 200 MA per phone maximum Polarity sensitive All specifications and prices are subject to change without notice. -3-
FORM Note:These items are supplied by Siemens-.a.?y----_-c------------------------_ ___-----------------________________o___--------------------------_____------------------------------------- t ITEMNOMENCLATUREDESCRIPTION QUANTITY I I----------------------------- -------------------------__--------------------------------------------------------------------------------__ I Programmable SET-30 Telephone 1 PN-X5051-Al001 (Exec. See lr 2# orPrivate) I I-I 121Multiplexer 1 PN-X5051-Al.02 13iMultiplexer PN-X5051-A103 2I-I I 4 I Power buffer Card PN-X5051-Al.04 i 5 i Local Power Adapter II 24 vdc 0:25A PN-X5051-Al01 I I I Single Secretary Multiplexer I iw/8 power corm.I I Dual Secretary Multiplexer .w/8/ Ipower corm.I -i I For up to 25 SET-30EsI 1Provides fused power corm.I-I I f Power supply for one SET-30 / I II i-iii I 6 I Card Cage AssemblyI Holds up to 13 multiplexer I IPN-X5051-Al05I assemblies.Requires power III I I-I 1 supply.I II (. ,’ .’ , ‘\,.::.,I , -4-
/---. SET-30 can be programmed to operatein any ofthe .configurations shown below: 1.2 dedicated line buttons stand-alone EXECUTIVE station. 2.2 dedicated line buttons plus intercom station (with private or group secretary).button EXECUTIVE 3.2 dedicated line buttons plusintercom button PRIVATE SECRETARY station, (serving one EXECUTIVE station). 4.4 nondedicated line buttons plus intercom ‘button‘ GROUP SECRETARY station, serving UP to 32 EXECUTIVE stations or nonexecutive stations (2500) phones). 5.5 non-dedicated line buttons(without intercom)GROUP SECRETARY station serving up to 32 EXECUTIVE stations or nonexecutive stations (2500 phones). The first or onlysecretary station ofthis type is programmed as SECRETARY 1.If a second secretary station is used,it is programmed as SECRETARY 2. Stand-Alone EXECUTIVE stations are connected to the PBX only. :One EXECUTIVE, one SECRETARY combinations are connected to the PBX only with an intercom line between the two stations. If one SECRETARY station screens callsfor more than one EXECUTIVE _ station a Multiplexer I card is required. If two SECRETARY stations(both) screencalls for EXECUTIVE stations,a Multiplexer II card is required. Each Multiplexer group may use upto four 8-port multiplexer cards (of the same type). SET-30 is powered locally, using an AC to DC converter,or con- nected to a multiplexer card,or connected to a power buffer card. Each power buffercardsupplies power for 25 instruments, individually fused at 400 ma @ 48V. A 16-slot card cageis used to house‘ multiplexer and power buffer cards. Multiplexer cards for the same group are placed in adjacent slots. Each multiplexer group is separated by an empty slot. If power buffercards are used, they may be placed in any unoc- _, cupied slot, including the emptyslot between multiplexer groups. -5-
. Power to the cage for the multiplexerand buffer cards is -48v and /---..; ~ground from a separate power supply. Total= 200 ma @ 48V X (number of multiplexer-“\: cards +number ofmultiplexerand,. buffer ports used) Each multiplexer of buffer card is connectedvia a 2%pair cable to the MDF (female amphenol connector at cag.e end), ‘\ -6-
SET-30 uses 4-pair wiring (using RI-45 connector) .CUTIVE St- .First pair (pin 4&S) T & R for 1st PBX 1~.Connected to PBX station circuit. Second pair (pins 3&6) Power (local or from buffer) Third pair (pins 2&7) Dot used.Fourth pair (pins l&8) T & R for 2nd PRX 11~Connected to PBX station circuit.Second line Gouldnormally not be used in this configuration. .auratlon wle SET-306Stand-alone Executive IPBX I : I -A-:IILine I Line: INTERII1 :2:con :,-’ IISET-30E EXECUTIVE
.. DNF: R~~CUTIVE/SX.EWARY COMBIWELQN ..ecutive Statran First pair (pins 4&S).T & R for 1st PBX laConnected toPBXstationcircuitand crossconnected to first pair -(pins 4&S) of secretary station. Second pair (pins 3&6)Power (local or from buffer) Third pair (pins 2&7)Uterca- crossconnected tothird ~t;~io~plns2&7) ofsecretary Fourth pair (pins l&8).T & R ior 2nd PRX 1~(optional). Connected toPBX stationcircuit. Crossconnected to four‘th pair (pins l&8) of secretary station,unless it is a private line. Note:In the configuration above, if both PBX station circuits are crossconnected between the executivestationand secretary station asshown,the first extension number will appear on the first button of both instruments, and the second extension number on the second button of both instruments. To have the extension numbers on one of the two instru- ments reversed, pair 1 at that station is crossconnected to pair. 4 of the other station,and pair 4 atthat /’ ‘\ station iscrossconnected topair l- of the other station. First pair (pins 4&S) Second pair (pins 3&6) Third pair (pins 2~7) Fourth pair (pins l&8) T 6 R for toPBX vt PBX 1~Connected stationcircuitand crossconneeted to first pair (pins 4&5) of executive station. Power (local or from buffer) tercogl crossconnectedto third pair(pins2&7)ofexecutive station..T C R for 2nd PBX lim(optional). Connected to PBX station circuit. Crossconnected to fourth pair (pins l&8) of executive station,unless it is a private line. -8-
One Private Secretary Serving One Executive with Two Common Lines and Dedicated IntercomPBX - I I I I I III III II- II I I eILine ILine IInterI corn III f lI ISET-30EI---SET 30-E III PRIVATE SECRETARYEXECUTIVE . . -9-
I OR II WIRING Note:Different multiplexer cards are used for single and dual secretary applications.-\.i:!/ Each PBX station circuit to appear at aSECRETARY station and an EXECUTIVE station is wired to a line pair on the multiplexer and the particular line on the EXECUTIVEinstrument where it is to appear (pair 1 or 4 of the 4-pair modular connector). Each PBX station circuit to appear at a SECRETARY station and a conventional telephone (2500 set) is alsowired to a line pair on the multiplexerand the lineof theinstrument. (Conven- tional instruments merely forwardedto a secretary arecon- nected to the PBX only). A PBX station circuit appearing ata SECRETARY station only is wired to a line pair on the multiplexer only. A PBX stationcircuit appearing atan EXECUTIVE station only (never to be answered by a secretary) is wired to the par- ticular line on the EXECUTIVE instrument where it is to appear (pair 1 or 4 of the cl-pair modular connector). The INTERCOM pairs of all instruments are wired in parallel and in addition to pair 11of one of the multiplexer cards in the multiplexer group. The T&R pair (pair1 on the 4-pair modular connector) of SECRETARY % is wired to pair 9of one of the multiplexer cards in the multiplexer group. The T&R pair (pair1 on the 4-pair modular connector) of - SECRETARY II (if used) is wired to pair 10 of one of the multi- plexer cards in the multiplexer group. Power for each instrument (pair 2 of the 4-pair modular connec- tor) may be obtained locally, from the multiplexercard, or a power buffer card. -10-