Page 91

SATURN EPABX A30808-X5051-C120-1-6918 
Standard Station User Instructions Issue 1, December 1984 
9.06 SMDR Account Codes. Account codes are used with 
SMDR on preselected incoming and outgoing trunk calls. Two 
types of account codes are used: standard (or default) ac- 
count codes and special account codes. Default account 
codes are assigned to stations and trunks and are automati- 
cally activated when you originate or receive a Call over one 
of these groups. Special account codes must be entered...

Page 92

SATURN EPABX A30808-X5051-C120-l-5918 
Standard Station User Instructions Issue 1, December 1984 
Table 9.00 Feature Access Codes 
FEATURE CODE FEATURE CODE 
CALL FORWARDING FEATURES SPEED CALLING FEATURES 
Call Forwarding - All Calls 
To Activate ......................... 
ToCancel ......................... 
Call Forwarding - Busy Lines 
To Activate ......................... 
ToCancel ......................... 
Call Forwarding - No Answer 
To Activate ......................... 
ToCancel...

Page 93

SATURN EPABX 
A30808-X5051-C120-l-B918 
Standard Station User Instructions 
Issue 
1, December 1984 
Table 9.01 Feature Instruction Guide 
FEATURE 
CALL FORWARDING - FEATURES PROCEDURE 
Call Forwarding - All Calls 
- TO Forward all incoming calls: 
- To cancel forwarding: 
Call Forwarding - Busy Lines 
- To forward incoming calls when 
your telephone is busy: 
- To cancel forwarding: : fr 
Pick up handset (dial tone) - Dial Call Forwarding All Calls activation code - 
Dial forwarded-to extension number...

Page 94

SATURN EPABX 
Standard Station User Instructions A30808-X5051-C120-l-8918 
Issue 1, December 1984 
, 
Table 9.01 Feature Instruction Guide (Continued) 
FEATURE 
PROCEDURE 
CALL QUEUING FEATURES (Con?.) 
Outgoing Call Queuing - Callback 
- To establish an automatic callback 
Busy tone is heard after dialing trunk access code - Do not hang up (busy tone 
condition: changes to low tone) - Hang up - When three-burst ringing is heard, pick up 
handset (dial tone) - Complete dialing number. 
- To cancel an...

Page 95

SATURN EPABX 
Standard Station User Instructions A30808-X5051-C120-l-8918 
Issue 1, December 1984 
Table 9.01 Feature Instruction Guide (Continued) 
FEATURE 
HOLD FEATURES (Con?.) PROCEDURE 
Call Hold - Flip-Flop (Broker) 
- To hold a call and answer a 
waiting call: 
- To hold a call and originate 
another call: 
- To return to a held call: 
- To alternate between two calls: Momentarily depress hookswitch (recall dial tone) - Dial the Call Hold Flip-Flop 
access code - You may begin to talk....

Page 96

SATURN EPABX 
Standard Station User instructions A30808-X5051-C120-‘~-B918 
issue 1, December 1984 
Table 9.01 Feature instruction Guide (Continued) 
FEATURE 
ADDITIONAL FEATURES PROCEDURE 
Call Transfer 
- To transfer a call: Momentarily depress hookswitch (recall dial tone) - Dial destination number (ring- 
back tone) - When party answers, announce the transfer - Hang up. 
Call Tracing 
- To trace a call: Momentarily depress hookswitch (recall dial tone) - Dial Call Trace access code 
(confirmation...

Page 97

Siemens Practices 
Operation Series A30808-X5051-CllO-l-8919 
Issue 1, December 1984 
SATURN@ EPABX 
OCIE 
ATTENDANT CONSOLE 
DESCRIPTION AND 
OPERATING INSTRUCTIONS 
Issued by Office Systems Group . 
5500 Broken Sound Boulevard N.W. Boca Raton, Florida 33431 
l (305) 994-8100 l Telex: 515052 
Siemens Communication Systems, Inc.. Printed in U.S.A.  

Page 98

Siemens Practices 
Operation Series A30808-X5051-CllO-l-8919 
Issue 1, December 1984 
0 Siemens Communication Systems, Inc., 1982, 1984 
All rights reserved. 
This material is Proprietary to Siemens Communication Systems, Inc. Any unautho- 
rized reproduction, use or disclosure of this material, or any part thereof, is strictly 
prohibited. 
Siemens reserves the right to make changes in specifications at any time and 
without notice. The information furnished by Siemens in this material is believed 
to...

Page 99

SATURN EPABX A30808-X5051-E130-l-8931 
Traffic Metering And Analysis Issue 1, December 1984 
. TRUNK ACTIVITY AUDIT REPORT 
l 
TRUNK GROUP NUMBER 3 
TRK INC INC 
INC OUT 
OUT OUT FAIL 
GLARE 
NUM ATTEMPT 
ccs HTIA ATTEMPT 
ccs HTIA ATTEMPT ATTEMPT 
0 66 
91.1 
138 0 
1.9 
.*** 
0 0 
1 50 
65.6 
131 0 
1.0 
“ft. 
0 0 
2 30 
41.0 
136 0 
0.6 
60 
0 0 
3 12 
27.3 
227 0 
0.7 
70 
0 0 
4 4 
2.0 
50 0 
0.0 
0 
0 0 
t DATA RESOURCE USAGE (IN CCS) 
l 
MODM PL 1 USAGE 
6 
MODM 
PL 2 USAGE 
1 
MODM PL 1 QUEUE 
0...

Page 100

SATURN EPABX 
Attendant Console General Description and Operating Instructions 
CONTENTS 
SECTION PAGE SECTION PAGE 
1.00 INTRODUCTION ............................. _ 
. l-l 
1.01 Purpose of Practice .......................... 
l-l 
1.02 Purpose of Equipment ........................ 
l-l 
1.03 SIEMENS SATURN Practices .................. 
l-l 
2.00 GENERAL DESCRIPTION ...................... 
.2-l 
2.01 Operational Characteristics ................... 
.2-l 
2.02 Physical Characteristics....
Start reading Siemens Saturn Epabx Oc1e Dyad Digital Telephone User Instructions

Related Manuals for Siemens Saturn Epabx Oc1e Dyad Digital Telephone User Instructions

All Siemens manuals