HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-6Service Manual lan2de.c02 2.1.2 HXGM Introduction The HiPath HG 1500 board HXGM connects the Hicom 150 H OfficePro with the LAN environment. The board supports up to 16 B channels. The following board variants are available: HiPath HG 1500 HXGM Voice and Data (S30810-Q2930-X) HiPath HG 1500 HXGM Data only (S30810-Q2930-X100) HiPath HG 1500 HXGM2 Voice and Data 2nd LAN interface (S30810-Q2940-X000) HiPath HG 1500 HXGM2...
Page 22
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-7 For internal use onlyInstallation Interfaces/connectors ●X10: 6-pin shielded MiniDin socket for V.24 cable; see Section 2.1.2.1 ●The board is connected to the system via the backplane. An adapter for the back- plane (part number C39228-A7195-A10, US backplane: C39195-Z7404-A10) is used to connect the LAN with an RJ45 connector, see Figure 2-4 . Figure 2-3 HXGM interfaces (S30810-Q2930/Q2940-X/X100) HXGM/HXGM2 to BP V. 2 4 X10...
Page 23
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-8Service Manual lan2de.c02 The TT1/2 and RT1/2 signals are not necessary for data transmission. They repre- sent a signal termination of 100 ohms (known as a Bob Smith Termination) for the two unused wire pairs in a four-pair twisted-pair cable. Figure 2-4 Adapter for HXGM backplane Table 2-7 RJ45 socket assignment (HXGM) Pin Signal I/O Function 1 TDP O Transmit Data + 2 TDN O Transmit Data - 3 RDP I Receive Data + 4...
Page 24
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-9 For internal use onlyInstallation LAN adapter cable (U.S. only) Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500 slot. Both the adapter cable and the connector are shielded. Figure 2-5 LAN adapter cable (U.S. only) Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter SIPAC connec- torRJ45 socket...
Page 25
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-10Service Manual lan2de.c02 Table 2-9 Assignment of the CHAMP-RJ45 LAN adapter cable CHAMP con- nectorRJ45 socket Signal Ethernet 34 1 TDP LAN #2 35 2 TDN 36 4 TT1 37 5 TT2 38 3 RDP 39 6 RDN 40 7 RT1 41 8 RT2 42 1 TDP LAN #1 43 2 TDN 44 4 TT1 45 5 TT2 46 3 RDP 47 6 RDN 48 7 RT1 49 8 RT2 25, 50 Housing Shield Table 2-10 HXGM LED concept H1 - red H2 - green Meaning Flashing Off Board is included in Firmware, no valid SW on...
Page 26
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-11 For internal use onlyInstallation Note Direct Ethernet twisted-pair connection to HiPath HG 1500 The RJ45 cable must be crossed as follows: 2.1.2.1 HXGM V.24 interface The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin MiniDin socket on the front panel of the HXGM. The SIC performs level conversion from TTL signals (HXGM2) to V.24 (9-pin Sub-D socket). Depending on the SIC, the maximum...
Page 27
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-12Service Manual lan2de.c02 Note A SLIP connection is required for Assistant administration of Xpress @LAN/HG 1500. However, a SLIP connection is not possible for the Loader. 2.1.3 Interfaces to the LAN The physical configuration of the LAN interface is predefined by the IEEE 802 stan- dard. The interface conforms to international standards for electrical safety and elec- tromagnetic compatibility (EMC). The...
Page 28
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-13 For internal use onlyInstallation 2.2 Part numbers ID Part number OfficePoint OfficeCom OfficePro HXGM Data only -- -- S30810-Q2930-X100 HXGM Voice and Data -- -- S30810-Q2930-X HXGM2 Data only -- -- S30810-Q2940-X100 HXGM2 Voice and Data -- -- S30810-Q2940-X000 HXGS Data only S30810-Q2931-X100 S30810-Q2931-X100 -- HXGS Voice and Data S30810-Q2931-X S30810-Q2931-X -- HXGS2 Data only with 2nd LANS30810-Q2939-X100...
Page 29
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-14Service Manual lan2de.c02 2.3 HiPath HG 1500 installation 2.3.1 Installation requirements ●Free slot for boards ●Hicom 150 E Office as of SW Version 2.2/Hicom 150 HV 1.0 ●ISDN trunk connection ●LAN connection ●See also Ta b l e 2 - 1 and Ta b l e 2 - 5 ●A DSL port is necessary for the HXGS/HXGM board with 2nd LAN 2.3.2 Slot Special country variants are not provided for. Examples of maximum system config- urations:...
Page 30
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-15 For internal use onlyInstallation 2.3.3 Installation procedure Table 2-14 Installation procedure in the case of OfficePoint/Com This sequence must be observed in order to guarantee successful LAN board login. Note In the case of Hicom 150 E/H OfficePro, the board can be plugged and unplugged without disconnecting the power supply.Step Task 1. Remove the power plug. 2. Insert the board. 3. Insert the power plug.