HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-6Service Manual lan2de.c02 2.1.2 HXGM Introduction The HiPath HG 1500 board HXGM connects the Hicom 150 H OfficePro with the LAN environment. The board supports up to 16 B channels. The following board variants are available: HiPath HG 1500 HXGM Voice and Data (S30810-Q2930-X) HiPath HG 1500 HXGM Data only (S30810-Q2930-X100) HiPath HG 1500 HXGM2 Voice and Data 2nd LAN interface (S30810-Q2940-X000) HiPath HG 1500 HXGM2 Data only 2nd LAN interface (S30810-Q2940-X100) Board slot Table 2-5 HXGM application option/slot Possible application Boards Slot OfficeProHicom 150 E as of V 2.2 P30370-P720-A680-* Hicom 150 H as of V 1.0 P30370-P800-A680-* Hicom 150 H as of V 1.2 P30370-P820-A680-*3 * All slots, except 2 * = Several boards may be operated in parallel Table 2-6 HXGM hardware variants System type Services DSPs Board ID OfficePro Data only 0 HXGM OfficePro Voice/Data 8 HXGM OfficePro Data only (2nd LAN) 0 HXGM2 OfficePro Voice/Data (2nd LAN)8 HXGM2 2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal Processor).
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-7 For internal use onlyInstallation Interfaces/connectors ●X10: 6-pin shielded MiniDin socket for V.24 cable; see Section 2.1.2.1 ●The board is connected to the system via the backplane. An adapter for the back- plane (part number C39228-A7195-A10, US backplane: C39195-Z7404-A10) is used to connect the LAN with an RJ45 connector, see Figure 2-4 . Figure 2-3 HXGM interfaces (S30810-Q2930/Q2940-X/X100) HXGM/HXGM2 to BP V. 2 4 X10 Backplane LAN 2* X8 LAN 1 X9 LED H2 (green) LED H1 (red) *) LAN 2 - for HXGM board with 2nd LAN interface only Adapter connection
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-8Service Manual lan2de.c02 The TT1/2 and RT1/2 signals are not necessary for data transmission. They repre- sent a signal termination of 100 ohms (known as a Bob Smith Termination) for the two unused wire pairs in a four-pair twisted-pair cable. Figure 2-4 Adapter for HXGM backplane Table 2-7 RJ45 socket assignment (HXGM) Pin Signal I/O Function 1 TDP O Transmit Data + 2 TDN O Transmit Data - 3 RDP I Receive Data + 4 (TT1) I Transmit Termination 1 5 (TT2) I Transmit Termination 2 6 RDN I Receive Data - 7 (RT1) I Receive Termination 1 8 (RT2) I Receive Termination 2 RJ45 socket 1SU-SIPAC connector Metal housing
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-9 For internal use onlyInstallation LAN adapter cable (U.S. only) Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500 slot. Both the adapter cable and the connector are shielded. Figure 2-5 LAN adapter cable (U.S. only) Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter SIPAC connec- torRJ45 socket Signal B1 1 TDP C2 2 TDN B3 4 TT1 C4 5 TT2 B5 3 RDP C6 6 RDN B7 7 RT1 C8 8 RT2 10/100 Base-T 10 Base-T female male
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-10Service Manual lan2de.c02 Table 2-9 Assignment of the CHAMP-RJ45 LAN adapter cable CHAMP con- nectorRJ45 socket Signal Ethernet 34 1 TDP LAN #2 35 2 TDN 36 4 TT1 37 5 TT2 38 3 RDP 39 6 RDN 40 7 RT1 41 8 RT2 42 1 TDP LAN #1 43 2 TDN 44 4 TT1 45 5 TT2 46 3 RDP 47 6 RDN 48 7 RT1 49 8 RT2 25, 50 Housing Shield Table 2-10 HXGM LED concept H1 - red H2 - green Meaning Flashing Off Board is included in Firmware, no valid SW on board, therefore V.24 charge mode On Off Board is included in Firmware, e.g. following reset, re- boot On -> Off Off Board at SW start, reboot Off Off -> On Board in idle status following reboot (call number of logon router) Off On At least one B channel occupied On On Approx. 20 s long: Board ready to activate reset (e.g. fol- lowing APS transfer or a FATAL error), waiting for Hicom reset
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-11 For internal use onlyInstallation Note Direct Ethernet twisted-pair connection to HiPath HG 1500 The RJ45 cable must be crossed as follows: 2.1.2.1 HXGM V.24 interface The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin MiniDin socket on the front panel of the HXGM. The SIC performs level conversion from TTL signals (HXGM2) to V.24 (9-pin Sub-D socket). Depending on the SIC, the maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchro- nous transmission only is supported. The interface is used for administration purposes. It can be used for software updates or board configuration. It can also be used for software debugging. Table 2-11 Contact assignment of the HXGM LAN interfaces X9 (LAN1) 10/100 Base-TX8 (LAN 2) 10 Base-TFunction 1 1 Transmit: + wire 2 2 Transmit: - wire 3 3 Receive: + wire 6 6 Receive: - wire 4+5+7+8 4+5+7+8 not used 1 32 63 16 2 Table 2-12 V.24 socket assignment (HXGM2) Pin Signal I/O Function 1GND 2 TXD O Transmit Data 3 CTS I Clear to Send 4 RXD I Receive Data 5 RTS O Request to Send 6+5V
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-12Service Manual lan2de.c02 Note A SLIP connection is required for Assistant administration of Xpress @LAN/HG 1500. However, a SLIP connection is not possible for the Loader. 2.1.3 Interfaces to the LAN The physical configuration of the LAN interface is predefined by the IEEE 802 stan- dard. The interface conforms to international standards for electrical safety and elec- tromagnetic compatibility (EMC). The electrically isolated coupling of the board at the LAN is performed by the send and receive transmitter. The maximum transmission speed of this baseband transmission technology is 100 MBit/s; the Manchester signaling code is used. The HiPath HG 1500 boards HXGS and HXGM are provided with a 10/100MB Au- tosense LAN port. The HiPath HG 1500 boards HXGS2 and HXGM2 with a 2nd LAN interface are also provided with a 10 BT LAN port, for example for routing via DSL.(7) GND Table 2-12 V.24 socket assignment (HXGM2) Pin Signal I/O Function
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-13 For internal use onlyInstallation 2.2 Part numbers ID Part number OfficePoint OfficeCom OfficePro HXGM Data only -- -- S30810-Q2930-X100 HXGM Voice and Data -- -- S30810-Q2930-X HXGM2 Data only -- -- S30810-Q2940-X100 HXGM2 Voice and Data -- -- S30810-Q2940-X000 HXGS Data only S30810-Q2931-X100 S30810-Q2931-X100 -- HXGS Voice and Data S30810-Q2931-X S30810-Q2931-X -- HXGS2 Data only with 2nd LANS30810-Q2939-X100 S30810-Q2939-X100 -- HXGS2 Voice and Data with 2nd LANS30810-Q2939-X000 S30810-Q2939-X000 -- Assistant Xpress @LAN HG 1500P30300-P1562-A1 P30300-P1562-A1 P30300-P1562-A1 Loader P30300-P1509-* P30300-P1509-* P30300-P1509-* CSTA converter P30300-P1530-A1 P30300-P1530-A1 P30300-P1530-A1 vCAPI (SW) P30300-P1561-A1 P30300-P1561-A1 P30300-P1561-A1 CTI TAPI 1P (4 clients) P30152-P1091-A1 P30152-P1091-A1 P30152-P1091-A1 CTI TAPI 3P V2 (30 users) F50035-E302-X11 F50035-E302-X11 F50035-E302-X11 CTI TAPI 3P V2 (80 users) F50035-E302-X12 F50035-E302-X12 F50035-E302-X12 CTI TAPI 3P V2 (250 users) F50035-E302-X13 F50035-E302-X13 F50035-E302-X13 Hicom client (kit for 4 clients) F50035-E4-X5 F50035-E4-X5 F50035-E4-X5 Telematic Fritz SW (4 clients)P30152-B6-A1 P30152-B6-A1 P30152-B6-A1 Smartset 2000 for ISDN (SW) P30152-B1-A10 P30152-B1-A10 P30152-B1-A10 Adapter (international) Adapter (USA)-- ---- --C39228-A7195-A10 C39195-Z7404-A10 LAN adapter cable (U.S. only) with female connectorC39195-Z7406-A2-1- 7425 LAN adapter cable (U.S. only) with male connectorC39195-Z7407-A2-1- 7425 Ferrite (kit) L30460-X1358-X -- -- V.24 cable S30122-X5468-X3 S30122-X5468-X3 S30122-X5468-X3
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-14Service Manual lan2de.c02 2.3 HiPath HG 1500 installation 2.3.1 Installation requirements ●Free slot for boards ●Hicom 150 E Office as of SW Version 2.2/Hicom 150 HV 1.0 ●ISDN trunk connection ●LAN connection ●See also Ta b l e 2 - 1 and Ta b l e 2 - 5 ●A DSL port is necessary for the HXGS/HXGM board with 2nd LAN 2.3.2 Slot Special country variants are not provided for. Examples of maximum system config- urations: Table 2-13 Slots Maximum system configurations for Hicom 150 E OfficePro are contained in the Hi- com 150 E Office/Hicom 150 H Service Manual.System Slot Configuration Trunk Station OfficePoint 2 SLA 4/8/16 SLU8 STLS 2/4 TLA 2/4/8 HiPath HG 150016 ports ISDN So MSI lines8 Upo/E + 16 from OfficeCom 6 SLA 4/8/16 SLU8 STLS 2/4 TLA 2/4/8 TS 2 HiPath HG 150030 ports ISDN S2m ISDN So MSI lines24 Upo/E + 48 from
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-15 For internal use onlyInstallation 2.3.3 Installation procedure Table 2-14 Installation procedure in the case of OfficePoint/Com This sequence must be observed in order to guarantee successful LAN board login. Note In the case of Hicom 150 E/H OfficePro, the board can be plugged and unplugged without disconnecting the power supply.Step Task 1. Remove the power plug. 2. Insert the board. 3. Insert the power plug.