    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-6Service Manual lan2de.c02
    2.1.2 HXGM
    Introduction
    The HiPath HG 1500 board HXGM connects the Hicom 150 H OfficePro with the LAN 
    environment. The board supports up to 16 B channels.
    The following board variants are available:
    HiPath HG 1500 HXGM Voice and Data (S30810-Q2930-X)
    HiPath HG 1500 HXGM Data only (S30810-Q2930-X100)
    HiPath HG 1500 HXGM2 Voice and Data 2nd LAN interface (S30810-Q2940-X000) 
    HiPath HG 1500 HXGM2 Data only 2nd LAN interface (S30810-Q2940-X100)
    Board slot
    Table 2-5 HXGM application option/slot
    Possible application Boards Slot
    OfficeProHicom 150 E as of V 2.2
    P30370-P720-A680-*
    Hicom 150 H as of V 1.0
    P30370-P800-A680-*
    Hicom 150 H as of V 1.2
    P30370-P820-A680-*3 * All slots, except 2
    * = Several boards may be operated in parallel
    Table 2-6 HXGM hardware variants 
    System type Services DSPs Board ID
    OfficePro Data only 0 HXGM
    OfficePro Voice/Data 8 HXGM
    OfficePro Data only (2nd LAN) 0 HXGM2
    OfficePro Voice/Data (2nd 
    LAN)8 HXGM2
    2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal 
    Processor). 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-7
    For internal use onlyInstallation
    Interfaces/connectors
    ●X10: 6-pin shielded MiniDin socket for V.24 cable; see Section 2.1.2.1
    ●The board is connected to the system via the backplane. An adapter for the back-
    plane (part number C39228-A7195-A10, US backplane: C39195-Z7404-A10) is 
    used to connect the LAN with an RJ45 connector, see Figure 2-4
    .
    Figure 2-3 HXGM interfaces (S30810-Q2930/Q2940-X/X100)
     HXGM/HXGM2
    to
    BP
    V. 2 4 X10
    Backplane
    LAN 2*
    X8
    LAN 1
    X9
    LED H2 (green)
    LED H1 (red)
    *) LAN 2 - for HXGM board with 2nd LAN interface only
    Adapter
    connection 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-8Service Manual lan2de.c02
    The TT1/2 and RT1/2 signals are not necessary for data transmission. They repre-
    sent a signal termination of 100 ohms (known as a Bob Smith Termination) for the two 
    unused wire pairs in a four-pair twisted-pair cable. Figure 2-4 Adapter for HXGM backplane
    Table 2-7 RJ45 socket assignment (HXGM)
    Pin Signal I/O Function
    1 TDP O Transmit Data +
    2 TDN O Transmit Data -
    3 RDP I Receive Data +
    4 (TT1) I Transmit Termination 1
    5 (TT2) I Transmit Termination 2
    6 RDN I Receive Data -
    7 (RT1) I Receive Termination 1
    8 (RT2) I Receive Termination 2
    RJ45 socket
    1SU-SIPAC connector Metal housing 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-9
    For internal use onlyInstallation
    LAN adapter cable (U.S. only)
    Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is 
    connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500 
    slot. Both the adapter cable and the connector are shielded.
    Figure 2-5 LAN adapter cable (U.S. only) Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter
    SIPAC connec-
    torRJ45 socket Signal
    B1 1 TDP
    C2 2 TDN
    B3 4 TT1
    C4 5 TT2
    B5 3 RDP
    C6 6 RDN
    B7 7 RT1
    C8 8 RT2
    10/100 Base-T
    10 Base-T
    female
    male 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-10Service Manual lan2de.c02
    Table 2-9 Assignment of the CHAMP-RJ45 LAN adapter cable
    CHAMP con-
    nectorRJ45 socket Signal Ethernet
    34 1 TDP LAN #2
    35 2 TDN
    36 4 TT1
    37 5 TT2
    38 3 RDP
    39 6 RDN
    40 7 RT1
    41 8 RT2
    42 1 TDP LAN #1
    43 2 TDN
    44 4 TT1
    45 5 TT2
    46 3 RDP
    47 6 RDN
    48 7 RT1
    49 8 RT2
    25, 50 Housing Shield
    Table 2-10 HXGM LED concept
    H1 - red H2 - green Meaning
    Flashing Off Board is included in Firmware, no valid SW on board, 
    therefore V.24 charge mode
    On Off Board is included in Firmware, e.g. following reset, re-
    boot
    On -> Off Off Board at SW start, reboot
    Off Off -> On Board in idle status following reboot (call number of 
    logon router) 
    Off On At least one B channel occupied
    On On Approx. 20 s long: Board ready to activate reset (e.g. fol-
    lowing APS transfer or a FATAL error), waiting for Hicom 
    reset 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-11
    For internal use onlyInstallation
    Note
    Direct Ethernet twisted-pair connection to HiPath HG 1500 
    The RJ45 cable must be crossed as follows:
    2.1.2.1 HXGM V.24 interface 
    The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin 
    MiniDin socket on the front panel of the HXGM. The SIC performs level conversion 
    from TTL signals (HXGM2) to V.24 (9-pin Sub-D socket). Depending on the SIC, the 
    maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchro-
    nous transmission only is supported. 
    The interface is used for administration purposes. It can be used for software updates 
    or board configuration. It can also be used for software debugging. Table 2-11 Contact assignment of the HXGM LAN interfaces
    X9 (LAN1)
    10/100 Base-TX8 (LAN 2)
    10 Base-TFunction
    1 1 Transmit: + wire
    2 2 Transmit: - wire
    3 3 Receive: + wire
    6 6 Receive: - wire
    4+5+7+8 4+5+7+8 not used
    1  32  63  16  2
    Table 2-12 V.24 socket assignment (HXGM2)
    Pin Signal I/O Function
    1GND
    2 TXD O Transmit Data
    3 CTS I Clear to Send
    4 RXD I Receive Data
    5 RTS O Request to Send
    6+5V 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-12Service Manual lan2de.c02
    Note
    A SLIP connection is required for Assistant administration of Xpress @LAN/HG 1500. 
    However, a SLIP connection is not possible for the Loader.
    2.1.3 Interfaces to the LAN
    The physical configuration of the LAN interface is predefined by the IEEE 802 stan-
    dard. The interface conforms to international standards for electrical safety and elec-
    tromagnetic compatibility (EMC). The electrically isolated coupling of the board at the 
    LAN is performed by the send and receive transmitter. The maximum transmission 
    speed of this baseband transmission technology is 100 MBit/s; the Manchester 
    signaling code is used.
    The HiPath HG 1500 boards HXGS and HXGM are provided with a 10/100MB Au-
    tosense LAN port.
    The HiPath HG 1500 boards HXGS2 and HXGM2 with a 2nd LAN interface are also 
    provided with a 10 BT LAN port, for example for routing via DSL.(7) GND Table 2-12 V.24 socket assignment (HXGM2)
    Pin Signal I/O Function 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-13
    For internal use onlyInstallation
    2.2 Part numbers
    ID Part number
    OfficePoint OfficeCom OfficePro
    HXGM Data only  -- -- S30810-Q2930-X100
    HXGM Voice and Data  -- -- S30810-Q2930-X
    HXGM2 Data only -- -- S30810-Q2940-X100
    HXGM2 Voice and Data  -- -- S30810-Q2940-X000
    HXGS Data only  S30810-Q2931-X100 S30810-Q2931-X100 --
    HXGS Voice and Data  S30810-Q2931-X S30810-Q2931-X --
    HXGS2 Data only with 2nd 
    LANS30810-Q2939-X100 S30810-Q2939-X100 --
    HXGS2 Voice and Data 
    with 2nd LANS30810-Q2939-X000 S30810-Q2939-X000 --
    Assistant Xpress @LAN
    HG 1500P30300-P1562-A1 P30300-P1562-A1 P30300-P1562-A1
    Loader P30300-P1509-* P30300-P1509-* P30300-P1509-*
    CSTA converter P30300-P1530-A1 P30300-P1530-A1 P30300-P1530-A1
    vCAPI (SW) P30300-P1561-A1 P30300-P1561-A1 P30300-P1561-A1
    CTI TAPI 1P (4 clients) P30152-P1091-A1 P30152-P1091-A1 P30152-P1091-A1
    CTI TAPI 3P V2 (30 users) F50035-E302-X11 F50035-E302-X11 F50035-E302-X11
    CTI TAPI 3P V2 (80 users) F50035-E302-X12 F50035-E302-X12 F50035-E302-X12
    CTI TAPI 3P V2 (250 users) F50035-E302-X13 F50035-E302-X13 F50035-E302-X13
    Hicom client (kit for 4 clients) F50035-E4-X5 F50035-E4-X5 F50035-E4-X5
    Telematic Fritz SW (4 clients)P30152-B6-A1 P30152-B6-A1 P30152-B6-A1
    Smartset 2000 for ISDN (SW) P30152-B1-A10 P30152-B1-A10 P30152-B1-A10
    Adapter (international)
    Adapter (USA)--
    ----
    --C39228-A7195-A10
    C39195-Z7404-A10
    LAN adapter cable (U.S. only) 
    with female connectorC39195-Z7406-A2-1-
    7425
    LAN adapter cable (U.S. only)
    with male connectorC39195-Z7407-A2-1-
    7425
    Ferrite (kit) L30460-X1358-X -- --
    V.24 cable S30122-X5468-X3 S30122-X5468-X3 S30122-X5468-X3 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-14Service Manual lan2de.c02
    2.3 HiPath HG 1500 installation
    2.3.1 Installation requirements
    ●Free slot for boards
    ●Hicom 150 E Office as of SW Version 2.2/Hicom 150 HV 1.0
    ●ISDN trunk connection
    ●LAN connection
    ●See also Ta b l e 2 - 1 and Ta b l e 2 - 5
    ●A DSL port is necessary for the HXGS/HXGM board with 2nd LAN
    2.3.2 Slot
    Special country variants are not provided for. Examples of maximum system config-
    urations:
    Table 2-13 Slots
    Maximum system configurations for Hicom 150 E OfficePro are contained in the Hi-
    com 150 E Office/Hicom 150 H Service Manual.System Slot Configuration Trunk Station
    OfficePoint 2 SLA 4/8/16
    SLU8
    STLS 2/4
    TLA 2/4/8
    HiPath HG 150016 ports ISDN So 
    MSI lines8 Upo/E + 16 from
    OfficeCom 6 SLA 4/8/16
    SLU8
    STLS 2/4
    TLA 2/4/8
    TS 2
    HiPath HG 150030 ports ISDN 
    S2m ISDN So
    MSI lines24 Upo/E + 48 
    from 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-15
    For internal use onlyInstallation
    2.3.3 Installation procedure
    Table 2-14 Installation procedure in the case of OfficePoint/Com
    This sequence must be observed in order to guarantee successful LAN board login.
    Note
    In the case of Hicom 150 E/H OfficePro, the board can be plugged and unplugged 
    without disconnecting the power supply.Step Task
    1. Remove the power plug.
    2. Insert the board.
    3. Insert the power plug. 
    						
    All Siemens manuals Comments (0)