    							IntroductionFor internal use only
     A31003-K5020-S100-6-7620
    1-2Service Manual lan2de.c01
    ●vCAPI for client PCs including fax services and CTI,
    ●SNMP (e.g. statistics and error signaling),
    ●Routing via the xDSL network (for HXGS with 2nd LAN interface only).
    Interfaces:
    ●10/100BT Autosense Ethernet twisted-pair,
    ●10BT Ethernet (for HXGS with 2nd LAN interface only) configurable with PPPoE,
    ●Up to 16 B channels,
    ●SLIP access (serial line interface) for initial startup, incl. cable (reference no. 
    S30122-X5468-X3).
    1.1.1 Prerequisite
    For this application, TCP/IP is implemented as the transport protocol and Win95/98/
    NT 4.0 or Windows 2000 as the client operating system. For the routing functionality, 
    the IP/IPX protocols are transferred transparently, independent of the operating sys-
    tem. Call numbers are allocated in HiPath HG 1500 via TCP/IP Address > Call Num-
    ber (max. 100 call numbers for vCAPI and max. 48 stations for voice applications). 
    The assignment of several call numbers to one TCP/IP address may be necessary if 
    several services are to be configured (voice, fax, file transfer, etc.).
    1.2 Short description
    HiPath HG 1500 is an expansion card for Hicom 150 E Office/Hicom 150 H Point/
    Com/Pro. It is used to connect a local LAN to Hicom systems and to link external 
    LANs via the system’s ISDN interface. Telematics and CTI functions are also support-
    ed. 
    The connection to the local LAN is set up via an Ethernet twisted-pair interface 
    (RJ45 connector); see Figure 2-1
     and Figure 2-4.
    In the case of OfficePoint and Com, the connection to the system is set up via a 50-
    pin edge connector of an expansion slot. The connection to the LAN is set up via an 
    RJ45 connector on the HiPath HG 1500 board. 
    In the case of OfficePro, the board is connected to the system via the backplane. An 
    adapter for the backplane (part number C39228-A7195-A10, US backplane: C39195-
    Z7404-A10) is used to connect the LAN with an RJ45 connector. 
    V.24 interface
    For loading and administration purposes (SLIP access), each system is provided with 
    an individual V.24 interface (cable reference no. S30122-X5468-X3). In both sys-
    tems, the V.24 connector for SLIP access is located on the board. 
    						
    							lan2de.c01
    A31003-K5020-S100-6-7620
    Service Manual
    1-3
    For internal use onlyIntroduction
    1.3 Service information
    The unique worldwide Ethernet address (MAC address) is a factory default and can-
    not be modified.
    Card recognition is performed automatically in Hicom 150 E Office/Hicom 150 H, 
    Point/Com/Pro. HiPath HG 1500 is installed as an individual board type in Hicom 150 
    E Office/Hicom 150 H, Point/Com/Pro. 
    The following items can be administered in Hicom:
    ●S0 station
    ●Xpress clients
    ●IP network lines
    ●numbering scheme
    ●associated dialing
    ●answer group (PC telephone)
    ●call forwarding (PC to fax)
    ●suppression of incoming 0
    ●CSTA interface
    Details on the initial startup and on accessing the board can be found in the HiPath 
    HG 1500 Administration Manual.
    A separate tool (Assistant Xpress @LAN/HG 1500) that can also be used by the cus-
    tomer or the LAN administrator is provided for entering and modifying data, e.g. the 
    IP address of the customer LAN or ISDN numbers assigned to a communication part-
    ner. The data is permanently stored in HiPath HG 1500. HiPath HG 1500 Assistant 
    also facilitates the storage of a corresponding configuration file. This can then be re-
    trieved if a board needs replacing. The tool also provides a facility for querying the 
    software version. Access to HiPath HG 1500 administration is password-protected. 
    This password can be changed; however, the Hicom password concept applies; see 
    Ta b l e 1 - 1
    .
    Note that only the user and Hicom passwords are allowed.
    A simple functional test can be performed directly at the customer PC or on a service 
    PC with a network card, vCAPI driver and a CAPI-based application.
    APS transfer for the HiPath HG 1500 board is usually performed via the LAN using 
    the Assistant or, in exceptional circumstances, via the V.24 interface using the Load-
    er.
    Cable with reference number S30122-X5468-X3 (see also Section 2.1.1.1
     or 
    Section 2.1.2.1
    ) is used for the V.24 port of the HiPath HG 1500 board. 
    						
    							IntroductionFor internal use only
     A31003-K5020-S100-6-7620
    1-4Service Manual lan2de.c01
    1.4 Hicom password concept
    Further information is contained in the Hicom 150 E Office Rel. 2.0-3.0 Service Man-
    ual or Hicom 150 H V1.0. Table 1-1 Starting Hicom system administration (Service)
    Step Input Explanation
    1. *95 Start system administration
    2. 31994 User: 31994 (default)
    3. 31994 Password: 31994 (default)
    or
    1.
    ✓Change user and/or password
    2. Confirm user and/or password 
    						
    							lan2de.c01
    A31003-K5020-S100-6-7620
    Service Manual
    1-5
    For internal use onlyIntroduction
    1.5 Functional environment of HiPath HG 1500
    1.5.1 Parallel operation
    Hicom 150 E Office/Hicom 150 HCom/Pro systems support parallel operation of sev-
    eral HiPath HG 1500 boards. 
    1.5.2 Interworking with features 
    1.5.2.1 Least Cost Routing (LCR)
    In Hicom systems, LCR technology enables the most cost-effective connections via 
    ISDN.
    1.5.2.2 Trunk access/toll restriction
    Trunk access is configured in Hicom 150 H/HiPath HG 1500Point/Com/Pro for call 
    numbers used by Hicom 150 E Office. Hicom toll restriction for outgoing seizure is 
    performed based on this trunk access in the same way as for outgoing calls.
    1.5.3 Gatekeeper
    The following functions are performed by a gatekeeper in an H.323 network:
    ●Registering H.323 end units,
    ●Managing rights and services,
    ●Converting station numbers to logical names or IP addresses and vice versa,
    ●Managing bandwidth on the network side,
    ●Registering gateways,
    ●Registering multiconference units,
    ●Can be linked to neighboring gatekeepers (zones).
    The setup procedure for gatekeeper operations is described in Section 3.1.3
    . System type  Number of boards
    OfficePoint 1
    OfficeCom 2
    OfficePro 3 
    						
    							IntroductionFor internal use only
     A31003-K5020-S100-6-7620
    1-6Service Manual lan2de.c01
    >
    If no gateways or multiconference units are being used, IP telephony can also be 
    implemented in H.323 networks without gatekeepers. Note, however, that the con-
    nection can only be set up via the IP address in this case, so no authorizations and 
    bandwidth control are possible.
    In general, the following applies: without gatekeepers, many features may be dis-
    abled or subject to severe restrictions. 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-1
    For internal use onlyInstallation
    2 Installation
    2.1 HiPath HG 1500 boards 
    HG 1500 supports two function groups: the “voice functionality” with the features 
    H.323 GW and TFA and the “data functionality” with the features VCAPI and RAS. A 
    board variant (X100) that only supports the data functionality (Data only) is available; 
    this board is not equipped with signal processors and the associated logic.
    2.1.1 HXGS
    Introduction
    The HiPath HG 1500 board HXGS connects Hicom 150 E Office/Hicom 150 H Office-
    Com/OfficePoint with the LAN environment. The board supports up to 16 B channels.
    The following board variants are available:
    HiPath HG 1500 HXGS Voice and Data (S30810-Q2931-X)
    HiPath HG 1500 HXGS Data only (S30810-Q2931-X100)
    HiPath HG 1500 HXGS2 Voice and Data 2nd LAN interface (S30810-Q2939-X000)
    HiPath HG 1500 HXGS2 Data only 2nd LAN interface (S30810-Q2939-X100)
    Board slot
    Table 2-1 HXGS application option/slot
    Possible application Boards Slot
    OfficePointHicom 150 E as of V 2.2
     
    P30370-P722-A680-*
    Hicom 150 H as of V 1.0
    P30370-P802-A680-*
    Hicom 150 H as of V 1.2
    P30370-P822-A680-*1 All slots
    OfficeCom
    Old HW
    CBFCHicom 150 E as of V 2.2 
    P30370-P723-A680-G1 2 * Slots 4 and 5 only
    OfficeCom
    New HW
    CBPCHicom 150 E as of V 2.2
     
    P30370-P721-A680-*
    Hicom 150 H as of V 1.0
    P30370-P801-A680-*
    Hicom 150 H as of V 1.2
    P30370-P821-A680-*2 * All slots 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-2Service Manual lan2de.c02
    Interfaces/connectors
    The LAN port is linked at the X3/X4 connectors. For connector assignment, see 
    Ta b l e 2 - 3
    .
    The board is equipped with a 50-pin edge connector to the system, two Western 
    sockets (8-pin, 10-pin shielded) to the LAN and a shielded MiniDin socket (6-pin) for 
    the V.24 interface:
    ●X1: 50-pin to the system
    ●X2: 6-pin shielded MiniDin socket for V.24 interface, see Section 2.1.1.1
    The following connection option is provided for connection to a LAN:
    ●X3: 8-pin Western socket for LAN 10/100 Base-T, RJ45 socket (twisted pair)
    for station
    ●X4: 8-pin Western socket for LAN 10 Base-T, RJ45 socket (twisted pair)
    for trunk connection (for HXGS2 board with 2nd LAN interface only
    ) * = 2 boards may be operated in parallel
    OfficeCom, old HW, CBFC: S30810-Q2950-X
    OfficeCom, new HW, CBPC: S30810-Q2932-A201
    Table 2-2 HXGS hardware variants 
    System type Services DSPs Board ID
    OfficeCom/Point Data only 0 HXGS
    OfficeCom/Point Voice/Data 4 HXGS
    OfficeCom/Point Data only (2nd LAN) 0 HXGS2
    OfficeCom/Point Voice/Data (2nd 
    LAN)4 HXGS2
    2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal 
    Processor). Table 2-1 HXGS application option/slot
    Possible application Boards Slot 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-3
    For internal use onlyInstallation
    A twisted-pair cable is used as the transmission medium for 10/100 Base-T and 10 
    Base-T. Figure 2-1 HXGS interfaces (S30810-Q2931-X/X100)
    Figure 2-2 HXGS2 interfaces with 2nd LAN (S30810-Q2939-X000/X100)
    LAN
    connec-
    tion
    to
    CUC/
    CUP
     HXGS
     
    V. 2 4 X2
    10/100 Base-T X350
    X1
    2
    LAN
    connec-
    tions
    to
    CUC/
    CUP
     HXGS2
     
    with 2nd LAN interface
    V. 2 4 X2
    10/100 Base-T (station) X350
    X1
    2
    10 Base-T (trunk) X4 
    						
    							HiPath HG 1500 boards Installation
    For internal use only
     A31003-K5020-S100-6-7620
    2-4Service Manual lan2de.c02
    The cable is connected to the HiPath HG 1500 HXGS/HXGS2 (OfficeCom and Offi-
    cePoint) via the 8-pin Western socket (X3) located on the MDF side of the circuit 
    board, see Figure 2-1
    , or X3 and X4, see Figure 2-2.
    Notes
    Direct Ethernet twisted-pair connection to HiPath HG 1500 
    The RJ45 cable must be crossed as follows:
    A ferrite kit must be installed on the LAN 1 and LAN 2 lines on the RJ45 cable.
    2.1.1.1 HXGS V.24 interface 
    The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin 
    MiniDin socket on the front panel of the HXGS. The SIC performs level conversion 
    from TTL signals (HXGS) to V.24 (9-pin Sub-D socket). Depending on the SIC, the 
    maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchro-
    nous transmission only is supported.
    The interface is used for administration purposes. It can be used for software updates 
    or board configuration. It can also be used for software debugging. Table 2-3 Contact assignment of the HXGS LAN interfaces
    X3
    10/100 Base-TX4
    10 Base-TFunction
    1 1 Transmit: + wire
    2 2 Transmit: - wire
    3 3 Receive: + wire
    6 6 Receive: - wire
    4+5+7+8 4+5+7+8 not used
    1  32  63  16  2 
    						
    							HiPath HG 1500 boards
    lan2de.c02
    A31003-K5020-S100-6-7620
    Service Manual
    2-5
    For internal use onlyInstallation
    Table 2-4 HXGS V.24 interface
    Pin Signal I/O Function
    1GND
    2 TXD O Transmit Data
    3 CTS I Clear to Send
    4 RXD I Receive Data
    5 RTS O Request to Send
    6+5V
    (7) GND 
    						
    All Siemens manuals Comments (0)