Page 11
IntroductionFor internal use only A31003-K5020-S100-6-7620 1-2Service Manual lan2de.c01 ●vCAPI for client PCs including fax services and CTI, ●SNMP (e.g. statistics and error signaling), ●Routing via the xDSL network (for HXGS with 2nd LAN interface only). Interfaces: ●10/100BT Autosense Ethernet twisted-pair, ●10BT Ethernet (for HXGS with 2nd LAN interface only) configurable with PPPoE, ●Up to 16 B channels, ●SLIP access (serial line interface) for initial startup, incl. cable (reference no....
Page 12
lan2de.c01 A31003-K5020-S100-6-7620 Service Manual 1-3 For internal use onlyIntroduction 1.3 Service information The unique worldwide Ethernet address (MAC address) is a factory default and can- not be modified. Card recognition is performed automatically in Hicom 150 E Office/Hicom 150 H, Point/Com/Pro. HiPath HG 1500 is installed as an individual board type in Hicom 150 E Office/Hicom 150 H, Point/Com/Pro. The following items can be administered in Hicom: ●S0 station ●Xpress clients ●IP network...
Page 13
IntroductionFor internal use only A31003-K5020-S100-6-7620 1-4Service Manual lan2de.c01 1.4 Hicom password concept Further information is contained in the Hicom 150 E Office Rel. 2.0-3.0 Service Man- ual or Hicom 150 H V1.0. Table 1-1 Starting Hicom system administration (Service) Step Input Explanation 1. *95 Start system administration 2. 31994 User: 31994 (default) 3. 31994 Password: 31994 (default) or 1. ✓Change user and/or password 2. Confirm user and/or password
Page 14
lan2de.c01 A31003-K5020-S100-6-7620 Service Manual 1-5 For internal use onlyIntroduction 1.5 Functional environment of HiPath HG 1500 1.5.1 Parallel operation Hicom 150 E Office/Hicom 150 HCom/Pro systems support parallel operation of sev- eral HiPath HG 1500 boards. 1.5.2 Interworking with features 1.5.2.1 Least Cost Routing (LCR) In Hicom systems, LCR technology enables the most cost-effective connections via ISDN. 1.5.2.2 Trunk access/toll restriction Trunk access is configured in Hicom 150...
Page 15
IntroductionFor internal use only A31003-K5020-S100-6-7620 1-6Service Manual lan2de.c01 > If no gateways or multiconference units are being used, IP telephony can also be implemented in H.323 networks without gatekeepers. Note, however, that the con- nection can only be set up via the IP address in this case, so no authorizations and bandwidth control are possible. In general, the following applies: without gatekeepers, many features may be dis- abled or subject to severe restrictions.
Page 16
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-1 For internal use onlyInstallation 2 Installation 2.1 HiPath HG 1500 boards HG 1500 supports two function groups: the “voice functionality” with the features H.323 GW and TFA and the “data functionality” with the features VCAPI and RAS. A board variant (X100) that only supports the data functionality (Data only) is available; this board is not equipped with signal processors and the associated logic. 2.1.1 HXGS Introduction...
Page 17
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-2Service Manual lan2de.c02 Interfaces/connectors The LAN port is linked at the X3/X4 connectors. For connector assignment, see Ta b l e 2 - 3 . The board is equipped with a 50-pin edge connector to the system, two Western sockets (8-pin, 10-pin shielded) to the LAN and a shielded MiniDin socket (6-pin) for the V.24 interface: ●X1: 50-pin to the system ●X2: 6-pin shielded MiniDin socket for V.24 interface, see Section...
Page 18
HiPath HG 1500 boards lan2de.c02 A31003-K5020-S100-6-7620 Service Manual 2-3 For internal use onlyInstallation A twisted-pair cable is used as the transmission medium for 10/100 Base-T and 10 Base-T. Figure 2-1 HXGS interfaces (S30810-Q2931-X/X100) Figure 2-2 HXGS2 interfaces with 2nd LAN (S30810-Q2939-X000/X100) LAN connec- tion to CUC/ CUP HXGS V. 2 4 X2 10/100 Base-T X350 X1 2 LAN connec- tions to CUC/ CUP HXGS2 with 2nd LAN interface V. 2 4 X2 10/100 Base-T (station) X350 X1 2 10 Base-T...
Page 19
HiPath HG 1500 boards Installation For internal use only A31003-K5020-S100-6-7620 2-4Service Manual lan2de.c02 The cable is connected to the HiPath HG 1500 HXGS/HXGS2 (OfficeCom and Offi- cePoint) via the 8-pin Western socket (X3) located on the MDF side of the circuit board, see Figure 2-1 , or X3 and X4, see Figure 2-2. Notes Direct Ethernet twisted-pair connection to HiPath HG 1500 The RJ45 cable must be crossed as follows: A ferrite kit must be installed on the LAN 1 and LAN 2 lines on the RJ45...