Page 11

EN-10
Express Defrost with 
Memory
*  Suppose you want to cook with memory 0, which was 
programmed for 10 minutes Express Defrost sequence, 
Single Digit Input/Auto Start ON.
Procedure
1  Place food in oven.
    Enter memory number.0
Midway through the defrosting cycle, the CHECK 
indicator will light in the display and an audible 
signal will be heard unless signal volume has been 
set to Mute. You may open the door, turn food over 
and shield any warm portions. Close the door.
MANUAL OPERATION
Time...

Page 12

EN-11
Procedure
4   Press the SELECT POWER pad.
  Enter power level for 2nd stage.
5  Press the SELECT TIME pad.
  Enter cooking time  for 3rd 
stage.
SELECT
POWER5
300
SELECT
TIME
6  Press the START pad.START
NOTES: 
1.  It is not necessary to press the SELECT POWER pad 
for 100% at the last stage in Multi Stage Cooking.
2.  If the Total Cooking Time is over the maximum time 
allowed, error message, EE9 will be displayed. Press 
the STOP/CLEAR pad to clear the error message pad 
and reduce Total Cooking...

Page 13

EN-12
PROGRAM & CUSTOMIZE
Custom Help
You can check your oven settings and customize your 
oven by changing Custom Help settings.
The CUSTOM HELP pad has 11 operations. 
  1. Selecting Memory Input Method
  2. Selecting Auto Start Operation
  3. Program Lock Setting
  4. Audible Signal Sound Volume Setting
  5. Cooking Completion Signal Setting  
 6. Memory Check
 7. Counter Check/Clear
  8. Air Intake Filter Counter
  9. Selecting Operation in case of Magnetron Failure
 10. Multiplication Factors for...

Page 14

EN-13
*  Suppose you want to set Program Lock ON.
x 2
Procedure
3  2
STOP
CLEAR
CUSTOM
HELP1  Press the CUSTOM HELP pad 
twice within 2 seconds.
2  Enter 3, 2 for Program Lock 
ON.
3  Press the START pad to
  save the setting.START
4  Press the STOP/CLEAR pad 
to exit from the Custom Help 
Function.
NOTE : If you select Program Lock OFF, the LOCK 
indicator in the display will disappear when you press 
the START pad.
Operation when Program Lock ON is set
KEY 
OperationCustom Help TitleWhen Program 
Lock...

Page 15

EN-14
 Procedure  Display
2  Enter memory number.
  (After entering the 
memory number, the 
memory setting of each 
content is shown for 
1.5 seconds at 0.3 second 
intervals until the STOP/
CLEAR pad is pressed.)
1
0  
After about 1 sec.CHECK
CHECK
CHECK
CHECK
CHECK
CHECK
STOP
CLEAR
3  Press the STOP/CLEAR pad       
to exit from the Custom Help 
Function.
CHECKNO.
CHECK
NOTES:
1. If 
CHECK  is displayed at step 2 the memory has not 
been programmed.
2. Multiple memories can be checked until the STOP/...

Page 16

EN-15
NOTES:
1. Only Dual Digit Input method can be used when 
inputting memory numbers in Counter Check/Clear.
2.  To clear total manual cooking usage, press the SELECT 
TIME pad in Step 2 instead of the number pad.
3. To clear total Express Defrost usage, press the 
EXPRESS DEFROST pad in Step 2 instead of the 
number pad.
4.  To clear total usage, skip Step 2.
8.  Air Intake Filter Counter
Use Custom Help Function for Air Intake Filter Counter 
to check total usage hours since the Air Intake Filter...

Page 17

EN-16
Air Filter Cycle
Air Filter Cycle can be changed from the factory setting 
of 100 hours to 001-999 hours
*  Suppose you want to set the cycle to 250 hours.
 Procedure  Display
2  Press the SELECT TIME pad.
3  Enter desired time.
  (Ex : Enter 2, 5, 0 for 250 
hours).  
1  Press the CUSTOM HELP 
pad twice within 2 seconds 
and enter 8, 2.
SELECT
TIME
x282CUSTOM
HELP
2 5 0 
After about 1 sec.
CHECK
4  Press the START pad to save settings.
START
STOP
CLEAR
5  Press the STOP/CLEAR pad to exit from the...

Page 18

EN-17
NOTES:
1. Only Dual Digit Input method can be used when 
inputting memory numbers in Multiplication Factor 
for Double/Triple Quantity.
2.  The multiplication factors can be set from 0.01 to 9.99  
for double quantity and  triple quantity.
3.  When you want to know the multiplication factor for 
triple quantity, press the DOUBLE/TRIPLE QUANTITY 
twice at step 1 after pressing the CUSTOM HELP pad 
twice.
4.  Multiplication Factors for Double/Triple Quantity can 
be checked or changed before pressing...

Page 19

EN-18
 Procedure  Display
  5  Press the SELECT TIME 
pad and enter desired 
multiplication for A2 at 
Stage 2.
    (Ex: Enter 1, 5 for 0.15.)SELECT
TIME
1
5
DEF.
DEF.
DEF.
  6  Press the SELECT TIME 
pad and enter desired 
time for B2 at Stage 2.
    (Ex: Press 2 for 
20 seconds.)SELECT
TIME
2
DEF.
DEF.
  8  Press the SELECT TIME 
pad and enter the pause 
timing.
    (Ex: Enter 7 for when 70% 
of total defrosting time 
has passed.)SELECT
TIME
7
DEF.
  7  Press the SELECT  
POWER pad and enter 
desired...

Page 20

EN-19
NOTES: 
1.  Press the SET MEMORY pad twice within 2 seconds.
2. If the cooking time is over the maximum time, the 
display will show error code EE9. To clear the error 
code, press the STOP/CLEAR pad and re-program. 
See Maximum Cooking Time on page EN-22.
3.  It is not necessary to press the SELECT POWER pad 
for 100% in Single Stage.

*  Suppose you want to set 1 minute at 70% with memory 
12.
1  Press the SET MEMORY pad 
twice within 2 sec.
2  Enter memory number.
NO.
NO.
2  2
3  Press the...
Start reading Sharp Rcd1200m Manual