Sharp Cv10ctxw Manual
Have a look at the manual Sharp Cv10ctxw Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CV10CTXB CV10CTXW CV10CTXS ENGLISH ESPA ÑOL PORTABLE TYPEROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL ACONDICIONADOR DE AIREPARA HABITACIÓN TIPO PORTÁTIL MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO
EN-1 ENGLISH Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. Declaration of Conformity SHARP ROOM AIR CONDITIONER CV10CTXB, CV10CTXW, CV10CTXSThis device complies with Part 18 of FCC rules. Responsible Party: SHARP ELECTRONICS CORPORATION.Sharp Plaza, Mahwah, New Jersey 07495-1163TEL: 1-800-BE-SHARP ENGLISH CONTENTS • FOR CUSTOMER ASSISTANCE .........................................................EN-2 • CONSUMER LIMITED WARRANTY ....................................................EN-3 • PRECAUTIONS ........................................................................\ ...........EN-4 • LOCATION ........................................................................\ ..................EN-7 • INCLUDED ........................................................................\ ..................EN-7 • PART NAMES ........................................................................\ ..............EN-8 • INSTALL WINDOW PANEL ..................................................................EN-12 • INSTALLATION AND REMOVAL OF EXHAUST HOSE ........................EN-16 USE FOR AIR CONDITIONER • COOL MODE ........................................................................\ ..............EN-18 • DRY (DEHUMIDIFICATION) MODE .....................................................EN-18 • FAN MODE ........................................................................\ ..................EN-18 • TO CHANGE AIR FLOW DIRECTION .................................................EN-18 • TIMER OPERATION ........................................................................\ ....EN-21 • SLEEP OPERATION ........................................................................\ ....EN-22 • MAINTENANCE ........................................................................\ ...........EN-23 • BEFORE CALLING FOR SERVICE ......................................................EN-25
EN-2 To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS THE INTERNET: www.sharpusa.com Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem. FOR CUSTOMER ASSISTANCE (the United States)
EN-3 ENGLISH TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT www.sharpusa.com SHARP ELECTRONICS CORPORATIONSharp Plaza, Mahwah, New Jersey 07495-1163 CONSUMER LIMITED WARRANTY FOR THE U.S. USERS SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the “Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below. This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse, abnormal service or handling, or which has\ been altered or modified in design or construction. In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof of purchase to the servicer. The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein, or to extend the duration of any warranties beyond the time period \ described herein on behalf of Sharp. The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shal\ l be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the a\ bove exclusion may not apply to you. THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. CV10CTXB, CV10CTXW, CV10CTXSPortable Air Conditioner. Be sure to have this information available when you need service for your Product. One (1) year parts and labor from date of purchase. The warranty period continues for a total of five (5) years from date of purchase for the Sealed Cooling System parts; labor and service are not provided free of change for this additional period. Appearance items of the Product, filters, or accessories, or any printed materials. Product which has been used for rental and/or commercial purposes. From a Sharp Authorized Servicer located in the United States. To find the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer will come to your home, and if it is necessary to remove the Product, the Servicer will reinstall it. Be sure to have Proof of Purchase available. CONSUMER LIMITED WARRANTY Your Product Model Number & Description: Warranty Period for this Product: Additional Item(s) Excluded From Warranty Coverage (If any): Where to Obtain Service: What to Do to Obtain Service:
EN-4 Points to keep in mind when using your unit. WARNINGS FOR USE • Install the unit in accordance with the installation instructions in the latter section of this manual. • Do not modify any part of this product. • Do not insert anything into any part of the unit. • Ensure the power supply used has an appropriate voltage rating. Only use a three-pin grounded electrical AC socket rated 125V, 60Hz, and 15 amps or more. Use of a power supply with an improper voltage rating can result in damage to the unit and possibly fire. • Always use a fuse with the proper amp rating. Do not, under any circumstances, use wire, pins or other objects in place of a proper fuse. • In the event of any abnormality with the unit (ex. a burning smell), turn it off imme-diately and disconnect the power supply. WARNING FOR POWER SUPPLY CORD • This unit uses a plug with a built-in fuse. Read the precautions on the plug before using the unit. • Always conduct a “Power Plug Check” before use to confirm the power plug func-tions normally. • This power plug must only be plugged into an appropriate wall socket. Do not use in conjunction with any extension cords. • Push the power plug securely into the socket and make sure it is not loose. • Do not pull, deform, or modify the power supply cord, or immerse it in water. Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock. • A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired. Replacement must be performed by manufacture's service agent in order to avoid a hazard. Radio or TV Interference If this room air conditioner should cause interference to radio or television reception, try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into an outlet on a circuit different from that to which the radio/TV receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. PRECAUTIONS
EN-5 ENGLISH USAGE CAUTIONS • Be sure to turn the unit off and disconnect the power supply cord before perform-ing any maintenance or cleaning. • Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage. • Drainage should be performed whenever moving the unit. If any water remains in the tank, it may spill out while being moved. • Remove the window panel in the event of particularly adverse weather. Extremely adverse weather may cause water to leak in through the openings. • To ensure proper drainage, the drainage hose must have no kinks or be on a differ-ent level during dehumidification mode. The drained water may spill out into the room. • The temperature around the drainage hose must not be below freezing point when used. Drained water may freeze inside the hose, causing water inside the unit to overflow into the room. • Do not block the exhaust air outlet with obstacles. Cooling performance may be reduced or stop completely. WARNING ABOUT GROUNDING • Improper use of the grounding plug can result in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, ground-ing reduces the risk of an electric shock by providing a less resistant conduit for the electric current. This appliance is equipped with a cord that has a grounding wire connected to a grounding plug. The plug must be plugged into a socket that is properly installed and grounded. • Do not under any circumstances cut or remove the round grounding pin from this plug. Consult a qualified electrician or service-man if the grounding instructions are not completely understood, or if in any doubt as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the electrical box is fully grounded. Grounding wire ScrewTab for grounding screw Grounded electri-cal box Grounding adapter Grounding pin Grounded electrical box 3-Pin socket 3-Pin plug
EN-6 PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the unit off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety. • In the event of a power failure during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the unit. If the power was off for less than three min-utes, be sure to wait at least three minutes before restarting the unit. If you restart the unit within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Any previous settings will be cancelled and the unit will return to its initial settings. • Low temperature operation: Is your unit freezing up? Freezing may occur when the unit is set close to 64°F in low ambient te\ mperature con-ditions, especially at night. In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing. • Dehumidification mode increases room temperature. The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit. • This unit blows the warm air generated by the unit outside the room via the ex-haust hose while in cool mode. Accordingly, the same amount of air as that is blown out will enter the room from outside through any openings into the room. • When cooling operation is performed at high humidity conditions, water tank in-side the unit may frequently become full. When water tank inside the unit is full, the unit stops operating Buzzer will sound 8 times, LED window show error code H8. In this case, perform drainage to drain out water within the unit. OPERATING CONDITIONS • The unit must be operated within the following temperature range. ModeRoom temperature Cool64°F - 95°F • A built-in safety device may cut off operation if the temperature exceeds these limits. ENERGY EFFICIENCY TIPS • Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode. • Keep the filter clean. Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your unit work harder and less efficiently. • Turn off unnecessary lights. Your unit must remove the heat produced by your lights or other heat-producing appli-ances. Turn off any lights or appliances that are not in use.
EN-7 ENGLISH MIN.12" (30cm) MIN.12" (30cm) MIN.12" (30cm) • The unit should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. • The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. • The unit must be placed within reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of the unit. • Allow at least 12" (30cm) of space from the wall for efficient air-conditioning. LOCATION INCLUDED SUGGESTED T OOLS FOR WINDOW P ANELINSTALLA TION 1. Screw driver (medium size Phillips) 2.Tape measure or ruler 3. Knife or scissors 4. Saw (Inthe event thatthewindow panelneeds tobe cut down insize because thewindow istoo narrow for direct installation.) Window Exhaust Adapter A ExhaustHoseExtension panel Drain hose g u l p r e b b u R p m a l C e s o H Battery (2) (AAA.1.5V) Window Exhaust Adapter Manual Remote control hook (2) Power cordScrew (8) Bracket Foam seal B (adhesive type) Foam seal A Insect guard net Rain guard (2) Window panel Adjustment panel Exhaust cover Hose clip (2)
EN-8 FrontRear 21 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 17 16 18 19 20 1 Control panel and display lamp2 Remote control signal receiver window3 Handle4 Remote controller box5 Air outlet6 Vertical louvers7 Horizontal louvers8 Wheel9 Air inlet10 Grill11 Air outlet12 Air inlet13 Power cord hook14 Power cord15 Window exhaust adapter (down)16 Rain guard17 Insect guard net18 Window exhaust adapter (up)19 Exhaust hose20 Joint21 Remote control STRUCTURE