Page 11

CONNECTIONS(VCC-4592P only)
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are
sold separately.1
Make the video signal connection between the camera and
the monitor or time lapse VCR.
2
Use a commercially available 12 V DC adaptor.
Connect an DC 12 V power source to the 12 V DC input terminal
on the back of the camera.
2A:
When using this unit, the supplied clamping core (A or B) must be
installed on the power cord and BNC cable, in order to...

Page 12

SETTINGSThe illustration shows the factory default settings for the switches in the camera setup section.
The camera settings are described on the assumption that a DC type auto iris lens is being used. If you are using a VIDEO type auto iris lens, be
sure to read the Note which is given. Furthermore, refer to the sticker on the inside of the cover for details on DIP switch positions.
Control name Position
1
Colour and Black/White level switch
(Normal: L/High sensitivity: H)L
2
High speed electronic...

Page 13

SETTINGS
High speed electronic shutter setting
Normally, the speed setting switches for the high speed electronic
shutter are all set to the down (OFF) position. This sets the electronic
shutter speed to 1/50 sec. The switches can be set as indicated in
table A to select one of the 8 speeds available.CAUTION:ÃWhen using the high speed electronic shutter, the switch 4 must
be set to the down (AI) position.ÃUsing the high speed electronic shutter indoors with low lighting,
will give darker pictures. In...

Page 14

SETTINGS
Backlight compensation setting
This camera has two different backlight
compensation functions: Normally backlight
compensation switch 6 (MULT) and 7 (CENT)
are set to the down (OFF) position. Change
the backlight compensation switch settings
depending on the conditions.ÃMULT mode:Use this position when applying backlight
compensation to the whole of the screen.ÃCENT mode:Use this position when applying backlight
compensation to only the central portion of the
screen.
Note:ÃIf switches 6 and 7...

Page 15

SETTINGS
White balance adjustment
Normally the switch 8 (WB) is set to the down (ATW: auto white
balance) position and the white balance is adjusted automatically. If a
manual white balance adjustment is necessary, follow the steps below.
Set the switch 8 (WB) to the up (M: manual) position, then adjust the
colour.ÃTurn RED (VR302) to set the red ratio and/or BLUE (VR303) to set
the blue ratio.
Synchronization settingsThe default setting is internal synchronization (INT). You can
change the power supply...

Page 16

SETTINGS
External sync adjustment (VBS) (VCC-4592P only)
1Connect the VBS signal output for the other camera to the VBS
IN connector at the rear of this camera.
2
If the signals are not synchronized, change the sub-carrier (SC-P1)
switches as follows.
Setting 9-pin 10-pin
DefaultOFF (down) OFF
Set to 90Æ counterclockwiseOFF ON (up)
Set to 180Æ counterclockwiseON OFF
Set to 270Æ counterclockwiseON ON
Note:
ÃThe sub-carrier switches let you make broad adjustments to the
sub-carrier phase. If finer...

Page 17

SETTINGS
C Ã B/W (colour/black and white) switch setting
This switch lets you select the timing of the automatic switching of
the optical filter to colour image or black and white image, according
to the subject brightness. The default setting is ©Lª. Set the switch
according to the brightness.
(Fig. 2)
H: for a brighter setting than L
L: Standard setting
Notes:ÃAfter the power has been turned off, switching will restart from
colour, when the power is restored.ÃA sound may be heard when the colour image...

Page 18

TROUBLESHOOTINGBefore taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly,
please consult your dealer or a Sanyo Authorized Service Centre.
No picture on the monitor screenÃIs the power turned on to all connected devices? Is the voltage correct?ÃAre all the signal connecting cables correctly connected?ÃIs the lighting sufficient?ÃHas the lens cap been removed?ÃIs the lens type (DC or VIDEO) correctly selected?
Depending...

Page 19

SPECIFICATIONS
Camera:
Scanning system
:PAL standard (625 TV lines, 25
frames/sec.)
Interlace:PLL 2:1 interlace
Image device:1/3 inch solid state image device CCD 
Picture elements:795 (H) x 596 (V)
Effective picture elements:752 (H) x 582 (V)
Synchronizing system:Internal sync, External sync,
Line lock (VCC-4594P only)
Resolution:520 TV lines horizontally, 400 TV lines
vertically
Video output level:1.0 Vp-p/75 ohms, composite
Video S/N ratio:More than 48 dB
Minimum required
illumination
 (incandescent...
Start reading Sanyo Vcc4594 P Manual