    							CONNECTIONS(VCC-4592P only)
    Basic connection for monitoring or recording
    The peripheral devices (VCR, monitor, lens, etc.) and cables are
    sold separately.1
    Make the video signal connection between the camera and
    the monitor or time lapse VCR.
    2
    Use a commercially available 12 V DC adaptor.
    Connect an DC 12 V power source to the 12 V DC input terminal
    on the back of the camera.
    2A:
    When using this unit, the supplied clamping core (A or B) must be
    installed on the power cord and BNC cable, in order to prevent
    electromagnetic interference to the other devices connected.
    3
    The POWER indicator (A) will light. Adjust the picture on the
    monitor using the Brightness and Contrast controls.Coaxial cable type and maximum lengthÃCable type RG-59U (3C-2V), 250 m maximum.ÃCable type RG-6U (5C-2V), 500 m maximum.ÃCable type RG-11U (7C-2V), 600 m maximum.
    CAUTION:ÃThe RG-59U type cable should not be run through electrical
    conduits or through the air.ÃUsing CCTV/Video-grade coaxial cable.
    (Video signal connections)
           : VIDEO IN
           : VIDEO OUT
    (A)
    1
    2A
    2A
    2
    2A
    (A)
    (A)
    (B)
    NC+–
    –
    +DC 12 V
    2A
    (B)
    L53Z4/XE GB 2001, 5, 23
    10 
    English 
    						
    							SETTINGSThe illustration shows the factory default settings for the switches in the camera setup section.
    The camera settings are described on the assumption that a DC type auto iris lens is being used. If you are using a VIDEO type auto iris lens, be
    sure to read the Note which is given. Furthermore, refer to the sticker on the inside of the cover for details on DIP switch positions.
    Control name Position
    1
    Colour and Black/White level switch
    (Normal: L/High sensitivity: H)L
    2
    High speed electronic shutter setting 1/50 sec.
    3
    Electronic Iris (EI)/Auto iris (AI) setting AI
    4
    Aperture compensation setting
    (Sharp: SHRP/Normal: NOR)SHRP
    5
    Backlight compensation mode setting
    (MULT/OFF)OFF
    6
    Backlight compensation setting (BLC)
    (CENT/OFF)OFF
    7
    White balance switch (WB) and colour
    (R or B) adjustment volumeATW
    8
    External sync setting (SYNC: LL/INT)
    (VCC-4594P only)INT
    9
    External sync setting (SC-P1)
    (VCC-4592P only)adjustable
    F
    External sync horizontal adjustment (H-P) adjustable
    G
    Auto-iris lens setting (A.I. LENS), see page 5 DC
    H
    Lens iris level adjustment adjustable
    1C-BWL H
    9
    8 ON
    67
    5 4
    DC
    VIDEOA. I.
    LENSVR301H
    VR302 VR303
    IRIS
    SC/SYNC A
    I E
    I
    OFF ATW
    NOR OFFMULT
    M
    SHRP
    LLSC-P1AP BLC WB
    7
    3
    4
    7
    8
    G
    5
    6
    BLUE R
    E
    D
    3
    2 1
    10
    3 2 1
    ES
    MSB LSB
    VR304
    LEVEL
    2
    H-P
    CENT
    9
    F
    L53Z4/XE GB 2001, 5, 23English
     11 
    						
    							SETTINGS
    High speed electronic shutter setting
    Normally, the speed setting switches for the high speed electronic
    shutter are all set to the down (OFF) position. This sets the electronic
    shutter speed to 1/50 sec. The switches can be set as indicated in
    table A to select one of the 8 speeds available.CAUTION:ÃWhen using the high speed electronic shutter, the switch 4 must
    be set to the down (AI) position.ÃUsing the high speed electronic shutter indoors with low lighting,
    will give darker pictures. In such a case, add some lights to make
    sure the lighting is sufficient. If the lighting is very bright, pay
    attention to the light angle in order to avoid or minimize the
    smear phenomenon effect.
    Table A (switch 1 ~ 3)
    11/50
    21/120
    31/250
    41/500
    51/1000
    61/2000
    71/4000
    81/10000(Unit: sec.)
    Iris function setting
    This should normally be set to the down (AI) position.
    Use a manual or fixed iris lens and set the lens aperture
    to the shortest F stop. Set the switch 4 (IRIS) to the up
    (EI) position.+
    When using an auto-iris lens (for indoor/outdoor use)
    Set the switch 4 (IRIS) to the down (AI) position.
    Note:ÃThe electronic iris is suitable for normal indoor use. When the switch
    4 (IRIS) is set to the up (EI) position, do not use an auto-iris lens.ÃIf used under fluorescent light, the image may flicker. In such a
    case, change to incandescent lighting or set the switch 4 (IRIS) to
    the down (AI) position and use an auto-iris lens.ÃWhen shooting bright subjects, pay attention to the light angle in
    order to avoid or minimize the smear phenomenon effect.ÃIf conditions are outside the electronic iris operation range or
    more than the maximum illumination, it will cause saturation of
    the CCD. In that case, use a manual iris lens.Aperture
    The initial setting for switch 5 is up (SHRP) so that the
    contours of the object are emphasized. However, if the
    contours of the object are already emphasized more
    than required, set switch 5 to the down (NOR) position.
    123
    23 1
    231
    231
    123
    231
    231
    231
    45
    L53Z4/XE GB 2001, 5, 23
    12 
    English 
    						
    							SETTINGS
    Backlight compensation setting
    This camera has two different backlight
    compensation functions: Normally backlight
    compensation switch 6 (MULT) and 7 (CENT)
    are set to the down (OFF) position. Change
    the backlight compensation switch settings
    depending on the conditions.ÃMULT mode:Use this position when applying backlight
    compensation to the whole of the screen.ÃCENT mode:Use this position when applying backlight
    compensation to only the central portion of the
    screen.
    Note:ÃIf switches 6 and 7 are set to the up (ON) position at the same
    time, the MULT setting will have priority.ÃWhen MULT mode is set, scenes with no backlighting may appear
    extremely dark and the object may appear over-exposed. If this
    happens, set to CENT mode.If using a VIDEO type auto-iris lens
    ÃThe ALC volume on the lens should be turned all the way to Av
    (Average).ÃIf the backlight compensation function does not compensate
    properly for the conditions, set using the LEVEL volume on the
    lens.
    6
    7
    (MULT mode: 64 sections)(CENT mode) L53Z4/XE GB 2001, 5, 23
    English
     13 
    						
    							SETTINGS
    White balance adjustment
    Normally the switch 8 (WB) is set to the down (ATW: auto white
    balance) position and the white balance is adjusted automatically. If a
    manual white balance adjustment is necessary, follow the steps below.
    Set the switch 8 (WB) to the up (M: manual) position, then adjust the
    colour.ÃTurn RED (VR302) to set the red ratio and/or BLUE (VR303) to set
    the blue ratio.
    Synchronization settingsThe default setting is internal synchronization (INT). You can
    change the power supply synchronization by moving switch 9
    to the up (LL) position. Refer to ©Line phase adjustmentª
    for details.
    Line phase adjustment (VCC- 4594P only)
    When using a camera switcher to connect 2 cameras or more to one
    monitor, there may be a vertical roll of the images when switched. In
    such a case, set as described below.1
    Set the switch 9 (SYNC) to the up (LL) position.
    2
    Switch the display on the monitor from camera 1 to camera 2.
    Adjust the LINE PHASE volume on camera 2 until the vertical roll
    of the image stops.
    If more than two cameras are used, please repeat this procedure
    for all the cameras.
    CAUTION:If the vertical roll cannot be corrected by setting the LINE PHASE
    volume on camera 2, try setting the LINE PHASE volume on camera
    1. If it still cannot be corrected, please check that the polarity of the
    power cords of all connected devices is correct.
    8
    VR302 VR303
    BLUER
    E
    D
    9
    L53Z4/XE GB 2001, 5, 23
    14 
    English 
    						
    							SETTINGS
    External sync adjustment (VBS) (VCC-4592P only)
    1Connect the VBS signal output for the other camera to the VBS
    IN connector at the rear of this camera.
    2
    If the signals are not synchronized, change the sub-carrier (SC-P1)
    switches as follows.
    Setting 9-pin 10-pin
    DefaultOFF (down) OFF
    Set to 90Æ counterclockwiseOFF ON (up)
    Set to 180Æ counterclockwiseON OFF
    Set to 270Æ counterclockwiseON ON
    Note:
    ÃThe sub-carrier switches let you make broad adjustments to the
    sub-carrier phase. If finer adjustments are required, contact the
    place of purchase.ÃThe type and length of the cable which is connected to the VBS
    connector may cause the horizontal synchronization being out of
    phase. If this happens, adjust VR304 (H-P: horizontal sync).
    Lens iris adjustment
    If using a DC type auto-iris lens, you will need to set the LEVEL
    (VR301) volume when shooting in the conditions described below.
    L (counterclockwise):To decrease the contrast
    H (clockwise):To increase the contrastÃIf shooting simultaneously in a dark room and through a bright
    window.ÃIf the subject background is extremely bright or dark.ÃIf the brightness of the picture on the monitor is not correct.
    10
    9
    VR304
    H-P
    VR301LEVEL
    L53Z4/XE GB 2001, 5, 23English
     15 
    						
    							SETTINGS
    C Ã B/W (colour/black and white) switch setting
    This switch lets you select the timing of the automatic switching of
    the optical filter to colour image or black and white image, according
    to the subject brightness. The default setting is ©Lª. Set the switch
    according to the brightness.
    (Fig. 2)
    H: for a brighter setting than L
    L: Standard setting
    Notes:ÃAfter the power has been turned off, switching will restart from
    colour, when the power is restored.ÃA sound may be heard when the colour image or black and white
    image is switched. Also, the image will be distorted as shown in
    Fig. 2, this is normal and does not indicate a problem.ÃWhen using infrared lighting, if there is a strong reflection on the
    subject, the optical filter may switch from black and white to
    colour mode, Use only enough infrared lighting so that the mode
    is not switched.ÃThe focus setting may be different in black and white mode and
    colour mode. Please check the focus setting in both modes.
    Manual colour/black and white setting
    Connect each pin of the CONTROL terminal as indicated below, to
    set the image to black and white or colour as desired.ÃColour image setting
    Connect the C (colour) and the G (ground) pins.ÃBlack and white setting
    Connect the B (black and white) and the G (ground) pins.CONTROL terminal
    Image
    CB
    OFF OFF Auto
    OFF ON Black and white
    ON OFF colour
    ON ON Auto
    ON: Close
    OFF: Open
    Notes:ÃThe maximum length of cable for CONTROL terminal is 600 m
    (AWG 24).ÃDuring optical filter switching, even if the manual switching
    operation is done, you cannot determine if the image is black and
    white or colour. Manual switching will have to be done one more
    time.
    C-BWL H
    GC BCONTROL
    L53Z4/XE GB 2001, 5, 23
    16 
    English 
    						
    							TROUBLESHOOTINGBefore taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly,
    please consult your dealer or a Sanyo Authorized Service Centre.
    No picture on the monitor screenÃIs the power turned on to all connected devices? Is the voltage correct?ÃAre all the signal connecting cables correctly connected?ÃIs the lighting sufficient?ÃHas the lens cap been removed?ÃIs the lens type (DC or VIDEO) correctly selected?
    Depending on the type of lens, the A. I. LENS switch must be set accordingly.ÃIs the iris control correctly set?
    A:When using a DC type lens, the LEVEL volume (inside the camera casing) should be adjusted.
    B:When using a VIDEO type lens, the LEVEL volume (on the lens) should be adjusted.The picture is not clearÃIs the monitor correctly adjusted?ÃIs the flange-back position correctly set?ÃIs the lens focus correctly adjusted?ÃAre the lens surfaces clean?
    If there is dust or finger prints on the lens, the image quality will deteriorate. To clean the lens use a soft cloth or a commercially available
    lens cleaning set.
    SERVICEThis camera is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a
    problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo
    Authorized Service Centre. L53Z4/XE GB 2001, 5, 23English
     17 
    						
    							SPECIFICATIONS
    Camera:
    Scanning system
    :PAL standard (625 TV lines, 25
    frames/sec.)
    Interlace:PLL 2:1 interlace
    Image device:1/3 inch solid state image device CCD 
    Picture elements:795 (H) x 596 (V)
    Effective picture elements:752 (H) x 582 (V)
    Synchronizing system:Internal sync, External sync,
    Line lock (VCC-4594P only)
    Resolution:520 TV lines horizontally, 400 TV lines
    vertically
    Video output level:1.0 Vp-p/75 ohms, composite
    Video S/N ratio:More than 48 dB
    Minimum required
    illumination
     (incandescent lighting):Approx. 0.03 lux with a F 1.2 lens (B/W
    mode),
    Approx. 0.6 lux with a F 1.2 lens (colour
    mode)
    Control terminal:Manual colour/black and white setting
    Backlight compensation:Manual MULT/CENT switching
    (Active when using an auto-iris lens)
    Iris function:Manual EI/AI switching
    Electronic iris range:0.6 lux to 35,000 lux (F 1.2, lens: colour
    mode)
    1.0 lux to 50,000 lux (F 1.4, lens: colour
    mode)
    Electronic shutter:8 speeds, selectable by switches:
    (1/50, 1/120, 1/250, 1/500, 1/1000,
    1/2000, 1/4000, 1/10000 sec.)
    Flange-back:12.5 mm ± 0.5 mm
    White balance:ATW/Manual switching
    Lens mount:CS mountEnvironmental conditions
    :Temperature: Ä10ÆC ~ +50ÆC
    Humidity: less than 90% (no
    condensation)
    Power supply:24 V AC, 50 Hz (VCC-4594P)
    12 V DC (VCC-4592P)
    Power consumption:VCC-4594P:
    4.1 W (with auto iris lens)
    3.2 W (without auto iris lens)
    VCC-4592P:
    3.3 W (with auto iris lens)
    2.6 W (without auto iris lens)
    Weight:Approx. 450 g (without lens)
    Dimensions: mm
    Features and specifications are subject to change without prior
    notice or obligations.
    136
    126.5
    1
    15.4
    25.211
    1/4”–20 UNC67
    54
    28
    3
    L53Z4/XE GB 2001, 5, 23