Page 81
English How to set 80 Power loss information/Used time 1Power loss Displays the number of power outages. The maximum display of the power outage counter is 999. A count over 999 cannot be displayed. 2LOSS and RECOVER Displays information about the most recent power loss events (loss date and time, recovery date and time), in reverse chronological order, up to four events. Information about earlier events is not available. 3USED TIME DISK1 USE Displays the total running time of hard disk 1. DISK2...
Page 82
English 81 How to set Initialization log 1DATE/TIME Displays the date and time of the initialization. Displays the eight most recent items in the initialization log. Information about earlier initializations is not available. 2AREA Displays the hard disk recording area that was initialized. Display: ALL AREAS, NORMAL REC, ARCHIVE, ALARM REC 3Operations Displays whether the area was INITIALIZED or subject to AREA RESET. Recording area modifications are displayed as INITIALIZED.Use this procedure...
Page 83
English How to set 82 Menu copy Save the set menu on the CF card and load the same menu onto a different DVR of the same model. It is possible to control several units using the same menu. 1DVR version number 2To be selected when saving to be selected when saving the basic menu content to the CompactFlash (CF) card. 3To be selected when the basic menu content saved to the CF card is loaded onto other DVRs of the same model. 4Selecting the area distribution of the recording area Select the below...
Page 84
English Menu copy 83 How to set 1Press the MENU button in order to display the screen and load the menu content onto other DVRs of the same model. 2Turn the J-dial to move the COPY RECORDING AREA SETTINGS. 3Select NO or YES using the J-dial by turning the S-dial. 4Turn the S-dial clockwise. The cursor moves to SAVE MENUS TO CF. 5Turn the J-dial to move the cursor to LOAD MENUS FROM CF and then the S-dial clockwise. A) When NO is selected for COPY RECORDING AREA SETTINGS. The screen will be...
Page 85
English Other 84 Interface (RS-485) specifications bData formatbCommunication protocol It is recommended that the exclusive controller is used for operation as a protocol unique to our company (SANYO protocol) is used for this DVR. Consult the service center regarding the exclusive controller. bProtocol command table The commands available through this DVR are as outlined in the table below. ModeAsynchronous Character length8 bits Data transmission speed2400, 4800, 9600, 19200bps Parity checkNone Stop...
Page 86
English 85 Other Specifications bDimensions (unit: mm) Please note that specifications and unit exterior design are subject to change without notification. bOptions HDD: 80GB/160GB/300GB/500GB CD-R/RW: Expanded disc unit Signal method PAL signal standard Compression methodVideo: M-JPEG, Audio: WAVE Number of pixels720 x 288 Recording typeField record Recording quality5 stage [BASIC/NORMAL/ENHANCED/ FINE/SUPER FINE] Recording rate27 levels (50 to 0.033FPS) Recording areaNormal recording area/alarm...
Page 87
English Other 86 List of recording rate and recording times The recording time on this DVR are adjusted automatically when the recording rate and the recording quality have been altered. The list below displays the recording rate and quality when recording images within the hard disk normal recording area of this DV R . The set times for the normal recording area and/or the alarm recording area will be the product of the recording time shown below by the percentage figure of the normal recording area...
Page 88
English List of recording rate and recording times 87 Other bWhen recording using an 500GB hard disk (when 99% of the area is utilized) Audio signal recordable area (the recording time will be shorter than the figures given below in case audio is recorded) Recording rate (fields/second)Recording timeBASICNORMALENHANCEDFINESUPER FINE15kB22kB30kB42kB50kB50151 (H)107 (H)80 (H)58 (H)49...
Page 89
English Other 88 List of record rate setting/pre-alarm recording times bRecording rate setting (Note 1) Rate setting will be limited when the mirroring function is turned ON or when the pre-alarm recording is turned ON. (Note 2) Rate setting will be limited when the mirroring function is turned ON. (Note 3) It is not possible to choose this setting when only one camera is connected. (Note) The recording rate for each channel is set in program recording. The rates that allow setting in each channel are...
Page 90
English 89 Other Push-lock terminal specifications Input/output terminalsSignal levelInput/output circuit [0 voltage contact] [Open collector/1kΩ, Low Level active (max. 25 mA)] (Refer to P12) Remote input [2 wire voltage control type] (REMOTE R1, R2) Date adjustment input [Zero voltage contact] (CLOCK IN) Clock adjustment output [Open collector/1kΩ, Low Level active (max. 25 mA)] (CLOCK OUT) Alarm total output [Open collector/Low Level active (max. 500 mA)] (ALARM OUT) Alarm reset input [Zero...