Page 81

English
How to set 80
Power loss information/Used time
1Power loss
Displays the number of power outages.
The maximum display of the power outage counter is 999. 
A count over 999 cannot be displayed. 
2LOSS and RECOVER
Displays information about the most recent power loss 
events (loss date and time, recovery date and time), in 
reverse chronological order, up to four events. Information 
about earlier events is not available. 
3USED TIME
DISK1 USE
Displays the total running time of hard disk 1.
DISK2...

Page 82

English
81 How to set
Initialization log
1DATE/TIME
Displays the date and time of the initialization. 
Displays the eight most recent items in the initialization 
log. Information about earlier initializations is not available. 
2AREA
Displays the hard disk recording area that was initialized. 
Display: 
ALL AREAS, NORMAL REC, ARCHIVE, ALARM REC
3Operations
Displays whether the area was INITIALIZED or subject to 
AREA RESET. 
Recording area modifications are displayed as 
INITIALIZED.Use this procedure...

Page 83

English
How to set 82
Menu copy
Save the set menu on the CF card and load the same 
menu onto a  different DVR of the same model. It is 
possible to control several units using the same menu.
1DVR version number
2To be selected when saving to be selected when 
saving the basic menu content to the CompactFlash 
(CF) card.
3To be selected when the basic menu content saved to 
the CF card is loaded onto other DVRs of the same 
model.
4Selecting the area distribution of the recording area
Select the below...

Page 84

English
Menu copy
83 How to set
1Press the MENU button in order to display the 
 screen and load the 
menu content onto other DVRs of the same model.
2Turn the J-dial to move the COPY RECORDING 
AREA SETTINGS.
3Select NO or YES using the J-dial by turning the 
S-dial.
4Turn the S-dial clockwise.
The cursor moves to SAVE MENUS TO CF.
5Turn the J-dial to move the cursor to LOAD MENUS 
FROM CF and then the S-dial clockwise.
A) When NO is selected for COPY RECORDING 
AREA SETTINGS.
The  screen will be...

Page 85

English
Other 84
Interface (RS-485) specifications
bData formatbCommunication protocol
It is recommended that the exclusive controller is used for 
operation as a protocol unique to our company (SANYO 
protocol) is used for this DVR. Consult the service center 
regarding the exclusive controller.
bProtocol command table
The commands available through this DVR are as outlined in the table below.
ModeAsynchronous
Character length8 bits
Data transmission speed2400, 4800, 9600, 19200bps
Parity checkNone
Stop...

Page 86

English
85 Other
Specifications
bDimensions (unit: mm)
Please note that specifications and unit exterior  design are subject to change without notification.
bOptions
HDD: 80GB/160GB/300GB/500GB
CD-R/RW: Expanded disc unit
Signal method PAL signal standard
Compression methodVideo: M-JPEG, Audio: WAVE
Number of pixels720 x 288
Recording typeField record
Recording quality5 stage [BASIC/NORMAL/ENHANCED/
FINE/SUPER FINE]
Recording rate27 levels (50 to 0.033FPS)
Recording areaNormal recording area/alarm...

Page 87

English
Other 86
List of recording rate and recording times
The recording time on this DVR are adjusted automatically when the recording rate and the recording quality have been altered.
The list below displays the recording rate and quality when recording images within the hard disk normal recording area of this 
DV R .
 The set times for the normal recording area and/or the alarm recording area will be the product of the recording time shown 
below by the percentage figure of the normal recording area...

Page 88

English
List of recording rate and recording times
87 Other
bWhen recording using an 500GB hard disk (when 99% of the area is utilized)
 Audio signal recordable area (the recording time will be shorter than the figures given below in case audio is recorded)
Recording rate 
(fields/second)Recording timeBASICNORMALENHANCEDFINESUPER FINE15kB22kB30kB42kB50kB50151 (H)107 (H)80 (H)58 (H)49...

Page 89

English
Other 88
List of record rate setting/pre-alarm recording times
bRecording rate setting
(Note 1) Rate setting will be limited when the mirroring function is turned ON or when the pre-alarm recording is turned ON.
(Note 2) Rate setting will be limited when the mirroring function is turned ON.
(Note 3) It is not possible to choose this setting when only one camera is connected.
(Note) The recording rate for each channel is set in program recording. The rates that allow setting in each channel are...

Page 90

English
89 Other
Push-lock terminal specifications
Input/output terminalsSignal levelInput/output circuit

[0 voltage contact]

[Open collector/1kΩ, Low Level 
active (max. 25 mA)]

(Refer to P12) Remote input
[2 wire voltage control type]
(REMOTE R1, R2)
Date adjustment input
[Zero voltage contact]
(CLOCK IN)
Clock adjustment output
[Open collector/1kΩ, Low Level 
active (max. 25 mA)]
(CLOCK OUT)
Alarm total output
[Open collector/Low Level 
active (max. 500 mA)]
(ALARM OUT)
Alarm reset input
[Zero...