Runco V 63hd Installation And Operation Manual
Here you can view all the pages of manual Runco V 63hd Installation And Operation Manual. The Runco manuals for Television are available online for free. You can easily download all the documents as PDF.
Page 71
Maintenance and Troubleshooting Vistage™ Series Flat-Panel Display Installation/Operation Manual 57 PREL IMINARY 5.1 Troubleshooting TipsTable 5-1 provides some general guidelines for troubleshooting problems you may encounter with the V-50HD/V-63HD. If the suggested solutions fail to resolve the problem or if you encounter an issue not described here, please contact Runco Technical Support. 5. Maintenance and Troubleshooting Table 5-1. Troubleshooting Chart Symptom Possible Cause(s)Solution The...
Page 72
Maintenance and Troubleshooting 58 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY The display is jittery or unstable. Poor-quality or improperly connected source. The horizontal or vertical scan frequency of the input signal may be out of range for the display. Ensure that the source is properly connected and of adequate quality for detection. Correct at the source. Image is too bright and/or lacks definition in the bright areas of the image. Contrast is...
Page 73
External Control Vistage™ Series Flat-Panel Display Installation/Operation Manual 59 PREL IMINARY In addition to using the DHD Controller remote control unit, there are three methods of controlling the V-50HD/V-63HD and DHD Controller externally: Using a serial (RS-232) link to send ASCII commands and receive responses to those commands. Using discrete infrared (IR) codes to program a third-party remote control unit. Using an HDMI connection to send Consumer Electronics Control (CEC) commands...
Page 74
External Control 60 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the...
Page 75
External Control Vistage™ Series Flat-Panel Display Installation/Operation Manual 61 PREL IMINARY Aspect Ratio Commands 16:9 NA YES Selects the 16:9 aspect ratio 4:3 NA YES Selects the 4:3 aspect ratio ASPECT? NA NA Returns current aspect ratio CINEMA NA YES Selects the Cinema aspect ratio LETTERBOX NA YES Selects the Letterbox aspect ratio NATIVE NA YES Selects the Native aspect ratio VIRTUALWIDE NA YES Selects the VirtualWide aspect ratio VIRTUALCINEMA NA YES Selects the Virtual Cinema aspect ratio...
Page 76
External Control 62 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Image Preset Commands CUSTOM1 NA YES Loads “Custom 1” image preset CUSTOM2 NA YES Loads “Custom 2” image preset DAY NA YES Loads “ISF Day” image preset NIGHT NA YES Loads “ISF Night” image preset PRESET? NA NA Returns currently-selected preset (ISF Day, ISF Night, Custom 1 or Cus- tom 2) Input Position Commands IHEIGHT 0/20 YES Sets the value for input height IHEIGHT? NA NA Returns input height value IHPOS...
Page 77
External Control Vistage™ Series Flat-Panel Display Installation/Operation Manual 63 PREL IMINARY Sleep Timer Commands SLEEPTMR? NA NA Returns sleep timer setting STOFF NA YES Sets the sleep timer to Off ST30MIN NA YES Sets the sleep timer to 30 minutes ST60MIN NA YES Sets the sleep timer to 60 minutes ST90MIN NA YES Sets the sleep timer to 90 minutes ST2HRS NA YES Sets the sleep timer to 2 hours ST4HRS NA YES Sets the sleep timer to 4 hours Screen Commands SCREEN? NANAReturns the screen setting SCREEN1...
Page 78
External Control 64 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY 6.2 Using Discrete IR CodesThe DHD Controller accepts commands in the form of IR signals that conform to the Phillips RC5 protocol. Each DHD Controller remote control button has an RC5 control code associated with it. You can use these codes to program a third-party, “universal” remote control unit to work with the DHD Controller. These third-party products usually come with a computer software...
Page 79
External Control Vistage™ Series Flat-Panel Display Installation/Operation Manual 65 PREL IMINARY For example, here is the RC5 control code for the ON button on the DHD Controller remote control unit (assuming the default address is used): Figure 6-1 shows the pulse train for this command (with the toggle bit set to zero). Figure 6-1. RC5 Message Format With Toggle Bit = 0 Hex 3 4 4 1 Binary11 0 10001000001 With Toggle Bit = 1 Hex 3 C 4 1 Binary11 1 10001000001 FunctionStart BitsToggle...
Page 80
External Control 66 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY IR Command ListTable 6-2 lists the RC5 control codes for the DHD Controller. ➤ Table 6-2. RC5 Control Codes for the DHD Controller Remote Control Button NameRC5 Data from Remote Control (Note)RC5 Data with Toggle Bit = 1 (Note)Description 16:9 0x3449 0x3C49 16:9 aspect ratio 4:3 0x344A 0x3C4A 4:3 aspect ratio CINEMA 0x346C 0x3C6C Cinema aspect ratio COMP 0x344E 0x3C4E Component video input CUST 1...