Page 51
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 37 PREL IMINARY Height: Select Height from the Input Position menu to change the projected image height. Press to increase the height; press to decrease it. Overscan/Overscan Mode: Overscan pushes the outside edge of the active picture area of the video signal out beyond the edge of the display area. Some television programs are produced based on the assumption that older television sets may not display the outer edges of...
Page 52
Operation 38 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Phase (RGB, Component or SCART sources): This control adjusts the phase of the pixel sampling clock relative to the incoming signal. Adjust the phase when an RGB, Component or SCART image still shows shimmer or “noise” after Tracking has been optimized. For best results, use a good test pattern such as a smooth gray consisting of a clear pattern of black and white pixels, or a similar “half on, half off”...
Page 53
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 39 PREL IMINARY You should save changes to any of the following settings to a preset; otherwise they will be lost when a new input source or resolution is selected: Brightness Color saturation Sharpness Color temperature and white balance To select a memory preset, press or to highlight it and press ENTER. To save the settings for the current input and display mode to the Custom 1 or Custom 2 memory preset, select...
Page 54
Operation 40 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY InformationSignal / System: Select Information from the Main Menu, then choose either Signal or System to display information about the current input signal (resolution, frequency, type et cetera) and installed firmware versions, as well as other information that uniquely identifies your DHD Controller and display device. Should you ever need to contact Runco Technical Support, this information will help them...
Page 55
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 41 PREL IMINARY Calibration Use the Calibration menu to perform advanced picture quality adjustments. This menu should be used by ISF-certified technicians only. To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the Memory Presets menu (see page 38) or use the corresponding remote control buttons. Display Color - Common Settings: Use the Display Color - Common Settings menu to adjust the color...
Page 56
Operation 42 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Color Temp: Select Color Temp from the Display Color - Common Settings menu to adjust the color temperature. Color temperature establishes the “color of gray” by adjusting the 75% white point to various color points. What are “color points?”A “color point” is an x/y coordinate pair that defines a color’s location on the standard CIE chromaticity graph, shown in Figure 4-7. (CIE stands for “Commission...
Page 57
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 43 PREL IMINARY Display Color - Panel Settings: These settings are also saved independently for each input and display mode. Panel Brightness: The Panel Brightness control changes the apparent brightness of the displayed image. Its effect is similar to that of a lamp intensity control on a projector. Use a higher setting for rooms with a lot of ambient light. Use a lower setting for more “theater-like” viewing conditions...
Page 58
Operation 44 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Save ISF Night/Save ISF Day: Whenever you make a change to the ISF settings, you should always save it. Select Save ISF Night or Save ISF Day from the Calibration menu to do this. Copy/Paste - Memory Preset: You can copy and paste settings from one memory preset to another. This gives you a convenient starting point for creating a new preset based on an existing one, to make the calibration process less...
Page 59
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 45 PREL IMINARY spect Ratio - Paste Settings: To apply the Output Shift and Image Alignment settings on the clipboard to a different aspect ratio and/or screen, do either of the following: Switch to another aspect ratio (for example, from 16:9 to Cinema). Switch from Screen 1 to Screen 2 or vice versa. Then, select Paste Settings from the Copy/Paste Aspect Ratio menu. The new settings are saved automatically. Output Shift:...
Page 60
Operation 46 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY To correct keystoning or pincushion distortion: 1. On the DHD Controller remote control or front panel, press MENU. 2. Select Calibration from the Main Menu and enter the Calibration Menu passcode. 3. Select Image Alignment from the Calibration Menu. 4. Select Corner Alignment to correct a “keystoned” image by adjusting the image corner positions. Select Midpoint Alignment to correct pincushion distortion by...