External Control LightStyle™ LS-12HBd Installation/Operation Manual 115 PREL IMINARY Trigger 1 16:9 T11 R/W No 0 1 No 0 = Off; 1 = On Trigger 1 4:3 T12 R/W No 0 1 No Trigger 1 Letterbox T13 R/W No 0 1 No Trigger 1 VirtualWide T14 R/W No 0 1 No Trigger 1 Cinema T15 R/W No 0 1 No Trigger 1 Virtual Cinema T16 R/W No 0 1 No Trigger 1 Native T17 R/W No 0 1 No Trigger 2 16:9 T21 R/W No 0 1 No Trigger 2 4:3 T22 R/W No 0 1 No Trigger 2 Letterbox T23 R/W No 0 1 No Trigger 2 VirtualWide T24 R/W No 0 1 No Trigger 2 Cinema T25 R/W No 0 1 No Trigger 2 Virtual Cinema T26 R/W No 0 1 No Trigger 2 Native T27 R/W No 0 1 No Trigger 3 16:9 T31 R/W No 0 1 No Trigger 3 4:3 T32 R/W No 0 1 No Trigger 3 Letterbox T33 R/W No 0 1 No Trigger 3 VirtualWide T34 R/W No 0 1 No Trigger 3 Cinema T35 R/W No 0 1 No Trigger 3 Virtual Cinema T36 R/W No 0 1 No Trigger 3 Native T37 R/W No 0 1 No 3D Test Pattern Enable TDE R/W No 0 1 No 0 = Off; 1 = On 3D Mode TDM R/W No 0 4 No 0 = Auto 1 = Off 2 = Side-by-Side 3 = Top-and-Bottom 4 = Frame Packing 3D Reverse Eyes TDR R/w No 0 1 No 0 = Off; 1 = On Image Alignment Top Left x TLX R/W Yes -100 100 No Image Alignment Top Left y TLY R/W Yes -100 100 No 3D Test Pattern Enable TME R/W No 0 1 No 0 = Off; 1 = On Image Alignment Top Middle x TMX R/W Yes -100 100 No Image Alignment Top Middle y TMY R/W Yes -100 100 No Tint Offset TNO R/W Yes -50 50 No Picture menu Tint TNT R/W Yes -50 50 No Calibration -> Input Image menu Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control 116 LightStyle™ LS-12HBd Installation/Operation Manual PREL IMINARY Test Pattern Enable TPE R/W No 0 1 No 0 = Off; 1 = On Primary Test Pattern TPP R/W No 0 1 No 0 = Off; 1 = On Secondary Test Pattern TPS R/W No 0 1 No 0 = Off; 1 = On Tracking TRK R/W Yes -100 100 No Image Alignment Top Right x TRX R/W Yes -100 100 No Image Alignment Top Right y TRY R/W Yes -100 100 No Display 3D Sync Delay TSD R/W Yes Var. Var. No Display 3D Sync Invert TSI R/W No 0 1 No 0 = Not Inverted; 1 = Inverted Test Video TST R/W No 0 4 No 1 = Color Bars 1 2 = Full White 11 = Color Bars 2 12 = Gray Bars 13 = Focus 14 = Off 15 = Off (Restore OSD) 16 = Primary Alignment 17 = Secondary Alignment 18 = Dual Alignment 19 = 3D VFD Text Line 1 VF1 W No N/A N/A Yes 24 characters max VFD Text Line 2 VF2 W No N/A N/A Yes 24 characters max VFD Brightness VFD R/W Yes 0 4 No 0 = 0% 1 = 25% 2 = 50% 3 = 75% 4 = 100% Vertical Shift VSH W Yes 0 0 No Send (VSH+) or (VSH-) to adjust incrementally Zoom ZOM W Yes 0 0 No Send (ZOM+) or (ZOM-) to adjust incrementally Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control LightStyle™ LS-12HBd Installation/Operation Manual 117 PREL IMINARY 6.2 Using Discrete IR CodesThe Dimension Digital Controller accepts commands in the form of IR signals that conform to the NEC protocol. Each Dimension Digital Controller remote control button has an NEC control code associated with it. You can use these codes to program a third-party, “universal” remote control unit to work with the Dimension Digital Controller. These third-party products usually come with a computer software application for this purpose. For more information, consult the documentation provided with the remote control unit. IR Command Protocol The IR control codes have the following characteristics: Each code consists of the following: leader pulse (a modulated pulse of 9 ms followed by a non-modulated pulse of 4.5 ms); address bits. The default address is 82 09 (0x2011, binary 00100000 00010001). To change it, select Remote Control from the Service menu and follow the steps given on page 83; data bits: eight (8) bits for the command followed by the logical inverse of the command; and end pulse (a modulated pulse of 0.56 ms, similar to the modulated pulse in the ‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data transmission. The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle. Commands are sent at a maximum rate of 9 Hz. For example, here is the NEC control code for the ON button on the Dimension Digital Controller remote control unit (assuming the default address is used): Figure 6-1 shows the pulse train for this command. Figure 6-1. NEC Protocol Message Format Hex201101FE Binary 00100000 0001000100000001 11111110 Function Address Byte 1 Address Byte 2 CommandCommand (Logical Inverse) 9 ms 13.5 ms 27 ms 27 ms Address Byte 1 Leader Pulse Address Byte 2 Command Byte Command Byte (logical inverse) 001 000000001 0001 00000001 1 1 1 1 1 1 1 04.5 msEnd Pulse
External Control 118 LightStyle™ LS-12HBd Installation/Operation Manual PREL IMINARY IR Command List (Standard Mode)Table 6-2 lists the NEC control codes for the Dimension Digital Controller. ➤ Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description ON 8209 1 0x201101FE Power on OFF (standby) 8209 2 0x201102FD Power off 16:9 8209 3 0x201103FC 16:9 aspect ratio 4:3 8209 4 0x201104FB 4:3 aspect ratio LETBOX 8209 5 0x201105FA Letterbox aspect ratio V-WIDE 8209 6 0x201106F9 VirtualWide aspect ratio CINEMA 8209 7 0x201107F8 Cinema aspect ratio V-CINE 8209 8 0x201108F7 Virtual Cinema aspect ratio NATIVE 8209 9 0x201109F6 Native aspect ratio 1 8209 10 0x20110AF5 Number Button 1 2 8209 11 0x20110BF4 Number Button 2 3 8209 12 0x20110CF3 Number Button 3 4 8209 13 0x20110DF2 Number Button 4 5 8209 14 0x20110EF1 Number Button 5 6 8209 15 0x20110FF0 Number Button 6 7 8209 16 0x201110EF Number Button 7 8 8209 17 0x201111EE Number Button 8 9 8209 18 0x201112ED Number Button 9 0 8209 19 0x201113EC Number Button 0 ISF DAY 8209 20 0x201114EB ISF Day memory preset ISF NIGHT 8209 21 0x201115EA ISF Night memory preset SCREEN 1 8209 22 0x201116E9 Selects “Screen 1” CUST 1 8209 23 0x201117E8 Custom 1 memory preset CUST 2 8209 24 0x201118E7 Custom 2 memory preset SCREEN 2 8209 25 0x201119E6 Selects “Screen 2” MENU 8209 26 0x20111AE5MENU EXIT 8209 27 0x20111BE4EXIT Up 8209 28 0x20111CE3 Up-Arrow ( ) Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control LightStyle™ LS-12HBd Installation/Operation Manual 119 PREL IMINARY Right 8209 29 0x20111DE2 Right-Arrow ( ) Down 8209 30 0x20111EE1 Down-Arrow ( ) Left 8209 31 0x20111FE0 Left-Arrow ( ) ENTER 8209 32 0x201120DFENTER SRC 1 8209 33 0x201121DE Video Source 1 SRC 2 8209 34 0x201122DD Video Source 2 SRC 3 8209 35 0x201123DC Video Source 3 SRC 4 8209 36 0x201124DB Video Source 4 SRC 5 8209 37 0x201125DA Video Source 5 SRC 6 8209 38 0x201126D9 Video Source 6 SRC 7 8209 39 0x201127D8 Video Source 7 SRC 8 8209 40 0x201128D7 Video Source 8 SRC 9 8209 41 0x201129D6 Video Source 9 SRC 10 8209 42 0x20112AD5 Video Source 10 SRC 11 8209 43 0x20112BD4 Video Source 11 SRC 12 8209 44 0x20112CD3 Video Source 12 SRC 13 8209 43 0x20112BD4 Video Source 13 SRC 14 8209 46 0x20112ED1 Video Source 14 3D AUTO 8209 47 0x20112FD0 3D Mode = Auto 3D SBS 8209 48 0x201130CF 3D Mode = Side-by-Side 3D TAB 8209 49 0x201131CE 3D Mode = Top-and-Bottom 3D FP 8209 50 0x201132CD 3D Mode = Frame Packing STOFF 8209 65 0x201141BE Sets the sleep timer to Off ST30MIN 8209 66 0x201142BD Sets the sleep timer to 30 minutes ST60MIN 8209 67 0x201143BC Sets the sleep timer to 60 minutes ST90MIN 8209 68 0x201144BB Sets the sleep timer to 90 minutes ST2HRS 8209 69 0x201145BA Sets the sleep timer to 2 hours ST4HRS 8209 70 0x201146B9 Sets the sleep timer to 4 hours VIDEO 1 8209 71 0x201147B8 Composite video input 1 Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) (continued) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control 120 LightStyle™ LS-12HBd Installation/Operation Manual PREL IMINARY COMP 8209 72 0x201148B7 Component video input HD 1 8209 73 0x201149B6 HD1 video input HD 2 8209 74 0x20114AB5 HD2 video input HDMI 1 8209 75 0x20114BB4 HDMI1 video input HDMI 2 8209 76 0x20114CB3 HDMI2 video input HDMI 3 8209 77 0x20114DB2 HDMI3 video input HDMI 4 8209 78 0x20114EB1 HDMI4 video input HDMI 5 8209 79 0x20114FB0 HDMI5 video input HDMI 6 8209 80 0x201150AF HDMI6 video input HDMI 7 8209 81 0x201151AE HDMI7 video input HDMI 8 8209 82 0x201152AD HDMI8 video input DisplayPort 8209 83 0x201153AC DisplayPort video input SCART 8209 84 0x201154AB SCART video input VIDEO 2 8209 85 0x201155AA Composite video input 2 VIDEO 3 8209 86 0x201156A9 Composite video input 3 3D OFF 8209 87 0x201157A8 3D Mode = Off Auto Cinema 8209 88 0x201158A7 Auto Cinema aspect ratio Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) (continued) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control LightStyle™ LS-12HBd Installation/Operation Manual 121 PREL IMINARY IR Command List (Extended Mode) Table 6-3 lists the Extended-mode NEC control codes for the Dimension Digital Controller. To use the remote control unit in extended mode, set the address code to 88999 (refer to Remote Control on page 83). Table 6-3. NEC Control Codes for the Dimension Digital Controller (Extended Mode) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description ON 8209 65 0x201141BE Sets the sleep timer to Off OFF (standby) 8209 66 0x201142BD Sets the sleep timer to 30 minutes 16:9 8209 67 0x201143BC Sets the sleep timer to 60 minutes 4:3 8209 68 0x201144BB Sets the sleep timer to 90 minutes LETBOX 8209 69 0x201145BA Sets the sleep timer to 2 hours V-WIDE 8209 70 0x201146B9 Sets the sleep timer to 4 hours CINEMA 8209 71 0x201147B8 Composite video input 1 V-CINE 8209 72 0x201148B7 Component video input NATIVE 8209 73 0x201149B6 HD1 video input 1 8209 74 0x20114AB5 HD2 video input 2 8209 75 0x20114BB4 HDMI1 video input 3 8209 76 0x20114CB3 HDMI2 video input 4 8209 77 0x20114DB2 HDMI3 video input 5 8209 78 0x20114EB1 HDMI4 video input 6 8209 79 0x20114FB0 HDMI5 video input 7 8209 80 0x201150AF HDMI6 video input 8 8209 81 0x201151AE HDMI7 video input 9 8209 82 0x201152AD HDMI8 video input 0 8209 83 0x201153AC DisplayPort video input ISF DAY 8209 84 0x201154AB SCART video input ISF NIGHT 8209 85 0x201155AA Composite video input 2 SCREEN 1 8209 86 0x201156A9 Composite video input 3 CUST 1 8209 87 0x201157A8 3D Mode = Off CUST 2 8209 88 0x201158A7 Auto Cinema aspect ratio Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control 122 LightStyle™ LS-12HBd Installation/Operation Manual PREL IMINARY 6.3 Using HDMI CEC MessagesThe Dimension Digital Controller accepts and can respond to CEC command messages from a disc player, satellite receiver or DVR/set-top box via an HDMI connection. Using CEC, the Dimension Digital Controller can perform the following actions: Turn itself and the projector on and select the correct input when the source component initiates playback of a disc or recorded program. Turn the source component on when you switch to its corresponding input on the Dimension Digital Controller. Turn the source component off when the LS-12HBd system is turned off (unless the source component is in playback mode). Change its OSD language when a similar change is made at the source. To use CEC, connect your CEC-compatible sources to the HDMI inputs on the Dimension Digital Controller. Set the CEC option to On (refer to CEC on page 92). Additional steps may be needed to enable CEC at the source. Refer to the documentation for your source device for more information. CEC Command ListTable 6-4 lists the CEC commands supported by the Dimension Digital Controller. ➤ Table 6-4. CEC Commands Supported by the Dimension Digital Controller Opcode ValueSupported? (√ = Yes, – = No) Initiator Follower Feature Abort 0x00 √√ Standby 0x36 √√ Routing Change 0x80 √√ Routing Information 0x81 √√ Active Source 0x82 √√ Request Active Source 0x85 √√ Device Vendor ID 0x87 √√ Give Device Vendor ID 0x8C √√ Vendor Command With ID 0xA0 √√ Polling Message N/A √√ Text View On 0x0D √ – Report Physical Address 0x84 √ – Inactive Source 0x9D √ – CEC Version 0x9E √ – Set OSD Name 0x47 √ – Menu Status 0x8E √ – Report Power Status 0x90 √ –
External Control LightStyle™ LS-12HBd Installation/Operation Manual 123 PREL IMINARY Set Menu Language 0x32–√ Give Physical Address 0x83 –√ Set Stream Path 0x86 –√ Get CEC Version 0x9F –√ Abort Message 0xFF –√ User Control Pressed 0x44 –√ User Control Released 0x45 –√ Give OSD Name 0x46 –√ Menu Request 0x8D –√ Give Device Power Status 0x8F –√ The Dimension Digital Controller does not transmit HDMI CEC control messages from the “HDMI Audio Out” connector. Table 6-4. CEC Commands Supported by the Dimension Digital Controller (continued) Opcode ValueSupported? (√ = Yes, – = No) Initiator Follower Note
External Control 124 LightStyle™ LS-12HBd Installation/Operation Manual PREL IMINARY Notes: