Ricoh B230 Service Manual
Here you can view all the pages of manual Ricoh B230 Service Manual. The Ricoh manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 261
SM 4-21 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: Bk The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K]. ƒ Defective ASIC (Lupus) ƒ Poor connection between controller and BICU. ƒ Defective BICU 230 D 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board. No. Type Details...
Page 262
B230/B237 4-22 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: Y ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. ƒ The PFGATE ON signal still asserts when the next job starts. 233 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: M The PFGATE ON signal does not assert within 5 seconds...
Page 263
SM 4-23 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: C ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. ƒ The PFGATE ON signal still asserts when the next job starts. 237 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 240 C LD error: Bk 241 C LD error: Y 242 C LD error: M...
Page 264
B230/B237 4-24 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Line position adjustment (MUSIC) error Line position adjustment fails four consecutive times. ƒ Pattern sampling error ( insufficient image density ) ƒ Defective ID sensors for the line position adjustment ƒ Defective image transfer belt unit ƒ Defective PCU(s) ƒ Defective laser optics housing unit 285 D 1. Do the recovery procedure for SC285 (see Laser Optics Housing Unit in Replacement &...
Page 265
SM 4-25 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter sensor time over error: Close The shutter close sensor does not detect ON for 2000msec after the shutter motor turns on. ƒ Defective shutter close sensor ƒ Disconnected or broken harness ƒ Defective shutter motor ƒ Defective shutter ƒ Shutter motor overload ƒ Defective IOB 290 D 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit....
Page 266
B230/B237 4-26 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 2: Close The shutter close sensor detects ON after SC 291 has occurred. ƒ Defective motor ƒ Change of load to shutter motor 292 D 1. Replace the shutter on the laser optics housing unit.
Page 267
SM 4-27 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter sensor time over error: Open The shutter open sensor does not detect ON for 2000msec after the shutter motor turns on. ƒ Defective shutter close sensor ƒ Disconnected or broken harness ƒ Defective shutter motor ƒ Defective shutter ƒ Shutter motor overload ƒ Defective IOB 293 D 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit....
Page 268
B230/B237 4-28 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 2: Open The shutter open sensor detects ON after SC 291 has occurred. ƒ Defective motor ƒ Change of load to shutter motor 295 D 1. Replace the shutter on the laser optics housing unit. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter open/close sensor error Both shutter open sensor and close sensor detect ON at the same time. ƒ Broken...
Page 269
SM 4-29 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 300 D AC charge output error [K] 301 D AC charge output error [M] 302 D AC charge output error [C] 303 D AC charge output error [Y] The measured voltage is not proper when BICU measures the charge output for each color. ƒ Disconnected or broken high voltage cable ƒ Defective or not installed PCU ƒ Defective high voltage power supply 1. Check or replace the...
Page 270
B230/B237 4-30 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 360 D TD sensor (Vt high) error 1: K 361 D TD sensor (Vt high) error 1: M 362 D TD sensor (Vt high) error 1: C 363 D TD sensor (Vt high) error 1: Y ƒ The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. ƒ The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value...