11
5. SETTING THE HOUR
The time is set using AM or PM.
Press the MEMORY button to advance 
by increments of one hour. 
Press the Date/Time Setting button to set 
the current hour.  
The minutes flash on the display.
6.    SETTING THE MINUTE
Press the MEMORY button to advance by 
increments of one minute.
Press the Date/Time Setting button to set 
the current minute. The year flashes on the display.
Press the START/STOP button to turn
the display off.
SETTING THE DATE AND TIME
HEM-741CAN_EN_FR_r1.qxp...

Page 12

12
1. Make sure the air plug is securely insertedin the main unit.
2. Remove tight-fitting clothing from your upper arm.
3. Sit in a chair with your feet flat on the floor.  Place your arm on a table so the cuff is level with your heart.
APPLYING THE ARM CUFF
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 11 

Page 13

13
4. Apply the cuff to your left upper arm so the blue arrow is centered on the inside of your arm and aligned with your middle finger. 
The air tube runs down the inside of your arm. The bottom 
of the cuff should be approximately 1/2" above your elbow.
APPLYING THE ARM CUFF
1/2 inch (1 - 2 cm)
Air Tube
Arrow
APPLYING THE CUFF ON THE RIGHT ARM
When taking a measurement using the right arm use this instruction.
Apply the cuff to your right upper arm
so the blue arrow and the air tube runs 
along the...

Page 14

14
The monitor automatically determines your ideal inflation level. 
In rare circumstances when a higher inflation may be necessary, the
monitor automatically re-inflates the cuff up to 30 mmHg higher than
the initial inflation and restarts the measurement.
1. 
Press the START/STOP button.
All display symbols appear on the screen. The cuff starts to inflate
automatically. 
As the cuff begins to inflate, the monitor automatically determines
your ideal inflation level. Because this monitor detects the...

Page 15

15
You3blood pressure and pulse rate are displayed.
4. 
Press the START/STOP button.
The monitor turns off.
NOTE: The monitor will automatically
turn off after five minutes.
INSTRUCTIONS FOR SPECIAL CONDITIONS
If your systolic pressure is known to be
more than 220 mmHg, press and hold the
START/STOP button until the monitor
inflates 30 to 40 mmHg higher than your
suspected systolic pressure.
NOTES: • Do not apply more pressure than necessary. 
• The monitor will not inflate above 299 mmHg.
TAKING A...

Page 16

16
Every time you complete a measurement the monitor stores the blood
pressure and pulse rate in the memory. The blood pressure monitor
automatically stores up to 30 measurement values. When 30 sets of
measurement values are stored in the memory, the oldest record is
deleted to save the most recent measurement values.
AVERAGING FUNCTION
The monitor also calculates an average reading based on the values of
the three most recent measurements that were taken within 10 minutes
of the most recent reading....

Page 17

TO DELETE ALL VALUES STORED IN THE MEMORY
You cannot partially delete records stored in the memory.
All records will be deleted.
1.Press the MEMORY button. 
2. While holding the  MEMORYand the START/STOP button 
simultaneously for more than 2 seconds all records will be deleted.
17
TO DISPLAY THE MEASUREMENT VALUES
The date and time is alternately displayed with the measurement values.
1. 
Press the MEMORY button to display the most recent 
measurement values on the screen.
NOTES: • Press the button...

Page 18

18
To keep your digital blood pressure monitor in the best condition and
protect the unit from damage follow the directions listed below:
Do not forcefully bendthe arm cuff or air tube. Do not fold tightly.
Clean the monitor with a soft dry cloth. Do not use any abrasive or
volatile cleaners. Do not attempt to clean the cuff. Never immerse the
monitor or any components in water. 
Store the monitor in a safe and dry location. Do not subject the monitor
to extreme hot or cold temperatures, humidity or...

Page 19

19
ERROR INDICATORS
SYMBOLCAUSECORRECTION
Cuff 
under-inflated.
Remove the arm cuff.  Read, 
“Taking a Measurement”.
Wait 2-3 minutes.Take another 
measurement. 
Cuff 
over-inflated.
Movement 
during 
measurement.Remove the arm cuff.
Wait 2-3 minutes.Take another 
measurementand remain still  until the 
measurement is complete.
Batteries 
are worn.Replace the four batteries. Refer to 
“Battery Installation”.
Blinking or Steady
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 18 

Page 20

20
TROUBLESHOOTING TIPS
PROBLEMCAUSES AND SOLUTIONS
No power.
No display appears on the unit.Replace worn batteries.
Check the battery installation 
for proper placement of the 
battery polarities.
Measurement values appear
too high or too low.
Blood pressure varies constantly.
Many factors including stress, time 
of day, how you wrap the cuff, may
affect your blood pressure. 
Review the sections “Before Taking 
a Measurement” and “Taking 
a Measurement.”