Automatic Blood Pressure Monitorwith Arm Cuff
ModelHEM-741CAN
INSTRUCTION MANUAL
ENGLISH 
HEM-741
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 1 

Page 2

2
Before Using the Monitor
Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .\
 . . . . . .3
Important Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4    
Before Taking a Measurement  . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Operating Instructions
Know Your Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .\
 . . .6
Unit Display   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 3

3
Thank you for purchasing the Omron®HEM-741CAN IntelliSense®
Automatic Blood Pressure Monitor.
INTRODUCTION
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
Staple your purchase receipt here
Your new digital blood pressure monitor uses the oscillometric method
of blood pressure measurement. This means the monitor detects your
blood’s movement through your brachial artery and converts the
movements into a digital reading. An oscillometric monitor does...

Page 4

4
To assure the correct use of the product basic safety measures should
always be followed including the precautions listed below:
Read all information in the instruction book and any other literatureincluded in the box before using the unit.
Contact your physician for specific information about your bloodpressure. Follow the instructions of your healthcare provider. 
Operate the unit only as intended. Do not use for any other purpose.
The unit is intended for use in measuring blood pressure and...

Page 5

5
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 
15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your left arm.
5. Sit in a chair with your feet flat on the floor. Rest your...

Page 6

6
KNOW YOUR UNIT
Air Jack
HEM -7
41
Main Unit:
Battery Compartment
START/STOP 
Button
MEMORY Button
Date/Time Setting Button Display
AC Adapter Jack
Components:
Arm CuffAir Tube
Air Plug 
(Connects to Air Jack)
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 5 

Page 7

7
UNIT DISPLAY
IRREGULAR HEARTBEAT SYMBOLWhen the monitor detects an irregular rhythm two or more than two
times during the measurement, the Irregular Heartbeat Symbol (      ) \
will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined 
as a rhythm that varies by less than 25%
from the average rhythm or 25% more than
the average rhythm detected while the 
monitor is measuring the systolic and
diastolic blood pressure.
If the irregular heartbeat symbol (      )...

Page 8

8
1. Press the ▲
indicator on the battery cover
and slide the cover off in the direction of
the arrow.
2. Install 4 “AA” size batteries so the  + (positive) and - (negative) polarities
match the polarities of the battery 
compartment as indicated.
3. Replace the battery cover.
BATTERY REPLACEMENT
Initial Set-Up
When the Low Battery Symbol ( ) appears on the display screen
remove all the batteries. Replace with four new batteries at the same
time. When the Low Battery Symbol ( ) blinks a brief period of...

Page 9

9
Set the monitor to the current date and time before taking a measurement\
for the first time. If the correct date and time are not set, the measur\
ement
values stored in the memory and the average value will not be correct.
The Blood Pressure Monitor automatically stores up to 30 measurement
values with the date and time. The monitor also calculates an average
reading based on the three most recent measurements taken within 10
minutes of the last reading.
NOTES:
• If only two readings are stored in...

Page 10

10
SETTING THE DATE AND TIME
2. SETTING THE YEARThe year can be set between 2005 and
2030. When the display reaches 2030, 
it will return to 2005.
Press the MEMORY button to advance 
by increments of one year. 
Press the Date/Time Setting button to set 
the current year.
The month flashes on the display.
NOTE: • Press and hold the MEMORY button to advance the date and time values faster. 
3. SETTING THE MONTH Press the MEMORY button to advance by
increments of one month. 
Press the Date/Time Setting...