Home > ReliOn > Blood Pressure Monitor > ReliOn Bp200 Hem 741crel 3 Manual

ReliOn Bp200 Hem 741crel 3 Manual

Here you can view all the pages of manual ReliOn Bp200 Hem 741crel 3 Manual. The ReliOn manuals for Blood Pressure Monitor are available online for free. You can easily download all the documents as PDF.

Page 21

21
QUICK REFERENCE GUIDE
To ensure a reliable reading, avoid eating, drinking alcohol, smoking,
exercising, and bathing for 30 minutes before taking a measurement.
You should try to measure your blood pressure at the same time each day.
Avoid taking measurements during stressful times.
1. Remove any tight-fitting clothing from your upper arm. 
2. Sit in a chair with your feet flat on the floor and place your arm on\
  a table so the cuff is at the same level as your heart.
3. Apply the cuff to your left...

Page 22

22
5. Press the START/STOP button.Display symbols appear. The cuff starts 
to inflate automatically.
Remain still and do not talk during 
the measurement.NOTE: To stop the inflation or measurement, push the
START/STOP button. The monitor will stop
inflating, start deflating, and will turn off.
6. When the measurement is complete, the arm cuff  completely deflates. Your blood pressure and pulse rate
are displayed.
NOTE: Wait 2-3 minutes between measurements. The wait time
allows the arteries to return to...

Page 23

23
FCC STATEMENT
NOTE:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with the limits for a C\
lass B
digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmf\
ul
interference in a residential installation. The product generates, uses, and can
radiateradio frequency energy and, if not installed and used in accordance  with
the instructions, may cause harmful int erference...

Page 24

WARRANTY INFORMATION
24
Your HEM-741CAN, IntelliSense®Automatic Blood Pressure Monitor, excludingthe monitor
cuff, is warranted to be free from defects in materials and workmanship appearing within 2 years
from the date of purchase, when used in accordance with the instructions\
 provided with the
monitor. The monitor cuff is warranted to be free from defects in materials and workmanship
appearing within one  year from the date of purchase when the monitor is used in accordance
with the instructions...

Page 25

25
Model:HEM-741CAN (HEM-7051-CAN)
Display: LCD Digital Display
Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40-180/min.
Memory:30 measurements with date and time
Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading
Pulse: ±5% of reading
Inflation: Automatic by electric pump
Deflation: Automatic pressure release valve
Rapid Air Release: Automatic exhaust valve
Pressure Detection: Capacitive pressure sensor
Measurement Method: Oscillometric method
Pulse Wave Detection: Capacitance type pressure...

Page 26

NOTES
26
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 25 

Page 27

NOTES
27
HEM-741CAN_EN_FR_r1.qxp  5/26/09  9:13 PM  Page 26 

Page 28

Made in China
OMRON HEALTHCARE, INC.
1200 Lakeside Drive
Bannockburn, Illinois 60015
www.omronhealthcare.com
Copyright © 2009 Omron Healthcare, Inc.