    Have a look at the manual Panasonic Video Multiplexer Wj Fs616 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-49-
    OPERATING PROCEDURES (with WV-CU550A)
    Direction Arrow Button
    LEFT
    RIGHT UP
    DOWNHOME/SET
    Joystick Controller
    LEFT RIGHTUP
    DOWN
    Camera Selection Buttons
    4
    8
    12
    16
    3
    7
    11
    15
    2
    6
    10
    14
    1
    5
    9
    13
    CAMERA/PRESET   POSITION
    Numeric Key + Set Key
    123
    456
    789
    MON CAM
    UNIT/ESC0
    SET
    F3F4F2F1
    U01   C01_MLT ∗SPOT _ SEQ _VCR
    123
    456
    789
    MO N C A M
    UNIT/ESC SET0
    When operating the Video Multiplexer with the WV-
    CU550A System Controller, the following buttons and
    keys of the System Controller correspond with those of
    the Video Multiplexer.
    While the ALTbutton is in ON position, control of the
    VCR with the buttons shown below is enabled.
    : Rewind FUNCTION
    : Pause PRE-POSI
    : Fast Forward STILL
    : Reverse Play CAMERA SET ON A
    : Stop EL-ZOOM
    : Play CAMERA SET OFF B
    : T/L modeC
    : T/L mode SET UP D
    : Record MULTISCREEN SELECT
    /
    /
    MONITOR CONTROL 
    FUNCTION
    1. Press the Controller On/Off Switch located on the
    rear of the System Controller to the ON position.
    The display shown below appears on the System
    Controller’s LCD.
    The Function Buttons operate as shown below.
    F1:Same operation as MULTISCREEN button
    F2:Same operation as SPOT button
    F3:Same operation as SEQUENCE button
    F4:Same operation as VCR/CAM button
    _ Mode OFF
    ✴MODE ON
    2. Set the LCD display to ✴SPOTor ✴MLTby press-
    ing the F2 orF1button on the controller.
    3. Select the desired camera by pressing the numeric
    keys, then press the SETkey.
    The selected camera picture is displayed in Single
    Spot on the selected monitor screen.
    Note:Proceed as described for Monitor Control
    Function on page 38 to 42. Refer to the supplied panel templates for the other
    buttons.
    Note:When controlling with the WV-CU550A, it is
    recommended to set the LOCKswitch on the
    WJ-FS616 to the ONposition to prevent false
    operation.
    Unit NumberCamera Number(“Mlt”or “Seq”)Playback, PRE-POSI,
    STILL, camsetup 
    						
    							-50-
    FOCUS
    NEAR
    FARAF
    ZOOM
    TELE
    WIDE
    CLOSE OPENIRIS
    PRE-
    POSI
    123
    456
    789
    MO N C A M
    UNIT/ESC SET0
    AUTO/+
    AUX2
    CAMERA CONTROL 
    FUNCTION
    Camera control is only available while the camera
    picture is displayed in Single Spot on the monitor
    screen.
    Note:When controlling the camera with multiplexed
    control data by connecting a coaxial cable, you
    should install the optional WV-PB6164 Data
    Multiplex Board in the Video Multiplexer.
    Camera Selection
    1. Set the LCD display to ✴SPOTor ✴MLT by repeat-
    edly pressing the F2 orF1button on the controller.
    2. Select the camera (VCR)by pressing the Function
    (F4)button on the controller.
    3. Select the desired camera by pressing the numeric
    keys, then press the SETkey.
    The selected camera picture is displayed in Single
    Spot on the selected monitor screen.
    Controlling System Accessories
    1. Lens Control
    1. Select the desired camera referring to the Camera
    Selection above.
    2. Press the FOCUSbutton to adjust the lens focus to
    obtain a sharply focused picture while observing the
    monitor.
    If you are using the specified camera with auto
    focus feature, you can adjust the lens focus auto-
    matically by pressing the AFbutton.
    3. Press the ZOOMbutton to adjust the lens zoom to
    obtain the desired picture while observing the moni-
    tor.
    Press this button to the TELEposition to optically
    bring an object closer. Pressing to the WIDEposi-
    tion has the reverse effect.4. Press the IRISbuttons to close or open the lens iris.
    Adjust the lens iris by using the buttons to obtain
    the proper picture exposure.
    By pressing both of these buttons at the same time,
    the lens iris is set to the initial factory settings.
    2. Pan/Tilt Control (Manual Operation)
    1. Select the desired camera referring to the Camera
    Selection above.
    2. Move the joystick to move the pan/tilt head in the
    desired direction.
    If the joystick is positioned in between UP and
    RIGHT, the pan/tilt head moves diagonally upwards
    and to the right.
    The moving speed of the PAN /TILT head  depends
    on the tilt of the joystick. The more you tilt it, the
    faster the head moves on the combination cameras.
    3. Pan/Tilt Control (Preset Operation)
    The following functions are only available with cam-
    eras that have preset panning functions, such as
    the Panasonic WV-BS500 or WV-CS600 series.
    1. Select the desired camera referring to the Camera
    Selection above.
    2. Press the PRE-POSIbutton, then select the preset
    number by pressing the numeric keys.
    3. Press the SETkey to move the pan/tilt head to the
    preset position.
    4. Auto Panning 
    The following function is only available when the
    specified Pan/Tilt Head is used.
    1. Select the desired camera referring to the Camera
    Selection above.
    2. Press the AUTObutton to activate the auto panning
    function. 
    						
    							-51-
    F3F4F2F1
    U01 C01 CamSet Up
    RES A.RES
    HOME/–
    AUX1
    T/L MODE
    SET UP
    PLAY REV
    CAMERA
    SET ONCAMERA
    SET OFF
    ALTHOME/–
    AUX1AUX2
    AUTO/+
    Note:The auxiliary control is not available while
    operating the zoom or pan/tilt head.
    3. Select an item by moving the joystick UP or DOWN.
    Then select the mode by moving the joystick LEFT
    or RIGHT.
    4. Press the SETkey to execute the setting or enter a
    sub menu.
    5. To return to the previous menu, press the UNITkey.
    6. Press the F3button to reset the selected function,
    or press F4to reset all functions to the initial state.
    7. Press the CAMERA SET OFFbutton to escape
    from the setup mode or menu.
    Note:Refer to the operating instructions for select-
    ed camera for more details.
    Caution:Camera addresses are important for RS-
    485 type cameras.
    1. Do not use addresses other than 1 through 16
    for individual cameras. (“17” is not allowed.)
    2. Do not set the same address for more than one
    camera in an RS-485 chain.
    6. Camera Setup
    1. Select the desired camera referring to Camera
    Selection on page 50.
    2. Press the CAMERA SET ONbutton to access the
    Camera Setup Menu. 
    The display on the LCD changes as shown below.•Simplified preset position setting
    The preset position can be set by a simplified pro-
    cedure.
    The following functions are only available with cam-
    eras that have preset panning functions, such as
    the panasonic WV-BS500 or WV-CS600 series.
    1. Press the ALTbutton while the position setting
    menu is displayed.
    2. Move the joystick controller to move the pan/tilt
    head in the desired direction.
    3. Move the FOCUSor ZOOMbutton to adjust the
    lens to obtain the desired picture.
    4. Press the ALTbutton again to restore the joy-
    stick controller’s cursor control function.
    Caution:If the camera setup is started with the but-
    tons on the camera, all future settings must also
    be made with these buttons.
    If the camera setup is started from a controller,
    all future settings must also be made from the
    controller.
    7. Auxiliary Control
    The following function is available only with a sys-
    tem that includes WV-RC100 or WV-RC150
    Receivers.
    1. Select the desired camera. Refer to the Camera
    Selection on page 50.
    2. While the ALTswitch is on, press the AUX1or
    AUX2button to enable or disable the user’s auxil-
    iary switch in the Receiver.
    ALARM CONTROL FUNCTION
    Alarm Suspension
    1. Press the RESETand EL-ZOOMbuttons simultane-
    ously for two seconds or longer to suspend the
    alarm.
    The LED on the RESET button lights up.
    RESETEL-
    ZOOM
    ALL  FS
    RESET
    2. Press the RESETbutton again to reset the alarm
    suspension.
    The LED on the RESET button goes off. 3. To cancel the auto panning function, move the joy-
    stick controller in the desired direction.
    Note:When using AUTO PANNING with combina-
    tion cameras, make sure that the LOCAL/
    REMOTE  selection is set to LOCAL at the cam-
    era site. If REMOTE is selected, the panning
    movement is retained for only one minute.
    5. Home Position Selection
    The following functions are only available with cam-
    eras that have preset panning functions, such as the
    Panasonic WV-BS500 or WV-CS600 series.
    1. Select the desired camera referring to Camera
    Selection on page 50.
    2. Press the HOMEbutton to move the camera to the
    home position. 
    						
    							-52-
    SYSTEM EXPANSION
    The system shown below is an example of the expansion capabilities of the WJ-FS616 Video Multiplexer. Up to four Video
    Multiplexers can be connected to expand the camera inputs.
    481216
    371115
    261014
    15913
    PUSH   OPEN16POWERLOCKON
    OFF
    ALARMMULTI
    SCREENMULTISCREENSELECT
    RESET SPOT SEQUENCE
    VCR
    CAMCAMERA/PRESET   P O S I T I O N
    Video
    Data RS-485
    Spot In
    Time Lapse VCR
    System Controller
    WV-CU550A
    Spot Monitor
    Live
    Main: 1-16ch
    Local: 1-16chMultiscreen Monitor
    Live 1-16ch
    Playback 1-16ch
    RS-232C/Wired
    AUXAlarm
    123456789MON CAM0System Controller for WJ-FS616 616
    F3F4F2F1
    Camera 1 -16Main Site (Unit 1)
    481216
    371115
    261014
    15913
    PUSH   OPEN16POWERLOCKON
    OFF
    ALARMMULTI
    SCREENMULTISCREENSELECT
    RESET SPOT SEQUENCE
    VCR
    CAMCAMERA/PRESET   P O S I T I O N
    Video
    Data RS-485
    Video Multiplexer
    WJ-FS616
    Time Lapse VCR
    Multiscreen Monitor
    Live 1-16ch
    Playback 1-16ch
    RS-232C/Wired
    AUXAlarm Camera 1 -16Local Site (Unit 2)
    Data
    RS-485Spot Out Video Multiplexer
    WJ-FS616
    32-Input System 
    						
    							-53-For example, press the keys shown below.
    In this example, the picture of Camera No. 15 con-
    nected to Video Multiplexer Unit 2 is displayed on
    the Spot Monitor connected to Video Multiplexer
    Unit 1.
    5. Operate the selected unit as described in the
    OPERATING PROCEDURES.
    6. Select another unit with the Numeric Keys. Then
    press the UNIT/ESCkey to activate the selected
    unit.
    Other Applications
    •Application 1
    The video signal looped through the SPOT IN con-
    nector can be displayed on the Spot Monitor.
    1. Confirm that the DAISY MODE on the SYSTEM
    SETUP menu is set to OFF.
    2. Select the unit number of the Video Multiplexer with
    the Numeric Keys. Then press the UNIT/ESCkey to
    activate the selected unit.
    3. Press the(F2)button on the controller to select the
    spot monitor.
    4. Press [ 0 ] then press the SETkey to display the
    video on the Spot Monitor looped through the SPOT
    IN connector.
    Connections
    In this type of installation, only one Video Multiplex-
    er is connected directly to the System Controller by
    a control cable.
    The rest of the Video Multiplexers are connected to
    the system Controller in a daisy-chain type connec-
    tion.
    Refer to the connections and data port settings
    shown below.
    Notes:
    •Up to four Video Multiplexers can be daisy-
    chained to the System Controller.
    •Unit numbers should be assigned in the order
    of connection, starting with the unit connected
    directly to the WV-CU550A System Controller.
    •Sequence display is limited to the cameras con-
    nected to one multiplexer unit only.
    •It is recommended to set the LOCK switch to
    the ON position while making these connec-
    tions.
    •For controlling more than 4 cameras, additional
    WV-BP6164 Data Multiplex Boards need to be
    installed in the Video Multiplexer.
    Operating Procedures
    1. Confirm that the camera and peripherals are con-
    nected correctly and firmly.
    2. Turn on the power switches of all system compo-
    nents.
    3. Confirm that the DAISY MODE parameter on the
    SYSTEM SETUP menu is set to ON.
    4. Select the unit number of the Video Multiplexer with
    the Numeric Keys. Then press the UNIT/ESCkey to
    activate the selected unit.
    TEAM.
    OFF IN OUT
    OND ATA
    SPOTOUT I N
    TEAM.
    OFF IN OUT
    OND ATA
    SPOTOUT I N
    INOUTTERMON OFF
    DATA0123456789CONTROLLER
    UNIT NO.
    1-8
    Local Site Main Site
    Video Multiplexer
    WJ-FS616 Video Multiplexer
    WJ-FS616
    123
    456
    789
    MON CAM
    UNIT/ESC SET0
    MON CAM
    UNIT/ESC2
    SET
    15
    Unit 2
    VIDEO
    Unit 1
    VIDEO 
    						
    							-54-
    Local Site
    Confirm that the REC MODE SETUP on the REC
    OUTPUT SETUP menu (page 28) is set to MODE 0.
    If another mode is set for the REC MODE SETUP,
    this application does not work properly.
    Main Site
    To display the camera pictures in the Local Site,
    operate the video multiplexer as displaying the
    playback picture.
    However same functions are enabled displaying the
    playback picture.
    •Application 2
    The camera pictures in the Local Site can be dis-
    played on the Multiscreen Monitor in the Main Site
    by connecting a coaxial cable shown below.
    Local SiteVideo Multiplexer
    REC  OUT
    PLAY   IN
    MULTISCREEN OUTVIDEO S–VIDEO
    S–VIDEO S–VIDEO VIDEO VIDEO
    Video Multiplexer Coaxial Cable
    RG-59/U less than 250m (800 ft)
    Main Site
    Multiscreen MonitorLive 1-16ch
    Playback 1-16ch 
    						
    							(02H)   (      ) – – – – – –  (      )   (3AH)   (      ) – – – (      )     (03H)
    [STX]     [Transmission Command]     [:]     [Error Code]     [ETX]
    [STX]   [Address] [;]   [Transmission Command]   [ETX] Code
    -55-
    APPENDIX
    ASCII (02H)   (      ) – – – – – – – – – – – – – – – – – (      )   (03H)
    [NAK]   [e] Code
    ASCII (15H)
    This Appendix details the elements for communication between the Video Multiplexer and the personal computer. For
    BAUD RATE, DATA BIT, STOP BIT and PARITY settings, see page 35 COM PORT SETUP menu.
    Communication Protocol
    1. Transmission Command
    The PC sends messages to operate the Multiplexer in the format shown below. Also refer to the command table shown
    later. 
    A transmission message consists of [STX], [Address], [;], [Transmission Command], and [ETX]. [Address] is expressed
    as “ADuu,”where ‘uu’ is in the range of “00” through “16” in decimal form to identify the unit number of the Video
    Multiplexer. When using the RS-232C port to communicate with the PC, [Address] and [;] can be omitted.
    2. Response Command
    The Multiplexer returns messages in reply to the PC’s messages with the following formats.
    (1) Reception completed
    When the reception was completed successfully, the Multiplexer sends back “ACK code, 06H”, followed by parameters.
    The response command is shown in the Command Table.
    Note:The Video Multiplexer returns [ACK] or [NAK] to the PC within 20 ms after the reception of [ETX] in a transmission
    message. (2) Reception error
    The Multiplexer sends back “NAK code, 15H”, followed by the parameters shown below. The Multiplexer then resets the
    reception buffer and enters waiting mode for the next message. Parameter “e” identifies the error status.
    [STX]   [Address] [;]   [Response Command]   [ETX] Code
    ASCII (02H)   (      ) – – – – – – – – – – – – – – – (      )   (03H)
    “e” value 1: Parity error
    2: Data Over error
    3: Framing error
    4: Overrun error
    5: Time Out error
    (3) Parameter error
    The Multiplexer returns “ACK code, 06H”, the transmission command that was not  processed properly for some reason,
    followed by an error code as shown below.
    Error code ER001: Command invalid
    ER002: Parameter invalid
    ER301: Command legal but out of range
    ER302: Parameter legal but out of range Code
    ASCII 
    						
    							m=0Quad m=1 7 divide
    m=2 9 divide m=3 10 divide
    m=4 13 divide   m=5 16 divide
    m=
    1No. of divisions (+)m=DNo. of divisions (−)
    Item Item
    m=0
    Manual Reset
    m=1 Auto Reset
    -56-mm=00 - 16   Camera Number
    *00=Spot Input
    mm=01 - 16   Playback CH number
    Alarm InputResponse
    Command (ASCII)
    Command Table
    (1) Operation Control
    Transmission
    Command (ASCII)Parameter (ASCII)
    Monitor Select OMS : m OMSm=0
    Spot Monitor
    m=1 Multiscreen Monitor
    m=2 Multiscreen 2 Monitor
    VCR/Camera Select OVC : m OVCm=0
    Camera Mode
    m=1 VCR Mode
    Still ON/OFF OST : m : nn OSTm=0
    Still OFF
    m=1 Still ON
    nn=00
    All video channels specify
    nn=01 - 16   Camera Number
    Multiscreen Select OTC : m OTC
    Sequence OSQ : m OSQm=0
    End Sequence
    m=1 Activate Sequence
    Electronic Zoom
    ON/OFFOZM : m OZMm=0
    Zoom OFF
    m=1 Zoom ON
    Single Spot CH Select OCS : mm OCS
    Camera & Playback Display
    Playback CH SelectOVS : mm OVS
    Alarm Reset OAL : m OAL
    Alarm Log Clear OAR OAR None Sequence Mode
    SelectOSE : m OSEm=0
    SEQ1
    m=1 SEQ2
    m=2 SEQ3
    OAI : m OAIm=0
    1CH Alarm
    :
    m=F 16CH Alarm
    (2) Mode Change
    Alarm Suspension MAD : m MADm=0
    Alarm Suspension OFF
    m=1 Alarm Suspension ON
    Lock  *1 MKL : m MKLm=0
    Lock OFF
    m=1 Lock ON
    Setup MSU : m MSUm=0
    End Setup
    m=1 Begin Setup
    Response
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII)
    Note:If a command  has no parameter value, it is processed with the value under lined in the table.
    *1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System
    Controllers. After execution of this command, only the personal computer can operate the system. 
    						
    							Item
    Item
    Response
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII) DCR : mm mm=UU       Move Upward
    mm=DD       Move Downward
    mm=RR       Move to Right
    mm=LL        Move to Left
    mm=BB       Move to lower layer
    mm=ES       Move to upper layer
    Item decision (partial)
    mm=IC        Select parameter (+)
    mm=DC       Select parameter (–)
    mm=FF        Select page
    mm=UR       Move to Upper-Right
    mm=UL       Move to Upper-Left
    mm=DR       Move to Lower-Right
    mm=DL       Move to Lower-Left
    *2 DCR
    -57- (3) Cursor Control
    Cursor Movement
    Select Parameter
    *2 The parameter valid on the main unit setup menu is:
    mm=UU, DD, RR, LL, BB, ES, FF, IC, DC
    The parameter valid for zoom position move during electronic zooming is:
    mm=UU, DD, RR, LL, UR, UL, DR, DL
    (4) Status Inquiry
    Status Inquiry QOP Table below (19 kinds) NoneResponse
    Command (ASCII) Transmission
    Command (ASCII)Parameter (ASCII) 
    						
    							No.
    -58- Examples of response
    Response Command (ASCII) Main Unit Information
    1 @mPLSNcc Single Spot (Camera)
    2 @mPLSZcc Single Spot + Electronic Zoom (Camera)
    3 @mPLSScc Single Spot + Still (Camera)
    4 @mPLSXcc Single Spot + Zoom + Still (Camera)
    5 @mPLSMLa Multi Spot (+ Still) (Camera)
    6 @mPLQNcc Spot Sequence (Camera)
    7 @mPLQMLa Multi Sequence (Camera)
    8 @mPLQZcc Spot Sequence + Zoom (Camera)
    9 @mPVSNcc Single Spot (VCR)
    10 @mPVSZcc Single Spot + Zoom (VCR)
    11 @mPVSScc Single Spot + Still (VCR)
    12 @mPVSXcc Single Spot + Zoom + Still (VCR)
    13 @mPVSMLa Multi Spot (+ Still) (VCR)
    14 @mPVQNcc Spot Sequence (VCR)
    15 @mPVQMLa Multi Sequence (VCR)
    16 @mPVQZcc Spot Sequence + Zoom (VCR)
    17 @mPRSMLa Live & VCR Display (+ Still)
    18 @mPE Setup Mode
    19 @mPX Playback through
    m=0, 1, 2 Monitor Number (0 : Spot Monitor, 1 : Multiscreen Monitor, 2 : Multiscrren 2 Monitor )
    P=N, A, D, F N : Normal    A : Alarm     D : Normal + Alarm Suspension      F : Alarm + Alarm Suspension
    cc=01 - 16 Camera Number (00 (SPOT IN) is also possible when Spot Monitor (m=0)) is selected
    a = 0 - 6 According to the number of screen divisions.
    0 : Quad    1 : 7 divide    2 : 9 divide    3 : 10 divide    4 : 13 divide    5 : 16 divide    6 : Single Spot 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Video Multiplexer Wj Fs616 Operating Instructions