Home > Panasonic > TV Video Accessories > Panasonic Video Multiplexer Wj Fs616 Operating Instructions

Panasonic Video Multiplexer Wj Fs616 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Video Multiplexer Wj Fs616 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-19-
    Connection with the Time Lapse VCR
    Connect the Time Lapse VCR as shown in the example below.
    19
    201
    ALARM/REMOTE
    37
    CAMERA
    SW  INREC  OUT PLAY   IN
    VIDEO S–VIDEO S–VIDEO VIDEO
    VIDEO IN
    CAMERA
    SW  OUTGND
    S-VIDEO
    AUDIOVIDEO OUT
    12345678910111213141516
    8 9
    28 26
    13 4 7 16
    1234
    ALARM
    IN
    COMALARM
    RESET INALARMRECOVER OUT
    5678
    ALARM
    OUT
    1 SHOT IN
    TAPE END
    OUT
    9101112
    WARNING
    OUT
    HUMID OUT
    REC REVIEWOUT
    13141516
    SERIES
    REC IN
    TIME
    ADJUST INTIMEADJUST OUT
    COMREC OUT
    SERIES
    REC OUT
    Video Multiplexer
    WJ-FS616
    Time Lapse VCR
    VCR CONTROLR2–232C
    REMOTE
    OUT
    See Notes
    • To control the VCR remotely, connect it with either
    the RS-232C Port or REMOTE OUT Connector.
    • When using the REMOTE OUT Connector for con-
    trolling the VCR remotely, reverse play and record-
    ing duration operations are disabled due to system
    designation.
    • The VCRs shown below can be controlled remotely.
    
    AG-RT600
    AG-6124
    
    AG-6730*
    AG-6740*
    AG-TL500
    (*Optional interface adapter is required) Notes:
    • Before controlling the VCR through the REMOTE
    OUT  terminal:
    1. Power up the Video Mutiplexer and the VCR
    simultaneously .
    2. Connect the video signal cable between the
    Multiplexer and the VCR.
    • The REMOTE OUT performs similarly to the AG-A11
    Remote Controller for Time Lapse VCRs. 
    						
    							-20-
    Connection with External Remote Control Switches
    Connect the switches (dry contact or open collector input) to the Alarm/Remote (ALARM/REMOTE) Control Connector
    on the rear of the Video Multiplexer as shown in the example below.
    37
    19
    20 1
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19Function
    Electronic Zoom
    Sequence
    Spot 
    Alarm/Remote Select Input
    Sequence SW for Spot Output
    Not Used
    Alarm Recover Input
    Alarm Output
    Camera 16
    Camera 14
    Ground
    Camera 11
    Camera 9
    Camera 8
    Camera 6
    Ground
    Camera 3
    Camera 1 Pin No. Designation20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37Still Picture
    VCR/Camera Select
    Multiscreen Select
    Multiscreen 
    Ground
    Alarm & SW Output
    Time Adjust / Sequence SW
    Alarm Reset Output
    Ground
    Camera 15
    Camera 13
    Camera 12
    Camera 10
    Ground
    Camera 7
    Camera 5
    Camera 4
    Camera 2 Pin No. Designation
    SW1 SW2 SW3SW16
    •
    •
    •
    •
    •
    Notes:
    • Pin#6, Sequence SW for Spot Output and the Pin#8, Alarm Recover Input can also accept DC voltages of 5 V (high
    level) and 0 V (low level) besides the switch contact signals.  The Multiplexer recognizes falling edge (high to low
    transition) as an input.  
    • Pin#5, Alarm/ Remote Select Input must be open. 
    						
    							-21- The Setup Menu provides a way for controlling func-
    tions not available through direct input.
    Displaying the SETUP MENU
    1. Confirm the camera and peripherals are connected
    correctly and securely.
    2. Turn on the power switches of all system compo-
    nents.
    3. Press the SETUP/ESCbutton for 2 seconds. 
    The SETUP MENU appears on the Spot and
    Multiscreen Monitors as shown below.
    SETUP MENU
            WJ-FS616 SETUP MENU
            ALARM SETUP *
            MULTI OUTPUT SETUP *
            SPOT OUTPUT SETUP *    
            REC/MULTI2     REC OUTPUT *
            SYSTEM SETUP *
            CAM DOWNLOAD   NO
            CAM UPLOAD     NO
            ALL RESET SELECT *
    SET  UP/ESC
    • The following buttons are valid in the SETUP menu:
    UP:Moves the cursor upward.
    DOWN:Moves the cursor downward.
    LEFT:Moves the cursor to the left, or selects the
    mode or parameter.
    RIGHT:Moves the cursor to the right, or selects the
    mode or parameter.
    SET:Executes the selections and displays a sub-
    menu for an item with the (✳) mark.
    STILL ( – ):Selects the mode or parameter.
    EL-ZOOM ( + ):Selects the mode or parameter.
    FUNCTION:Selects the next page.
    • Press the SETUP/ESCbutton to execute the cur-
    rently highlighted setting and return to the previous
    menu in the SETUP MENU.
    • To finalize the setting and return to normal viewing,
    press the SETUP/ESCbutton for 2 seconds while
    the SETUP MENU is displayed.
    Note:If alarm is activated during the setup opera-
    tion, the SETUP menu disappears and the dis-
    play returns to the normal picture. Any settings
    previously made take effect, even if the SET
    UP/ESC button was not pressed.
    LEFT
    RIGHT UP
    DOWNHOME/SET
      EL-ZOOMSTILL
    FUNCTION 
    						
    							-22-
    SETUP MENU
    Alarm SetupAlarm Recall
    Alarm Schedule
    Camera Site Alarm
    Camera Switching Signal Loss Alarm
    Alarm Display on the Monitors
    Alarm Output Duration
    Alarm Buzzer Duration
    Alarm Mode on Multiscreen Monitor
    Camera Upload
    All Reset
    Page 23
    Alarm Mode on Spot Monitor
    Dynamic Recording
    Alarm Recording Mode
    Camera Title Display
    Clock Display
    Still Display
    Border Display
    Camera Display Position
    Sequence Mode
    Camera Title Display
    Clock Display
    Camera Title Display
    Clock Display
    Dynamic Recording
    Recording Mode
    Camera Display Position
    Sequence Mode
    Clock Setup
    Clock Display Position
    Camera Title Setup
    Camera Title Display Position
    Sequence Setup
    Lock Mode
    Cable Compensation/VD2/Data
    Alarm Terminal Setup
    Playback Mode
    Data Mode
    RS-232C Mode
    Communication Port Setup
    VCR Input Select
    Daisy Mode
    Unit Address
    Camera Download 
    Multiscreen Output Menu
    Spot Output Setup
    Record Output Setup
    Multiscreen 2 Output Setup
    System Setup
    Page 25
    Page 27
    Page 27
    Page 29
    Page 30
    Page 36
    Page 37
    Page 37
    Sequence Timing (Multiscreen)
    Sequence Timing (Spot)
    Setup Menu
    As shown below, the SETUP MENU has nine main sub menus: Alarm Setup, Multiscreen Output Menu, Spot Output
    Setup, Record Output Setup, Multiscreen 2 Output Setup, System Setup, Camera Download, Camera Upload and All
    Rese.
    Six of these sub menus; Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen
    2 Output Setup and System Setup, are further divided into additional submenus. 
    						
    							-23-
    Alarm Setup Menu
    Move the cursor to ALARM SETUP on the SETUP
    MENU, then press the SET button. The ALARM
    SETUP menu appears on the monitor screen as
    shown below.
    1. Alarm Recall
    There are 100 alarm records  stored in chronologi-
    cal order in 10 pages of table.
    The tables also indicate the alarm mode.
    1. Move the cursor to ALM RECALL and press the
    SET button. The ALARM RECALL table appears
    on the monitor screen as shown below.4. To clear the alarm data, press the LEFT or
    RIGHT button to select  CLEAR where the cur-
    sor is positioned, then press the SET button.
    5. Press the SETUP/ESC button to return to the
    previous ALARM SETUP menu.
    2. Alarm Schedule
    This item lets you enable or disable the system
    alarm function.
    1. Move the cursor to the ALM SCHEDULE para-
    meter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is OFF.
    ON:Enables system alarm function.
    OFF:Disables system alarm function.
    3. To set the timer, press the SET button while the
    cursor is located on ON.
    The table lists the active alarm modes (ALM-
    MODE) as follows:
    TRM P:Interface Alarm
    CH-LOSS:Video Input Signal Loss Alarm
    SITE:Camera Site Alarm
    PC P:PC Command Alarm
    2. Press the UP button to select the next page.
    3. Press the DOWN button to back up to the previ-
    ous page.
            WJ-FS616 SETUP MENU
            ALARM SETUP *
            MULTI OUTPUT SETUP *
            SPOT OUTPUT SETUP *    
            REC/MULTI2     REC OUTPUT *
            SYSTEM SETUP *
            CAM DOWNLOAD   NO
            CAM UPLOAD     NO
            ALL RESET SELECT *
                ALARM RECALL        1 OF10
    NO.    DATE      TIME   CAM  ALM-MODE
    10. JAN  1. 97 12:00:00 16CH TRM 12
     9. DEC 12. 96  4:00:00 10CH SITE
     8. DEC 12. 96  3:00:00  8CH SITE 
     7. DEC 12. 96  2:00:00  7CH SITE 
     6. DEC 12. 96  1:00:00  6CH TRM  1
     5. DEC 11. 96 15:00:00  5CH TRM  5
     4. DEC 11. 96 14:00:00  4CH TRM 14
     3. DEC 11. 96 13:00:00  3CH TRM  7
     2. DEC 11. 96 12:00:00  2CH CH-LOSS
     1. DEC 11. 96 12:00:00  1CH CH-LOSS
     DISPLAY         (
    “)NEXT («)PRE
    CLEAR *
                  ALARM SETUP
            ALM RECALL *
            ALM SCHEDULE   ON  0:00- 0:00
            CAM SITE ALM   OFF
            SW-LOSS ALM    OFF
            ALM DISPLAY    ON
            ALM OUTPUT DUR 2SEC
            ALM BUZZER DUR 2SEC
            ALM MODE-MLT   ALM-IND
              DWELL TIME   2SEC
            ALM MODE-SPT   ALM-SPOT
            DYNAMIC REC    OFF
            ALM REC MODE   MODE0 REAL
                  ALARM SETUP
            ALM RECALL *
            ALM SCHEDULE   OFF
            CAM SITE ALM   OFF
            SW-LOSS ALM    OFF
            ALM DISPLAY    ON
            ALM OUTPUT DUR 2SEC
            ALM BUZZER DUR 2SEC
            ALM MODE-MLT   ALM-IND
              DWELL TIME   2SEC
            ALM MODE-SPT   ALM-SPOT
            DYNAMIC REC    OFF
            ALM REC MODE   MODE0 REAL
    4. Press the UP or DOWN button to move the cur-
    sor to the desired position, then adjust the time
    when the alarm is to be activated by pressing
    the LEFT or RIGHT button.
    You can set the timer to extend into the next
    day, for example, 22:00 - 6:00.
    Note:If the same time is set for start and stop
    time, the alarm is always enabled.
    5. Press the SETUP/ESC button to move the cursor
    to ON position.
    3. Camera Site Alarm
    This item lets you enable or disable the camera site
    alarm function.
    1. Move the cursor to the CAM SITE ALM parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is OFF.
    ON:Enables camera site alarm function.
    OFF:Disables camera site alarm function.
    Note:To use this function, the WV-PB6164 Data
    Multiplex Boards must be installed in the Video
    multiplexer. 
    						
    							-24-
    7. Alarm Buzzer Duration
    This item lets you select the ringing duration of the
    alarm buzzer when alarm is activated.
    1. Move the cursor to the ALM BUZZER DUR
    parameter.
    2. Select the desired duration by pressing the
    LEFT or RIGHT button. The initial factory setting
    is 2 SEC.
    OFF:Disables the alarm buzzer output.
    1SEC - 5 MIN:Selects a buzzer duration
    between 1 second and 5 minutes.
    EXT:The alarm buzzer continues to beep until
    the ALARM RESET button is pressed, or an
    external alarm recover signal is received.
    8. Alarm Mode on Multiscreen
    Monitor
    This item lets you select the mode for displaying an
    alarm on the Multiscreen Monitor.
    1. Move the cursor to the ALM MODE-MLT para-
    meter.
    2. Select the desired mode by pressing the LEFT
    or RIGHT button. The initial factory setting is
    ALM-IND mode.
    ALM-LINK:Switches screen to the camera pic-
    ture of the corresponding channel with  an
    alarm title super- imposed.
    ALM-IND: Retains the camera picture currently
    selected. An alarm title appears overlapped
    on the camera picture. If no camera is cur-
    rently selected the alarm title does not
    appear.
    3. When ALM-LINK is selected on this menu, the
    cursor can be moved to DWELL TIME.
    •Dwell Time for Alarm Sequence
    If more than one alarm is activated when ALM-LINK
    is selected, the respective camera pictures are dis-
    played on the Multiscreen Monitor in quad mode.
    From the fifth alarm on, the pictures are displayed
    sequentially in quad mode.
    This item lets you set the dwell time for the alarm
    sequence.
    1. Move the cursor to DWELL TIME parameter.
    2. Select the desired dwell time by pressing the
    LEFT or RIGHT button. The initial factory setting
    is 2 seconds.
    1SEC - 30SEC:Selects a dwell time between 1
    second and 30 seconds.
    4. Camera Switching Pulse Loss
    Alarm
    This item lets you enable or disable alarm display
    on the monitor screen when the camera switching
    pulse is lost.
    1. Move the cursor to the SW-LOSS ALM parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is OFF.
    ON:Enables alarm display on the monitor
    screen.
    OFF:Disables alarm display on the monitor
    screen.
    5. Alarm Display on the Monitors
    This item lets you enable or disable alarm display
    on the Spot and Multiscreen Monitors.
    1. Move the cursor to the ALM DISPLAY parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables alarm display on the Monitors.
    OFF:Disables alarm display on the Monitors.
    6. Alarm Output Duration
    This item lets you select the duration of alarm signal
    output.
    The alarm is automatically reset after the pro-
    grammed duration has passed.
    1. Move the cursor to the ALM OUTPUT DUR
    parameter.
    2. Select the desired duration by pressing the
    LEFT or RIGHT button. The initial factory setting
    is 2 SEC.
    1SEC - 5MIN:Selects an alarm duration
    between 1 second and 5 minutes.
    EXT:Alarm continues until the ALARM RESET
    button is pressed or the external alarm reset
    signal is received. 
    						
    							-25-
    9. Alarm Mode on Spot Monitor
    This item lets you select the mode for displaying an
    alarm on the Spot Monitor.
    1. Move the cursor to the ALM MODE-SPT para-
    meter.
    2. Select the desired mode by pressing the LEFT
    or RIGHT button. The initial factory setting is
    ALM-SPOT mode.
    ALM-SPOT:The picture of the camera that has
    activated the alarm is displayed.
    If multiple alarms are activated, the monitor
    displays the camera picture that has acti-
    vated the alarm most recent.
    ALM-IGNORE:Displays the title of alarm on the
    alarmed camera picture if that picture is
    selected on the Spot Monitor.
    10. Dynamic Recording
    In this mode, the camera picture of the channel on
    which the alarm was activated is recorded with
    more fields than in normal recording mode.
    This item lets you enable or disable dynamic
    recording mode for recording on video tape.
    1. Move the cursor to the DYNAMIC REC parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is OFF.
    ON:Enables dynamic recording.
    OFF:Disables dynamic recording.
    11. Alarm Recording Mode
    This item lets you select the mode for recording an
    alarm.
    Refer to 4. Recording Mode on page 28 for more
    details.
    1. Move the cursor to the ALM REC MODE para-
    meter.
    2. Select the desired mode by pressing the LEFT
    or RIGHT button. The initial factory setting is
    MODE 0.
    MODE 0:Normal Recording
    MODE 1-8:Time Lapse mode without camera
    switching pulse.
    MODE 9:Time lapse mode with camera switch-
    ing pulse.
    After finishing the setting, press the SETUP/ESC
    button to return to the previous SETUP MENU.
    Multiscreen Output Menu
    Move the cursor to MULTI OUTPUT SETUP on the
    SETUP MENU, then press the SET button. The
    MULTI OUTPUT SETUP menu appears on the moni-
    tor screen as shown below.
    These items let you determine the display mode of
    the Multiscreen Monitor.
    1. Camera Title Display
    This item lets you enable or disable display of the
    camera title on the Multiscreen Monitor.
    1. Move the cursor to the TITLE DISPLAY parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables display of the camera title on the
    monitor screen.
    OFF:Disables display of the camera title on the
    monitor screen.
           WJ-FS616 SETUP MENU
           ALARM SETUP *
           MULTI OUTPUT SETUP *
           SPOT OUTPUT SETUP *    
           REC/MULTI2     REC OUTPUT *
           SYSTEM SETUP *
           CAM DOWNLOAD   NO
           CAM UPLOAD     NO
           ALL RESET SELECT *
               MULTI OUTPUT SETUP 
     
            TITLE DISPLAY  ON 
            CLOCK DISPLAY  ON 
            STILL DISPLAY  ON  
            BORDER         WHITE 
            DISPLAY POSITION * 
            SEQUENCE MODE  SEQ2 
    						
    							-26-
    2. Clock Display Setting
    This item lets you enable or disable the clock dis-
    play on the Multiscreen Monitor.
    1. Move the cursor to the CLOCK DISPLAY para-
    meter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables clock display on the monitor
    screen.
    OFF:Disables clock display on the monitor
    screen.
    3. Still Display
    This item lets you enable or disable display of the
    subtitle “STIL L” on the Multiscreen Monitor when
    the channel is in the still mode.
    1. Move the cursor to the STILL DISPLAY parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables display of the subtitle “STILL” on
    the monitor screen.
    OFF:Disables display of the subtitle “STILL” on
    the monitor screen.
    4. Border Display
    This item lets you enable or disable the display of
    borders that divide the screen of the Multiscreen
    Monitor, or select a border color.
    1. Move the cursor to the BORDER parameter.
    2. Select the desired mode or color by pressing
    the LEFT or RIGHT button. The initial factory
    setting for the border color is WHITE.
    WHITE:White Border
    GRAY:Gray Border
    BLACK:Black Border
    OFF:No Border
    5. Camera Display Position Setting
    This item lets you select the position where the
    camera picture will be displayed on the Multiscreen
    Monitor.
    1. Move the cursor to DISPLAY POSITION then
    press the SET button. The table shown below
    appears on the monitor.
      1         2         3         4
       
      
      
      5         6         7         8
      
      
      
      9         10        11        12
      
      
      
      13        14        15        16
    2. Move the cursor to the desired channel number
    by pressing the UP or DOWN button.
    3. Select the numbers of the cameras to be dis-
    played by pressing the LEFT or RIGHT button.
    The pictures of the selected cameras are dis-
    played one after another on the monitor screen.
    Note:The number can be assigned directly by
    pressing the Camera Number Buttons.
    4. Press the SETUP/ESC button to return to the
    previous MULTI OUTPUT SETUP menu.
    Note:This operation only affects the camera
    display positions.
    It has no effect on the camera channel,
    recording order or sequence order.
    6. Sequence Mode
    This item lets you select the sequence pattern for
    display on the Multiscreen Monitor. 
    Refer to Sequence Setup on page 31 for more
    details.
    1. Move the cursor to the SEQUENCE MODE
    parameter.
    2. Select the desired mode by pressing the LEFT
    or RIGHT button. The initial factory setting is
    SEQ2.
    SEQ1:Spot Sequence
    SEQ2:Multi Sequence
    SEQ3:Multi Sequence
    After finishing the setting, press the SETUP/ESC
    button to return to the previous SETUP MENU. 
    						
    							-27- Move the cursor to SPOT OUTPUT SETUP on the
    SETUP MENU, then press the SET button. The SPOT
    OUTPUT SETUP menu appears on the monitor
    screen as shown below.
    These items let you determine the display mode of
    the Spot Monitor.
               SPOT OUTPUT SETUP
            TITLE DISPLAY  ON
            CLOCK DISPLAY  ON
    1. Camera Title Display
    This item lets you enable or disable display of the
    camera title on the Spot Monitor.
    1. Move the cursor to the TITLE DISPLAY parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables display of the camera title on the
    Spot Monitor screen.
    OFF:Disables display of the camera title on the
    Spot Monitor screen.
    2. Clock Display
    This item lets you enable or disable the clock dis-
    play on the Spot Monitor.
    1. Move the cursor to the CLOCK DISPLAY para-
    meter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
           WJ-FS616 SETUP MENU
           ALARM SETUP *
           MULTI OUTPUT SETUP *
           SPOT OUTPUT SETUP *    
           REC/MULTI2     REC OUTPUT *
           SYSTEM SETUP *
           CAM DOWNLOAD   NO
           CAM UPLOAD     NO
           ALL RESET SELECT *
    Spot Output Setup
    1. Move the cursor to the REC/MULTI2 parameter
    on the SETUP MENU.
    2. Select REC OUTPUT by pressing the LEFT or
    RIGHT button, then press the SET button. The
    REC OUTPUT SETUP menu appears on the
    monitor screen shown below.
    These items let you determine the mode for record-
    ing on the Time Lapse VCR.
           WJ-FS616 SETUP MENU
           ALARM SETUP *
           MULTI OUTPUT SETUP *
           SPOT OUTPUT SETUP *    
           REC/MULTI2     REC OUTPUT *
           SYSTEM SETUP *
           CAM DOWNLOAD   NO
           CAM UPLOAD     NO
           ALL RESET SELECT *
    ON:Enables clock display on the Spot Monitor
    screen.
    OFF:Disables clock display on the Spot Moni-
    tor screen.
    After finishing the setting, press the SETUP/ESC
    button to return to the previous SETUP MENU.
    Record Output Setup
                REC OUTPUT SETUP
            TITLE DISPLAY  ON
            CLOCK DISPLAY  ON
            DYNAMIC REC SETUP *
            REC MODE SETUP *
    1. Camera Title Display
    This item lets you enable or disable  recording of the
    camera title on the VCR.
    1. Move the cursor to the TITLE DISPLAY parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables recording of the camera title on the
    VCR.
    OFF:Disables recording of the camera title on
    the VCR. 
    						
    							-28-
    2. Clock Display
    This item lets you enable or disable recording of the
    clock display on the VCR.
    1. Move the cursor to the CLOCK DISPLAY para-
    meter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button. The initial factory setting is ON.
    ON:Enables recording of clock display on the
    VCR.
    OFF:Disables recording of clock display on the
    VCR.
    3. Dynamic Recording
    This item lets you select the cameras for dynamic
    recording mode in non-alarm condition.
    If five or more cameras are connected to the Video
    Multiplexer, the channels selected for dynamic
    recording are recorded with priority.
    1. Move the cursor to DYNAMIC REC SETUP then
    press the SET button. The DYNAMIC REC
    SETUP menu appears on the monitor screen as
    shown below.
               DYNAMIC REC SETUP 
     
           CAM PRIORITY    CAM PRIORITY 
           1CH   OFF       9CH   OFF
           2CH   OFF      10CH   OFF 
           3CH   OFF      11CH   OFF 
           4CH   OFF      12CH   OFF 
           5CH   OFF      13CH   OFF 
           6CH   OFF      14CH   OFF 
           7CH   OFF      15CH   OFF  
           8CH   OFF      16CH   OFF 
         
    4. Recording Mode
    Move the cursor to REC MODE SETUP, then press
    the SET button. The REC MODE SETUP menu
    appears on the monitor screen as shown below.
    2. Move the cursor to the desired camera number
    to be recorded with dynamic recording in the
    PRIORITY area by pressing the Derection Arrow
    Buttons.
    3. Select ON by pressing the Increment (+)  or
    Decrement (–) button. The initial factory setting
    is OFF.
    4. Repeat the above procedures 2 to 3 to set other
    cameras.
    Note:It is recommended to select up to 2 cam-
    eras.
    5. Press the SETUP/ESC button to execute the set-
    ting and return to the REC OUTPUT SETUP
    menu.
    Note:Recording is not done in dynamic recording
    mode when EXT4 is selected for MODE 9 in the
    recording mode setup shown below.
                 REC MODE SETUP 
     
        MODE 0             0123456789 
                           ABCDEFGHIJK 
        MODE0    1  REAL   LMNOPQRSTUV 
        MODE1  ---  ----   WXYZ 
        MODE2  ---  ----   abcdefghijk
        MODE3  ---  ----   lmnopqrstuv 
        MODE4  ---  ----   wxyz  
        MODE5  ---  ----   
    ¤=?#&()*
        MODE6  ---  ----   +,-./:;E 
        MODE7  ---  ----    
        MODE8  ---  ----  
        MODE9 EXT1  -EXT   
       
    Current REC MODE
    REC MODE Title
    REC MODE Parameter
    Recording Mode 
    1. Move the cursor to the MODE, parameter.
    2. Select a mode number by pressing the LEFT or
    RIGHT button. The initial factory setting is “0”.
    MODE 0:Normal recording
    MODE 1 - 8:Time Lapse Mode (VCR without
    camera switching pulse)
    MODE 9:Time Lapse Mode (VCR with camera
    switching pulse)
    Note:To select MODE 1 - 8, you must first com-
    plete the settings described below.
    Recording Mode Setting Details
    You can assign the camera switching timing to any
    one of MODE1 to MODE8 when using the VCR with-
    out camera switching pulse.
    1. Move the cursor to the desired MODE number
    to be assigned by pressing the UP or DOWN
    button.
    2. Press the SET button to move the cursor to the
    switching timing area.
    Note:The cursor does not move to this area
    when MODE 0 is selected in this table.
    3. Select the desired switching timing indicated as
    the field interval (4 to 999) by pressing the LEFT
    or RIGHT button.
    Notes:
    •Numbers can also be input directly with the
    Camera Number Buttons (1 - 10).
    •Refer to the operating instructions of the
    VCR for switching timing.
    When MODE9 is selected in this table, select
    EXT1 or EXT4 by pressing the LEFT or RIGHT
    button.
    EXT1:Enables spot picture recording on the
    VCR.
    EXT4:Enables quad picture recording on the
    VCR. 
    						
    All Panasonic manuals Comments (0)