-19- Connection with the Time Lapse VCR Connect the Time Lapse VCR as shown in the example below. 19 201 ALARM/REMOTE 37 CAMERA SW INREC OUT PLAY IN VIDEO S–VIDEO S–VIDEO VIDEO VIDEO IN CAMERA SW OUTGND S-VIDEO AUDIOVIDEO OUT 12345678910111213141516 8 9 28 26 13 4 7 16 1234 ALARM IN COMALARM RESET INALARMRECOVER OUT 5678 ALARM OUT 1 SHOT IN TAPE END OUT 9101112 WARNING OUT HUMID OUT REC REVIEWOUT 13141516 SERIES REC IN TIME ADJUST INTIMEADJUST OUT COMREC OUT SERIES REC OUT Video Multiplexer WJ-FS616 Time Lapse VCR VCR CONTROLR2–232C REMOTE OUT See Notes • To control the VCR remotely, connect it with either the RS-232C Port or REMOTE OUT Connector. • When using the REMOTE OUT Connector for con- trolling the VCR remotely, reverse play and record- ing duration operations are disabled due to system designation. • The VCRs shown below can be controlled remotely. AG-RT600 AG-6124 AG-6730* AG-6740* AG-TL500 (*Optional interface adapter is required) Notes: • Before controlling the VCR through the REMOTE OUT terminal: 1. Power up the Video Mutiplexer and the VCR simultaneously . 2. Connect the video signal cable between the Multiplexer and the VCR. • The REMOTE OUT performs similarly to the AG-A11 Remote Controller for Time Lapse VCRs.
-20- Connection with External Remote Control Switches Connect the switches (dry contact or open collector input) to the Alarm/Remote (ALARM/REMOTE) Control Connector on the rear of the Video Multiplexer as shown in the example below. 37 19 20 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Function Electronic Zoom Sequence Spot Alarm/Remote Select Input Sequence SW for Spot Output Not Used Alarm Recover Input Alarm Output Camera 16 Camera 14 Ground Camera 11 Camera 9 Camera 8 Camera 6 Ground Camera 3 Camera 1 Pin No. Designation20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37Still Picture VCR/Camera Select Multiscreen Select Multiscreen Ground Alarm & SW Output Time Adjust / Sequence SW Alarm Reset Output Ground Camera 15 Camera 13 Camera 12 Camera 10 Ground Camera 7 Camera 5 Camera 4 Camera 2 Pin No. Designation SW1 SW2 SW3SW16 • • • • • Notes: • Pin#6, Sequence SW for Spot Output and the Pin#8, Alarm Recover Input can also accept DC voltages of 5 V (high level) and 0 V (low level) besides the switch contact signals. The Multiplexer recognizes falling edge (high to low transition) as an input. • Pin#5, Alarm/ Remote Select Input must be open.
-21- The Setup Menu provides a way for controlling func- tions not available through direct input. Displaying the SETUP MENU 1. Confirm the camera and peripherals are connected correctly and securely. 2. Turn on the power switches of all system compo- nents. 3. Press the SETUP/ESCbutton for 2 seconds. The SETUP MENU appears on the Spot and Multiscreen Monitors as shown below. SETUP MENU WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * SET UP/ESC • The following buttons are valid in the SETUP menu: UP:Moves the cursor upward. DOWN:Moves the cursor downward. LEFT:Moves the cursor to the left, or selects the mode or parameter. RIGHT:Moves the cursor to the right, or selects the mode or parameter. SET:Executes the selections and displays a sub- menu for an item with the (✳) mark. STILL ( – ):Selects the mode or parameter. EL-ZOOM ( + ):Selects the mode or parameter. FUNCTION:Selects the next page. • Press the SETUP/ESCbutton to execute the cur- rently highlighted setting and return to the previous menu in the SETUP MENU. • To finalize the setting and return to normal viewing, press the SETUP/ESCbutton for 2 seconds while the SETUP MENU is displayed. Note:If alarm is activated during the setup opera- tion, the SETUP menu disappears and the dis- play returns to the normal picture. Any settings previously made take effect, even if the SET UP/ESC button was not pressed. LEFT RIGHT UP DOWNHOME/SET EL-ZOOMSTILL FUNCTION
-22- SETUP MENU Alarm SetupAlarm Recall Alarm Schedule Camera Site Alarm Camera Switching Signal Loss Alarm Alarm Display on the Monitors Alarm Output Duration Alarm Buzzer Duration Alarm Mode on Multiscreen Monitor Camera Upload All Reset Page 23 Alarm Mode on Spot Monitor Dynamic Recording Alarm Recording Mode Camera Title Display Clock Display Still Display Border Display Camera Display Position Sequence Mode Camera Title Display Clock Display Camera Title Display Clock Display Dynamic Recording Recording Mode Camera Display Position Sequence Mode Clock Setup Clock Display Position Camera Title Setup Camera Title Display Position Sequence Setup Lock Mode Cable Compensation/VD2/Data Alarm Terminal Setup Playback Mode Data Mode RS-232C Mode Communication Port Setup VCR Input Select Daisy Mode Unit Address Camera Download Multiscreen Output Menu Spot Output Setup Record Output Setup Multiscreen 2 Output Setup System Setup Page 25 Page 27 Page 27 Page 29 Page 30 Page 36 Page 37 Page 37 Sequence Timing (Multiscreen) Sequence Timing (Spot) Setup Menu As shown below, the SETUP MENU has nine main sub menus: Alarm Setup, Multiscreen Output Menu, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup, System Setup, Camera Download, Camera Upload and All Rese. Six of these sub menus; Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup and System Setup, are further divided into additional submenus.
-23- Alarm Setup Menu Move the cursor to ALARM SETUP on the SETUP MENU, then press the SET button. The ALARM SETUP menu appears on the monitor screen as shown below. 1. Alarm Recall There are 100 alarm records stored in chronologi- cal order in 10 pages of table. The tables also indicate the alarm mode. 1. Move the cursor to ALM RECALL and press the SET button. The ALARM RECALL table appears on the monitor screen as shown below.4. To clear the alarm data, press the LEFT or RIGHT button to select CLEAR where the cur- sor is positioned, then press the SET button. 5. Press the SETUP/ESC button to return to the previous ALARM SETUP menu. 2. Alarm Schedule This item lets you enable or disable the system alarm function. 1. Move the cursor to the ALM SCHEDULE para- meter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is OFF. ON:Enables system alarm function. OFF:Disables system alarm function. 3. To set the timer, press the SET button while the cursor is located on ON. The table lists the active alarm modes (ALM- MODE) as follows: TRM P:Interface Alarm CH-LOSS:Video Input Signal Loss Alarm SITE:Camera Site Alarm PC P:PC Command Alarm 2. Press the UP button to select the next page. 3. Press the DOWN button to back up to the previ- ous page. WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * ALARM RECALL 1 OF10 NO. DATE TIME CAM ALM-MODE 10. JAN 1. 97 12:00:00 16CH TRM 12 9. DEC 12. 96 4:00:00 10CH SITE 8. DEC 12. 96 3:00:00 8CH SITE 7. DEC 12. 96 2:00:00 7CH SITE 6. DEC 12. 96 1:00:00 6CH TRM 1 5. DEC 11. 96 15:00:00 5CH TRM 5 4. DEC 11. 96 14:00:00 4CH TRM 14 3. DEC 11. 96 13:00:00 3CH TRM 7 2. DEC 11. 96 12:00:00 2CH CH-LOSS 1. DEC 11. 96 12:00:00 1CH CH-LOSS DISPLAY ( “)NEXT («)PRE CLEAR * ALARM SETUP ALM RECALL * ALM SCHEDULE ON 0:00- 0:00 CAM SITE ALM OFF SW-LOSS ALM OFF ALM DISPLAY ON ALM OUTPUT DUR 2SEC ALM BUZZER DUR 2SEC ALM MODE-MLT ALM-IND DWELL TIME 2SEC ALM MODE-SPT ALM-SPOT DYNAMIC REC OFF ALM REC MODE MODE0 REAL ALARM SETUP ALM RECALL * ALM SCHEDULE OFF CAM SITE ALM OFF SW-LOSS ALM OFF ALM DISPLAY ON ALM OUTPUT DUR 2SEC ALM BUZZER DUR 2SEC ALM MODE-MLT ALM-IND DWELL TIME 2SEC ALM MODE-SPT ALM-SPOT DYNAMIC REC OFF ALM REC MODE MODE0 REAL 4. Press the UP or DOWN button to move the cur- sor to the desired position, then adjust the time when the alarm is to be activated by pressing the LEFT or RIGHT button. You can set the timer to extend into the next day, for example, 22:00 - 6:00. Note:If the same time is set for start and stop time, the alarm is always enabled. 5. Press the SETUP/ESC button to move the cursor to ON position. 3. Camera Site Alarm This item lets you enable or disable the camera site alarm function. 1. Move the cursor to the CAM SITE ALM parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is OFF. ON:Enables camera site alarm function. OFF:Disables camera site alarm function. Note:To use this function, the WV-PB6164 Data Multiplex Boards must be installed in the Video multiplexer.
-24- 7. Alarm Buzzer Duration This item lets you select the ringing duration of the alarm buzzer when alarm is activated. 1. Move the cursor to the ALM BUZZER DUR parameter. 2. Select the desired duration by pressing the LEFT or RIGHT button. The initial factory setting is 2 SEC. OFF:Disables the alarm buzzer output. 1SEC - 5 MIN:Selects a buzzer duration between 1 second and 5 minutes. EXT:The alarm buzzer continues to beep until the ALARM RESET button is pressed, or an external alarm recover signal is received. 8. Alarm Mode on Multiscreen Monitor This item lets you select the mode for displaying an alarm on the Multiscreen Monitor. 1. Move the cursor to the ALM MODE-MLT para- meter. 2. Select the desired mode by pressing the LEFT or RIGHT button. The initial factory setting is ALM-IND mode. ALM-LINK:Switches screen to the camera pic- ture of the corresponding channel with an alarm title super- imposed. ALM-IND: Retains the camera picture currently selected. An alarm title appears overlapped on the camera picture. If no camera is cur- rently selected the alarm title does not appear. 3. When ALM-LINK is selected on this menu, the cursor can be moved to DWELL TIME. •Dwell Time for Alarm Sequence If more than one alarm is activated when ALM-LINK is selected, the respective camera pictures are dis- played on the Multiscreen Monitor in quad mode. From the fifth alarm on, the pictures are displayed sequentially in quad mode. This item lets you set the dwell time for the alarm sequence. 1. Move the cursor to DWELL TIME parameter. 2. Select the desired dwell time by pressing the LEFT or RIGHT button. The initial factory setting is 2 seconds. 1SEC - 30SEC:Selects a dwell time between 1 second and 30 seconds. 4. Camera Switching Pulse Loss Alarm This item lets you enable or disable alarm display on the monitor screen when the camera switching pulse is lost. 1. Move the cursor to the SW-LOSS ALM parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is OFF. ON:Enables alarm display on the monitor screen. OFF:Disables alarm display on the monitor screen. 5. Alarm Display on the Monitors This item lets you enable or disable alarm display on the Spot and Multiscreen Monitors. 1. Move the cursor to the ALM DISPLAY parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables alarm display on the Monitors. OFF:Disables alarm display on the Monitors. 6. Alarm Output Duration This item lets you select the duration of alarm signal output. The alarm is automatically reset after the pro- grammed duration has passed. 1. Move the cursor to the ALM OUTPUT DUR parameter. 2. Select the desired duration by pressing the LEFT or RIGHT button. The initial factory setting is 2 SEC. 1SEC - 5MIN:Selects an alarm duration between 1 second and 5 minutes. EXT:Alarm continues until the ALARM RESET button is pressed or the external alarm reset signal is received.
-25- 9. Alarm Mode on Spot Monitor This item lets you select the mode for displaying an alarm on the Spot Monitor. 1. Move the cursor to the ALM MODE-SPT para- meter. 2. Select the desired mode by pressing the LEFT or RIGHT button. The initial factory setting is ALM-SPOT mode. ALM-SPOT:The picture of the camera that has activated the alarm is displayed. If multiple alarms are activated, the monitor displays the camera picture that has acti- vated the alarm most recent. ALM-IGNORE:Displays the title of alarm on the alarmed camera picture if that picture is selected on the Spot Monitor. 10. Dynamic Recording In this mode, the camera picture of the channel on which the alarm was activated is recorded with more fields than in normal recording mode. This item lets you enable or disable dynamic recording mode for recording on video tape. 1. Move the cursor to the DYNAMIC REC parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is OFF. ON:Enables dynamic recording. OFF:Disables dynamic recording. 11. Alarm Recording Mode This item lets you select the mode for recording an alarm. Refer to 4. Recording Mode on page 28 for more details. 1. Move the cursor to the ALM REC MODE para- meter. 2. Select the desired mode by pressing the LEFT or RIGHT button. The initial factory setting is MODE 0. MODE 0:Normal Recording MODE 1-8:Time Lapse mode without camera switching pulse. MODE 9:Time lapse mode with camera switch- ing pulse. After finishing the setting, press the SETUP/ESC button to return to the previous SETUP MENU. Multiscreen Output Menu Move the cursor to MULTI OUTPUT SETUP on the SETUP MENU, then press the SET button. The MULTI OUTPUT SETUP menu appears on the moni- tor screen as shown below. These items let you determine the display mode of the Multiscreen Monitor. 1. Camera Title Display This item lets you enable or disable display of the camera title on the Multiscreen Monitor. 1. Move the cursor to the TITLE DISPLAY parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables display of the camera title on the monitor screen. OFF:Disables display of the camera title on the monitor screen. WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * MULTI OUTPUT SETUP TITLE DISPLAY ON CLOCK DISPLAY ON STILL DISPLAY ON BORDER WHITE DISPLAY POSITION * SEQUENCE MODE SEQ2
-26- 2. Clock Display Setting This item lets you enable or disable the clock dis- play on the Multiscreen Monitor. 1. Move the cursor to the CLOCK DISPLAY para- meter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables clock display on the monitor screen. OFF:Disables clock display on the monitor screen. 3. Still Display This item lets you enable or disable display of the subtitle “STIL L” on the Multiscreen Monitor when the channel is in the still mode. 1. Move the cursor to the STILL DISPLAY parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables display of the subtitle “STILL” on the monitor screen. OFF:Disables display of the subtitle “STILL” on the monitor screen. 4. Border Display This item lets you enable or disable the display of borders that divide the screen of the Multiscreen Monitor, or select a border color. 1. Move the cursor to the BORDER parameter. 2. Select the desired mode or color by pressing the LEFT or RIGHT button. The initial factory setting for the border color is WHITE. WHITE:White Border GRAY:Gray Border BLACK:Black Border OFF:No Border 5. Camera Display Position Setting This item lets you select the position where the camera picture will be displayed on the Multiscreen Monitor. 1. Move the cursor to DISPLAY POSITION then press the SET button. The table shown below appears on the monitor. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2. Move the cursor to the desired channel number by pressing the UP or DOWN button. 3. Select the numbers of the cameras to be dis- played by pressing the LEFT or RIGHT button. The pictures of the selected cameras are dis- played one after another on the monitor screen. Note:The number can be assigned directly by pressing the Camera Number Buttons. 4. Press the SETUP/ESC button to return to the previous MULTI OUTPUT SETUP menu. Note:This operation only affects the camera display positions. It has no effect on the camera channel, recording order or sequence order. 6. Sequence Mode This item lets you select the sequence pattern for display on the Multiscreen Monitor. Refer to Sequence Setup on page 31 for more details. 1. Move the cursor to the SEQUENCE MODE parameter. 2. Select the desired mode by pressing the LEFT or RIGHT button. The initial factory setting is SEQ2. SEQ1:Spot Sequence SEQ2:Multi Sequence SEQ3:Multi Sequence After finishing the setting, press the SETUP/ESC button to return to the previous SETUP MENU.
-27- Move the cursor to SPOT OUTPUT SETUP on the SETUP MENU, then press the SET button. The SPOT OUTPUT SETUP menu appears on the monitor screen as shown below. These items let you determine the display mode of the Spot Monitor. SPOT OUTPUT SETUP TITLE DISPLAY ON CLOCK DISPLAY ON 1. Camera Title Display This item lets you enable or disable display of the camera title on the Spot Monitor. 1. Move the cursor to the TITLE DISPLAY parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables display of the camera title on the Spot Monitor screen. OFF:Disables display of the camera title on the Spot Monitor screen. 2. Clock Display This item lets you enable or disable the clock dis- play on the Spot Monitor. 1. Move the cursor to the CLOCK DISPLAY para- meter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * Spot Output Setup 1. Move the cursor to the REC/MULTI2 parameter on the SETUP MENU. 2. Select REC OUTPUT by pressing the LEFT or RIGHT button, then press the SET button. The REC OUTPUT SETUP menu appears on the monitor screen shown below. These items let you determine the mode for record- ing on the Time Lapse VCR. WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * ON:Enables clock display on the Spot Monitor screen. OFF:Disables clock display on the Spot Moni- tor screen. After finishing the setting, press the SETUP/ESC button to return to the previous SETUP MENU. Record Output Setup REC OUTPUT SETUP TITLE DISPLAY ON CLOCK DISPLAY ON DYNAMIC REC SETUP * REC MODE SETUP * 1. Camera Title Display This item lets you enable or disable recording of the camera title on the VCR. 1. Move the cursor to the TITLE DISPLAY parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables recording of the camera title on the VCR. OFF:Disables recording of the camera title on the VCR.
-28- 2. Clock Display This item lets you enable or disable recording of the clock display on the VCR. 1. Move the cursor to the CLOCK DISPLAY para- meter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables recording of clock display on the VCR. OFF:Disables recording of clock display on the VCR. 3. Dynamic Recording This item lets you select the cameras for dynamic recording mode in non-alarm condition. If five or more cameras are connected to the Video Multiplexer, the channels selected for dynamic recording are recorded with priority. 1. Move the cursor to DYNAMIC REC SETUP then press the SET button. The DYNAMIC REC SETUP menu appears on the monitor screen as shown below. DYNAMIC REC SETUP CAM PRIORITY CAM PRIORITY 1CH OFF 9CH OFF 2CH OFF 10CH OFF 3CH OFF 11CH OFF 4CH OFF 12CH OFF 5CH OFF 13CH OFF 6CH OFF 14CH OFF 7CH OFF 15CH OFF 8CH OFF 16CH OFF 4. Recording Mode Move the cursor to REC MODE SETUP, then press the SET button. The REC MODE SETUP menu appears on the monitor screen as shown below. 2. Move the cursor to the desired camera number to be recorded with dynamic recording in the PRIORITY area by pressing the Derection Arrow Buttons. 3. Select ON by pressing the Increment (+) or Decrement (–) button. The initial factory setting is OFF. 4. Repeat the above procedures 2 to 3 to set other cameras. Note:It is recommended to select up to 2 cam- eras. 5. Press the SETUP/ESC button to execute the set- ting and return to the REC OUTPUT SETUP menu. Note:Recording is not done in dynamic recording mode when EXT4 is selected for MODE 9 in the recording mode setup shown below. REC MODE SETUP MODE 0 0123456789 ABCDEFGHIJK MODE0 1 REAL LMNOPQRSTUV MODE1 --- ---- WXYZ MODE2 --- ---- abcdefghijk MODE3 --- ---- lmnopqrstuv MODE4 --- ---- wxyz MODE5 --- ---- ¤=?#&()* MODE6 --- ---- +,-./:;E MODE7 --- ---- MODE8 --- ---- MODE9 EXT1 -EXT Current REC MODE REC MODE Title REC MODE Parameter Recording Mode 1. Move the cursor to the MODE, parameter. 2. Select a mode number by pressing the LEFT or RIGHT button. The initial factory setting is “0”. MODE 0:Normal recording MODE 1 - 8:Time Lapse Mode (VCR without camera switching pulse) MODE 9:Time Lapse Mode (VCR with camera switching pulse) Note:To select MODE 1 - 8, you must first com- plete the settings described below. Recording Mode Setting Details You can assign the camera switching timing to any one of MODE1 to MODE8 when using the VCR with- out camera switching pulse. 1. Move the cursor to the desired MODE number to be assigned by pressing the UP or DOWN button. 2. Press the SET button to move the cursor to the switching timing area. Note:The cursor does not move to this area when MODE 0 is selected in this table. 3. Select the desired switching timing indicated as the field interval (4 to 999) by pressing the LEFT or RIGHT button. Notes: •Numbers can also be input directly with the Camera Number Buttons (1 - 10). •Refer to the operating instructions of the VCR for switching timing. When MODE9 is selected in this table, select EXT1 or EXT4 by pressing the LEFT or RIGHT button. EXT1:Enables spot picture recording on the VCR. EXT4:Enables quad picture recording on the VCR.