Home > Panasonic > TV Video Accessories > Panasonic Video Multiplexer Wj Fs616 Operating Instructions

Panasonic Video Multiplexer Wj Fs616 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Video Multiplexer Wj Fs616 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-29- 4. Press the SET button to move the cursor to the
    recording mode title area. The square cursor
    appears in the character table.
    5. To select a character, move the cursor on the
    desired character in the table by pressing the
    Direction Arrow buttons.
    6. Press the SET button to pick up the character
    and place it in the title area.
    7. Repeat the above procedures 5 to 6 to set the
    title.
    8. If a wrong character is selected, press the
    Increment (+) or Decrement (–) button to move
    the cursor in the title area.
    Note:Press the (+) button to move the cursor to
    the right, or press the (–) button to move the
    cursor to the left.
    Then press the SET button to overwrite the
    character with the character selected from
    the table.
    9. Press the SETUP/ESC button. The cursor moves
    to MODE number.
    10. Repeat the above procedures 1 to 9 to assign
    the other MODE numbers.
    11. After completing the setting, press the SET
    UP/ESC button to return to the REC OUTPUT
    SETUP menu.
    After finishing the setting, press the SETUP/ESC
    button to return to the previous SETUP MENU.
    Multiscreen 2 Output Setup
    These items let you select the mode when connect-
    ing the Record Output (REC OUT) to the monitor for
    Multiscreen 2 Monitor.
           WJ-FS616 SETUP MENU
           ALARM SETUP *
           MULTI OUTPUT SETUP *
           SPOT OUTPUT SETUP *    
           REC/MULTI2     MULTI2 OUTPUT *
           SYSTEM SETUP *
           CAM DOWNLOAD   NO
           CAM UPLOAD     NO
           ALL RESET SELECT *
    1. Move the cursor to the REC/MULTI2 parameter
    on the SETUP MENU.
    2. Select MULTI2 OUTPUT by pressing the LEFT
    or RIGHT button, then press the SET button.
    The MULTI2 OUTPUT SETUP menu appears on
    the monitor screen as shown below.
              MULTI2 OUTPUT SETUP
            DISPLAY POSITION *
            SEQUENCE MODE  SEQ2
    1. Camera Display Position
    This item lets you select the position where the
    camera picture will be displayed on the Multiscreen
    Monitor 2.
    1. Move the cursor to DISPLAY POSITION, then
    press the SET button. The table shown below
    appears on the monitor.
      1         2         3         4
       
      
      
      5         6         7         8
      
      
      
      9         10        11        12
      
      
      
      13        14        15        16
    2. Move the cursor to the desired channel number
    by pressing the UP or DOWN button.
    3. Select the numbers of the cameras to be dis-
    played by pressing the LEFT or RIGHT button.
    The pictures of the selected cameras are dis-
    played one after another on the monitor screen.
    Note:Numbers can also be input directly with
    the Camera Number Buttons (1 - 10).
    4. After completing the setting, press the SET
    UP/ESC button to return to the previous MULTI
    2 OUTPUT SETUP menu.
    Note:This operation only affects the camera
    display positions.
    It has no effect on the camera channel,
    recording order or sequence order.
    2. Sequence Mode
    This item lets you select the sequence pattern for
    display on the Multiscreen Monitor 2.
    Refer to Sequence Setup on page 31 for more
    details.
    1. Move the cursor to the SEQUENCE MODE
    parameter.
    2. Select the desired mode by pressing the LEFT
    or RIGHT button. The initial factory setting is
    SEQ2.
    SEQ1:Spot Sequence
    SEQ2:Multi Sequence
    SEQ3:Multi Sequence
    After finishing the setting, press the SETUP/ESC
    button to return to the previous SETUP MENU. 
    						
    							-30-
    System Setup
    Move the cursor to SYSTEM SETUP on the SETUP
    MENU, then press the SET button. The SYSTEM
    SETUP menu appears on the monitor screen as
    shown below.
    Press the FUNCTION button to display the next
    page. Press this button again to return to the previ-
    ous page.
    1. Clock Setup
    This item lets you set the current time and date.
    1. Move the cursor to CLOCK SETUP, then press
    the SET button to move the cursor to the editing
    area.
    2. Move the cursor to the area you want to edit by
    pressing the UP or DOWN button, then select
    the month or number by pressing the LEFT or
    RIGHT button.
    3. After finishing the setting, press the SETUP/
    ESC button to move the cursor to CLOCK
    SETUP.
    Note:The date and time are updated when the
    SETUP/ESC button is pressed.
                  SYSTEM SETUP      1 OF 2
            CLOCK SETUP    JAN 1.97  0:00
            CLOCK POSITION *
            TITLE SETUP *
            TITLE POSITION *
            SEQUENCE SETUP SEQ1 *
            SEQ TIMING-MLT INT(TIME-ADJ)
            SEQ TIMING-SPT INT
            LOCK MODE      ALL
                  SYSTEM SETUP      2 OF 2
            CABLE COMP/VD2/DATA SETUP *
            ALM TERMINAL SETUP *
            PLAYBACK MODE  FIELD
            DATA MODE      CU550A
            RS-232C MODE   VCR
            COM PORT SETUP *      
            VCR IN SELECT  VIDEO
            DAISY MODE     OFF
            UNIT ADDR.SET  1
            DEC11.96 12:00:00 
      
                    
                     
     
     
     
     
                  CAMTITLE
     
     
     
      
      
       
           WJ-FS616 SETUP MENU
           ALARM SETUP *
           MULTI OUTPUT SETUP *
           SPOT OUTPUT SETUP *    
           REC/MULTI2     MULTI2 OUTPUT *
           SYSTEM SETUP *
           CAM DOWNLOAD   NO
           CAM UPLOAD     NO
           ALL RESET SELECT *
                  TITLE SETUP       1 OF 2 
     
         1CH 1-------      0123456789 
         2CH 2-------      ABCDEFGHIJK 
         3CH 3-------      LMNOPQRSTUV 
         4CH 4-------      WXYZ 
         5CH 5-------      abcdefghijk
         6CH 6-------      imnopqrstuv 
         7CH 7-------      wxyz 
         8CH 8-------      
    ¤=?#&()*
                           +,-./:;E 
           
         
                         
    @
                  TITLE SETUP       2 OF 2 
     
         9CH 9-------      0123456789 
        10CH 10------      ABCDEFGHIJK 
        11CH 11------      LMNOPQRSTUV 
        12CH 12------      WXYZ 
        13CH 13------      abcdefghijk
        14CH 14------      imnopqrstuv 
        15CH 15------      wxyz 
        16CH 16------      
    ¤=?#&()*
                           +,-./:;E 
           
         
                         
    @
    2. Clock Display Position
    This item lets you select the position where the
    clock will be displayed on the monitor screen.
    1. Move the cursor to CLOCK POSITION, then
    press the SET button. The position setting menu
    appears on the monitor screen as show below.
    2. Move the clock position by pressing the
    Direction Arrow Buttons.
    Note:In the Multiscreen display with display of
    the Record out signals, the clock display is
    shifted one line from the preset position if
    the Camera Title and the Clock are preset
    to the same position.
    3. Press the SETUP/ESC button to execute the
    selection and return to the previous SYSTEM
    SETUP menu.
    3. Camera Title Setup
    This item lets you edit the camera title to be dis-
    played on the monitor screen.
    Up to 8 alphanumeric characters can be displayed
    on the monitor.
    1. Move the cursor to TITLE SETUP, then press the
    SET button.
    The TITLE SETUP menu appears on the monitor
    screen as shown below. 
    						
    							-31-
           SEQ1(SPOT-SEQUENCE)SETUP 1 OF 2
         AUTO SKIP  OFF
         DWELL TIME 2SEC
     STEP CAM PRE TIME   STEP CAM PRE TIME
       1  1CH  -  2SEC     9  9CH  -  2SEC
       2  2CH  -  2SEC    10 10CH  -  2SEC
       3  3CH  -  2SEC    11 11CH  -  2SEC
       4  4CH  -  2SEC    12 12CH  -  2SEC
       5  5CH  -  2SEC    13 13CH  -  2SEC
       6  6CH  -  2SEC    14 14CH  -  2SEC
       7  7CH  -  2SEC    15 15CH  -  2SEC
       8  8CH  -  2SEC    16 16CH  -  2SEC
     
       
    Press the FUNCTION button to display the next
    page, then press this button again to return to
    the previous page.
    2. Move the cursor to the channel you want to edit,
    then press the SET button.
    The cursor moves to the title area, and the square
    cursor appears on the character table.
    3. To select a character, move the cursor on the
    desired character in the table by pressing the
    Direction Arrow buttons.
    4. Then press the SET button to pick up the char-
    acter, and place it in the title area.
    5. Repeat the above procedures 3 to 4 until the
    title for a certain camera is completed.
    6. If a wrong character is selected, press the
    Increment (+) or Decrement (–) button to move
    the cursor in the title area.
    Note:Press the (+) button to move the cursor to
    the right, or press the (–) button to move the
    cursor to the left.
    Then press the SET button to overwrite the
    character with the character selected in the
    table.
    7. Press the SETUP/ESC button to move the cursor
    to the channel number area.
    8. Repeat the above procedures 2 to 7 for the rest
    of the cameras.
    9. Move the cursor to the channel area, then press
    the SETUP/ESC button to return to the previous
    SYSTEM SETUP menu.
    4. Camera Title Display Position
    This item lets you select the camera title position to
    be displayed on the monitor screen.
    Refer to the Clock Display Position Setting on page
    30 for more details.
    1. Move the cursor to TITLE POSITION, then press
    the SET button. The position setting menu
    appears on the monitor screen.
    2. Move the title by pressing the Direction Arrow
    Buttons.
    Note:In the Multiscreen display with display of
    the Record out signals, the clock display is
    shifted one line from the preset position if
    the Camera Title and the Clock are preset
    to the same position.
    3. Press the SETUP/ESC button to execute the
    selection and return to the previous SYSTEM
    SETUP menu.
    5. Sequence Setup
    This item lets you program the sequence pattern for
    Spot or Multi Sequence.
    You can either program a spot sequence (SEQ1) or
    two multi sequences (SEQ2, SEQ3).
    Spot Sequence (SEQ1)
    This item lets you program or edit a Spot Sequence.
    Up to 32 steps can be assigned in the table shown
    below.
    You can also enable the Auto Skip function to skip
    any steps where no video signal is present.
    The duration of each step is determined by the
    Dwell Time setting.
    The initial factory setting is sequential display of 16
    camera pictures.
    1. Move the cursor to the SEQUENCE SETUP
    parameter on the SYSTEM SETUP menu.
    2. Select SEQ1 by pressing the LEFT or RIGHT
    button, then press the SET button. The setup
    menu shown below appears on the monitor
    screen.
    Auto Skip
    1. Move the cursor to the AUTO SKIP parameter.
    2. Select ON or OFF by pressing the LEFT or RIGHT
    button.
    ON:Enables the auto skip function.
    OFF:Disables the auto skip function.
    Note:The AUTO SKIP function is not available
    when playing back pictures.
    Step Assigment
    1. Move the cursor to the step number you want to
    edit in the CAM area by pressing the Direction
    Arrow  button.
    2. Select the desired camera or playback channel in
    the CAM area by pressing the Increment (+) or
    Decrement (–) button.
    1 - 16:Camera Channel
    P1 - P16:Playback Channel
    –:Not Assigned
    Notes:
    •Pressing the Camera Number Buttons assigns
    the camera channel directly.
    •Any playback steps programmed in a
    sequence are excluded from display on the
    Spot Monitor and Multiscreen Monitor 2 due to
    the way the system is designed.
    3. Repeat the above procedures to assign other
    steps. 
    						
    							-32-
           SEQ1(SPOT-SEQUENCE)SETUP 2 OF 2
                
      STEP CAM PRE TIME  STEP CAM PRE TIME
       17   -   -  2SEC   25   -   -  2SEC
       18   -   -  2SEC   26   -   -  2SEC
       19   -   -  2SEC   27   -   -  2SEC
       20   -   -  2SEC   28   -   -  2SEC
       21   -   -  2SEC   29   -   -  2SEC
       22   -   -  2SEC   30   -   -  2SEC
       23   -   -  2SEC   31   -   -  2SEC
       24   -   -  2SEC   32   -   -  2SEC
     
       
          SEQ3(MULTI-SEQUENCE)SETUP 1 OF 5
          AUTO SKIP  OFF
          STEP 1     CAM
          DWELL TIME 5SEC
            
          AREA  CAM PRE  AREA  CAM PRE    
            1   1CH  -     9    -   -   
            2   2CH  -    10    -   -   
            3   3CH  -    11    -   -   
            4   4CH  -    12    -   -   
            5   5CH  -    13    -   -   
            6   6CH  -    14    -   -   
            7   7CH  -    15    -   -    
            8   8CH  -    16    -   -   
     
       
          SEQ2(MULTI-SEQUENCE)SETUP 1 OF 5
          AUTO SKIP  OFF
          STEP 1     CAM
          DWELL TIME 3SEC
            
          AREA  CAM PRE  AREA  CAM PRE    
            1   1CH  -     9    -   -   
            2   2CH  -    10    -   -   
            3   3CH  -    11    -   -   
            4   4CH  -    12    -   -   
            5    -   -    13    -   -   
            6    -   -    14    -   -   
            7    -   -    15    -   -    
            8    -   -    16    -   -   
     
       
    Preset Position
    1. Move the cursor to the step number you want to
    edit in the PRE area by pressing the Derection
    Arrow Buttons.
    2. Select the desired preset position number in the
    PRE area by pressing the Increment (+) or
    Decrement (–) button.
    Note:A preset position assigned to a step that has
    been assigned to a playback channel is invalid.
    3. Repeat the above procedures to assign other
    steps.
    Dwell Time
    •Uniform Dwell Time
    1. Move the cursor to the DWELL TIME parameter.
    2. Select the desired dwell time by pressing the
    LEFT or RIGHT button.
    Dwell Time can be selected between 0SEC and
    30SEC.
    Note:If 0SEC is selected for dwell time, the
    spot sequence is not activated.
    •Individual Dwell Time
    1. Move the cursor to the step number you want to
    edit in the TIME area by pressing the Directon
    Arrow buttons.
    2. Select the desired dwell time by pressing the
    Increment (+) or Decrement (−) button.
    Steps for which a different dwell time has been
    selected are marked “−” in the DWELL TIME
    area. Previous settings made in the DWELL
    TIME area become invalid.
    Programming Steps 17 to 32
    1. Press the FUNCTION button to display the next
    page. The table shown below appears on the moni-
    tor screen.
    2. Program the sequence pattern for steps 17 to
    32 as described for the previous page.
    3. Press the FUNCTION button to display the pre-
    vious page.
    4. After finishing the setting, press the SET
    UP/ESC button to execute the setting and return
    to the previous SYSTEM SETUP menu.
    Auto Skip
    1. Move the cursor to the AUTO SKIP parameter.
    2. Select ON or OFF by pressing the LEFT or RIGHT
    button. The initial factory setting is ON.
    ON:Enables the auto skip function.
    OFF:Disables the auto skip function.
    Note:The AUTO SKIP function is not available
    when playing back pictures.
    Camera / Playback
    This item lets you select the camera or playback picture
    to be displayed at each step.
    1. Move the cursor to the STEP parameter.
    2. Select CAM or PLAY by pressing the LEFT or
    RIGHT button.
    CAM:Enables display of camera picture.
    PLAY: Enables display of playback picture.
    Multi Sequence (SEQ2, SEQ3)
    This item lets you program or edit a Multi
    Sequence. Up to 5 steps can be assigned in the
    table shown below.
    You can also enable the Auto Skip function to skip
    any steps where no video signal is present.
    The duration of each step is determined by the
    Dwell Time setting.
    According to the initial factory setting, SEQ2 is dis-
    played on four screen segments (quad) and SEQ3
    on nine segments.
    1. Move the cursor to the SEQUENCE SETUP
    parameter on the SYSTEM SETUP menu.
    2. Select SEQ2 or SEQ3 by pressing the LEFT or
    RIGHT button, then press the SET button. The
    setup menu shown below appears on the moni-
    tor screen. 
    						
    							-33-
    Dwell Time
    1. Move the cursor to the DWELL TIME parameter.
    2. Select the desired dwell time by pressing the LEFT
    or RIGHT button.
    Dwell Time can be selected between 0SEC and
    30SEC.
    Note:If 0SEC is selected for dwell time, that step
    will not be shown on the monitor screen.
    Display Channel Assignment
    1. Move the cursor to the area number you want to
    edit in the CAM area by pressing the Direction
    Arrow buttons.
    2. Select the desired camera or playback channel in
    the CAM area by pressing the Increment (+) or
    Decrement (–) button.
    3. Repeat the above procedures to assign other area
    numbers.
    Note:
    The multiscreen pattern of each step is determined
    automatically as follows:
    •For example, if several camra channels are
    assigned to area numbers, the screen segmen-
    tation that will accommodate the highest area
    number will be selected.
    •Areas not assigned a camera channel, or
    assigned a channel to which no camera is con-
    nected, are displayed in black.
    •Pressing the Camera Number Buttons assigns
    the camera channel directly.
    Preset Position
    1. Move the cursor to the area number you want to
    edit in the PRE area by pressing the Direction Arrow
    Buttons.
    2. Select the desired preset position number in the
    PRE area by pressing the Increment (+) or
    Decrement (–) button.
    Notes:
    •When the STEP parameter in this table is on
    PLAY, it is not possible to select a preset posi-
    tion in the PRE area.
    •It is possible to assign the same camera chan-
    nel to multiple area numbers within a step. In
    this case, make sure to assign the same preset
    positions.
    Programming Steps 2 to 5
    1. Press the FUNCTION button to display the next
    step.
    2. Program the sequence pattern for steps 2 to 5
    according to the procedures described above.
    3. After completing the setting, press the SETUP/ESC
    button to execute the setting and return to the previ-
    ous SYSTEM SETUP menu.
    6. Sequence Timing (Multiscreen)
    This item lets you select functions of devices con-
    nected to pin 26 of the ALARM/REMOTE Control
    Connector.One of these functions is input of the time adjust-
    ment signal from a VCR, the other enables external
    sequence switching for multiscreen output.
    1. Move the cursor to the SEQ TIMING-MLT para-
    meter.
    2. Select INT(TIME-ADJ) or EXT by pressing the
    LEFT or RIGHT button.
    INT:Advances a sequence by the Dwell Time
    that was programmed on the SEQUENCE
    SETUP menu.
    It enables input of the time adjustment sig-
    nal from a Time Lapse VCR.
    EXT:Enables external sequence switching.
    Notes:
    •If EXT is selected, time adjustment input
    from a Time Lapse VCR is disabled.
    •If EXT is selected, connect the external
    sequence switch to pin 26 of the ALARM/
    REMOTE Control Connector.
    •The Mutiplexer accepts the time adjustment
    signal for 6 minutes, that is, 3 minutes
    before and 3 minutes after the exact time
    (For example, from 9:57:00 through
    10:03:00.  Time is adjusted to 10:00:00).
    7. Sequence Timing (Spot)
    This item let you select between internal and exter-
    nal control for advancing the sequence on the Spot
    Monitor.
    1. Move the cursor to the SEQ TIMING-SPT para-
    meter.
    2. Select INT or EXT by pressing the LEFT or
    RIGHT button.
    INT:Advances a sequence by the Dwell Time
    that was programmed on the SEQUENCE
    SETUP menu.
    EXT:Advances a sequence by the input from
    pin 6 of the ALARM/REMOTE Control
    Connector.
    8. Lock Mode
    This item lets you decide which buttons will be
    locked while the LOCK switch is in ON position.
    1. Move the cursor to the LOCK MODE parameter.
    2. Select ALL or VCR by pressing the LEFT or
    RIGHT button. Initially, the initial factory setting
    is ALL.
    VCR:Locks the VCR Control Buttons.
    ALL:Locks all the buttons.
    Note:The LOCK indicator only lights up when
    the LOCK switch is in ON position and
    LOCK MODE is set to ALL. 
    						
    							-34-
          CABLE COMP/VD2/DATA SETUP 1 OF 2
     
             CAM  CABLE  VD2  DATA
     
             1CH    S    ON    ON
             2CH    S    ON    ON 
             3CH    S    ON    ON   
             4CH    S    ON    ON  
             5CH    S    OFF   OFF   
             6CH    S    OFF   OFF   
             7CH    S    OFF   OFF    
             8CH    S    OFF   OFF   
     
     
        
          CABLE COMP/VD2/DATA SETUP 2 OF 2
     
             CAM  CABLE  VD2  DATA
     
             9CH    S    OFF   OFF
            10CH    S    OFF   OFF 
            11CH    S    OFF   OFF   
            12CH    S    OFF   OFF  
            13CH    S    OFF   OFF   
            14CH    S    OFF   OFF   
            15CH    S    OFF   OFF    
            16CH    S    OFF   OFF   
     
     
        
    Press the FUNCTION button to display the next
    page, then press this button again to return to
    the previous page.
    2. Move the cursor to the channel you want to edit
    by pressing the Direction Arrow Buttons.
    3. Select one of the parameters shown below in
    the CABLE area by pressing the Increment (+)
    or Decrement (−) button.
    S:Up to 400 m (1 300 ft)
    M:400 m (1 300 ft) to 700 m (2 300 ft)
    L:700 m (2 300 ft) to 900 m (3 000 ft)
    When using the RG-59/U, BELDEN 9259 or
    equivalent cable.
    Note:Set CABLE to S if no camera is connect-
    ed to the channel.
    4. Select ON or OFF in the VD2 area by pressing
    the Increment (+) or Decrement (−) button.
    Note:Select ON for a camera with VD2 capabil-
    ity, otherwise select OFF.5. Select one of the parameters shown below in
    the DATA area by pressing the Increment (+) or
    Decrement (−) button.
    ON:Communicates with the camera site by
    multiplexed data.
    1-16:Communicate with the camera site by RS-
    485.
    This number indicates the unit address of
    the selected camera.
    OFF:Disables communication with the camera
    site.
    6. Repeat the above procedures to edit other
    channels.
    7. Press the SETUP/ESC button to execute the set-
    ting and return to the previous SYSTEM SETUP
    menu.
    Note:Installation of the WV-PB6164 Data Multi-
    plex Boards is required for controlling more
    than 4 cameras.
    10. Alarm Terminal Setup
    This item lets you edit the alarm input number cor-
    responding to each channel.
    1. Move the cursor to ALM TERMINAL SETUP on
    the SYSTEM SETUP menu, then press the SET
    button. The ALARM TERMINAL SETUP table
    shown below appears on the monitor screen.
              ALARM TERMINAL SETUP   
           
        NO.   CAM  PRE     NO.   CAM  PRE  
         1    1CH   -       9    9CH   -   
         2    2CH   -      10   10CH   -   
         3    3CH   -      11   11CH   -   
         4    4CH   -      12   12CH   -   
         5    5CH   -      13   13CH   -   
         6    6CH   -      14   14CH   -   
         7    7CH   -      15   15CH   -  
         8    8CH   -      16   16CH   -   
     
     
       
    2. Move the cursor to the number you want to  edit
    by pressing the Derection Arrow Buttons.
    3. Select the channel to be assigned in the CAM
    area by pressing the Increment (+) or
    Decrement (–) button.
    Note:Channel numbers can also be input
    directly with the camera Number Buttons.
    4. Select the preset position number to be
    assigned in the PRE area by pressing the
    Increment (+) or Decrement (–) button.
    5. Repeat the above procedures to assign other
    terminal numbers.
    6. Press the SETUP/ESC button to execute the set-
    ting and return to the previous SYSTEM SETUP
    menu.
    Note:The same channel can be assigned to
    multiple alarm terminals.
    In this case, different preset positions can
    be assigned, but when alarm occurs at
    these positions, the camera moves to the
    preset position where the most recent alarm
    occurred.
    9.Cable Compensation/VD2/ Data
    This item lets you select the optimum setting for the
    cable-loss compensator and whether to supply the
    VD2 (sync) signal or control data to the camera.
    Note:These settings will  work only for the input
    channels that have the multiplex feature with
    the Data Mutiplex Board WV-BP6164 installed.
    The boards are installed for input channels 1
    through 4 at the factory. You can install boards
    for other channels. For installations, see page
    10.
    1. Move the cursor to CABLE COMP/VD2/DATA
    SETUP on the SYSTEM MENU, then press the
    SET button. The CABLE COMP/VD2/DATA
    SETUP table shown below appears on the mon-
    itor screen. 
    						
    							-35-
    11. Playback Mode
    This item lets you select the ID code for playback of
    recorded video tape.
    1. Move the cursor to the PLAYBACK MODE para-
    meter.
    2. Select FIELD or FS10 by pressing the LEFT or
    RIGHT button.
    The initial factory setting is FIELD.
    FIELD:Normal position.
    FS10:Enables playback of a tape that is
    recorded on the WJ-FS10.
    12. Data Mode
    This item lets you select an external controller from
    the data port.
    1. Move the cursor to the DATA MODE parameter.
    2. Select CU550A or PC by pressing the LEFT or
    RIGHT button.
    CU550A:Enables control from the WV-CU550A
    System Controller.
    PC:Enables control from a PC.
    The initial factory setting is CU550A.
    13. RS-232C Mode
    This item lets you select the RS-232C port for con-
    trol of the VCR, or for external control of the system
    from a PC.
    1. Move the cursor to the RS-232C MODE para-
    meter.
    2. Select VCR or PC by pressing the LEFT or
    RIGHT button.
    VCR:Enables use as VCR control port.
    PC:Enables use as external control port from a
    PC. 
    The initial factory setting is VCR.
    Note:Be sure to select PC on this menu if you
    plan to use the REMOTE OUT connector for
    controlling the VCR.
                 COM PORT SETUP
                   RS-232C DATA    RS-485
        DELAY       OFF    OFF     OFF  
        BAUD RATE   9600   9600    19200
        WAIT TIME   OFF    100     OFF
        DATA BIT    7      8       8
        PARITY      ODD    EVEN    NONE
        STOP BIT    1      1       1
        XON/XOFF    -      OFF     OFF
        FULL/HALF   -      -       FULL
        
        
       
    2. Move the cursor to the port you want to edit by
    pressing the Direction Arrow Buttons.
    3. Select the desired Delay Time in the DELAY
    area by pressing the Increment (+) or
    Decrement (–) button.
    4. Select the desired Baud Rate in the BAUD
    RATE area by pressing the Increment (+) or
    Decrement (–) button.
    5. Select the desired Wait Time in the WAIT TIME
    area by pressing the Increment (+) or
    Decrement (–) button.
    6. Select 7 or 8 in the DATA BIT area by pressing
    the Increment (+) or Decrement (–) button.
    7. Select the desired Parity Check in the PARITY
    area by pressing the Increment (+) or
    Decrement (–) button.
    8. Select 1 or 2 in the STOP BIT area by pressing
    the Increment (+) or Decrement (–) button.
    9. Select ON or OFF in the XON/XOFF area by
    pressing the Increment (+) or Decrement (–)
    button. (except RS-232C)
    10. Select FULL or HALF Duplex in the FULL/HALF
    area by pressing the Increment (+) or
    Decrement (–) button. (RS-485 only)
    11. Repeat the above procedures to edit other
    ports.
    12. Press the SETUP/ESC button to execute the set-
    ting and return to the previous SYSTEM SETUP
    menu.
    14. Communication Port Setup
    This item lets you set the parameters for communi-
    cation between the ports and the connected appli-
    ances.
    1. Move the cursor to COM PORT SETUP, then
    press the SET button. The COM PORT SETUP
    table shown below appears on the monitor
    screen. 
    						
    							-36-
    15. VCR Input Select
    This item lets you select the VCR input terminal.
    1. Move the cursor to the VCR IN SELECT para-
    meter.
    2. Select VIDEO or S-VIDEO by pressing the LEFT
    or RIGHT button.
    VIDEO:Selects input from the VCR VIDEO ter-
    minal.
    S-VIDEO:Selects input from the VCR S-VIDEO
    terminal.
    The initial factory setting is VIDEO.
    16. Daisy Mode
    This item lets you select whether to have the video
    signal connected to SPOT IN looped through to the
    SPOT OUT connector (daisy-chain connection).
    1. Move the cursor to the DAISY MODE parame-
    ter.
    2. Select ON or OFF by pressing the LEFT or
    RIGHT button.
    ON:Select this parameter if the Video
    Multiplexer is daisy-chained.
    OFF:Normal position.
    The initial factory setting is OFF.
    17. Unit Address
    This item lets you assign a unit number for identifi-
    cation when multiple Video Multiplexers are con-
    nected in a system.
    1. Move the cursor to the UNIT ADDR. SET para-
    meter.
    2. Select the desired unit number by pressing the
    LEFT or RIGHT button.
    The initial factory setting is 1.
    After finishing the settings, press the SETUP/ESC
    button to execute the settings and return to the pre-
    vious SETUP MENU.
                CAM DOWNLOAD
           DOWNLOAD        1CH  NO
     
       CAM    1  2  3  4  5  6  7  8 
       DATA  O+  - O+  -  - N-  +  -
     
       CAM    9 10 11 12 13 14 15 16 
       DATA   -  -  -  -  -  -  -  - 
     
          O:RESULT OK  +:DATA EXISTENCE
          N:RESULT NG  -:DATA NOTHING
                  
       CAUTION:ALL ALARM INPUTS
               HAVE BEEN DISABLED.
    Camera Download
    This item lets you save the camera setup data into
    the memory of the Video Multiplexer.
    If the setup contents of the camera should be lost
    due to malfunctioning or replacement of a camera,
    you can simply reload the data stored in the Video
    Multiplexer.
    1. Move the cursor to the CAM DOWNLOAD para-
    meter in the SETUP MENU.
    2. Select YES by pressing the LEFT or RIGHT but-
    ton, then press the SET button 
    The CAM DOWNLOAD table shown below
    appears on the monitor screen.
    3. Select the channel you want to edit by pressing
    the LEFT or RIGHT button.
    1CH - 16CH:Enables storing of setup data for
    the selected camera channel.
    ALL:Enables storing of setup data for all cam-
    era channels.
    Note:Channel numbers can also be input
    directly with the Camera Number Buttons.
    4. Move the cursor to “NO” by pressing the UP or
    DOWN button.
    5. Select “YES“ by pressing the LEFT or RIGHT
    button.
    6. Press the SET button to begin loading. “NOW
    LOADING” appears on the table.
    To cancel loading, press the SETUP/ESC but-
    ton.
    7. When loading is finished, the result is displayed
    for each channel.
    8. Press the SETUP/ESC button, then system will
    restart.
    Note:Alarm is disabled while this menu is dis-
    played. 
    						
    							-37-
                CAM UPLOAD
           UPLOAD          1CH  NO
     
       CAM    1  2  3  4  5  6  7  8 
       DATA  O+  - O+  -  - N-  +  -
     
       CAM    9 10 11 12 13 14 15 16 
       DATA   -  -  -  -  -  -  -  - 
     
          O:RESULT OK  +:DATA EXISTENCE
          N:RESULT NG  -:DATA NOTHING
                  
       CAUTION:ALL ALARM INPUTS
               HAVE BEEN DISABLED.
               ALL RESET SELECT
           ALL-RESET      NO
       CAUTION:ALL ALARM INPUTS
               HAVE BEEN DISABLED.
    Camera Upload
    This item lets you upload camera setup data from
    the Video Multiplexer’s memory to a camera.
    1. Move the cursor to the CAM UPLOAD parameter
    in the SETUP MENU.
    2. Select YES by pressing the LEFT or RIGHT but-
    ton, then press the SET button.
    The CAM UPLOAD table shown below appears
    on the monitor screen.
    3. Select the channel you want to edit by pressing
    the LEFT or RIGHT button.
    1CH - 16CH:Enables data uploading to a
    selected camera.
    ALL:Enables data uploading to all cameras.
    Note:Channel numbers can also be input
    directly with the Camera Number Buttons.
    4. Move the cursor to “NO” by pressing the UP or
    DOWN button.
    5. Select “YES” by pressing the LEFT or RIGHT
    button.
    6. Press the SET button to begin the load. “NOW
    LOADING” appears on the table.
    To cancel loading, press the SETUP/ESC but-
    ton.
    7. When loading is finished, the result is displayed
    for each channel.
    8. Press the SETUP/ESC button, then system will
    restart.
    Note:Alarm is disabled while this menu is dis-
    played.
    All Reset
    This item lets you restore the factory settings without
    having to go through each individual menu.
    1. Move the cursor to ALL RESET SELECT on the
    SETUP MENU, then press the SET button. The
    ALL RESET SELECT menu shown below
    appears on the monitor screen.
    2. Select “YES” by pressing the LEFT or RIGHT
    button.
    3. Press the SET button to execute the All Reset
    function.
    4. First “NOW RESETTING” appears, then “RESET
    COMPLETED”.
    5. Press the SETUP/ESC button to return to the
    SETUP MENU.
    Note: Alarm is disabled while the ALL RESET
    menu is displayed. 
    						
    							-38-
    OPERATING PROCEDURES
    VCR
    CAM
    SPOT
    ENTRANCE
    STILL
    SEQUENCE
    MULTI
    SCREEN
    STILL
    MONITOR CONTROL 
    FUNCTION
    Before starting the following procedures, all system 
    components should be turned on.
    Then set the LOCK switch to the OFF position.
    Operating the Spot Monitor
    The following operations are available on the Spot
    Monitor.
    Displaying the Camera Picture
    1. Single Spot
    1. Press the SPOTbutton.  The LED (green) on the
    button lights up.
    2. Press a CAMERA (1 - 16)button to display a
    selected camera picture on the monitor screen.
    The LED on the selected CAMERA button lights up.
    2. Spot Sequence
    1. Press the SPOTbutton.  The LED (green) on the
    button lights up.
    2. Press the SEQUENCEbutton to activate the
    sequence (SEQ1) programmed.
    The LED on the SEQUENCE button lights up.
    Note:Refer to the Sequence Setup on page 31 for
    more details.
    3. Press the SEQUENCEbutton to move one step for-
    ward in the sequence.
    4. To cancel the sequence, press the respective
    CAMERAbutton again.
    The selected camera picture is displayed in spot
    mode.
    Operating the Multiscreen
    Monitor
    The following operations are available on the Multi-
    screen Monitor.
    Note:We recommend to use the Single Spot when
    displaying non-interlace pictures, for instance,
    the Menu screen of the WJ-SX550, to prevent
    picture disturbance.
    Displaying the Camera Picture
    1. Single Spot
    1. Press the MULTISCREENbutton.  The LED (green)
    on the button lights up.
    2. Press the VCR/CAMbutton to CAMposition (LED
    off).
    3. Press a CAMERA (1 - 16)button to display a
    selected camera picture on the monitor screen.
    The LED on the selected CAMERA button lights up.
    2. Single Still
    1. Repeat the step 1 - 3 described above for Single
    Spot.
    2. Press the STILLbutton to freeze the displayed pic-
    ture.
    The LED on the STILL button lights up, and the LED
    on the pressed CAMERA button starts to blink.
    The camera title and “STILL” (both blinking) alter-
    nate in the display.
    3. To cancel the still picture, press the STILLbutton
    again.
    The selected camera picture is displayed in spot
    mode. 
    						