-29- 4. Press the SET button to move the cursor to the recording mode title area. The square cursor appears in the character table. 5. To select a character, move the cursor on the desired character in the table by pressing the Direction Arrow buttons. 6. Press the SET button to pick up the character and place it in the title area. 7. Repeat the above procedures 5 to 6 to set the title. 8. If a wrong character is selected, press the Increment (+) or Decrement (–) button to move the cursor in the title area. Note:Press the (+) button to move the cursor to the right, or press the (–) button to move the cursor to the left. Then press the SET button to overwrite the character with the character selected from the table. 9. Press the SETUP/ESC button. The cursor moves to MODE number. 10. Repeat the above procedures 1 to 9 to assign the other MODE numbers. 11. After completing the setting, press the SET UP/ESC button to return to the REC OUTPUT SETUP menu. After finishing the setting, press the SETUP/ESC button to return to the previous SETUP MENU. Multiscreen 2 Output Setup These items let you select the mode when connect- ing the Record Output (REC OUT) to the monitor for Multiscreen 2 Monitor. WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 MULTI2 OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * 1. Move the cursor to the REC/MULTI2 parameter on the SETUP MENU. 2. Select MULTI2 OUTPUT by pressing the LEFT or RIGHT button, then press the SET button. The MULTI2 OUTPUT SETUP menu appears on the monitor screen as shown below. MULTI2 OUTPUT SETUP DISPLAY POSITION * SEQUENCE MODE SEQ2 1. Camera Display Position This item lets you select the position where the camera picture will be displayed on the Multiscreen Monitor 2. 1. Move the cursor to DISPLAY POSITION, then press the SET button. The table shown below appears on the monitor. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2. Move the cursor to the desired channel number by pressing the UP or DOWN button. 3. Select the numbers of the cameras to be dis- played by pressing the LEFT or RIGHT button. The pictures of the selected cameras are dis- played one after another on the monitor screen. Note:Numbers can also be input directly with the Camera Number Buttons (1 - 10). 4. After completing the setting, press the SET UP/ESC button to return to the previous MULTI 2 OUTPUT SETUP menu. Note:This operation only affects the camera display positions. It has no effect on the camera channel, recording order or sequence order. 2. Sequence Mode This item lets you select the sequence pattern for display on the Multiscreen Monitor 2. Refer to Sequence Setup on page 31 for more details. 1. Move the cursor to the SEQUENCE MODE parameter. 2. Select the desired mode by pressing the LEFT or RIGHT button. The initial factory setting is SEQ2. SEQ1:Spot Sequence SEQ2:Multi Sequence SEQ3:Multi Sequence After finishing the setting, press the SETUP/ESC button to return to the previous SETUP MENU.
-30- System Setup Move the cursor to SYSTEM SETUP on the SETUP MENU, then press the SET button. The SYSTEM SETUP menu appears on the monitor screen as shown below. Press the FUNCTION button to display the next page. Press this button again to return to the previ- ous page. 1. Clock Setup This item lets you set the current time and date. 1. Move the cursor to CLOCK SETUP, then press the SET button to move the cursor to the editing area. 2. Move the cursor to the area you want to edit by pressing the UP or DOWN button, then select the month or number by pressing the LEFT or RIGHT button. 3. After finishing the setting, press the SETUP/ ESC button to move the cursor to CLOCK SETUP. Note:The date and time are updated when the SETUP/ESC button is pressed. SYSTEM SETUP 1 OF 2 CLOCK SETUP JAN 1.97 0:00 CLOCK POSITION * TITLE SETUP * TITLE POSITION * SEQUENCE SETUP SEQ1 * SEQ TIMING-MLT INT(TIME-ADJ) SEQ TIMING-SPT INT LOCK MODE ALL SYSTEM SETUP 2 OF 2 CABLE COMP/VD2/DATA SETUP * ALM TERMINAL SETUP * PLAYBACK MODE FIELD DATA MODE CU550A RS-232C MODE VCR COM PORT SETUP * VCR IN SELECT VIDEO DAISY MODE OFF UNIT ADDR.SET 1 DEC11.96 12:00:00 CAMTITLE WJ-FS616 SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 MULTI2 OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * TITLE SETUP 1 OF 2 1CH 1------- 0123456789 2CH 2------- ABCDEFGHIJK 3CH 3------- LMNOPQRSTUV 4CH 4------- WXYZ 5CH 5------- abcdefghijk 6CH 6------- imnopqrstuv 7CH 7------- wxyz 8CH 8------- ¤=?#&()* +,-./:;E @ TITLE SETUP 2 OF 2 9CH 9------- 0123456789 10CH 10------ ABCDEFGHIJK 11CH 11------ LMNOPQRSTUV 12CH 12------ WXYZ 13CH 13------ abcdefghijk 14CH 14------ imnopqrstuv 15CH 15------ wxyz 16CH 16------ ¤=?#&()* +,-./:;E @ 2. Clock Display Position This item lets you select the position where the clock will be displayed on the monitor screen. 1. Move the cursor to CLOCK POSITION, then press the SET button. The position setting menu appears on the monitor screen as show below. 2. Move the clock position by pressing the Direction Arrow Buttons. Note:In the Multiscreen display with display of the Record out signals, the clock display is shifted one line from the preset position if the Camera Title and the Clock are preset to the same position. 3. Press the SETUP/ESC button to execute the selection and return to the previous SYSTEM SETUP menu. 3. Camera Title Setup This item lets you edit the camera title to be dis- played on the monitor screen. Up to 8 alphanumeric characters can be displayed on the monitor. 1. Move the cursor to TITLE SETUP, then press the SET button. The TITLE SETUP menu appears on the monitor screen as shown below.
-31- SEQ1(SPOT-SEQUENCE)SETUP 1 OF 2 AUTO SKIP OFF DWELL TIME 2SEC STEP CAM PRE TIME STEP CAM PRE TIME 1 1CH - 2SEC 9 9CH - 2SEC 2 2CH - 2SEC 10 10CH - 2SEC 3 3CH - 2SEC 11 11CH - 2SEC 4 4CH - 2SEC 12 12CH - 2SEC 5 5CH - 2SEC 13 13CH - 2SEC 6 6CH - 2SEC 14 14CH - 2SEC 7 7CH - 2SEC 15 15CH - 2SEC 8 8CH - 2SEC 16 16CH - 2SEC Press the FUNCTION button to display the next page, then press this button again to return to the previous page. 2. Move the cursor to the channel you want to edit, then press the SET button. The cursor moves to the title area, and the square cursor appears on the character table. 3. To select a character, move the cursor on the desired character in the table by pressing the Direction Arrow buttons. 4. Then press the SET button to pick up the char- acter, and place it in the title area. 5. Repeat the above procedures 3 to 4 until the title for a certain camera is completed. 6. If a wrong character is selected, press the Increment (+) or Decrement (–) button to move the cursor in the title area. Note:Press the (+) button to move the cursor to the right, or press the (–) button to move the cursor to the left. Then press the SET button to overwrite the character with the character selected in the table. 7. Press the SETUP/ESC button to move the cursor to the channel number area. 8. Repeat the above procedures 2 to 7 for the rest of the cameras. 9. Move the cursor to the channel area, then press the SETUP/ESC button to return to the previous SYSTEM SETUP menu. 4. Camera Title Display Position This item lets you select the camera title position to be displayed on the monitor screen. Refer to the Clock Display Position Setting on page 30 for more details. 1. Move the cursor to TITLE POSITION, then press the SET button. The position setting menu appears on the monitor screen. 2. Move the title by pressing the Direction Arrow Buttons. Note:In the Multiscreen display with display of the Record out signals, the clock display is shifted one line from the preset position if the Camera Title and the Clock are preset to the same position. 3. Press the SETUP/ESC button to execute the selection and return to the previous SYSTEM SETUP menu. 5. Sequence Setup This item lets you program the sequence pattern for Spot or Multi Sequence. You can either program a spot sequence (SEQ1) or two multi sequences (SEQ2, SEQ3). Spot Sequence (SEQ1) This item lets you program or edit a Spot Sequence. Up to 32 steps can be assigned in the table shown below. You can also enable the Auto Skip function to skip any steps where no video signal is present. The duration of each step is determined by the Dwell Time setting. The initial factory setting is sequential display of 16 camera pictures. 1. Move the cursor to the SEQUENCE SETUP parameter on the SYSTEM SETUP menu. 2. Select SEQ1 by pressing the LEFT or RIGHT button, then press the SET button. The setup menu shown below appears on the monitor screen. Auto Skip 1. Move the cursor to the AUTO SKIP parameter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. ON:Enables the auto skip function. OFF:Disables the auto skip function. Note:The AUTO SKIP function is not available when playing back pictures. Step Assigment 1. Move the cursor to the step number you want to edit in the CAM area by pressing the Direction Arrow button. 2. Select the desired camera or playback channel in the CAM area by pressing the Increment (+) or Decrement (–) button. 1 - 16:Camera Channel P1 - P16:Playback Channel –:Not Assigned Notes: •Pressing the Camera Number Buttons assigns the camera channel directly. •Any playback steps programmed in a sequence are excluded from display on the Spot Monitor and Multiscreen Monitor 2 due to the way the system is designed. 3. Repeat the above procedures to assign other steps.
-32- SEQ1(SPOT-SEQUENCE)SETUP 2 OF 2 STEP CAM PRE TIME STEP CAM PRE TIME 17 - - 2SEC 25 - - 2SEC 18 - - 2SEC 26 - - 2SEC 19 - - 2SEC 27 - - 2SEC 20 - - 2SEC 28 - - 2SEC 21 - - 2SEC 29 - - 2SEC 22 - - 2SEC 30 - - 2SEC 23 - - 2SEC 31 - - 2SEC 24 - - 2SEC 32 - - 2SEC SEQ3(MULTI-SEQUENCE)SETUP 1 OF 5 AUTO SKIP OFF STEP 1 CAM DWELL TIME 5SEC AREA CAM PRE AREA CAM PRE 1 1CH - 9 - - 2 2CH - 10 - - 3 3CH - 11 - - 4 4CH - 12 - - 5 5CH - 13 - - 6 6CH - 14 - - 7 7CH - 15 - - 8 8CH - 16 - - SEQ2(MULTI-SEQUENCE)SETUP 1 OF 5 AUTO SKIP OFF STEP 1 CAM DWELL TIME 3SEC AREA CAM PRE AREA CAM PRE 1 1CH - 9 - - 2 2CH - 10 - - 3 3CH - 11 - - 4 4CH - 12 - - 5 - - 13 - - 6 - - 14 - - 7 - - 15 - - 8 - - 16 - - Preset Position 1. Move the cursor to the step number you want to edit in the PRE area by pressing the Derection Arrow Buttons. 2. Select the desired preset position number in the PRE area by pressing the Increment (+) or Decrement (–) button. Note:A preset position assigned to a step that has been assigned to a playback channel is invalid. 3. Repeat the above procedures to assign other steps. Dwell Time •Uniform Dwell Time 1. Move the cursor to the DWELL TIME parameter. 2. Select the desired dwell time by pressing the LEFT or RIGHT button. Dwell Time can be selected between 0SEC and 30SEC. Note:If 0SEC is selected for dwell time, the spot sequence is not activated. •Individual Dwell Time 1. Move the cursor to the step number you want to edit in the TIME area by pressing the Directon Arrow buttons. 2. Select the desired dwell time by pressing the Increment (+) or Decrement (−) button. Steps for which a different dwell time has been selected are marked “−” in the DWELL TIME area. Previous settings made in the DWELL TIME area become invalid. Programming Steps 17 to 32 1. Press the FUNCTION button to display the next page. The table shown below appears on the moni- tor screen. 2. Program the sequence pattern for steps 17 to 32 as described for the previous page. 3. Press the FUNCTION button to display the pre- vious page. 4. After finishing the setting, press the SET UP/ESC button to execute the setting and return to the previous SYSTEM SETUP menu. Auto Skip 1. Move the cursor to the AUTO SKIP parameter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. The initial factory setting is ON. ON:Enables the auto skip function. OFF:Disables the auto skip function. Note:The AUTO SKIP function is not available when playing back pictures. Camera / Playback This item lets you select the camera or playback picture to be displayed at each step. 1. Move the cursor to the STEP parameter. 2. Select CAM or PLAY by pressing the LEFT or RIGHT button. CAM:Enables display of camera picture. PLAY: Enables display of playback picture. Multi Sequence (SEQ2, SEQ3) This item lets you program or edit a Multi Sequence. Up to 5 steps can be assigned in the table shown below. You can also enable the Auto Skip function to skip any steps where no video signal is present. The duration of each step is determined by the Dwell Time setting. According to the initial factory setting, SEQ2 is dis- played on four screen segments (quad) and SEQ3 on nine segments. 1. Move the cursor to the SEQUENCE SETUP parameter on the SYSTEM SETUP menu. 2. Select SEQ2 or SEQ3 by pressing the LEFT or RIGHT button, then press the SET button. The setup menu shown below appears on the moni- tor screen.
-33- Dwell Time 1. Move the cursor to the DWELL TIME parameter. 2. Select the desired dwell time by pressing the LEFT or RIGHT button. Dwell Time can be selected between 0SEC and 30SEC. Note:If 0SEC is selected for dwell time, that step will not be shown on the monitor screen. Display Channel Assignment 1. Move the cursor to the area number you want to edit in the CAM area by pressing the Direction Arrow buttons. 2. Select the desired camera or playback channel in the CAM area by pressing the Increment (+) or Decrement (–) button. 3. Repeat the above procedures to assign other area numbers. Note: The multiscreen pattern of each step is determined automatically as follows: •For example, if several camra channels are assigned to area numbers, the screen segmen- tation that will accommodate the highest area number will be selected. •Areas not assigned a camera channel, or assigned a channel to which no camera is con- nected, are displayed in black. •Pressing the Camera Number Buttons assigns the camera channel directly. Preset Position 1. Move the cursor to the area number you want to edit in the PRE area by pressing the Direction Arrow Buttons. 2. Select the desired preset position number in the PRE area by pressing the Increment (+) or Decrement (–) button. Notes: •When the STEP parameter in this table is on PLAY, it is not possible to select a preset posi- tion in the PRE area. •It is possible to assign the same camera chan- nel to multiple area numbers within a step. In this case, make sure to assign the same preset positions. Programming Steps 2 to 5 1. Press the FUNCTION button to display the next step. 2. Program the sequence pattern for steps 2 to 5 according to the procedures described above. 3. After completing the setting, press the SETUP/ESC button to execute the setting and return to the previ- ous SYSTEM SETUP menu. 6. Sequence Timing (Multiscreen) This item lets you select functions of devices con- nected to pin 26 of the ALARM/REMOTE Control Connector.One of these functions is input of the time adjust- ment signal from a VCR, the other enables external sequence switching for multiscreen output. 1. Move the cursor to the SEQ TIMING-MLT para- meter. 2. Select INT(TIME-ADJ) or EXT by pressing the LEFT or RIGHT button. INT:Advances a sequence by the Dwell Time that was programmed on the SEQUENCE SETUP menu. It enables input of the time adjustment sig- nal from a Time Lapse VCR. EXT:Enables external sequence switching. Notes: •If EXT is selected, time adjustment input from a Time Lapse VCR is disabled. •If EXT is selected, connect the external sequence switch to pin 26 of the ALARM/ REMOTE Control Connector. •The Mutiplexer accepts the time adjustment signal for 6 minutes, that is, 3 minutes before and 3 minutes after the exact time (For example, from 9:57:00 through 10:03:00. Time is adjusted to 10:00:00). 7. Sequence Timing (Spot) This item let you select between internal and exter- nal control for advancing the sequence on the Spot Monitor. 1. Move the cursor to the SEQ TIMING-SPT para- meter. 2. Select INT or EXT by pressing the LEFT or RIGHT button. INT:Advances a sequence by the Dwell Time that was programmed on the SEQUENCE SETUP menu. EXT:Advances a sequence by the input from pin 6 of the ALARM/REMOTE Control Connector. 8. Lock Mode This item lets you decide which buttons will be locked while the LOCK switch is in ON position. 1. Move the cursor to the LOCK MODE parameter. 2. Select ALL or VCR by pressing the LEFT or RIGHT button. Initially, the initial factory setting is ALL. VCR:Locks the VCR Control Buttons. ALL:Locks all the buttons. Note:The LOCK indicator only lights up when the LOCK switch is in ON position and LOCK MODE is set to ALL.
-34- CABLE COMP/VD2/DATA SETUP 1 OF 2 CAM CABLE VD2 DATA 1CH S ON ON 2CH S ON ON 3CH S ON ON 4CH S ON ON 5CH S OFF OFF 6CH S OFF OFF 7CH S OFF OFF 8CH S OFF OFF CABLE COMP/VD2/DATA SETUP 2 OF 2 CAM CABLE VD2 DATA 9CH S OFF OFF 10CH S OFF OFF 11CH S OFF OFF 12CH S OFF OFF 13CH S OFF OFF 14CH S OFF OFF 15CH S OFF OFF 16CH S OFF OFF Press the FUNCTION button to display the next page, then press this button again to return to the previous page. 2. Move the cursor to the channel you want to edit by pressing the Direction Arrow Buttons. 3. Select one of the parameters shown below in the CABLE area by pressing the Increment (+) or Decrement (−) button. S:Up to 400 m (1 300 ft) M:400 m (1 300 ft) to 700 m (2 300 ft) L:700 m (2 300 ft) to 900 m (3 000 ft) When using the RG-59/U, BELDEN 9259 or equivalent cable. Note:Set CABLE to S if no camera is connect- ed to the channel. 4. Select ON or OFF in the VD2 area by pressing the Increment (+) or Decrement (−) button. Note:Select ON for a camera with VD2 capabil- ity, otherwise select OFF.5. Select one of the parameters shown below in the DATA area by pressing the Increment (+) or Decrement (−) button. ON:Communicates with the camera site by multiplexed data. 1-16:Communicate with the camera site by RS- 485. This number indicates the unit address of the selected camera. OFF:Disables communication with the camera site. 6. Repeat the above procedures to edit other channels. 7. Press the SETUP/ESC button to execute the set- ting and return to the previous SYSTEM SETUP menu. Note:Installation of the WV-PB6164 Data Multi- plex Boards is required for controlling more than 4 cameras. 10. Alarm Terminal Setup This item lets you edit the alarm input number cor- responding to each channel. 1. Move the cursor to ALM TERMINAL SETUP on the SYSTEM SETUP menu, then press the SET button. The ALARM TERMINAL SETUP table shown below appears on the monitor screen. ALARM TERMINAL SETUP NO. CAM PRE NO. CAM PRE 1 1CH - 9 9CH - 2 2CH - 10 10CH - 3 3CH - 11 11CH - 4 4CH - 12 12CH - 5 5CH - 13 13CH - 6 6CH - 14 14CH - 7 7CH - 15 15CH - 8 8CH - 16 16CH - 2. Move the cursor to the number you want to edit by pressing the Derection Arrow Buttons. 3. Select the channel to be assigned in the CAM area by pressing the Increment (+) or Decrement (–) button. Note:Channel numbers can also be input directly with the camera Number Buttons. 4. Select the preset position number to be assigned in the PRE area by pressing the Increment (+) or Decrement (–) button. 5. Repeat the above procedures to assign other terminal numbers. 6. Press the SETUP/ESC button to execute the set- ting and return to the previous SYSTEM SETUP menu. Note:The same channel can be assigned to multiple alarm terminals. In this case, different preset positions can be assigned, but when alarm occurs at these positions, the camera moves to the preset position where the most recent alarm occurred. 9.Cable Compensation/VD2/ Data This item lets you select the optimum setting for the cable-loss compensator and whether to supply the VD2 (sync) signal or control data to the camera. Note:These settings will work only for the input channels that have the multiplex feature with the Data Mutiplex Board WV-BP6164 installed. The boards are installed for input channels 1 through 4 at the factory. You can install boards for other channels. For installations, see page 10. 1. Move the cursor to CABLE COMP/VD2/DATA SETUP on the SYSTEM MENU, then press the SET button. The CABLE COMP/VD2/DATA SETUP table shown below appears on the mon- itor screen.
-35- 11. Playback Mode This item lets you select the ID code for playback of recorded video tape. 1. Move the cursor to the PLAYBACK MODE para- meter. 2. Select FIELD or FS10 by pressing the LEFT or RIGHT button. The initial factory setting is FIELD. FIELD:Normal position. FS10:Enables playback of a tape that is recorded on the WJ-FS10. 12. Data Mode This item lets you select an external controller from the data port. 1. Move the cursor to the DATA MODE parameter. 2. Select CU550A or PC by pressing the LEFT or RIGHT button. CU550A:Enables control from the WV-CU550A System Controller. PC:Enables control from a PC. The initial factory setting is CU550A. 13. RS-232C Mode This item lets you select the RS-232C port for con- trol of the VCR, or for external control of the system from a PC. 1. Move the cursor to the RS-232C MODE para- meter. 2. Select VCR or PC by pressing the LEFT or RIGHT button. VCR:Enables use as VCR control port. PC:Enables use as external control port from a PC. The initial factory setting is VCR. Note:Be sure to select PC on this menu if you plan to use the REMOTE OUT connector for controlling the VCR. COM PORT SETUP RS-232C DATA RS-485 DELAY OFF OFF OFF BAUD RATE 9600 9600 19200 WAIT TIME OFF 100 OFF DATA BIT 7 8 8 PARITY ODD EVEN NONE STOP BIT 1 1 1 XON/XOFF - OFF OFF FULL/HALF - - FULL 2. Move the cursor to the port you want to edit by pressing the Direction Arrow Buttons. 3. Select the desired Delay Time in the DELAY area by pressing the Increment (+) or Decrement (–) button. 4. Select the desired Baud Rate in the BAUD RATE area by pressing the Increment (+) or Decrement (–) button. 5. Select the desired Wait Time in the WAIT TIME area by pressing the Increment (+) or Decrement (–) button. 6. Select 7 or 8 in the DATA BIT area by pressing the Increment (+) or Decrement (–) button. 7. Select the desired Parity Check in the PARITY area by pressing the Increment (+) or Decrement (–) button. 8. Select 1 or 2 in the STOP BIT area by pressing the Increment (+) or Decrement (–) button. 9. Select ON or OFF in the XON/XOFF area by pressing the Increment (+) or Decrement (–) button. (except RS-232C) 10. Select FULL or HALF Duplex in the FULL/HALF area by pressing the Increment (+) or Decrement (–) button. (RS-485 only) 11. Repeat the above procedures to edit other ports. 12. Press the SETUP/ESC button to execute the set- ting and return to the previous SYSTEM SETUP menu. 14. Communication Port Setup This item lets you set the parameters for communi- cation between the ports and the connected appli- ances. 1. Move the cursor to COM PORT SETUP, then press the SET button. The COM PORT SETUP table shown below appears on the monitor screen.
-36- 15. VCR Input Select This item lets you select the VCR input terminal. 1. Move the cursor to the VCR IN SELECT para- meter. 2. Select VIDEO or S-VIDEO by pressing the LEFT or RIGHT button. VIDEO:Selects input from the VCR VIDEO ter- minal. S-VIDEO:Selects input from the VCR S-VIDEO terminal. The initial factory setting is VIDEO. 16. Daisy Mode This item lets you select whether to have the video signal connected to SPOT IN looped through to the SPOT OUT connector (daisy-chain connection). 1. Move the cursor to the DAISY MODE parame- ter. 2. Select ON or OFF by pressing the LEFT or RIGHT button. ON:Select this parameter if the Video Multiplexer is daisy-chained. OFF:Normal position. The initial factory setting is OFF. 17. Unit Address This item lets you assign a unit number for identifi- cation when multiple Video Multiplexers are con- nected in a system. 1. Move the cursor to the UNIT ADDR. SET para- meter. 2. Select the desired unit number by pressing the LEFT or RIGHT button. The initial factory setting is 1. After finishing the settings, press the SETUP/ESC button to execute the settings and return to the pre- vious SETUP MENU. CAM DOWNLOAD DOWNLOAD 1CH NO CAM 1 2 3 4 5 6 7 8 DATA O+ - O+ - - N- + - CAM 9 10 11 12 13 14 15 16 DATA - - - - - - - - O:RESULT OK +:DATA EXISTENCE N:RESULT NG -:DATA NOTHING CAUTION:ALL ALARM INPUTS HAVE BEEN DISABLED. Camera Download This item lets you save the camera setup data into the memory of the Video Multiplexer. If the setup contents of the camera should be lost due to malfunctioning or replacement of a camera, you can simply reload the data stored in the Video Multiplexer. 1. Move the cursor to the CAM DOWNLOAD para- meter in the SETUP MENU. 2. Select YES by pressing the LEFT or RIGHT but- ton, then press the SET button The CAM DOWNLOAD table shown below appears on the monitor screen. 3. Select the channel you want to edit by pressing the LEFT or RIGHT button. 1CH - 16CH:Enables storing of setup data for the selected camera channel. ALL:Enables storing of setup data for all cam- era channels. Note:Channel numbers can also be input directly with the Camera Number Buttons. 4. Move the cursor to “NO” by pressing the UP or DOWN button. 5. Select “YES“ by pressing the LEFT or RIGHT button. 6. Press the SET button to begin loading. “NOW LOADING” appears on the table. To cancel loading, press the SETUP/ESC but- ton. 7. When loading is finished, the result is displayed for each channel. 8. Press the SETUP/ESC button, then system will restart. Note:Alarm is disabled while this menu is dis- played.
-37- CAM UPLOAD UPLOAD 1CH NO CAM 1 2 3 4 5 6 7 8 DATA O+ - O+ - - N- + - CAM 9 10 11 12 13 14 15 16 DATA - - - - - - - - O:RESULT OK +:DATA EXISTENCE N:RESULT NG -:DATA NOTHING CAUTION:ALL ALARM INPUTS HAVE BEEN DISABLED. ALL RESET SELECT ALL-RESET NO CAUTION:ALL ALARM INPUTS HAVE BEEN DISABLED. Camera Upload This item lets you upload camera setup data from the Video Multiplexer’s memory to a camera. 1. Move the cursor to the CAM UPLOAD parameter in the SETUP MENU. 2. Select YES by pressing the LEFT or RIGHT but- ton, then press the SET button. The CAM UPLOAD table shown below appears on the monitor screen. 3. Select the channel you want to edit by pressing the LEFT or RIGHT button. 1CH - 16CH:Enables data uploading to a selected camera. ALL:Enables data uploading to all cameras. Note:Channel numbers can also be input directly with the Camera Number Buttons. 4. Move the cursor to “NO” by pressing the UP or DOWN button. 5. Select “YES” by pressing the LEFT or RIGHT button. 6. Press the SET button to begin the load. “NOW LOADING” appears on the table. To cancel loading, press the SETUP/ESC but- ton. 7. When loading is finished, the result is displayed for each channel. 8. Press the SETUP/ESC button, then system will restart. Note:Alarm is disabled while this menu is dis- played. All Reset This item lets you restore the factory settings without having to go through each individual menu. 1. Move the cursor to ALL RESET SELECT on the SETUP MENU, then press the SET button. The ALL RESET SELECT menu shown below appears on the monitor screen. 2. Select “YES” by pressing the LEFT or RIGHT button. 3. Press the SET button to execute the All Reset function. 4. First “NOW RESETTING” appears, then “RESET COMPLETED”. 5. Press the SETUP/ESC button to return to the SETUP MENU. Note: Alarm is disabled while the ALL RESET menu is displayed.
-38- OPERATING PROCEDURES VCR CAM SPOT ENTRANCE STILL SEQUENCE MULTI SCREEN STILL MONITOR CONTROL FUNCTION Before starting the following procedures, all system components should be turned on. Then set the LOCK switch to the OFF position. Operating the Spot Monitor The following operations are available on the Spot Monitor. Displaying the Camera Picture 1. Single Spot 1. Press the SPOTbutton. The LED (green) on the button lights up. 2. Press a CAMERA (1 - 16)button to display a selected camera picture on the monitor screen. The LED on the selected CAMERA button lights up. 2. Spot Sequence 1. Press the SPOTbutton. The LED (green) on the button lights up. 2. Press the SEQUENCEbutton to activate the sequence (SEQ1) programmed. The LED on the SEQUENCE button lights up. Note:Refer to the Sequence Setup on page 31 for more details. 3. Press the SEQUENCEbutton to move one step for- ward in the sequence. 4. To cancel the sequence, press the respective CAMERAbutton again. The selected camera picture is displayed in spot mode. Operating the Multiscreen Monitor The following operations are available on the Multi- screen Monitor. Note:We recommend to use the Single Spot when displaying non-interlace pictures, for instance, the Menu screen of the WJ-SX550, to prevent picture disturbance. Displaying the Camera Picture 1. Single Spot 1. Press the MULTISCREENbutton. The LED (green) on the button lights up. 2. Press the VCR/CAMbutton to CAMposition (LED off). 3. Press a CAMERA (1 - 16)button to display a selected camera picture on the monitor screen. The LED on the selected CAMERA button lights up. 2. Single Still 1. Repeat the step 1 - 3 described above for Single Spot. 2. Press the STILLbutton to freeze the displayed pic- ture. The LED on the STILL button lights up, and the LED on the pressed CAMERA button starts to blink. The camera title and “STILL” (both blinking) alter- nate in the display. 3. To cancel the still picture, press the STILLbutton again. The selected camera picture is displayed in spot mode.