Ventilating fan 11 Installation (Between joist mounting installation) continued 4.Insert the fan body between joists. Make sure the fan body is level and square (perpendicular) with the joists. Keep the flange and joists on same level. 5. Secure the installation bracket III to ceiling joist using long screws (M4X30). 6. Secure the fan body to ceiling joists using long screws (M4X30) in horizontal direction with installation bracket I and IV. III CAUTION: (Fig. 21) (Fig. 20)...
Page 12
Installation (Between joist mounting installation) continued III 12 7. Secure installation bracket I and IV to the fan body using short screw I (M4X12) and short screw II (M4X10). 10. Finish ceiling work. Ceiling hole should be cut at the edge of the frame. (Fig. 22) Fig. 24 8. Slide the circular duct onto the adapter and secure with tape.Remove the junction box cover and secure conduit to junction box knockout hole.(7/8 inch) Refer to wiring diagram on page 6. Using wire...
Page 13
Plug connector Plug connector Installation (Between joist mounting installation) continued III 13 11. Insert a spacer to metal plate of the fan case and three spacers to the light unit. 14. Insert the lamp cover to the grill and attach the grill to the fan unit. (Fig. 25) Fig. 25 Fig. 26 Fan case Light unitSpacer Long screws Receptacle II Plug connector III Plug connector II Receptacle III (Fig. 27) Night lamp Spacer Insert the fluoresceut lamps and screw the night lamp into the...
Page 14
14 Installing the ventilating fan in an existing construction requires an accessible area (attic or crawl space) above the planned location or existing ducting and wiring.To install the ventilating fan, follow the procedures described in Installation I. Inspect duct work and wiring before proceeding with installation. Plan suitable location for ventilating fan. (next to ceiling joist). Before installation, provide inspection and maint- enance access at a location that will not interfere with...
Page 15
15 Maintenance (Cleaning)II Disconnect power source before working on unit. Routine maintenance must be done every year. 1. Never use gasoline, benzene, thinner or any other similar chemicals for cleaning the grille and the ventilating fan. 2. Do not allow water to enter motor. 3. Do not expose plastic parts to temperature over 140 F (60 C). Remove grille. (Squeeze mounting spring and pull down)Wash and clean grille. (Use non-abrasive kitchen detergent) Remove dust and dirt from fan body using a...
Page 16
5770 Ambler Drive, Mississauga, ON L4W 2T3 www.panasonic.ca 16 Product service The unit should be serviced by qualified technicians only. No service information is provided for customers. Your product is designed and manufactured to ensure a minimum of maintenance. However, should your unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your products warranty. (In the U. S.A., call 1-866-292-7292 to locate the...