    Have a look at the manual Panasonic Ventilating Fan Fv 07vql3 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Ventilating fan
    11
    Installation 
       (Between joist mounting installation) continued
    4.Insert the fan body between joists.
        Make sure the fan body is level and square (perpendicular) 
       with the joists.
       Keep the flange and joists on same level.
    5. Secure the installation bracket III to ceiling joist using
        long screws (M4X30).
    6. Secure the fan body to ceiling joists using long screws
        (M4X30) in horizontal direction with installation bracket
        I and IV.
    III
    CAUTION:
    (Fig. 21) (Fig. 20) (Fig. 19)
    Joist spacing A should be between 350mm (13 7/8)
    and 430mm (17).
    Dont fix the junction box flap to the ceiling joist in this 
    installation.
    Fig. 19
    4-Long screws
    Installation bracket I
    Installation bracket IV
    Ceiling joist
    Installation bracket III
    Ceiling joist Ceiling joist
    junction box flap
    Ceiling joistCeiling joist
    Adapter
    1.
    2.
    Fig. 20
    Fig. 21
    A350-430mm
    (13 7/8-17) 
    						
    							Installation 
       (Between joist mounting installation) continued
    III
    12
    7. Secure installation bracket I and IV to the fan body using
        short screw I (M4X12) and short screw II (M4X10).
    10. Finish ceiling work. Ceiling hole should be cut at the edge
          of the frame.
    (Fig. 22)
    Fig. 24
    8. Slide the circular duct onto the adapter and secure with 
         tape.Remove the junction box cover and secure conduit 
        to junction box knockout hole.(7/8 inch)
        Refer to wiring diagram on page 6.
        Using wire nuts, connect house power wires to ventilating
        fan wires:
        Black to blacks; white to whites; green to greens.
        Replace junction box cover. 9.
    Mount junction box cover carefully so that lead wires 
    are not caught.
    CAUTION:
    (Fig. 3)
    (Fig. 24)
    Adapter
    Junction box coverCircular duct
    (Fig. 23)
    Fig. 23
    Short screw II
    Installation bracket I
    Installation bracket IV
    Ceiling joist Short screw I
    Fig. 22
    Conduit
    Flange
    Ceiling
    235
    235(9.25)
    (9.25) 
    						
    							Plug connector Plug connector
    Installation 
       (Between joist mounting installation) continued
    III
    13
    11.  Insert a spacer to metal plate of the fan case and
           three spacers to the light unit.
    14. Insert the lamp cover to the grill and attach the grill
           to the fan unit.
    (Fig. 25)
    Fig. 25
    Fig. 26
    Fan case
    Light unitSpacer
    Long screws
    Receptacle 
    II
    Plug connector 
    III
    Plug connector 
    II
    Receptacle 
    III
    (Fig. 27)
    Night lamp
    Spacer
    Insert the fluoresceut lamps and screw the night lamp 
    into the light unit.
    (Fig. 26)
    Light unit
    Fluorescent lamp
    Fig.27
    Mounting spring Light unit Slot
    GrilleLamp Cover
    Grille
    13.
    Insert the plug connector II and  plug connector III
    (Fig. 26)
     into the receptacle II and receptacle III respectively. 
    Attach the light unit to the fan unit by 4 long screws
    (M4x30). 12. 
    						
    							14
    Installing the ventilating fan in an existing construction 
    requires an accessible area (attic or crawl space) above 
    the planned location or existing ducting and wiring.To install the ventilating fan, follow the procedures 
    described in Installation I.
    Inspect duct work and wiring before proceeding
    with installation.
    Plan suitable location for ventilating fan. (next to 
    ceiling joist).
    Before installation, provide inspection and maint-
    enance access at a location that will not interfere
    with installation work shown in Installation I.
    Remove ceiling section according to Fig. 4 on 
    page 6.
    Install ventilating fan. 1.
    2.
    3.
    4.
    5.
    6.
    2.Disconnect the connector II or connector III of light
    unit.
    Fig. 28 Fig. 30Fig. 29
    Slot
    Mounting spring
    Grille
    1.
    Remove grille. (Squeeze mounting spring and pull down)
    (Fig. 28)
    Gloves
    (Fig. 29)
    ConnectorIII
    ConnectorII
    (Fig. 30)
    Change the fluorescent bulbs (Panasonic FDS 13E 
    27.U/2, 13W or FQ13E 41.U/2, 13W or FQ13E 35.U/2, 
    13W) or the 4W incandescent lamp, connect the connector 
    II or connector III and replace the grille. 3.
    Installation     (In existing construction)IV
    Maintenance   (Replacement of fluorescent lamp or night lamp)I
    Check area above planned installation location to be 
    sure that:
    Duct work can be installed and that area is sufficient
    for proper ventilation.
    Wiring can be run to planned location.
    No wiring or other obstructions will interfere with
    installation.
    CAUTION:
    1.
    2.
    3.
    1.
    Disconnect power source before working on unit.
    The lamps glass is fragile. Please handle with
    care. To remove lamp, grasp at base and move
    back and force to loosen.
    Do not pull hard on the lamp or you may break the
    glass.
    4W night lamp has threaded base. Remove by
    turning counterclockwise.
    WARNING:
    2.
    3. 
    						
    							15
    Maintenance   (Cleaning)II
    Disconnect power source before working on unit. Routine maintenance must be done every year.
    1. Never use gasoline, benzene, thinner or any other similar chemicals for cleaning the grille and the
        ventilating fan.
    2. Do not allow water to enter motor.
    3. Do not expose plastic parts to temperature over 140  F (60  C).
    Remove grille. (Squeeze mounting spring and pull down)Wash and clean grille. (Use non-abrasive kitchen
    detergent)
    Remove dust and dirt from fan body using a vacuum 
    cleaner. (Remove bulbs if necessary.)Using a cloth dampened with kitchen detergent,
    remove any dirt from fan body. Wipe dry with new
    cloth.
    Replace bulbs and grille.
    WARNING:
    CAUTION:
    1.2.
    (Fig. 31)
    (Fig. 32)
    (Fig.33)
    (Fig. 27)
    4.
    Fig. 32
    Fig.34 Fig. 33
    Vacuum cleaner
    Fig. 31
    Slot
    Mounting spring
    Gloves
    Grille
    3.
    5.(Fig. 34) 
    						
    							5770 Ambler Drive, Mississauga, ON L4W 2T3
    www.panasonic.ca
    16
    Product service
    The unit should be serviced by qualified technicians only. No service information is provided for customers. Your
    product is designed and manufactured to ensure a minimum of maintenance. However, should your unit ever
    require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE
    CENTERS is maintained to support your products warranty.
    (In the U. S.A., call 1-866-292-7292 to locate the Panasonic Authorized Service Center nearest you.)
    PANASONIC CONSUMER ELECTRONICS COMPANY
    PANASONIC CANADA INC.
    One Panasonic Way, Secaucus, NJ, 07094 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Ventilating Fan Fv 07vql3 Installation Instructions