Panasonic Ventilating Fan Fv 07vql3 Installation Instructions
Have a look at the manual Panasonic Ventilating Fan Fv 07vql3 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Ventilating Fan/Light Combination FV-07VQL3 FV-08VQL3 FV-11VQL3 INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Please read instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan/Light Combination. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. Table of Contents List of components Description Dimensions Specifications Unpacking General safety Information Installation I (Joist mounting Installation) Installation II (Wooden header Installation) Installation III (Between joist mounting Installation) Installation IV (ln existing construction) Maintenance I (Replacement of fluorescent lamp or night lamp) Maintenance II (Cleaning) Product Service 2 2 2-3 3 3 3-4 5-8 9 10-13 14 14 15 16 Pages
List of components These Panasonic ceiling mount ventilating fan models use a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The light unit is an energy-saving, lighting device which uses two 13W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp. 2 FV-07VQL3, FV-08VQL3, FV-11VQL3Unit: mm (inch) FV-07VQL3, FV-08VQL3, FV-11VQL3 Grille Long screw (M4 x 30)1 10 2 1 1 1 12 1 2 2 3 1 1 4 13W Fluorescent Lamp Plastic screw (M4 x 13) 4W incandescent lamp Spacer * Short screw (M4 x 12) 6 200 (7 7/8)45 (1 7/8) 22 (7/8) 16.5 (5/8)79(3 1/8) 117(4 5/8) 350 - 430(13 7/8 - 17) 550 - 640(22 - 25)34 (1 1/8) 32 (1 1/4)15 350 - 430(13 7/8 - 17) 45 (1 3/4) 11 10 Lamp cover1 Description Dimensions ** Installation bracket * Installation bracket Light unit Installation bracket * Thumb screwScrew (M4 x 6) * Part name DrawingQuantity Short screw (M4 x 10) **Part name DrawingQuantity ** Installation bracket * () 230 9() ( ) 1084 1/4 94 0 0 3 11/16 ()11 0 0 4 3/8 0 73 (2 7/8) 5 3 17
Dimensions continued 3 Specifications * At 0.0 Static pressure, (Pa) Unpacking Unpack and carefully remove unit from carton. Refer to the Supplied components list to verify that all parts are present. General safety information Do not install this ventilating fan/light combination in ducts where air temperature may exceed 104 F. (40 C) Make certain that the electric service supply voltage is 120V 60Hz. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Always disconnect the power source before working on or near the fan, motor or light fixture. 1. 2. 3. 4. Grille Junction box Junction box cover Body Damper Night lamp connector 13W lamp connector 1 3 4 5 6 8 9Motor connector 715Lamp cover 16 Night lamp 17Bracket cover Adapter 2 14 Fluorescent lamp (13W x 2) 10 13 Light unit 12 Thumb screw (4W x 1) ModelAir direction V HzPower consumption* (W) Fan unitLight unit Speed* (RPM)Air deliver at 0.1WG (CFM)Weight lb.(kg) 17.4 (7.9) 70 90 11 0 725 875 995 26 26 26 18 20 26 60 120 Exhaust FV-07VQL3 FV-08VQL3 FV-11VQL34 4 4 No.Part name No.Part name 11Installation bracket , *** Installation bracket *,* Fluorescent lampNight lamp 105(4 1/4) 1 14 16 7 8 9 13122 4268 (10 5/8 ) 330 (13 ) 228 (9 )
Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals, or other objects. Do not kink the power cord. Do not install the unit where ducts are configured as shown in Fig. A. Provide suction parts with proper ventilation. This unit is acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit. General safety information continued Fig. A CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig. B) 3. This product must be grounded. WARNING: Do not install this equipment in heating or air conditioning, air processing, or any other recirculated air ductwork. 4 5. 6. 7. 8. 9. WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following; Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards,including fire-rated construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. Do not use this unit with any solid-state control device. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. NEVER place a switch where it can be reached from a tub or shower. Do not insulation rated greater than R40. A. B. C. D. E. F. G. H. I. J. (Cooking area) Do not install above or inside this area. Cooking equipmentFloor Fig. B 4545
5 Remove junction box cover and secure conduit to junction box knockout hole.(7/8 inch) Refer to wiring diagram. Using wire nuts, connect house power wires to ventilating fan wires: black to blacks; white to whites; green to greens. Replace junction box cover.Remove adapter from body and fix to ceiling joists using long screws (M4X30). Slide the installation bracket *into slot next to the junction box. If longer extension is needed, assemble brackets*and*as shown below. Secure the angular end of the bracket to the ceiling joist. (See Fig.2.) Make sure the adapter is level and square (perpendicular) with the joists. Keep the distance B (21.6mm,0.85 inch) for the thickness of ceiling board. (Fig.2) (Fig.3) I CAUTION: Remove the bracket cover by loosening 4 (M4x6) screws before installation (Fig.1) Fig. 1 Fig. 2 (Fig.3) Fig. 3 Bracket cover (Fig.1) Disconnect plug connector from receptacle before starting installation. Lead wiresConduit B Installation (Joist mounting installation) 1. 2. Installation bracketII ScrewI Installation bracketI 3. 4. (M4x6) Screw Plug connector Screw driver Receptacle Junction box Ceiling joistInstallation bracketAdapter Long screw Ceiling joist Ceiling joist Fan body Duct Junction box cover Junction box Wire nut Green wires Separate connectionLump-sum connection
6 Installation (Joist mounting installaton) continuedI Slide 4 dia. duct onto adapter and secure with tape. Remove ceiling section. (Fig.4) 5. When connecting the light unit and the fan unit to the different power sources, connect the conduit to their respective junction box shown in Fig. 3 on page 5 and connect the wires according to the wiring diagram. NOTE Fig. 4 Wiring Diagram 6. Night Lamp Fan unit Red Black MotorCapacitor Black White Green Green Ballast Light unit Lamp Lamp Power supply AC 120V 60 Hz Earth ground Junction box Ballast WARNING: Make all electrical connections in accordance with the National Electric Code (NEC) and all local electrical codes. CAUTION: Mount junction box cover carefully so that lead wires are not caught. Ceiling joist mm (inches) 235 235 Adapter Ceiling (9.25) (9.25) Tape Duct Adapter Two 2-pin sockets (white and black) is used in the light unit. A 3 pin socket (white,black and green) is used in the fan unit. Connect the earth grounding wires (green) first. Black WhitePower Supply AC120V 60Hz
7 Installation (Joist mounting installaton) continuedI IMPORTANT: Make sure that body Claws are properly inserted into adapter slots. In case body and blower are installed separately. Remove 3 screws. Remove blower section. Insert fan body into ceiling. Mount blower section and fix with 3 screws. IMPORTANT: Make sure that frame is properly inserted into groove of blower section.Secure fan body to adapter using two thumb screws. 8.7. (Fig.6-1) (Fig.6-2) (Fig. 5) (Fig.6-3)(Fig. 5) Insert fan body into ceiling. Fig. 6-1 Fig. 6-2 Fig. 6-3Fig. 5 Fig. 7 (Fig. 7) Ceiling Body Claws Adapter slots Thumb screws Groove Frame sectionFrame section Blower sectionScrews Blower Claws Tape Duct Frame section Ceiling
Fluorescent lamp Light unit Plastic screws Ceiling 8 Installation (Joist mounting installaton) continuedI Insert plug connector I to receptacle I. (Fig. 8) 9. Insert the plug connector II , plug connector III into the receptacle II, receptacle III respectively, and attach the light unit to the fan unit with 3 plastic screws (M4X13) and one short screw I (M4x12) . Insert the fluorescent lamps and screw the night lamp into the light unit. (Fig. 10) 11 . 12. Insert the lamp cover to the grille and attach the grille to the fan unit. (Fig. 11) 13.Fix fan body to ceiling joists using long screws (M4X30) in horizontal or vertical direction. (Fig. 9) 10. Receptacle II Plug connector III Receptacle III(for 13w lamp) Plug connector II Receptacle III 4W Night Lamp Receptacle II(for night lamp)Receptacle I(for fan)Fig. 8 Fig. 9 Fig.10 (Fig. 10) Plug connectorFan Ceiling Plug connector Plug connector Short screw Fig.11 I Mounting spring Light unit Slot GrilleLamp Cover Grille
Ventilating fanAdapter Long screws Ceiling Flange Fig. 14 Fig. 15 9 Installation (Wooden header installaton)II Before installation, secure adapter to fan body using two thumb screws. Install header between ceiling joists using nails or screws. Secure the Fan/Light assembly to the header with long screws (M4X30). Slide the 4 circular duct onto the adapter and secure with tape. Remove the junction box cover and secure conduit to junction box knockout hole. (7/8 inch) Refer to wiring diagram. Using wire nuts, connect house power wires to ventilating fan wires: black to blacks; white to whites; green to greens. Replace junction box cover. Wiring Diagram Finish ceiling work. Ceiling hole should be cut at the edge of the flange. Insert the lamp cover into the Grille and attach the grille to the fan unit. (Fig. 12) (Fig. 13) (Fig. 14) (Fig. 3) (Fig. 15) (Fig. 11) 1. Mount junction box cover carefully so that lead wires are not caught. CAUTION: Junction box coverCircular duct Adapter When connecting the light unit and fan unit seperately, read the note on page 6 before making connections. Fig. 12 Fig. 13 3. 4. 5. 6. 7. 8. (Fig. 14) mm(inch) Thumb screwsLight unit Fan body Ceiling joist Header Ceiling joist 235 (9 1/4)345 (13 9/16) Night LampBlack WhitePower Supply AC120V 60Hz Earth ground Red Black Motor Capacitor White Green LampLampLight unit Ballast Black Fan unit Junction box Green Ballast Power supplyAC 120V 60 Hz Insert the plug connector II and plug connector III into the receptacle II and receptacle III respectively. Install the light unit to the fan body by using plastic screws (M4x13) and one short screw I (M4x12). Insert the fluorescent lamps and screw the night lamp into the light unit. 2. (Fig.10, Fig. 12)
Thumb screws 10 Installation (Between joist mounting installation) 1. Before installation, secure adapter to fan body by using two thumb screws. 2. Insert the installation bracket III into slot of the adapter side. III (Fig. 16) (Fig. 17) Fig. 18installation bracket I installation bracket IV Frame Fig. 16 3. Insert the installation brackets I and IV into slot. (Fig. 18) Fig. 17 Fan body installation bracket III Fan body adapter