Panasonic Ventilating Fan Fv 07vql3 Installation Instructions
Here you can view all the pages of manual Panasonic Ventilating Fan Fv 07vql3 Installation Instructions. The Panasonic manuals for Ventilation are available online for free. You can easily download all the documents as PDF.
Page 1
Ventilating Fan/Light Combination FV-07VQL3 FV-08VQL3 FV-11VQL3 INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Please read instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan/Light Combination. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. Table of Contents List of components Description Dimensions Specifications Unpacking General safety...
Page 2
List of components These Panasonic ceiling mount ventilating fan models use a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The light unit is an energy-saving, lighting device which uses...
Page 3
Dimensions continued 3 Specifications * At 0.0 Static pressure, (Pa) Unpacking Unpack and carefully remove unit from carton. Refer to the Supplied components list to verify that all parts are present. General safety information Do not install this ventilating fan/light combination in ducts where air temperature may exceed 104 F. (40 C) Make certain that the electric service supply voltage is 120V 60Hz. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the...
Page 4
Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals, or other objects. Do not kink the power cord. Do not install the unit where ducts are configured as shown in Fig. A. Provide suction parts with proper ventilation. This unit is acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit. General safety information continued Fig. A CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and...
Page 5
5 Remove junction box cover and secure conduit to junction box knockout hole.(7/8 inch) Refer to wiring diagram. Using wire nuts, connect house power wires to ventilating fan wires: black to blacks; white to whites; green to greens. Replace junction box cover.Remove adapter from body and fix to ceiling joists using long screws (M4X30). Slide the installation bracket *into slot next to the junction box. If longer extension is needed, assemble brackets*and*as shown below. Secure the angular end of the...
Page 6
6 Installation (Joist mounting installaton) continuedI Slide 4 dia. duct onto adapter and secure with tape. Remove ceiling section. (Fig.4) 5. When connecting the light unit and the fan unit to the different power sources, connect the conduit to their respective junction box shown in Fig. 3 on page 5 and connect the wires according to the wiring diagram. NOTE Fig. 4 Wiring Diagram 6. Night Lamp Fan unit Red Black MotorCapacitor Black White Green Green Ballast Light unit Lamp Lamp Power supply AC...
Page 7
7 Installation (Joist mounting installaton) continuedI IMPORTANT: Make sure that body Claws are properly inserted into adapter slots. In case body and blower are installed separately. Remove 3 screws. Remove blower section. Insert fan body into ceiling. Mount blower section and fix with 3 screws. IMPORTANT: Make sure that frame is properly inserted into groove of blower section.Secure fan body to adapter using two thumb screws. 8.7. (Fig.6-1) (Fig.6-2) (Fig. 5) (Fig.6-3)(Fig. 5) Insert fan body into...
Page 8
Fluorescent lamp Light unit Plastic screws Ceiling 8 Installation (Joist mounting installaton) continuedI Insert plug connector I to receptacle I. (Fig. 8) 9. Insert the plug connector II , plug connector III into the receptacle II, receptacle III respectively, and attach the light unit to the fan unit with 3 plastic screws (M4X13) and one short screw I (M4x12) . Insert the fluorescent lamps and screw the night lamp into the light unit. (Fig. 10) 11 . 12. Insert the lamp cover to the grille and attach...
Page 9
Ventilating fanAdapter Long screws Ceiling Flange Fig. 14 Fig. 15 9 Installation (Wooden header installaton)II Before installation, secure adapter to fan body using two thumb screws. Install header between ceiling joists using nails or screws. Secure the Fan/Light assembly to the header with long screws (M4X30). Slide the 4 circular duct onto the adapter and secure with tape. Remove the junction box cover and secure conduit to junction box knockout hole. (7/8 inch) Refer to wiring diagram. Using...
Page 10
Thumb screws 10 Installation (Between joist mounting installation) 1. Before installation, secure adapter to fan body by using two thumb screws. 2. Insert the installation bracket III into slot of the adapter side. III (Fig. 16) (Fig. 17) Fig. 18installation bracket I installation bracket IV Frame Fig. 16 3. Insert the installation brackets I and IV into slot. (Fig. 18) Fig. 17 Fan body installation bracket III Fan body adapter