Home
>
Panasonic
>
Electronic Accessory
>
Panasonic Up/Down Wall Mount Kit, Up/Down Stand Kit UE-608030, UE-608031, UE-608032 Operating Instructions
Panasonic Up/Down Wall Mount Kit, Up/Down Stand Kit UE-608030, UE-608031, UE-608032 Operating Instructions
Have a look at the manual Panasonic Up/Down Wall Mount Kit, Up/Down Stand Kit UE-608030, UE-608031, UE-608032 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Operating Instructions Usage Moving the Stand Stowing the Projector Assembly Prepare to move the stand by carrying out the steps below. 1Disconnect the power cable from the power outlet. 2Move the projector. •While lifting the projector arm slightly, turn it clockwise or counterclockwise slowly, and move the arm so that it is made parallel with the elite Panaboard unit. Note •At the lowest point, the projector may come into contact with the unit. Rotate the arm away, so that the projector will not touch the unit. 3Attach knob B (with the board bracket attached) at the position shown in the figure and secure the projector arm. Note •The position of knob A varies depending on the projector used. 4Lower the elite Panaboard to the lowest point. Note •If the height of the entrance is less than 2 m (6 ft. 63/4in.), proceed with steps 1 and 2, and after having moved the projector, lower the height of the projector arm by following the steps below. 1Attach knob B to the top hole. 2Lift the projector arm slightly and remove knob A from the projector arm. (The position of knob A varies depending on the projector used.) 3Lower the projector arm to the position where knob B stops it. 4Attach removed knob A to the securing position, and secure the projector arm. Knob B Knob A Hole for Securing Projector Arm Knob B Knob A UE-608030_EN.book 11 ページ 2010年10月28日 木曜日 午後4時20分
12 Operating Instructions Usage Removing the Foot Reinforcing Assemblies While grasping the release lever on the back side of each foot reinforcing assembly, pull the assembly from the stand base. Notice •Before moving the stand, be absolutely sure to remove the foot reinforcing assemblies from the stand base. If the stand is moved with these assemblies still attached, it may catch on surrounding objects, cause somebody to trip over and/or cause injury. •In case of securing the foot reinforcing assemblies using the bolts, please contact your dealer. Moving the Stand First get somebody to help you. Then take hold of the frame on the elite Panaboard sides and protective cover of the stand, and move the stand together.Notice When moving the stand •Release the lock lever for each caster. •Before moving the stand, disconnect the plug of the table tap from the wall outlet. •Make sure that none of the cables are dragged along with the stand. •Be absolutely sure to have another person ready to help you move the stand. •Take care that none of the equipment placed on the table plate will fall off. •While moving the stand, the stowed projector will move out of your field of view so while moving the stand, take care not to allow the projector to bump into a wall, door or other individuals around you. After the stand has been moved, follow the steps below to return it to the condition in which it was before it was moved. 1Lock the stand’s casters. 2Turn the casters so that they point inwards. 3Re-attach the foot reinforcing assemblies. 4Return the knob currently in the hole for securing the projector arm to the hole on the board bracket. •If the height of the entrance is less than 2 m (6 ft. 63/4in.), perform step 1 to 4 in the note (page 11) in reverse. 5Move the projector in front of the elite Panaboard. 6Connect the power cord. •Readjust the projector as needed and align it with the screen. Foot Reinforcing Assembly Release Levers UE-608030_EN.book 12 ページ 2010年10月28日 木曜日 午後4時20分
13 Operating Instructions Appendix Appendix Troubleshooting Symptom Possible cause and solution Unusual sounds are heard while the elite Panaboard is moving up or down or the elite Panaboard feels extremely heavy when it is raised. Something may be wrong with the up/down unit. Stop using the elite Panaboard immediately, and contact your dealer. Even when the elite Panaboard is raised, it drops down under its own weight. The adjustment part for raising and lowering the elite Panaboard may be out of position. Contact your dealer and ask for a service engineer to conduct the adjustments again. UE-608030_EN.book 13 ページ 2010年10月28日 木曜日 午後4時20分
For Your Safety 14 Installation Manual For Your Safety Installation Manual (for qualified service personnel) •Request assembly of the units and wall mounting from your dealer. •Before constructing or installing the units, please read “Installation Manual (for qualified service personnel)” carefully. Panasonic System Networks Co., Ltd. cannot be held responsible for accidents or damage to property resulting from incorrect installation. •Please read “For Your Safety” (pages 4–6 and pages 14–15) carefully and install the units safely. •When installing the elite Panaboard on a wall or on the up/down unit, perform installation with 2 people. For Your Safety To prevent severe injury and loss of life, read this section carefully before using the unit to ensure proper and safe operation of your unit. The following graphic symbols are used in this Installation Manual. Notice Denotes a potential hazard that could result in serious injury or death. Denotes hazards that could result in minor injury or damage to the unit. These symbols are used to alert operators to a specific operating procedure that must not be performed. This symbol is used to alert operators to a specific operating procedure that must be emphasized in order to operate the unit safely. This symbol is used to alert operators to a specific operating procedure that must be performed carefully. WARNING CAUTION If the unit is hung on a wall, confirm the wall must be capable of supporting at least the following weight. 4,100 N (418 k gf) Do not alter the unit and install. Installing an altered unit can cause injury. Have the unit installed, removed and disposed of only by qualified service personnel. Be sure to use the specified parts for the installation. Otherwise, it may cause injury. Notes in the operating instructions or notes of labels on the unit should be observed. Safety check must be done by qualified service personnel after installing this option. WARNING UE-608030_EN.book 14 ページ 2010年10月28日 木曜日 午後4時20分
For Your Safety15 Installation Manual Safety Do not attach the electronic board to mortared walls. Accidental electric leakage from the mounting bolts securing the up/down unit to metal laths or wire laths can cause heat, smoke or fire. Confirm the bolts of the unit are certainly caught by the up/down unit by pulling the elite Panaboard after hanging the elite Panaboard on the up/down unit if the unit is mounted on a wall. Be sure to put on a glove to avoid injury. Do not remove the up/down locking plates until you are ready to attach the board and projector. If these plates are removed by mistake, the up/down part may spring up and cause injury. Lock the casters (when using the stand) both after installation has been completed and after the stand has been moved. If the stand is used with the casters unlocked, it may move or be overturned and/or cause injury. After completing the installation or moving the stand to another location, be absolutely sure to attach the foot reinforcing assemblies to prevent the stand from toppling. CAUTION Locking the casters (Push to lock) Be careful around the projector ventilation area, which becomes hot. Working in this area or touching nearby objects may cause injury. UE-608030_EN.book 15 ページ 2010年10月28日 木曜日 午後4時20分
Product Configuration 16 Installation Manual Produc t Configuration Packing Configuration The following units are required when using the up/down stand kit or up/down wall mount kit. Included Accessories The following items are provided in the packing boxes. Check that they are present and accounted for. ∫Up/Down Unit (UE-608030) Up/Down Stand Kit Up/Down Unit UE-608030 Stand Table Unit UE-608031 Short-Throw Arm Unit UE-608032 Up/Down Wall Mount Kit Up/Down Unit UE-608030 Short-Throw Arm Unit UE-608032 No.Part NameIllustrationQ’tyNo.Part NameIllustrationQ’ty 1Cable Holder A15Board Mounting Screw (M6)4 2Cable Holder B 26Board Bracket Fastening Screw (M5)6 3Hook and Loop Fastener17Board Bracket 4 4Operating Instructions1 Unit × 1 UE-608030_EN.book 16 ページ 2010年10月28日 木曜日 午後4時20分
Product Configuration17 Installation Manual ∫ Stand Table Unit (UE-608031) ∫ Short-Throw Arm Unit (UE-608032) No.Part NameIllustrationQ’tyNo.Part NameIllustrationQ’ty 8Bolt (M6 x 75 mm [215/16in.]) for Securing Left and Right Stands6=Collar for Securing Table Plate 4 9Collar for Securing Left and Right Stands6>Spring Washer for Securing Table Plate4 :Screw (M3 x 10 mm [13/32in.]) for Securing Protective Cover12?Flat Washer for Securing Table Plate 4 ;Flat Washer for Securing Protective Cover12@Nut for Securing Table Plate 4
Wall Mounting Construction 18 Installation Manual Wall Mounting Construction Checking the Wall Which method should be used to mount the up/down wall mount kit depends greatly on the structure of the wall. The system to be mounted on the wall is heavy (up to 84 k g [185.19 lbs] including the elite Panaboard and projector). Before proceeding with installation, therefore, consult with the building manager, maintenance engineer or designer to verify that the wall has a structure strong enough to support the weight of the system. For safety, install the elite Panaboard only after thoroughly understanding the type of walls, the appropriate types of screws and the construction method. I.Necessary Tools and Parts (not included with the up/down wall mount kit) Tools Required for Assembly Tools and Parts Required for Wall-Mounting Work Other Parts *Please choose local certified 4-Way Plug Adaptor. Notice •If necessary, have an extension cord ready. A total cable length (including extension cord) of approximately 5m (16ft. 427/32in.) is required. II.Checkpoints to be Observed While Working 1Work-Related Safety Precautions •Before mounting the up/down unit, read through the following points, and take care to avoid accidents. — Be absolutely sure to wear a hardhat, protective shoes, safety belt and other safety gear. — To ensure safety, be absolutely sure to do the work with another individual (= 2-person crew). — Before proceeding with the work, check that there are no other individuals around you. — To ensure that the work is accomplished safely and properly, make it a basic rule to strictly observe all other applicable aspects of safety control. — If there is a chance that the unit has ended up being deformed or damaged by unexpected impact while it was being transported and installed, do not install it without taking appropriate measures. Otherwise, it may fall off the wall. 10 mm ( 13/32in.) Wrench - - - 3 (Ideally, one of these should be a ratchet type of wrench.) 13 mm (1/2in.) Wrench - - - - - - - - - 1 4 mm (5/32in.) Allen Key - - - - - - - 1 Phillips Head Screwdriver - - - - - 1 Anchor- - - - - - - - - - - - - - - -4 M8 Bolt - - - - - - - - - - - - - - -4 Flat Washer - - - - - - - - - - - -4 Spring Washer- - - - - - - - - - -4 The specified pull-out strength is required per anchor. M8 anchor bolts are used when installing the up/down unit on the wall. (Specified pull-out strength: 5,197.5 N [530 k gf]) Drill Select the drill diameter specified for the anchors used. Measuring Tape / Level These are used to ensure that the holes drilled in the wall will be positioned precisely. Dust Pump This is used for cleaning purposes to ensure that no scraps or chips are left inside the holes. Note that the cleaning of the insides of the holes must be thorough because the drive bolts will be subject to a reactive force at the bottom of the holes. Torque DriverUse a torque driver whose torque can be specified. (Recommended tightening torque: 12.5 N•m [127 k gf•cm]) 5m (16ft. 4 27/32in.) Video Cable (D-sub Cable) 5 m (16 ft. 427/32in.) Power Cable3 m (9 ft. 101/8in.) 4-Way Plug Adaptor * (with 3-Conductor Ground, Magnet) UE-608030_EN.book 18 ページ 2010年10月28日 木曜日 午後4時20分
Wall Mounting Construction19 Installation Manual 2Concerning Installation •The up/down stand kit and up/down wall mount kit are for indoor use. They cannot be used outdoors. Neither can they be installed or used in the following kinds of places. — Places where they will be directly exposed to rain or water (including under the eaves of a house) — Places where chemicals are used such as swimming pools — Places with a lot of steam or grease such as manufacturing plants or kitchens, places with special environments such as those with combustible atmospheres — Seaborne or coastal places and places where corrosive gases are given off — Places subject to frequent vibrations such as in vehicles or ships (the up/down wall mount kit is not designed to be used in or on vehicles) — Places other than walls (this is applicable to the up/down wall mount kit) — Places where the operating temperature range of the elite Panaboard will be exceeded •To prevent deformation and discoloring, avoid installing the kits in places exposed to direct sunlight or near heating or cooling appliances, etc. •When carrying out the work, be absolutely sure to abide by the construction-related laws and other related ordinances of the country concerned. 3Concerning the Installation Surface •Mount the up/down unit in a stable location. The specified pull-out strength is required per anchor. M8 anchor bolts are used when installing the up/down unit on the wall. (Specified pull-out strength: 5,197.5 N [530 k gf]) •Avoid mounting the unit on a wall, which is not a principal st ructure component*, with a plasterboard, plywood or other such construction since these walls are weak. If mounting on such a wall is unavoidable, reinforce the wall adequately (by ensuring that its ultimate strength will be at least as great as the specified pull-out strength of the anchors). *Principal Structural Component This term refers to walls, pillars, floors, beams, roofs and staircases, and it excludes partition walls, stud walls, attached columns, raised floors, floors on the bottom-most levels of buildings, floors of revolving stages, secondary beams, pent-roofs, partial sub-staircases, outdoor staircases and other structural parts of a similar nature which are not crucial to the building from a structural point of view. 4Concerning the Screws and Bolts Used •When obtaining anchors and bolts locally, be absolutely sure that they satisfy the required specifications. •Do not use wood screws. 5Concerning the Tightening of the Screws and Bolts •Tighten the screws and bolts using the specified torque. Tightening them up using excessive torque will damage the screw threads, causing the unit to fall off the wall. Conversely, the screws will be loose if they are tightened up with insufficient torque. •The torque levels are specified, so use a torque driver to tighten up the screws and bolts. •The range in which the torque can be specified is limited for each torque driver. Refer to the recommended torque levels which are specified, and use the appropriate torque driver. •Do not use an impact driver or power driver whose torque is difficult to control since using such a driver may damage the screws and bolts. •Tighten the screws and bolts so they go straight in. 6Other Checkpoints •Make sure that the location is large enough to accommodate the elite Panaboard. Height: greater than 2,500 mm (8 ft. 27/16in.) Width: greater than 2,100 mm (6 ft. 105/8in.) •Make sure that the AC outlet is within 3 m (9 ft. 101/8in.) of where the system will be mounted and that it will not be behind the up/down unit and the elite Panaboard. •Make sure that the Operating Instructions of the elite Panaboard to be mounted on the wall are at hand. The Operating Instructions that are supplied with each elite Panaboard model describe how to install each elite Panaboard directly onto the wall and how to conduct the operation checks. UE-608030_EN.book 19 ページ 2010年10月28日 木曜日 午後4時20分
Wall Mounting Construction 20 Installation Manual Wall Types and Installation Procedures I.When the Wall is a Principal Structural Component (a concrete wall which is at least 120 mm [43/4in.] thick) Use the M8 bolts to mount the system on the wall. It is also necessary to provide anchors separately. The figure below shows the end mounting position of the up/down unit and the elite Panaboard vis-à-vis the hole positions. Check that there is enough space around the mounting position. Carefully read the instructions for the anchors which will be used, and check the correct hole diameters. Note •The above outline drawing for wall-mounting uses the UB-T880W as an example. The UB-T781 and other models have a smaller installation surface area than the UB-T880W so they can definitely be mounted if the space shown in the drawing is available. Wall-Mounting Construction Procedure 1Drill the two top holes in the wall. 2Fasten the anchors to the holes. 3Insert the M8 bolts into the top left and right anchors and tighten them up until they only protrude approximately 4 mm ( 5/32in.) from the surface of the wall. 4With the help of another individual, take the up/down unit out of its packing box, and hang it on the wall by engaging the elongated holes at the top of the pipe on the rear surface of the unit with the two bolts. 5With the up/down unit hanging on the wall, mark off the positions of the holes used to secure the bottom part of the unit, put the up/down unit down, and drill the two bottom holes in the wall. 6Fasten the anchors to the bottom holes. 2500 mm 438 mm 530~785 mm 335~785 mm (when the pin end stopper is released) 900 mm 2100 mm 951 mm A 100 mm 2,100 mm (6 ft. 1011/16in.) 951 mm (3 ft. 1 7/16in.) 2,500 mm (8 ft. 23/8in.)438 mm (1 ft. 51/4in.) 900 mm (2 ft. 11 7/16in.) 100 mm (315/16in.) 530 to 785 mm (1 ft. 87/8in. to 2 ft. 629/32in.) 335 to 785 mm (1 ft. 13/16in. to 2 ft. 629/32in.) (when the pin end stoppers are released) UB-T880W / UB-T781W •UB-T880: Above dimensions less 122 mm (413/16in.) •UB-T780 / UB-T781 / UB-T780BP: Above dimensions less 25 mm (31/32in.) ProjectorA Panasonic 420 mm (1 ft. 417/32in.) SANYO 567 mm (1 ft. 105/16in.) EPSON 410 mm (1 ft. 45/32in.) Optoma 389 mm (1 ft. 35/16in.) Acer 385 mm (1 ft. 35/32in.) BenQ 425 mm (1 ft. 423/32in.) Bolt Approx. 4 mm ( 5/32in.) Spring Washer Flat Washer (max. diameter of 16 mm [5/8in.]) UE-608030_EN.book 20 ページ 2010年10月28日 木曜日 午後4時20分