Page 31

31
Notes:
•Alarm display On/Off and Buzzer On/Off mode can be
selected. (See page 20 and 21.)
•The camera or receiver control can be continued even
when an alarm is generated.
Alarm Reset
Automatic or manual resetting can be selected.
When the alarm is reset, [ALARM] disappears from the
monitor screen and the alarm reset signal is output to the
time lapse VCR.
Automatic Reset
The alarm is automatically reset after the programmed
alarm output time has elapsed.
The alarm indicator changes from blinking...

Page 32

32
PRESET/SET/PROGRAM PRESET
To enter a submenu.
HOME/ESC button:
To return to the previous menu.
CAMERA SETUP
The camera setup operations are available using the WV-
CU161C controller on the CAMERA SETUP menus.
For further information, refer to the Operating Instructions
for the individual combination cameras.
Camera Setup
1. Hold down the CAMERA SETUP/SETUP/PROGRAM
button for 2 seconds or more to access the Camera
Setup menu. The CAMERA SETUPindicator lights up.
2. Select an item and parameter by...

Page 33

33
Camera Patrol Learning
There are two ways of setting the camera patrol learning.
One is to use the setup menu and the other is to operate
the camera.
Follow the procedures described below to set the camera
patrol learning up while operating the combination camera.
1. Press the PATROL LEARNbutton while holding down
the PROGRAMbutton. 
[LEARNING] appears on the monitor.
Note:Pressing the PROGRAM button alone for 2 sec-
onds will change the screen to the WV-CU161C
SETUP MENU or camera SETUP MENU.
2....

Page 34

34
The WV-CU161C System Controller can be reset to the
default settings as follows:
1. Turn off the Power Switch.
2. Turn on the Power Switch while simultaneously pressing
numeric buttons 2, 4and 6.
ALL RESET
3. Resetting has been completed when all LEDs light up
for a few seconds and then go off (except for the
Operate Indicator).
Note:The downloaded data for the camera remains as
it is.
123
46
789
0
5
PROGRAM
PRESET ESC HOME
SET PRESET 

Page 35

35
Power Source: 120 V AC, 60 Hz
Power Consumption:  6 W
Camera Input: Composite Video Signal: 1 V[p-p]/75 Ω
Alarm Input: No-voltage contact
Alarm Recover Input: No-voltage contact
Video Output: Composite Video Signal: 1 V[p-p]/75 Ω
Alarm Output: Open collector: 16 V DC, 100 mA max.
Alarm Reset Output: Open collector: 16 V DC 100 mA max.
Pulse (VCR): +5 V DC approx. 500 m sec. internally switchable
Data Input/Output: Equivalent to RS-485: 4-Line (Full-Duplex)/2-Line (Half-Duplex) switchable
Lens Control:...

Page 36

N1201-0 V8QA5895AN Printed in Japan
N19 2001 © Matsushita Communication Industrial Co., Ltd.  All rights reserved.Panasonic Canada Inc.
5770 Ambler Drive, Mississauga,
Ontario, L4W 2T3 Canada (905)624-5010
Panasonic Sales Company
Division of Matsushita Electric of Puerto Rico Inc.
Ave. 65 de Infanteria. Km. 9.5
San Gabriel Industrial Park, Carolina,
Puerto Rico 00985 (809)750-4300
Panasonic Security and Digital Imaging Company
A Division of Matsushita Electric Corporation of America
Executive Office:One...