    Have a look at the manual Panasonic System Controller Wv Cu161c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
    Notes:
    •Alarm display On/Off and Buzzer On/Off mode can be
    selected. (See page 20 and 21.)
    •The camera or receiver control can be continued even
    when an alarm is generated.
    Alarm Reset
    Automatic or manual resetting can be selected.
    When the alarm is reset, [ALARM] disappears from the
    monitor screen and the alarm reset signal is output to the
    time lapse VCR.
    Automatic Reset
    The alarm is automatically reset after the programmed
    alarm output time has elapsed.
    The alarm indicator changes from blinking to steady light,
    and [ALARM] disappears from the monitor screen.
    Press the ALARM RESET/SUSPEND button to turn off the
    steady light.
    Note:Alarm can also be reset by input of the alarm recover
    signal (no-voltage contact) from the time lapse VCR.
    The reset mode in this case is the same as for automat-
    ic reset.
    Manual Reset
    Press the ALARM RESET/SUSPENDbutton.
    The alarm indicator goes off, [ALARM] disappears from the
    monitor screen, and alarm is reset.
    Alarm Suspend
    The alarm suspension function allows you to suspend the
    alarm function while setting up the camera or the WV-
    CU161C.
    1. Press the ALARM RESET/SUSPENDbutton while the
    SHIFT indicator is lit.
    The ALARM SUSPENDindicator lights up.
    Alarm input is ignored while the ALARM SUSPEND indi-
    cator is lit.
    2. To cancel the alarm suspension, press the ALARM
    RESET/SUSPENDbutton while the SHIFT indicator is
    lit.
    The ALARM SUSPENDindicator goes off.
    ALARM CONTROL FUNCTIONS
    When the WV-CU161C receives an alarm signal from a
    camera site, an alarm is activated. The WV-CU161C can
    handle the following alarms.
    Camera Site Alarm
    Coaxial Multiplex Communication:
    Alarm is multiplexed with video signals from the cam-
    era.
    RS-485 Site Communication
    Alarm is transmitted via RS-485.
    Terminal Alarm
    Alarm is input via the alarm input terminal on the rear
    panel from external devices such as sensors.
    Alarm Operation
    [ALARM] appears on the monitor screen when the alarm
    signal is supplied in the Alarm On mode
    The alarm indicator starts to blink and the buzzer sounds.
    (ALARM BUZZER is preset to ON at the factory.)
    If the preset number is set for the ALARM PRESET or
    ALARM TERMINAL parameter in ALARM SETUP menu,
    then the camera moves to the preset position when an
    alarm is activated. The camera picture at that position is
    displayed on the monitor.
    The alarm output signal is supplied to the time lapse VCR
    until the alarm is reset.
    RESET
    SUSPENDALARMCharacter display
    (ALARM DISPLAY ON)
    ALARM
    RESET
    SUSPENDALARM
    SHIFT
    OPERATE ALARM
    ALARM
    Blinking: Alarm has been activated.
    Light on: Alarm has been reset automatically
    , 
    or by input signal from external devices 
    (when the alarm switch is in the upper position).
    Light off: Alarm has been reset manually, or the 
    ALARM RESET/SUSPEND button has
    been pressed while the alarm indicator is on. 
    						
    							32
    PRESET/SET/PROGRAM PRESET
    To enter a submenu.
    HOME/ESC button:
    To return to the previous menu.
    CAMERA SETUP
    The camera setup operations are available using the WV-
    CU161C controller on the CAMERA SETUP menus.
    For further information, refer to the Operating Instructions
    for the individual combination cameras.
    Camera Setup
    1. Hold down the CAMERA SETUP/SETUP/PROGRAM
    button for 2 seconds or more to access the Camera
    Setup menu. The CAMERA SETUPindicator lights up.
    2. Select an item and parameter by pressing numeric but-
    tons 2, 4, 6and 8.
    3. Press the PRESET/SET/PROGRAM PRESETbutton to
    execute the parameter or enter a submenu.
    4. Press the HOME/ESCbutton to return to the previous
    menu.
    5. Hold down the CAMERA SETUP/SETUP/PROGRAM
    button for 2 seconds or more to complete the Camera
    Setup.
       *** SET UP MENU ***
    PRESET 1*
     MAP 
     HOME POSITION
     SELF RETURN
     AUTO MODE
     AUTO PAN KEY
     DIGITAL FLIP
     LOCAL/REMOTE
     SPECIAL1
    CAMERA
    RS485 SET UP15
    10MIN
    AUTO PAN
    SEQ
    OFF
    LOCAL
    (Example of Camera Setup menu)
    CAMERA
    SETUP
    SETUP
    PROGRAM
    CAMERA
    SETUP
    SETUP
    PROGRAM
    123
    46
    789
    0
    5
    PROGRAM
    PRESET ESC HOME
    SET PRESET
    PROGRAM
    PRESETSET PRESET
    PROGRAM
    PRESETSET PRESETESC HOME
    Notes:
    •To display the special menu, move the cursor to [SPE-
    CIAL] on the setup menu and simultaneously hold down
    numeric buttons 4and 6for 2 seconds or more.
    •To restore all default values, move the cursor to [CAM-
    ERA RESET]* on the setup menu and simultaneously
    hold down buttons 4, 5and 6for 2 seconds or more.
    •The menu for restoring the camera defaults differs
    depending on the camera type.
    For example, [SPECIAL] for the WV-CS654, [SPECIAL
    2] for the WV-CS854, and [END] for fixed cameras.
    •If camera setup is started using the buttons on the cam-
    era, then all future setup operations must be performed
    with the buttons.
    If camera setup is started using the System Controller,
    then all future setup operations must be performed
    using the same controller.
    •For further information, refer to the Operating
    Instructions for the selected camera.
    Keys Used in the Camera Setup Menu
    CAMERA SETUP/SETUP/PROGRAM button:
    Hold down this button for 2 seconds or more to display
    the camera SETUP MENU.
    CAMERA
    SETUP
    SETUP
    PROGRAM
    ESC HOME
    Numeric buttons:
    To move the cursor.
    To select modes.
    28
    4
    6 
    						
    							33
    Camera Patrol Learning
    There are two ways of setting the camera patrol learning.
    One is to use the setup menu and the other is to operate
    the camera.
    Follow the procedures described below to set the camera
    patrol learning up while operating the combination camera.
    1. Press the PATROL LEARNbutton while holding down
    the PROGRAMbutton. 
    [LEARNING] appears on the monitor.
    Note:Pressing the PROGRAM button alone for 2 sec-
    onds will change the screen to the WV-CU161C
    SETUP MENU or camera SETUP MENU.
    2. Operate the camera using the following controls so that
    it traces the routine course that is the most frequently
    patrolled. The learning is programmed for 30 seconds.
    •Pan/Tilt (Joystick)
    •Iris (Open/Close)
    •Focus (Near/Far)
    •Zoom (Tele/Wide)
    •Preset position
    Note:The memorized parameters may differ somewhat
    depending on the camera type. Refer to the manual
    included with the camera.
    3. To stop the learning, press the PATROL STOPbutton
    while holding down the PROGRAMbutton.
    [LEARNING] appears on the monitor.
    LEARNING
    B/W AUTO
    PATROL STOP
    CAMERA
    SETUP
    SETUP
    PROGRAM
    Camera Preset Position
    There are two ways of presetting camera positions. One is
    to use the setup menu of the combination camera and the
    other is to operate the camera.
    Follow the procedures described below to set up the cam-
    era preset position while operating the combination cam-
    era.
    1. Move the camera to the position you wish to preset
    using the joystick. 
    Adjust the picture using the following controls.
    •Iris (Open/Close)
    •Focus (Near/Far)
    •Zoom (Tele/Wide)
    Note:The memorized parameters may differ somewhat
    depending on the camera type. Refer to the manual
    included with the camera.
    2. Type a number with the numeric buttons for the preset
    position. The typed number appears in the CAMERA
    section of the LED display.
    3. Press the PRESET/SET/PROGRAM PRESETbutton
    while holding down the CAMERA SETUP/SETUP/PRO-
    GRAMbutton.
    The position and its number are memorized for future
    recall.
    UP
    LR
    DOWN
    123
    46
    789
    0
    5
    PROGRAM
    PRESET ESC HOME
    SET PRESET
    PROGRAM
    PRESETSET PRESET
    CAMERA
    SETUP
    SETUP
    PROGRAM
    PATROL
    PLAY
    PATROL LEARN
    CAMERA
    SETUP
    SETUP
    PROGRAM 
    						
    							34
    The WV-CU161C System Controller can be reset to the
    default settings as follows:
    1. Turn off the Power Switch.
    2. Turn on the Power Switch while simultaneously pressing
    numeric buttons 2, 4and 6.
    ALL RESET
    3. Resetting has been completed when all LEDs light up
    for a few seconds and then go off (except for the
    Operate Indicator).
    Note:The downloaded data for the camera remains as
    it is.
    123
    46
    789
    0
    5
    PROGRAM
    PRESET ESC HOME
    SET PRESET 
    						
    							35
    Power Source: 120 V AC, 60 Hz
    Power Consumption:  6 W
    Camera Input: Composite Video Signal: 1 V[p-p]/75 Ω
    Alarm Input: No-voltage contact
    Alarm Recover Input: No-voltage contact
    Video Output: Composite Video Signal: 1 V[p-p]/75 Ω
    Alarm Output: Open collector: 16 V DC, 100 mA max.
    Alarm Reset Output: Open collector: 16 V DC 100 mA max.
    Pulse (VCR): +5 V DC approx. 500 m sec. internally switchable
    Data Input/Output: Equivalent to RS-485: 4-Line (Full-Duplex)/2-Line (Half-Duplex) switchable
    Lens Control: Zoom: Tele/Wide
    Focus: Near/Far/Auto Focus
    Iris: Open/Close/Preset
    Pan/Tilt Control: Manual Pan/Manual Tilt: 8-directions, 8-steps/4-steps (slow) speed
    Auto Pan: On/Off
    Random Pan: On/Off
    Housing Control: Wiper: On/Off
    Defroster: On/Off
    AUX 1 - 2
    Camera Control: Position Select: Preset Position, Home Position
    Camera Patrol: Learn/Play/Stop
    Electronic Zoom
    Color/Black and white selectable
    Camera function
    Camera Setup
    Camera Data Upload/Camera Data Download (Up to eight video cameras)
    Alarm: Alarm Buzzer: On/Off
    Alarm Title Display: On/Off
    Auto Alarm Reset/Manual Alarm Reset
    Alarm Suspension/Alarm Suspension Reset
    Ambient Operating Temperature:–10˚C - +50˚C (14˚F - 122˚F)
    Ambient Operating Humidity:  Less than 90 %
    Dimensions: 330 mm (W) x 74.5 mm (H) x 221 (D) mm
    13” (W) x 2-15/16” (H) x 8 11/16” (D)
    Weight: 2.4 kg(5.3 lbs.)
    Dimensions and weight are approximate.
    Specifications are subject to change without notice.
    SPECIFICATIONS 
    						
    							N1201-0 V8QA5895AN Printed in Japan
    N19 2001 © Matsushita Communication Industrial Co., Ltd.  All rights reserved.Panasonic Canada Inc.
    5770 Ambler Drive, Mississauga,
    Ontario, L4W 2T3 Canada (905)624-5010
    Panasonic Sales Company
    Division of Matsushita Electric of Puerto Rico Inc.
    Ave. 65 de Infanteria. Km. 9.5
    San Gabriel Industrial Park, Carolina,
    Puerto Rico 00985 (809)750-4300
    Panasonic Security and Digital Imaging Company
    A Division of Matsushita Electric Corporation of America
    Executive Office:One Panasonic Way 3E-7, Secaucus, New Jersey 07094
    Regional Offices:
    Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303
    Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838
    Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211
    Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic System Controller Wv Cu161c Operating Instructions