0017#-(0 or l)# 
SMDR TIMER - STARTING TIME DISPLAY FOR OUTSIDE CALLS 
The start time for an outside caII appears on the display 15 seconds after the dial 
signal is sent out. The 15-second default can be reset to 30 seconds. 
The start time for an incoming calI appears on the display immediately after the 
c~. is’ .answered.. -- -. 
O#: 15 seconds 
l#: 30 seconds 
OOlS#-(0 or l)# 
FLASH - REDIAL [AUTOMATIC) 
The REDIAL key can...

Page 72

S-DBS Progra.mming Instructions 
v1.0 Section 400 
Issue 1 July 1990 
0020#-(Owl-4)# 
SSD STORED OUTSIDE LINE FbISH TIMER 
Sets the timer to temporarily release the outside line by pressing the FLASH key. 
O#: 0.5 second 
l#: 1 second 
2#: 1.5 seconds 
3% 2 seconds 
4#: 3 seconds 
DIAL PAUSE TIMER - OUTSIDE LINE 
After making an outside line call and hanging up there is a timed pause before 
you can dial out to make a second call. 
0#: 0.75 second 
l#: 1 second 
2#: 2 seconds 
3#: 4 seconds 
4#: 6...

Page 73

Section 400 
Issue 
1 July 1990 S-DBS Programn@@ns~c&~~~~ 
V1.O 
0023#-(0.1 or 2)# 
PULSE DIAL MINIMUM PAUSE 
Sets a pause between digits dialed during.puIse dialing. 
0#: 640 ms 
l#: 752 ms 
0024#-m# 
d 
SWITCHING TIME FOR NIGHT MODE (AUTOMATIC) 
You can set the system, so that it switches automaticaIIy from day mode to night. 
Enter the time using the 12-hour system followed by 1 for AM. or 2 for P.M.: 
8:02.P.M. = 08022 
12:00kM.= 12001 
._ 11:59kM.=11591 
CONF #: Remains in dav mode 
HHMMN#:...

Page 74

S-DBS Progr amming Instructions 
v1.0 Secaori ‘4330 
Issue 1 July 1990 
0026#-(0 or l)# 
ONE-TOUCH KEY 
You can dial stored telephone numbers and SPD codes by pressing a single key if 
the system is programmed for One-Touch Call. 
0#: One-touch call not possible 
l#: One-touch call 
0027#-(0 or l)# 
__ _..---.. ..___ . 
BACKGROUND MUSIC (BGM) d 
O#: BGM disabled 
l#: BGM enabled 
0628#-(O.l-3)# 
INFORMATION TONE FOR VOICE CALLING 
Sets the information or splash tone for extensions called by voice. The...

Page 75

Section 400 
Issue 1 July 1990 S-DBS Programming Instnxtions 
v1.0 
0030#-(0 or l)# 
STATION LOCKOUT ID CODE 
Displays the ID code on an LCD telephone. 
O#: ID code not disnlaved 
l#: ID code displayed 
0031#-(0 or l)# 
SSD DISPLAY RESTRICTION (80-89) 
4 
Sets the system to display telephone numbers durin 
an SSD call and REDIAL. If 
SSD calls are programmed not to display, then redi 
zf 
not displayed either. ed telephone numbers are 
O#: Number not disnlaved 
l#: Number displayed 
NOTE: AUTO (00-79)...

Page 76

S-DBS Prograxnmi.ng Instructions 
v1.0 Section 400 
Issue 1 July 1990 
0033#-(0, P-7)# 
EXTENSION HOLD RECALL TIMER 
A recall warning tone sounds to indicate that an outside line ca.U has not been 
answered within a specified time after being put on HOLD from an extension other 
than the attendant’s nhone. 
Set the hold recall timer at between 20-180 seconds. 
O#: No recall 
l#: Recall 20 seconds 
2#: Recall 40 seconds 
3#: Recall 60 seconds 
a 
_.----._ -__- ___---__ _- .-.. -. -. 
6#: Recall 150...

Page 77

Section 400 
Issue 
1 July 1990 S-DBS Programming Instruct+oln. 
. 
0035#-(0,1-5)# 
SLT ON-HOOK (AUTOMATIC) DETECTION TIMER 
Set the line flash on an SLT to either Line FLASH or disconnect when the hook 
button is pressed lon er or less than the time set for a Iine 
FLASH. (referred to as 
the hooking operation. 
4 
No Detection Line Flash Disconnect 
O#: No detection 
l#: Less than 250ms 
2#: Less than 250ms 
3#: Less than 250ms 
4#: Less than 250ms 
5#: Less than 250ms 250 - 500 ms Over 500 ms 
250 -...

Page 78

S-DBS Programming Instructions Section 400 
v1.0 Issue 1 July 1990 ‘;.. -.. 
0038#-(0, I-4)# 
CPC SIGNAL TIMER - SLT EXTENSION LINE 
The CPC signal is a disconnect signal sent to the SLT. 
O#: No signal 
l#: 0.25 second 
2#: 0.50 second 
3#: 0.75 second 
4#: 1 second 
0039#-(0 or l)# 
DOOR BOX SPEECH PATH -- -- 
The 308 system has 2 analog speech paths and the 616 system has 4 analog 
speech paths. 
door box only. One of these speech paths for each system can be set aside for the 
O#: No door box sneech...

Page 79

Section 400 S-DBS Programming Instnxtions 
Issue 1 July 1990 v1.0 
0042#-(0 or l)# 
MULTI-PURPOSE RELAY 2 FUNCTION 
O#: Multi-DurDose relav 2 
l#: Incoming ring signal 
0043#-(0 or l)# 
MULTI-PURPOSE RELAY 1 OPERATION 
O#: Relav oDerated as Droprammed time 
--.--. ----I# :’ Relay operate& continually 
0044#-(0 or l)# 
MULTX-PURPOSE RELAY 2 OPEMTION 
,,’ 
O#: Relav oDerated as DroErammed time 
l#: Relay operated continually 
MULTI-PURPOSE RELAY 1 OPERATION TIMER 
O#: 0.125 second 
. 
~--_- 
2#: 2 seconds...

Page 80

S-DBS programming Instructions 
v1.0 Section 400 
Issue 1 July 1990 
:_ 
MULTI-PURPOSE RELAY 2 OPERATION TIMER 
0% 0.125 second 
l#: 1 second 
2#: 2 seconds 
3#: 3 seconds 
4#: 4 seconds 
5#: 5 seconds 
6#: 6 seconds 
7#: 7 seconds 
. 
36  