Remote control operation ENGLISH - 61 Basic Operation Using the STATUS function You can display the status of the projector. button Press the button on the remote control. ▶zThe [STATUS] screen is displayed. Note z This can be displayed from the [PROJECT OR SETUP] menu → [STATUS] ( page 112). Using the Automatic setup function The automatic setup function can be used to automatically adjust the resolution, clock phase, and picture position when analog RGB signals consisting of bitmap images such as computer signals are being input, or to automatically adjust the picture position when DVI-D/HDMI signals are being input. It is recommended to supply images with a bright white border at the rims and characters with high contrast black and white when the system is in the automatic adjustment mode. Avoid supplying images that include halftones or gradation, such as photographs and computer graphics. button Press the button on the remote control or the control panel. ▶z [COMPLETE] is displayed when it has completed without any problem. Note z The CLOCK PHASE may shift even if it has completed without any incident. In such cases, adjust with the [POSITION] menu → [CLOCK PHASE] ( page 76). zIf an image with blurred edges or a dark image is input, [INCOMPLETE] may appear or adjustment m ay not be performed properly even if [COMPLETE] appears. In this case, adjust the settings in the [ADVANCED MENU] menu → [INPUT RESOLUTION] ( page 81), [POSITION] → [CLOCK PHASE] ( page 76), [SHIFT] ( page 74). z Adjust specific signals according to the [DISPLA Y OPTION] menu → [AUTO SETUP] ( page 94). z Automatic adjustment may not work depending on the model of the computer . z Automatic adjustment may not work for a synchronization signal of C-SY or SYNC ON GREEN. z Images may be disrupted for a few seconds during automatic adjustment, but it is not a malfunction. zAdjustment is required for each input signal. zAutomatic adjustment can be canceled by pressing the button during the automatic adjustment operation. zEven for an RGB signal for which automatic setup is possible, if automatic setup is performed while m oving images are being input, the adjustment may not be performed properly. Even if [INCOMPLETE] or [COMPLETE] appears, the adjustment may not be performed properly. Using the Function button [DISABLE], [P IN P], [SUB MEMORY], [SYSTEM SELECTOR], [SYSTEM DAYLIGHT VIEW], [FREEZE], [WAVEFORM MONITOR], [LENS MEMORY LOAD], or [LEFT/RIGHT SWAP] operations can be assigned to the button on the remote control so that it can be used as an easy shortcut button. button Press the button on the remote control. Note z [LEFT/RIGHT SWAP] can only be assigned in PT-DZ21KU, PT-DS20KU. z Assignment of the function is performed from the [PROJECT OR SETUP] menu → [FUNCTION BUTTON] ( page 114).
![](/img/blank.gif)
Remote control operation 62 - ENGLISH Basic Operation Displaying the internal test pattern The projector has eight types of internal test patterns to check the condition of the set. To display test patterns, perform the following steps. button 1) Press the button on the remote control. 2) Press the ◀▶ button to select the test pattern. Note z Setting is also available from the [TEST PATTERN] menu ( page 120). z Settings of position, size, and other factors will not be reflected in test patterns. Make sure to display the input signal before performing various adjustments. Changing the picture aspect ratio You can toggle through aspect ratios to select the one that is appropriate for the input signal. button Press the button on the remote control. zThe setting will change as follows each time you press the button. [VID AUTO]*1 [DEFAULT][THROUGH][16:9] [AUTO] *2 [HV FIT] [V FIT][H FIT][4:3] *1: Only for video signal and Y/C signal (NTSC) input *2: Only for RGB (480i or 480p) signal input Note z S ome aspect ratios may not be available depending on the input signal. Refer to [ASPECT] ( page 74) for details.
![](/img/blank.gif)
Menu navigation ENGLISH - 63 Settings Menu navigation Navigating through the menu ▶■Operating procedure button 1) Press the button on the remote control or control panel. ▶z The [MAIN MENU] screen is displayed. (17(5 0$,10(18 3,&785( 326,7,21 $9$1&(0(18 ,63/$
![](/img/blank.gif)
Menu navigation 64 - ENGLISH Settings ▶■To reset adjustment values to the factory default If the button on the remote control is pressed, the values adjusted in the menu items will be restored to the factory default settings. button Press the button on the remote control. &/2&.3+$6( $-867 Note zY ou cannot reset all the settings to the factory default at a time. z T o reset all the settings adjusted in the sub-menu item to the factory default at a time, perform initialization from the [PROJECTOR SETUP] menu → [INITIALIZE] ( page 117). z Some menu items cannot be reset by pressing the button. Adjust each item manually. z The triangular mark under the bar scale in the individual adjustment screen indicates the factory default setting. The position of the triangular mark varies by the selected input signals. &XUUHQWVHWWLQJ HIDXOWVHWWLQJ Main menu The following items are in the main menu. When a main menu item is selected, the screen changes to a sub-menu selection screen. Main menu item Page [PICTURE] 65 [POSITION]65 [ADVANCED MENU]65 [DISPLAY LANGUAGE]65 [3D SETTINGS]*165 [DISPLAY OPTION]66 [PROJECTOR SETUP]66 [P IN P]66 [TEST PATTERN]66 [SIGNAL LIST]66 [SECURITY]66 [NETWORK]66 *1: PT-DZ21KU and PT-DS20KU only
![](/img/blank.gif)
Menu navigation ENGLISH - 65 Settings Sub-menu The sub-menu of the selected main menu item is displayed, and you can set and adjust items in the sub-menu. ▶■[PICTURE] Sub-menu item Factory default Page [PICTURE MODE] [STANDARD]*167 [CONTRAST] [0] 68 [BRIGHTNESS] [0] 68 [COLOR] [2] *168 [TINT] [–2] 68 [COLOR TEMPERATURE] [DEFAULT] 68 [GAMMA] [DEFAULT] 70 [SYSTEM DAYLIGHT VIEW] [OFF] 70 [SHARPNESS] [8] 70 [NOISE REDUCTION] [2] 71 [DYNAMIC IRIS] [2] 71 [SYSTEM SELECTOR] [YP BPR]*172 *1: Depends on the signal input. Note z The factory default settings may vary depending on the picture mode. ▶■ [POSITION] Sub-menu item Factory default Page [SHIFT] — 74 [ASPECT] [DEFAULT] *174 [ZOOM] — 75 [CLOCK PHASE] [0] 76 [GEOMETRY] *2[OFF] 76 [KEYSTONE] *3— 78 *1: Depends on the signal input. *2: PT -DZ21KU and PT-DS20KU only *3: Only for PT -DW17KU ▶■[ADV ANCED MENU] Sub-menu item Factory default Page [DIGITAL CINEMA REALITY] [AUTO] *180 [BLANKING] — 80 [INPUT RESOLUTION] — 81 [CLAMP POSITION] [24] *181 [EDGE BLENDING] [OFF] 81 [FRAME RESPONSE] [NORMAL] 83 [FRAME LOCK] *2[OFF] 83 [RASTER POSITION] — 83 *1: Depends on the signal input. *2: PT -DZ21KU and PT-DS20KU only ▶■[DISPLA Y LANGUAGE] Details ( page 84) ▶■[3D SETTINGS]*1 Sub-menu item Factory default Page [3D SYSTEM SETTING] [SINGLE] 85 [3D SYNC SETTING] — 85 [3D SIMUL INPUT SETTING] — 86 [3D INPUT FORMAT] [AUTO] *287 [LEFT/RIGHT SWAP] [NORMAL] 87 [3D COLOR MATCHING] [SHARED 2D/3D] 87 [3D PICTURE BALANCE] — 88 [DARK TIME SETTING] [1.5 ms] 88 [3D FRAME DELAY] [0 us] 89 [3D TEST MODE] [NORMAL] 89 [3D TEST PATTERN] — 89 [SAFETY PRECAUTIONS MESSAGE] [ON] 90 [3D SAFETY PRECAUTIONS] — 90 *1: PT-DZ21KU and PT-DS20KU only *2: Dif fers based on the selected input terminal.
![](/img/blank.gif)
Menu navigation 66 - ENGLISH Settings ▶■[DISPLA Y OPTION] Sub-menu item Factory default Page [COLOR MATCHING] [OFF] 91 [LARGE SCREEN CORRECTION] [OFF] 92 [SCREEN SETTING] *1— 93 [AUTO SIGNAL] [OFF] 93 [AUTO SETUP] — 94 [BACKUP INPUT SETTING] — 94 [RGB IN] — 96 [DVI-D IN] — 96 [HDMI IN] — 97 [SDI IN] *1— 97 [ON-SCREEN DISPLAY] — 98 [BACK COLOR] [BLUE] 99 [STARTUP LOGO] [DEFAULT LOGO] 99 [UNIFORMITY] — 99 [SHUTTER SETTING] — 100 [FREEZE] — 100 [WAVEFORM MONITOR] [OFF] 100 [CUT OFF] — 101 *1: PT-DZ21KU and PT-DS20KU only ▶■[PROJECT OR SETUP] Sub-menu item Factory default Page [PROJECTOR ID] [ALL] 102 [PROJECTION METHOD] [FRONT/ FLOOR] 102 [COOLING CONDITION] [AUTO] 103 [HIGH ALTITUDE MODE] [OFF] 103 [LAMP SELECT] [QUAD] 103 [LAMP RELAY] [OFF] 104 [BRIGHTNESS CONTROL] — 105 [STANDBY MODE] [NORMAL] 109 [SCHEDULE] [OFF] 109 [STARTUP INPUT SELECT] [LAST USED] 110 [RS-232C] — 111 [STATUS] — 112 [NO SIGNAL SHUT-OFF] [DISABLE] 113 [REMOTE2 MODE] [DEFAULT] 113 [FUNCTION BUTTON] — 114 [DATE AND TIME] — 114 [LENS CALIBRATION] — 115 [LENS MEMORY] — 115 [SAVE ALL USER DATA] — 117 [LOAD ALL USER DATA] — 117 Sub-menu item Factory default Page [INITIALIZE] — 117 [SERVICE PASSWORD] — 117 ▶■[P IN P] Details ( page 118) ▶■ [TEST P ATTERN] Details ( page 120) ▶■[SIGNAL LIST] Details ( page 121) ▶■[SECURITY] Sub-menu item Factory default Page [SECURITY PASSWORD] [OFF] 124 [SECURITY PASSWORD CHANGE] — 124 [DISPLAY SETTING] [OFF] 125 [TEXT CHANGE] — 125 [CONTROL DEVICE SETUP] — 125 [CONTROL DEVICE PASSWORD CHANGE] — 127 ▶■ [NETWORK] Sub-menu item Factory default Page [NETWORK SETUP] ― 128 [NETWORK CONTROL] ― 128 [NETWORK STATUS] ― 128 [Art-Net SETUP] ― 128 Note z S ome items may not be adjusted or used for certain signal formats to be input to the projector. The menu items that cannot be adjusted or used are shown in gray characters, and they cannot be selected. z Sub-menu items and factory default settings dif fer depending on the selected input terminal.
![](/img/blank.gif)
[PICTURE] menu ENGLISH - 67 Settings Select [PICTURE] from the main menu, and select the item from the sub-menu. Refer to “Navigating through the menu” ( page 63) for the operation of the menu screen. z After selecting the item, press ▲▼◀▶ to set. [PICTURE MODE] You can switch to the desired picture mode suitable for the image source and the environment in which the projector is used. 1) Press ▲▼ to select [PICTURE MODE]. 2) Press ◀▶. ▶z The [PICTURE MODE] individual adjustment screen is displayed. 3) Press ◀▶ to switch the [PICTURE MODE]. ▶z The setting will change as follows each time you press the button. [STANDARD][CINEMA][NATURAL] [USER] [DICOM SIM.] [GRAPHIC][DYNAMIC] [STANDARD] The picture becomes suitable for moving images in general. [CINEMA] The picture becomes suitable for movie sources. [NATURAL] The picture is sRGB compliant. [DICOM SIM.] The picture becomes similar to that of DICOM Part14 Grayscale Standard. [DYNAMIC] The light output is maximized for use in bright areas. [GRAPHIC] The picture becomes suitable for input from to the personal computer. [USER] Set any desired picture mode. Note zThe factory default picture mode is [GRAPHIC] for s till image input signals and [STANDARD] for movie based input signals. z DICOM is an abbreviation of “Digital Imaging and COmmunication in Medicine” and is a standard for medical imaging devices. Although the DICOM name is used, the projector is not a medical device, and should not be used for purposes such as diagnosis of display images. z Press the button when each [PICTURE MODE] is selected to save as a specified value when a new signal is input. The data of all items except [SYSTEM SELECTOR] in the [PICTURE] menu is saved. z In the factory default settings, [USER] is set to images that comply with the ITU-R BT .709 standard. ▶■ To change the [USER] name 4) Select [USER] in Step 3). 5) Press the button. ▶z The [PICTURE MODE] detailed screen is displayed. 6) Press ▲▼ to select [PICTURE MODE NAME CHANGE]. 7) Press the button. ▶z The [PICTURE MODE NAME CHANGE] screen is displayed. 8) Press ▲▼◀▶ to select the character , and press the button to enter the character. 9) Press ▲▼◀▶ to select [OK], and press the button. ▶z The picture mode name is changed. [PICTURE] menu
![](/img/blank.gif)
[PICTURE] menu 68 - ENGLISH Settings [CONTRAST] You can adjust the contrast of the colors. 1) Press ▲▼ to select [CONTRAST]. 2) Press ◀▶ or the button. ▶z The [CONTRAST] individual adjustment screen is displayed. 3) Press ◀▶ to adjust the level. Operation Adjustment Range Press ▶. Brightens the screen and makes the color of image deeper. Maximum value +31 Press ◀. Darkens the screen and makes the color of image lighter. Minimum value –31 Attention z Adjust [BRIGHTNESS] first when you need to adjust the black level. [BRIGHTNESS] You can adjust the dark (black) part of the projected image. 1) Press ▲▼ to select [BRIGHTNESS]. 2) Press ◀▶ or the button. ▶z The [BRIGHTNESS] individual adjustment screen is displayed. 3) Press ◀▶ to adjust the level. Operation Adjustment Range Press ▶. Increases the brightness of the dark (black) parts of the screen. Maximum value +31 Press ◀. Reduces the brightness of the dark (black) parts of the screen. Minimum value –31 [COLOR] You can adjust the color saturation of the projected image. 1) Press ▲▼ to select [COLOR]. 2) Press ◀▶ or the button. ▶z The [COLOR] individual adjustment screen is displayed. 3) Press ◀▶ to adjust the level. Operation Adjustment Range Press ▶. Deepens colors. Maximum value +31 Press ◀. Weakens colors. Minimum value –31 [TINT] You can adjust the skin tone in the projected image. 1) Press ▲▼ to select [TINT]. 2) Press ◀▶ or the button. ▶z The [TINT] individual adjustment screen is displayed. 3) Press ◀▶ to adjust the level. Operation Adjustment Range Press ▶. Adjusts skin tone toward greenish color.Maximum value +31 Press ◀. Adjusts skin tone toward reddish purple.Minimum value –31 [COLOR TEMPERATURE] You can switch the color temperature if the white areas of the projected image are bluish or reddish. 1) Press ▲▼ to select [COLOR TEMPERA TURE]. 2) Press ◀▶ or the button. ▶z The [COLOR TEMPERATURE] individual adjustment screen is displayed. 3) Press ◀▶ to switch the [COLOR TEMPERA TURE]. ▶zThe setting will change as follows each time you press the button. [DEFAULT]*1[USER1][USER2] [9300K][3200K] (100 K increments) *1: When [PICTURE MODE] is set to [USER] or [DICOM SIM.], [DEF AULT] cannot be selected. Note z When the [COLOR MA TCHING] ( page 91) adjustment is set to any setting other than [OFF], the color temperature setting is fixed to [USER1]. z The color temperature numerical values are guidelines.
![](/img/blank.gif)
[PICTURE] menu ENGLISH - 69 Settings ▶■To adjust desired white balance 4) Select [USER1] or [USER2] in Step 3). 5) Press the button. ▶z The [COLOR TEMPERATURE] screen is displayed. 6) Press ▲▼ to select [WHITE BALANCE]. 7) Press the button. ▶z The [WHITE BALANCE] screen is displayed. 8) Press ▲▼ to select [WHITE BALANCE HIGH] or [WHITE BALANCE LOW]. 9) Press the button. ▶z The [WHITE BALANCE HIGH] screen or the [WHITE BALANCE LOW] screen is displayed. 10) Press ▲▼ to select [RED], [GREEN], and [BLUE]. 11) Press ◀▶ to adjust the level. Item OperationAdjustmentRange [RED] Press ▶. Deepens red. Maximum value High: 255 Low: 127 Minimum value High: 0 Low: –127 Default High: 255 Low: 0 Press ◀. Weakens red. [GREEN] Press ▶. Deepens green. Press ◀. Weakens green. [BLUE] Press ▶. Deepens blue. Press ◀. Weakens blue. ▶■ To adjust desired white balance based on existing color temperature settings 4) Select a setting other than [DEF AULT], [USER1], or [USER2] in Step 3). 5) Press the button. ▶z The [CHANGE TO *****] screen is displayed. 6) Press ▲▼ to select [USER1] or [USER2]. ▶z The status of the color temperature changed is saved to the selected item. 7) Press the button. ▶zThe confirmation screen is displayed. 8) Press ◀▶ to select [OK], and press the button. ▶z The [USER1] or [USER2] data is overwritten. ▶zIf you press ◀▶ to select [CANCEL] and then press the button, the data will not be overwritten. ▶z The [WHITE BALANCE HIGH] screen is displayed. 9) Press ▲▼ to select [RED], [GREEN], and [BLUE]. 10) Press ◀▶ to adjust the level. Note z Adjust [COLOR TEMPERATURE] correctly. All colors will not be displayed properly unless adequate adjustment is made. If the adjustment does not look suitable, you can press the button on the remote control to return the setting for the selected item only to the factory default setting. z When color temperature has been changed, the c olors before and after the change will differ slightly. ▶■ To change the name of [USER1] or [USER2] 4) Select [USER1] or [USER2] in Step 3). 5) Press the button. ▶z The [COLOR TEMPERATURE] screen is displayed. 6) Press ▲▼ to select [COLOR TEMPERA TURE NAME CHANGE]. 7) Press the button. ▶z The [COLOR TEMPERATURE NAME CHANGE] screen is displayed. 8) Press ▲▼◀▶ to select the character , and press the button to enter the character. 9) Press ▲▼◀▶ to select [OK], and press the button. ▶z The name set to color temperature is changed. Note z When a name is changed, display of [USER1] and [USER2] on the menu is also changed.
![](/img/blank.gif)
[PICTURE] menu 70 - ENGLISH Settings [GAMMA] Switch gamma mode. 1) Press ▲▼ to select [GAMMA]. 2) Press ◀▶ or the button. ▶z The [GAMMA] individual adjustment screen is displayed. 3) Press ◀▶ to switch the [GAMMA]. ▶z The setting will change as follows each time you press the button. [DEFAULT]*1[USER1] [2.8] [USER2] [DICOM SIM.] (0.1 increments) [1.0] [2.0][1.8] *1: When [PICTURE MODE] is set to [DYNAMIC], [USER], or [DICOM SIM.], [DEF AULT] cannot be selected. Note zDICOM is an abbreviation of “Digital Imaging and COmmunication in Medicine” and is a standard for medical imaging devices. Although the DICOM name is used, the projector is not a medical device, and should not be used for purposes such as diagnosis of display images. ▶■ To change the name of [USER1] or [USER2] 4) Select [USER1] or [USER2] in Step 3). 5) Press the button. ▶z The [GAMMA] screen is displayed. 6) Press the button. ▶z The [GAMMA NAME CHANGE] screen is displayed. 7) Press ▲▼◀▶ to select the character , and press the button to enter the character. 8) Press ▲▼◀▶ to select [OK], and press the button. ▶z The Select Gamma name is changed. Note z When a name is changed, display of [USER1] and [USER2] on the menu is also changed. [SYSTEM DAYLIGHT VIEW] You can correct the image to the optimal vividness even if it is projected under a bright light. 1) Press ▲▼ to select [SYSTEM DA YLIGHT VIEW]. 2) Press ◀▶ or the button. ▶z The [SYSTEM DAYLIGHT VIEW] individual adjustment screen is displayed. 3) Press ◀▶ to switch the [SYSTEM DA YLIGHT VIEW]. ▶zThe setting will change as follows each time you press the button. [OFF] (No correction)[1] (Low) [3] (High)[2] (Medium) [SHARPNESS] You can adjust the sharpness of the projected image. 1) Press ▲▼ to select [SHARPNESS]. 2) Press ◀▶ or the button. ▶z The [SHARPNESS] individual adjustment screen is displayed. 3) Press ◀▶ to adjust the level. Operation Adjustment Adjustment range Press ▶. Contours become sharper. 0 - 15 Press ◀. Contours become softer. Note z If you press ▶ while the adjustment value is [15], the value will become [0]. If you press ◀ while the adjustment value is [0], the value will become [15].