Have a look at the manual Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21[For assistance, please call: 1-800-272-7033] Useful Information Registration Follow the procedure below when you want to: Add an additional terminal to your HD-PLC network. Re-register the master and terminal after resetting the master. 1.Confirm that the mode selector of the master adaptor is set to MASTER . 2.Confirm that the mode selector of the terminal adaptor that you want to register is set to TERMINAL. 3.Plug the master adaptor and a power strip into the same wall outlet. Registration may not be successful if the master and power strip are connected to different wall outlets during registration. Make sure the power strip is turned on. Do not use a power strip with a noise filter or surge protector feature. 4.Plug the terminal adaptor into the power strip. 5.Reset the terminal by pressing the FACTORY DEFAULT RESET button on the terminal for about 3 seconds (see page 20). Check the position of the adaptor’s mode selector (see page 13) and make sure that you reset the terminal adaptor (not the master). 6.Press the SETUP button on both adaptors for about 1 second. The order in which they are pressed does not matter. The PLC indicator of each adaptor will begin to flash in green. Make sure you press the SETUP button on each adaptor within 3 seconds of each other. MASTER TERMINAL MASTER TERMINAL MASTERTERMINAL BL-PA300KTA_OI.book Page 21 Wednesday, August 6, 2008 10:08 AM
22 Useful Information 7.When the PLC indicator of each adaptor lights in green, registration was successful. If the PLC indicators do not light in green, see page 23. 8.Wait about 30 seconds, then unplug the adaptors and place them where you plan to use them (see page 15). Note While registering an additional terminal, communication between all other adaptors may be disrupted for about 10 seconds. BL-PA300KTA_OI.book Page 22 Wednesday, August 6, 2008 10:08 AM
23[For assistance, please call: 1-800-272-7033] Useful Information Troubleshooting Performance issues The troubleshooting notes in this section are provided to resolve the following types of performance issues. Inability to transmit data over the HD-PLC network Slow data transmission speeds (interrupted video or audio, slow download speeds, etc.) Intermittent or varied performance (faster at certain times, slower at others) Interference caused by an adaptor The PLC indicator is not lit in green even though you have registered the adaptor. Troubleshooting notes In most cases, performance issues su ch as those listed above can be resolved by performing the steps in the following troubleshooting notes. Each note contains several steps. After you perform each step, test the terminal’s network speed (see page 17) to see if the issue has been resolved. For more information, access the Panasonic PLC Support Site at: http://panasoni c.co.jp/pcc/products/en/plc/ Troubleshooting note #1: Adaptor issues Perform each step until the performance issue is solved. 1.Unplug the master and terminal adapt ors, then plug them into the wall outlets again. The indicators on th e adaptors will light if the adaptors are receiving power. If a wall outlet has a power switch, make sure it is turned on. 2.Confirm that all LAN cables are securely connected to each adaptor. Use high-quality LAN cables. Also confirm that other network devices (routers, hubs, etc.) are turned on as well as properly connected and configured. 3.Try connecting the master and/or terminal adaptor to a different wall outlet. BL-PA300KTA_OI.book Page 23 Wednesday, August 6, 2008 10:08 AM
24 Useful Information 4.If you are not able to plug an adaptor directly into a wall outlet and must use a power strip, make sure the power strip is plugged directly into a wall outlet and not to another power strip. 5.Make sure the power strip does not have a noise filter or a surge protector, as these features may in terfere with the performance of your adaptors. 6.Use a power strip with an AC cord that is as short as possible. 7.Re-register the terminal following the procedure on page 21. If the performance issue is not solved, continue to the next troubleshooting note. Troubleshooting note #2: Eliminating interference caused by other appliances Perform each step until the performance issue is solved. 1.Identify potential electrical noise emitting appliances, and unplug them (if possible) briefly while you test the adaptor’s network speed. The following appliances are more likely to produce noise: Battery chargers (including cell phone chargers) AC adaptors (including AC ad aptors for modems, routers, notebook computers, etc.) Hair dryers Vacuum cleaners Lights or lamps which have a dimmer switch or a touch-sensitive on/off feature Power drills 2.If unplugging a device seems to resolve the adaptor’s performance issue, connect the device to a different wall outlet. 3.If connecting the device to a different wall outlet does not resolve the performance issue, connect the device to a noise filtering power strip with an AC cord that is as short as possible. BL-PA300KTA_OI.book Page 24 Wednesday, August 6, 2008 10:08 AM
25[For assistance, please call: 1-800-272-7033] Useful Information Troubleshooting note #3: Eliminating interference caused by an adaptor This product may interfere with the following appliances: Short wave radios Lights or lamps which have a touch-sensitive on/off feature Other PLC adaptors which do not use the HD-PLC standard Wireless devices (includi ng wireless mice, etc.) Perform each step until the performance issue is solved. If the following steps do not resolve the issue, refer to the Panasonic PLC Support Site at: http://panasoni c.co.jp/pcc/products/en/plc/ or call our customer call center at 1-800-272-7033. 1.Make sure that the appliance is not plugged into the same wall outlet as an adaptor. 2.Move the appliance away from any nearby adaptors. 3.Connect the appliance to a power strip. 4.For short wave radios, place the radio near a window. BL-PA300KTA_OI.book Page 25 Wednesday, August 6, 2008 10:08 AM
26 Useful Information Specifications All specifications are subject to change without notice. Power Line Communication interface LAN interface StandardHD-PLC Actual transmission speed *1 *1 Speed between BL-PA300A adaptors. Results may vary depending on electrical conditions, network environment, and other factors. For information on how transmission speed is measured, access the Panasonic PLC Support Site at: http://panasonic.co.jp/pcc/products/en/plc/ UDP: Max. 90 Mbps TCP *2: Max. 65 Mbps *2 Using Linux FTP. Maximum recommended no. of adaptors per network*3 *3 Performance may be affected as more adaptors are added to the network. 16 (including the master) Maximum recommended no. of devices connected to each adaptor *4 *4 Connecting more network devices to an adaptor may increase network traffic and affect performance. 8 (when using a hub*5) *5 Only use switching hubs. Standard IEEE 802.3/IEEE 802.3u Interface 10 Base-T 100 Base-TX Auto MDI/MDI-X Protocol IPv4, IPv6, TCP, UDP Access method CSMA/CD BL-PA300KTA_OI.book Page 26 Wednesday, August 6, 2008 10:08 AM
27[For assistance, please call: 1-800-272-7033] Useful Information User interface General HD-PLC interface Indicators PLC (green, red) LAN (green, orange) MASTER (green) Other Mode Selector (MASTER or TERMINAL switch) SETUP button FACTORY DEFAULT RESET button Operational environment 0–40 °C (32–104 °F) 20%–85% humidity (without condensation) Dimensions (W x D x H) Approx. 55 mm x 33 mm x 90 mm (2 3/16 in. x 1 5/16 in. x 3 9/16 in.) Weight 150 g (0.33 lb) Power supply Input 120 V AC 60 Hz Power consumption In normal mode: 3 W In Power Save mode: less than 1 W Frequency band 2–28 MHz Modulation Wavelet OFDM (16 PAM–2 PAM) Transmission PHY rate Max. 210 Mbps *1 *1 This is the theoretical maximum data transmission speed of the HD-PLC standard. Access methodCSMA/CA Error correction Reed-Solomon encoder/decoder Convolutional encoder/Viterbi decoder Encryption AES 128-bit encryption Communication distance Approx. 200 m (650 ft.) *2 *2 Varies depending on the electrical environment. For more information, see page 7. BL-PA300KTA_OI.book Page 27 Wednesday, August 6, 2008 10:08 AM
28 Useful Information Adaptor Maintenance Screen You can access an adaptor’s maintenance screen using your computer’s web browser to perform the following tasks: Update adaptor firmware Remove terminal adaptor registration Confirm adaptor status and network information Change adaptor IP addresses Change adaptor access passwords Refer to the Panasonic PLC Support Site (http://panasonic.co.jp/pcc/products/en/plc/ ) for information about accessing and operating the adaptor maintenance screen. BL-PA300KTA_OI.book Page 28 Wednesday, August 6, 2008 10:08 AM
29[For assistance, please call: 1-800-272-7033] Useful Information FCC and other information This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inte rference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television, reception, which can be determined by tuning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected. – Consult the dealer or an experienced radio/TV technician for help. CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device. NOTICE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.This device may not cause harmful interference. 2.This device must accept any in terference received, including interference that may cause undesired operation. Responsible Party Panasonic Corporation of North America One Panasonic Way, Secaucus, New Jersey 07094 Phone number: 1-800-211-PANA (7262) BL-PA300KTA_OI.book Page 29 Wednesday, August 6, 2008 10:08 AM
30 Useful Information EnvironmentDo not place the unit in a room where the temperature is less than 0 °C (32 °F) or greater than 40 °C (104 °F). Allow 10 cm (4 in.) clearance around the unit for proper ventilation. Avoid excessive smoke, dust, mechanical vibration, shock, or direct sunlight. Routine Care Wipe the unit with a soft cloth. Do not use benzine, thinner, or any abrasive powder. When you leave the unit unused for a long period of time, unplug the adaptor from the outlet. In the Event of Trouble Consult an authorized Panasonic Factory Service Center. BL-PA300KTA_OI.book Page 30 Wednesday, August 6, 2008 10:08 AM