    Have a look at the manual Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							21[For assistance, please call: 1-800-272-7033]
    Useful Information
    Registration
    Follow the procedure below when you want to:
     Add an additional terminal to your  HD-PLC network.
     Re-register the master and terminal after resetting the master.
    1.Confirm that the mode selector of  the master adaptor is set to 
    MASTER .
    2.Confirm that the mode selector of the  terminal adaptor that you want to 
    register is set to  TERMINAL.
    3.Plug the master adaptor and a power strip into the same wall outlet.
     Registration may not be successful if the master and power strip  are connected to different wall outlets during registration.
     Make sure the power strip is turned on. Do not use a power strip  with a noise filter or surge protector feature.
    4.Plug the terminal adaptor into the power strip.
    5.Reset the terminal by pressing the  FACTORY DEFAULT RESET button 
    on the terminal for about 3 seconds (see page 20).
     Check the position of the adaptor’s mode selector (see page 13)  and make sure that you reset the terminal adaptor (not the 
    master).
    6.Press the  SETUP button on both adaptors for about 1 second. The 
    order in which they are pressed does not matter.
     The  PLC indicator of each adaptor will begin to flash in green.
     Make sure you press the  SETUP button on each adaptor within 3 
    seconds of each other.
    MASTER
    TERMINAL
    MASTER TERMINAL
    MASTERTERMINAL
    BL-PA300KTA_OI.book  Page 21  Wednesday, August 6, 2008  10:08 AM 
    						
    							22
    Useful Information
    7.When the PLC indicator of each adaptor lights in green, registration 
    was successful.
    If the  PLC indicators do not light in green, see page 23.
    8.Wait about 30 seconds, then unplug the adaptors and place them 
    where you plan to use them (see page 15).
    Note
     While registering an additional terminal, communication between all  other adaptors may be disrupted for about 10 seconds.
    BL-PA300KTA_OI.book  Page 22  Wednesday, August 6, 2008  10:08 AM 
    						
    							23[For assistance, please call: 1-800-272-7033]
    Useful Information
    Troubleshooting
    Performance issues
    The troubleshooting notes in this section are provided to resolve the 
    following types of performance issues.
     Inability to transmit data over the  HD-PLC network
     Slow data transmission speeds (interrupted video or audio, slow  download speeds, etc.)
     Intermittent or varied performance (faster at certain times, slower at  others)
     Interference caused by an adaptor
    The  PLC indicator is not lit in green even though you have registered 
    the adaptor.
    Troubleshooting notes
    In most cases, performance issues su ch as those listed above can be 
    resolved by performing the steps in the following troubleshooting notes. 
    Each note contains several steps. After you perform each step, test the 
    terminal’s network speed (see page 17) to see if the issue has been 
    resolved. For more information, access the Panasonic PLC Support Site at: 
    http://panasoni c.co.jp/pcc/products/en/plc/
    Troubleshooting note #1:
    Adaptor issues
    Perform each step until the performance issue is solved. 
    1.Unplug the master and terminal adapt ors, then plug them into the wall 
    outlets again. The indicators on th e adaptors will light if the adaptors 
    are receiving power. If a wall outlet has a power switch, make sure it is 
    turned on.
    2.Confirm that all LAN cables are securely connected to each adaptor. 
    Use high-quality LAN cables. Also confirm that other  network devices 
    (routers, hubs, etc.) are  turned on as well as properly connected and 
    configured.
    3.Try connecting the master and/or terminal adaptor to a different wall 
    outlet.
    BL-PA300KTA_OI.book  Page 23  Wednesday, August 6, 2008  10:08 AM 
    						
    							24
    Useful Information
    4.If you are not able to plug an adaptor directly into a wall outlet and must 
    use a power strip, make sure the power strip is plugged directly into a 
    wall outlet and not to another power strip.
    5.Make sure the power strip does not have a noise filter or a surge 
    protector, as these features may in terfere with the performance of your 
    adaptors.
    6.Use a power strip with an AC cord that is as short as possible.
    7.Re-register the terminal following the procedure on page 21.
    If the performance issue is not solved, continue to the next troubleshooting 
    note.
    Troubleshooting note #2:
    Eliminating interference  caused by other appliances
    Perform each step until the performance issue is solved.
    1.Identify potential electrical noise emitting appliances, and unplug them 
    (if possible) briefly while you test the adaptor’s network speed.
    The following appliances are more likely to produce noise:
     Battery chargers (including cell phone chargers)
     AC adaptors (including AC ad aptors for modems, routers, 
    notebook computers, etc.)
     Hair dryers
     Vacuum cleaners
     Lights or lamps which have a dimmer switch or a touch-sensitive  on/off feature
     Power drills
    2.If unplugging a device seems to resolve the adaptor’s performance 
    issue, connect the device to a different wall outlet. 
    3.If connecting the device to a different wall outlet does not resolve the 
    performance issue, connect the device to a noise filtering power strip 
    with an AC cord that is as short as possible.
    BL-PA300KTA_OI.book  Page 24  Wednesday, August 6, 2008  10:08 AM 
    						
    							25[For assistance, please call: 1-800-272-7033]
    Useful Information
    Troubleshooting note #3:
    Eliminating interference caused by an adaptor
    This product may interfere with the following appliances:
     Short wave radios
     Lights or lamps which have a  touch-sensitive on/off feature
     Other PLC adaptors which do not use the HD-PLC  standard
     Wireless devices (includi ng wireless mice, etc.)
    Perform each step until the performance issue is solved. If the following 
    steps do not resolve the issue, refer to the Panasonic PLC Support Site at: 
    http://panasoni c.co.jp/pcc/products/en/plc/  or call our customer call 
    center at 1-800-272-7033.
    1.Make sure that the appliance is not plugged into the same wall outlet 
    as an adaptor.
    2.Move the appliance away from any nearby adaptors.
    3.Connect the appliance to a power strip.
    4.For short wave radios, place the radio near a window. 
    BL-PA300KTA_OI.book  Page 25  Wednesday, August 6, 2008  10:08 AM 
    						
    							26
    Useful Information
    Specifications
    All specifications are subject to change without notice.
    Power Line Communication interface
    LAN interface
    StandardHD-PLC
    Actual transmission speed
    *1
    *1 Speed between BL-PA300A adaptors. Results may vary depending on electrical  conditions, network environment, and other factors. For information on how 
    transmission speed is measured, access  the Panasonic PLC Support Site at: 
    http://panasonic.co.jp/pcc/products/en/plc/
    UDP: Max. 90 Mbps
    TCP
    *2: Max. 65 Mbps
    *2 Using Linux FTP.
    Maximum recommended no. 
    of adaptors per network*3
    *3 Performance may be affected as more adaptors are added to the network.
    16 (including the master)
    Maximum recommended no. 
    of devices connected to each 
    adaptor
    *4
    *4 Connecting more network devices to an  adaptor may increase network traffic and 
    affect performance.
    8 (when using a hub*5)
    *5 Only use switching hubs.
    Standard IEEE 802.3/IEEE 802.3u
    Interface 10 Base-T
    100 Base-TX
    Auto MDI/MDI-X
    Protocol IPv4, IPv6, TCP, UDP
    Access method CSMA/CD
    BL-PA300KTA_OI.book  Page 26  Wednesday, August 6, 2008  10:08 AM 
    						
    							27[For assistance, please call: 1-800-272-7033]
    Useful Information
    User interface
    General
    HD-PLC interface
    Indicators PLC (green, red)
    LAN  (green, orange)
    MASTER  (green)
    Other Mode Selector (MASTER or TERMINAL  
    switch)
    SETUP  button
    FACTORY DEFAULT RESET  button
    Operational environment 0–40 °C (32–104 °F) 20%–85% humidity (without condensation)
    Dimensions (W x D x H) Approx. 55 mm x 33 mm x 90 mm (2 3/16 in. x 1 5/16 in. x 3 9/16 in.)
    Weight 150 g (0.33 lb)
    Power supply Input 120 V AC  60 Hz
    Power consumption In normal mode: 3 W In Power Save mode: less than 1 W
    Frequency band 2–28 MHz
    Modulation Wavelet OFDM (16 PAM–2 PAM)
    Transmission PHY rate Max. 210 Mbps
    *1
    *1 This is the theoretical maximum data transmission speed of the HD-PLC  standard.
    Access methodCSMA/CA
    Error correction Reed-Solomon encoder/decoder
    Convolutional encoder/Viterbi decoder
    Encryption AES 128-bit encryption
    Communication distance Approx. 200 m (650 ft.)
    *2
    *2 Varies depending on the electrical environment. For more information, see page 7.
    BL-PA300KTA_OI.book  Page 27  Wednesday, August 6, 2008  10:08 AM 
    						
    							28
    Useful Information
    Adaptor Maintenance Screen
    You can access an adaptor’s maintenance screen using your computer’s 
    web browser to perform the following tasks: Update adaptor firmware
     Remove terminal adaptor registration
     Confirm adaptor status and network information
     Change adaptor IP addresses
     Change adaptor access passwords
    Refer to the Panasonic PLC Support Site 
    (http://panasonic.co.jp/pcc/products/en/plc/ ) for information about 
    accessing and operating the adaptor maintenance screen.
    BL-PA300KTA_OI.book  Page 28  Wednesday, August 6, 2008  10:08 AM 
    						
    							29[For assistance, please call: 1-800-272-7033]
    Useful Information
    FCC and other information
    This equipment has been tested and found to comply with the limit for a 
    Class B digital device, pursuant to Part  15 of the FCC rules. These limits are 
    designed to provide reasonable protection against harmful interference in a 
    residential installation. This equipment generates, uses, and can radiate 
    radio frequency energy and, if not installed and used in accordance with the 
    instructions, may cause harmful inte rference to radio communications. 
    However, there is no guarantee that interference will not occur in a particular 
    installation. If this equipment does cause harmful interference to radio or 
    television, reception, which can be determined by tuning the equipment off 
    and on, the user is encouraged to try to correct the interference by one or 
    more the following measures:
    – Reorient or relocate the receiving antenna.
    – Increase the separation between the equipment and receiver.
    – Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected.
    – Consult the dealer or an experienced radio/TV technician for  help.
    CAUTION Any changes or modifications not expressly approved by the party 
    responsible for compliance could void  the user’s authority to operate this 
    device.
    NOTICE This device complies with Part 15 of  the FCC Rules. Operation is subject 
    to the following two conditions:
    1.This device may not cause harmful interference.
    2.This device must accept any in terference received, including 
    interference that may cause undesired operation.
    Responsible Party Panasonic Corporation of North America
    One Panasonic Way, Secaucus, New Jersey 07094
    Phone number: 1-800-211-PANA (7262)
    BL-PA300KTA_OI.book  Page 29  Wednesday, August 6, 2008  10:08 AM 
    						
    							30
    Useful Information
    EnvironmentDo not place the unit in a room where the temperature is less than 0 °C 
    (32 °F) or greater than 40 °C (104 °F). Allow 10 cm (4 in.) clearance 
    around the unit for proper ventilation. Avoid excessive smoke, dust, 
    mechanical vibration, shock, or direct sunlight.
    Routine Care Wipe the unit with a soft cloth. Do not use benzine, thinner, or any 
    abrasive powder. When you leave the unit unused for a long period of 
    time, unplug the adaptor from the outlet.
    In the Event of Trouble
    Consult an authorized Panasonic Factory Service Center.
    BL-PA300KTA_OI.book  Page 30  Wednesday, August 6, 2008  10:08 AM 
    						