Home > Panasonic > Adapter > Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions

Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Operating Instructions
    PLC Adaptor Starter Pack
    Power Line Communication
    Model No.
      BL-PA300KTA
    Set of 2 Adaptors (Master and Terminal)
    PLC LANMASTERHD-P LC
    B
    L-P A300
    SE TUPPLC
    LANMASTERHD-P LC
    B
    L-P A300
    SE TUP
    Operating Instructions..........................................................  2
    Instrucciones de operación.................................................  31
    Limited warranty.....................................................................  59
    Customer services.................................................................  61
    BL-PA300KTA_OI.book  Page 1  Wednesday, August 6, 2008  10:08 AM 
    						
    							IMPORTANT NOTES:
    For best results, connect this product directly to a wall outlet.
    This product may not function normally in certain electrical 
    environments.
    See page 7 for more information.
    Please read this document before use and save this document for future reference.
    Introduction
    IMPORTANT SAFETY INSTRUCTIONS ....................................... 6
    Electrical environment information... .............................................. 7
    Security information ....................................................................... 9
    Security notices for when sending an adaptor for service ........... 10
    How does it work? ....................................................................... 11
    Main unit ...................................................................................... 13
    Installation
    Placing the adaptors ....... .......................................... ................... 15
    Power Save Mode ....................................................................... 15
    Connecting adaptors to network de vices ..................................... 16
    Useful Information
    Testing a terminal’s network speed ............................................. 17
    Understanding the indicators ........... ............................................ 19
    Resetting an adaptor ...... .......................................... ................... 20
    Registration.................................................................................. 21
    Troubleshooting ........................................................................... 23
    Specifications............................................................................... 26
    Adaptor Maintenance Screen ...................................................... 28
    FCC and other information .......................................................... 29
    Table of Contents
    BL-PA300KTA_OI.book  Page 2  Wednesday, August 6, 2008  10:08 AM 
    						
    							3[For assistance, please call: 1-800-272-7033]
    Introduction
    IntroductionThank you for purchasing a Panasonic  HD-PLC product.
    Main features
    Flexible and stable network access anywhere in your home
    The BL-PA300A offers the next generation in home networking: High 
    Definition Power Line Communication ( HD-PLC). High-speed network 
    access and high performance data transfers are now available in any room.
    Every AC outlet becomes a home network access point
    Because  HD-PLC technology makes use of the existing electrical wiring in 
    your home, there’s no need to run cables between rooms.
    Easy to expand
    Up to 16 adaptors in all can be used, which means you can add additional 
    adaptors whenever you need to add a network connection in another room 
    of the house.
    Simple network speed testing
    You can confirm the speed of each adaptor’s  HD-PLC connection by simply 
    pressing a button.
    Fast, reliable, and secure
    With speeds of up to 210 Mbps (PHY rate)
    *1, advanced error correction, and 
    AES 128-bit encryption, the BL-PA300A  provides peace of mind at the 
    speed of light.
    Power Save Mode
    The BL-PA300A in normal operation has power consumption of around 3 W, 
    however, if a terminal’s LAN port is inactive for more than 20 minutes, the 
    adaptor automatically enters Power Save mode, and power consumption is 
    reduced to less than 1 W.
    For more information about how  HD-PLC works, see page 11.
    *1This is the theoretical maximum data transmission speed of the  HD-PLC standard. 
    The actual maximum data transmission spe ed is about 90 Mbps for UDP and 65 Mbps 
    for TCP. Results may vary depending on el ectrical conditions, network environment, 
    and other factors. See the specifications for more information.
    BL-PA300KTA_OI.book  Page 3  Wednesday, August 6, 2008  10:08 AM 
    						
    							4
    Introduction
    Included items
    Confirm that the following items are included with this product.
    Additional items can be ordered by calling 1-800-332-5368.
    Available accessories
    You can add additional adaptors as necessary. Up to 16 adaptors in all 
    (including the 2 adaptors included with this product) can be used.
    Abbreviations
     This product is referred to as “the adaptor” in this document.PLC Adaptor
    ................................ 2
    (1 Master and 1 Terminal)  LAN Cable
    .................................... 2 
    Order No.: PQJA10138Z
    Getting Started ............................. 1 Operating Instructions
    (this document)............................. 1
    BL-PA300A  (PLC Adaptor Add-on 
    Unit) BL-PA100A
     (PLC Adaptor Add-on 
    Unit)
    P LC
    LAN
    MAST ERHD-P LC
    B
    L-P A 300
    S ET UPPL C
    LAN
    MAST ERHD-P LC
    B
    L-P
    A 300
    S ETU P
    PLC
    LAN
    MAS TERHD-P LC
    B
    L-P A 300
    S ETU P
    BL-PA300KTA_OI.book  Page 4  Wednesday, August 6, 2008  10:08 AM 
    						
    							5[For assistance, please call: 1-800-272-7033]
    Introduction
    Trademarks
    Linux® is the registered trademark of Li nus Torvalds in the U.S. and other 
    countries.
     HD-PLC or  HD-PLC mark is a registered trademark or trademark of 
    Panasonic Corporation in Japan and in other countries.
     All other trademarks identified herein are the property of their respective  owners.
    BL-PA300KTA_OI.book  Page 5  Wednesday, August 6, 2008  10:08 AM 
    						
    							6
    Introduction
    IMPORTANT SAFETY INSTRUCTIONS
    When using this product, basic safety precautions should always be followed 
    to reduce the risk of fire, electric shock, or personal injury.
    1.Read and understand all instructions. Keep this document for future 
    reference.
    2.Follow all instructions in this document and heed all warnings.
    3.Do not install this product near any heat sources such as radiators, 
    heat registers, stoves,  or other devices (including amplifiers) that 
    produce heat.
    4.This product is used as the main di sconnect device. Ensure that the AC 
    outlet is installed near this product and is easily accessible.
    5.The adaptor must remain connected at all times.
    6.To prevent the risk of fire or electric al shock, do not expose this product 
    to rain or any type of moisture, and do not plug it in upside-down (i.e., 
    with the LAN jack pointing up).
    7.Do not touch the product during lightning storms.
    8.Unplug this product when unused for a long period of time.
    9.Refer all servicing to qualified service personnel. Servicing is required 
    when the unit does not operate normally, has been damaged in any 
    way, or after the unit has been dropped.
    10.Do not use this product outdoors.
    11.Unplug this unit from power outlets if  it emits smoke, an abnormal smell 
    or makes unusual noise. These conditions can cause fire or electric 
    shock. Confirm that smoke has st opped and contact an authorized 
    service center.
    SAVE THESE INSTRUCTIONS
    BL-PA300KTA_OI.book  Page 6  Wednesday, August 6, 2008  10:08 AM 
    						
    							7[For assistance, please call: 1-800-272-7033]
    Introduction
    Electrical environment information
    HD-PLC adaptors communicate with each other using the existing electrical 
    wiring in your home, and may be affected  by electrical noise or the length of 
    your home’s wiring. Keep the following in mind when placing each adaptor.
    AC outlets
    For best results, we recommend connecting the adaptors directly to a wall 
    outlet. Avoid connecting high power-consuming appliances to the same wall 
    outlet. Additionally, connecting an adaptor to a uninterruptable power supply 
    (UPS) or backup power supply device is not recommended.
    While connecting the adaptors to a wall outlet is recommended, keep the 
    following in mind if you must connect an adaptor to a power strip:
     Make sure the power strip does not have a noise filter or a surge protector, as these features ma y interfere with the performance of 
    your adaptors.
     Do not connect the adaptor to a power strip that receives power from  another power strip.
     Use a power strip with an AC cord that is as short as possible.
    Electrical interference
    Certain electrical devices emit electrical noise. If this noise is passed on to 
    the electrical wiring in your home, it may interfere with the performance, 
    speed, and reliability of your adaptors. For best results, we recommend 
    connecting an electrical noise filter to noise emitting appliances.
    The following appliances are more likely to produce noise:  Battery chargers (including cell phone chargers)
     AC adaptors (including AC adaptor s for modems, routers, notebook 
    computers, etc.)
     Hair dryers
     Vacuum cleaners
     Lights or lamps which have a dimm er switch or a touch-sensitive 
    on/off feature
     Power drills
    Additionally, this product may interfere with the following appliances:  Short wave radios
     Lights or lamps which have a  touch-sensitive on/off feature
     Wireless devices (includi ng wireless mice, etc.)
    BL-PA300KTA_OI.book  Page 7  Wednesday, August 6, 2008  10:08 AM 
    						
    							8
    Introduction
    Electrical wiring
    HD-PLC adaptors communicate with each other using the existing electrical 
    wiring in your home. If 2 wall outlets are separated by a great length of 
    electrical wiring, the adaptors connected to those outlets may not be able to 
    communicate with each other.
    For more information, refer to the troubleshooting section (see page 23) or 
    access the Panasonic PLC Support Site at: 
    http://panasonic.co.jp/pcc/products/en/plc/
    After you have placed the adaptors w here you plan to use them and plugged 
    them into the wall outlets, test the terminal’s network speed (see page 17).
    BL-PA300KTA_OI.book  Page 8  Wednesday, August 6, 2008  10:08 AM 
    						
    							9[For assistance, please call: 1-800-272-7033]
    Introduction
    Security information
    1.With any network connection, security is a concern. The BL-PA300A 
    provides security to prevent unauthorized access to your network.
     Only terminals that are registered to the master adaptor can  communicate with the network.
     A terminal may be registered to the master only if the  SETUP 
    buttons on the master and terminal are pressed within 3 seconds 
    of each other.
    2.Data sent and received over the  HD-PLC network employs AES 128-bit 
    encryption, however we cannot guarantee that data will not be 
    intercepted by a third party.
    3.For security, reset your adaptors (see page 20) in the following 
    situations.
     If you are concerned that another adaptor may have been  accidentally registered to your ma ster (for example, the adaptor 
    of someone who lives in the same apartment building as you), 
    reset each of your adaptors and register them again.
     If you discard an adaptor, give an adaptor to someone else to  use, or send an adaptor for servicing, reset the adaptor first.
     If you lose an adaptor, reset your remaining adaptors and register  them again.
    4.The adaptor does not have a firewall feature. To prevent unauthorized 
    external access to the network, we recommend performing the 
    following steps.
     Setup security measures for the router and computers accessing  the network.
     Change the default password on the Adaptor Maintenance  Screen.
    Refer to the Panasonic PLC Support Site
    (http://panasonic.co.jp/pcc/prod ucts/en/plc/) for information 
    about changing the default password.
    BL-PA300KTA_OI.book  Page 9  Wednesday, August 6, 2008  10:08 AM 
    						
    							10
    Introduction
    Security notices for when sending an adaptor 
    for service
    Please note the following when sending an adaptor for servicing. Reset the adaptor before sending it for servicing.
     After your master adaptor is serv iced, you must register all your 
    terminals to the master again.
     After a terminal adaptor is serviced, you must register the  terminal to the master again.
    BL-PA300KTA_OI.book  Page 10  Wednesday, August 6, 2008  10:08 AM 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic PLC Adaptor Starter Pack BL-PA300KTA Operating Instructions