Page 21
21 Set the maximum refresh interval [Performance] Click the [System] button, and then click the [Performance] tab to display the Performance page. Enter a number of images to be refreshed per second. Maximum refresh interval (JPEG/VGA) Enter a number from 1 to 300 (ips) for the maximum refresh interval. An image to be refreshed is a JPEG image of VGA size (640 x 480). Default:100 (ips)[Set] button The edited settings will be saved and applied. Notes: •The default is the value determined on the...
Page 22
22 Configure the settings relating to the camera title [Text display setting] Click the [System] button, and then click the [Text display setting] tab to display the Text display setting page. On/off of the camera title display, font size and display position can be configured. The camera title setting can be configured on the Camera setup page of each device. Refer to page 26, 33, 39 for further information about the camera title. Text display Select ON or OFF to determine whether or not to display the...
Page 23
23 Settings relating to the device management Devices can be registered, and the registered information can be edited or deleted. The maximum number of device registration varies depending on the device type. Refer to the System specifications section (page 4) for number of the devices that can be registered. Register a recorder [Basic setup] Step 1 Click the [Device mng.] button. →The Basic setup page of Device mng. will be displayed. Step 2 Click the [Recorder] tab. →The Registered device window of...
Page 24
24 Important: •When displaying images directly from cameras, live images will be received without using a proxy serv- er. •When receiving MPEG-4 images, live images will be received without using a proxy server. Note: The proxy server address can be set on the [Basic setup] tab of the Comm page (page 54). [Start…] button Recorder information will be downloaded based on the settings of Address, HTTP port number and Use a proxy server. Model no. The model number contained in the downloaded recorder...
Page 25
25 Step 6 Click the [OK] button. →The downloading status window will be displayed. To cancel downloading the recorder information, click the [Cancel] button on the displayed down- loading status window. Step 7 The message window will be displayed when down- load process ended. 1. Click the [OK] button. →The confirmation window will close. 2. Go to step 8. 1. Click the [OK] button on the error message window and check if the information on the Device regis- tration window has been edited correctly....
Page 26
26 Step 9 Click the [Setup…] button. →The Camera setup window will be displayed. The following are descriptions about each item dis- played on the Camera setup window of the recorder. [Camera 1-16]/[Camera 17-32] tabs Click the tab to change the setup page. Notes: •Only the [Camera 1-16] tab will be displayed when the recorder is the ND200. •The [Camera 1-16] tab will not be displayed when the recorder is the HD300. CH The camera channel numbers will be displayed.Title The camera titles contained in...
Page 27
27 Live image source Select Camera or Recorder to determine whether to display live images directly from the camera or via the recorder. Recorder:Display live images from the camera via the recorder Camera:Display live images directly from the camera Even when selecting Camera, it is necessary to register the camera in the recorder. Refer to the operating instructions of the recorder in use for how to register the camera. Default: Model no. Live image source WV-NF284 Camera WV-NP24x Camera WV-NP100x...
Page 28
28 Model no. Resolution WV-NF284 Auto/QVGA/VGA WV-NP24x Auto/QVGA/VGA WV-NP100x Auto/QVGA/VGA/SXVGA*1 WV-NS202 Auto/QVGA/VGA WV-NS202A Auto/QVGA/VGA WV-NW484 Auto/QVGA/VGA WJ-NT304 --*2 WV-NP472 --*2 WV-NS32x --*2 WV-NW47x --*2 Others --*2 *1 When Partial is selected for the scan mode of the camera, the resolution will be 960 x 720. *2 Cannot select any parameter for Resolution (JPEG). Refresh interval (JPEG) Determine the refresh interval of the camera (number of images to be refreshed per second). The...
Page 29
29 Edit the registered recorder information [Basic setup] Step 1 Display the Registered device window of the recorder. (page 23) Step 2 Select the recorder whose information is to be edited, and then click the [Edit…] button. →The Device registration window will be displayed. Step 3 Click the [Set] button after editing the information. Refer to the Register a recorder [Basic setup] section (page 23) for further information. →The Device registration window will close and the settings will be saved and...
Page 30
30 Delete the registered recorder [Basic setup] Step 1 Display the Registered device window of the recorder. (page 23) Step 2 Select the recorder to be deleted. Step 3 Click the [Delete…] button. →The confirmation window will be displayed. Step 4 Click the [OK] button. →The device information will be deleted. Note: When a message window is displayed by clicking the [Delete…] button, refer to the Displayed mes- sages and solutions section on page 73 and follow the instructions.