Have a look at the manual Panasonic Network Camera BL-VT164 Series BL-VP100 Series Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Notify of alarm occurrences to the designated IP addresses (Panasonic alarm protocol notification) This function is available only when a Panasonic device, such as the network disk recorder, is connected to the system. When “On” is selected for “Panasonic alarm protocol”, the connected Panasonic device will be notified that the camera is in the alarm state. The settings for Panasonic alarm protocol can be configured in the Panasonic alarm protocol section of the [Notification] tab of the [Alarm] page. ( ®page 88)Operating Instructions31 3 Action at an alarm occurrence
4 Transmit images onto an FTP serverImages can be transmitted to an FTP server. By configuring the following settings, transmission of images captured at an alarm occurrence or captured at a designated interval to an FTP server will become available. IMPORTANT •When using this function, set the user name and the password to access the FTP server to restrict users who can log into the FTP server. 4.1 Transmit an alarm image at an alarm occurrence (Alarm image transmission) An alarm image can be transmitted at an alarm occurrence to the FTP server. To transmit alarm images to an FTP server, it is necessary to configure the settings in advance. The settings for the FTP server can be configured on the [FTP] tab of the “Server” page. ( ®page 100) The alarm image transmission function can be turned on/off in the “Alarm image” section of the [ Alarm] tab of the “Alarm” page. ( ®page 80) Note •Depending on the network traffic, the number of the transmitted images may not reach the set number of images to be transmitted. 4.2 Transmit images at a designated interval or period (FTP periodic image transmission) Images can be transmitted at a designated interval or period. To transmit images at a designated interval or period, it is necessary to configure the settings in advance. The settings for the FTP server can be configured on the [FTP] tab of the “Server” page. ( ®page 100) It is possible to determine whether or not to use the FTP periodic image transmission function and to configure the settings relating to alarm images and the schedule on the [FTP img. trans.] tab of the “Network” page. ( ® page 135) Note •Depending on the line speed or the traffic, images may not be transmitted at the designated interval. • When “On” is selected for both the alarm image transmission function and the FTP periodic image transmission function, the alarm image transmission function will be given priority over the FTP periodic image transmission function. Therefore, images may not be transmitted at the interval designated on the “FTP periodic image transmission” setting. 32Operating Instructions 4 Transmit images onto an FTP server
5 About the network security 5.1 Equipped security functions The following security functions are featured in this camera. Access restrictions by the host authentication and the user authentication It is possible to restrict users from accessing the camera by setting the host authentication and/or the user authentication to “On”. ( ®page 94, page 95) Access restrictions by changing the HTTP port It is possible to prevent illegal access such as port scanning, etc. by changing the HTTP port number. ( ® page 107) Access encryption by the HTTPS function It is possible to enhance the network security by encrypting the access to cameras using the HTTPS function. ( ®page 112) IMPORTANT •Design and enhance security countermeasures to prevent leakage of information such as image data, authentication information (user name and password), alarm E-mail information, FTP server information, DDNS server information, etc. Perform the countermeasure such as access restriction (using the user authentication) or access encryption (using the HTTPS function). • After the camera is accessed by the administrator, make sure to close the browser for added security. • Change the administrator password periodically for added security. Note •When user authentication (authentication error) has failed to pass 8 times within 30 seconds using the same IP address (PC), access to the camera will be denied for a while. Operating Instructions33 5 About the network security
6 Display the setup menu from a PCThe settings of the camera can be configured on the setup menu. IMPORTANT•The setup menu is only operable by users whose access level is “1. Administrator”. Refer to page 94 for how to configure the access level. 6.1 How to display the setup menu 1.Display the “Live” page. ( ®page 7) 2. Click the [Setup] button on the “Live” page. When the authentication window is displayed, enter the user name and password, then click [OK]. The default user name and password are as follows. User name: admin Password: 12345 → The setup menu will be displayed. Refer to page 37 for further information about this menu. Note •When “Off” is selected for “User auth.”, if the [Setup] button is clicked, an authentication window is displayed. A user name and password must be entered. The default user name and password are as follows. User name: admin Password: 12345 34Operating Instructions 6 Display the setup menu from a PC
6.2 How to operate the setup menu Menu buttons Setup page 1. Click the desired button in the frame on the left of the window to display the respective setup menu. When there are tabs at the top of the “Setup” page displayed in the frame on the right of the window, click the desired tab to display and configure the setting items relating to the name of the tab. 2. Complete each setting item displayed in the frame on the right of the window. 3. After completing each setting item, click the [Set] button to apply them. IMPORTANT •When there are two or more [ Set] and [ Execute ] buttons on the page, click the respective button to the edited setting item. When completing the setting items in field A, click the [Set] button ( B) below field ( A). Operating Instructions35 6 Display the setup menu from a PCAB A C D B
The edited settings in field A will not be applied unless the [ Set] button ( B) below field ( A) is clicked. In the same manner as above, click the [Set] button ( D) below field C when completing the setting items in field C.36Operating Instructions 6 Display the setup menu from a PC
6.3 About the setup menu window [Setup] button Display the “Setup” page. [Live] button Display the “Live” page. [Basic] button Displays the “Basic” page. The basic settings such as time and date and camera title can be configured on the “Basic” page. ( ®page 39) [Internet] button Displays the “Internet” page. The Internet settings such as UPnP (Auto port forwarding), DDNS (Viewnetcam.com) and the network settings for the Internet can be configured on the “Internet” page. ( ® page 44) [Image/Audio] button Displays the “Image/Audio” page. The settings relating to image quality, image capture size and camera actions of JPEG/H.264 camera images can be configured on the “Image/Audio” page. ( ®page 46) [Image] button Displays the “Image” page. The settings relating to image quality, image capture size, etc. of JPEG/H.264 camera images can be configured on the “Image” page. ( ®page 46) [Multi-screen] button Displays the “Multi-screen” page. The cameras from which images are to be displayed on a multi-screen can be registered on the “Multi-screen” page. ( ®page 75) [Alarm] button Displays the “Alarm” page. The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the alarm occurrence notification, and the VMD area settings can be configured on the “Alarm” page. ( ®page 77) Operating Instructions37 6 Display the setup menu from a PCP B C D E F G H I J K L M NO A VT164WVT164W VT164VT164 VP104WVP104W VP104VP104 VP101VP101
[Advanced func.] button Displays the “Advanced func. ” page. The setting relating to the XML notification, destinations of information about the face detection and the settings relating to the face detection can be configured on the “Advanced func.” page. ( ®page 91) [User mng.] button Displays the “User mng.” page. The settings relating to the authentication such as users and PCs restrictions for accessing the camera can be configured on the “User mng.” page. ( ®page 94) [Server] button Displays the “Server” page. The settings relating to the E -mail server, the FTP server and the NTP server to which the camera accesses can be configured on the “Server” page. ( ®page 99) [Network] button Displays the “Network” page. The network settings and the settings relating to DDNS (Dynamic DNS), SNMP (Simple Network Management Protocol) and the FTP (File Transfer Protocol) periodic transmission can be configured on the “Network” page. ( ®page 104) [Schedule] button Displays the “Schedule” page. On the “Schedule” page, it is possible to designate time zones to allow to receive alarm input or to allow to activate the VMD detection function. ( ®page 151) [Maintenance] button Displays the “Maintenance” page. System log check, firmware upgrade, status check and initialization of the setup menu can be carried out on the “Maintenance” page. ( ®page 154) [Privacy] button Press [Privacy] button to hide the camera images from view temporarily and protect your privacy. ( ® page 159) Camera title The title of the camera whose settings are currently being configured will be displayed. Setup page Pages of each setup menu will be displayed. There are tabs for some setup menus. 38Operating Instructions 6 Display the setup menu from a PC VT164WVT164W VT164VT164
7 Configure the basic settings of the camera [Basic] The basic settings such as camera title, time and date, etc. can be configured on the “Basic” page. ( ® page 34, page 35) [Camera title] Enter the title of the camera. Click the [Set] button after entering the title of the camera. The entered title will be displayed in the “Camera title” field. • Available number of characters: 0 - 20 characters • Unavailable characters: " & • Default: Varies as follows depending on the model in use. BL-VT164W /BL-VT164 /BL-VP104W /BL-VP104 /BL-VP101 [Date/time] Enter the current time and date. When “12h” is selected for “Time display format ”, “AM” or “PM” can be selected. • Available range: 01/01/2010 00:00:00 - 31/12/2035 23:59:59 Operating Instructions39 7 Configure the basic settings of the camera [Basic] VT164WVT164W VT164VT164 VP104WVP104W VP104VP104 VP101VP101
IMPORTANT•Depending on the conditions such as the ambient temperature and operating period, the configured time & date may not be accurate. • Use an NTP server when the more accurate time & date setting is required for the system operation. ( ® page 101) [Time display format] Select the time display format from “24h”, “12h” and “Off”. Enter the current hour reflecting this setting when entering the current time and date for “Date/time”. To hide time and date, select “Off”. • Default: 24h [Date/time display format] Select a date/time display format. When “2010/04/01 13:10:00” is set for “Date/time” after selecting “24h” for “Date/time display format”, time & date will be respectively displayed as follows. • DD/MM/YYYY: 01/04/2010 13:10:00 • MM/DD/YYYY: 04/01/2010 13:10:00 • DD/Mmm/YYYY: 01/Apr/2010 13:10:00 • YYYY/MM/DD: 2010/04/01 13:10:00 • Mmm/DD/YYYY: Apr/01/2010 13:10:00 • Default: – DD/MM/YYYY (E/U model) – Mmm/DD/YYYY (P model) [Summer time (daylight saving)] Select “In”, “Out” or “Auto” to determine whether or not to apply daylight saving time. Configure this setting if the summer time (daylight saving time) is applied in the location where the camera is in use. • In: Applies summer time. An asterisk (*) will be displayed on the left side of the displayed time and date. • Out: Does not apply summer time. • Auto: Applies summer time in accordance with the settings for “Start time & date” and “End time & date” (month, week, day of the week, time). • Default: Out [NTP/Time zone] When “NTP >>” is clicked, the [NTP] tab of the “Server” page will be displayed. ( ®page 101) [Start time & date] [End time & date] When “Auto” is selected for “Summer time (daylight saving)”, select the time & date for the start time and the date time (month, week, day of the week, time). [Camera title on screen] Select “On” or “Off” to determine whether or not to display the camera title on the screen. When “On” is selected, the character string entered for “Camera title on screen (0-9, A-Z)” will be displayed at the position selected for “OSD”. • Default: Off Note •When moving the camera to a preset position, the characters configured for “Camera title on screen” will be deleted, and the preset ID will be displayed instead. [Camera title on screen (0-9, A-Z)] Enter a character string to be displayed on the image. • Available number of characters: 0 - 20 characters 40Operating Instructions 7 Configure the basic settings of the camera [Basic]